Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Study the sensitivity of dose calculation in prism treatment planning system using Monte Carlo simulation of 6 MeV electron beam

Prism is a non-commercial Radiotherapy Treatment Planning System (RTPS) develop by Ira J. Kalet from Washington University. Inhomogeneity factor is included in Prism TPS dose calculation. The aim of this study is to investigate the sensitivity of dose calculation on Prism using Monte Carlo simulation. Phase space source from head linear accelerator (LINAC) for Monte Carlo simulation is implemented. To achieve this aim, Prism dose calculation is compared with EGSnrc Monte Carlo simulation. Percentage depth dose (PDD) and R50 from both calculations are observed. BEAMnrc is simulated electron transport in LINAC head and produced phase space file. This file is used as DOSXYZnrc input to simulated electron transport in phantom. This study is started with commissioning process in water phantom. Commissioning process is adjusted Monte Carlo simulation with Prism RTPS. Commissioning result is used for study of inhomogeneity phantom. Physical parameters of inhomogeneity phantom that varied in this study are: density, location and thickness of tissue. Commissioning result is shown that optimum energy of Monte Carlo simulation for 6 MeV electron beam is 6.8 MeV. This commissioning is used R50 and PDD with Practical length (R{sub p}) as references. From inhomogeneity study, the average deviation for all case on interest region is below 5 %. Based on ICRU recommendations, Prism has good ability to calculate the radiation dose in inhomogeneity tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

07 ISOTOPE AND RADIATION SOURCES↗

Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of further calibration factors to be applied. The final accuracy of implantable MOSFETs when used for such kind of treatments was estimated to be within {+-}4%. Additional investigations using dose/fraction higher than 12 Gy, different beam configurations, and tracking systems could extend the present findings to other kind of treatments. MOSFET technology was proven to have high versatility in fast adaptation of existing detectors to new applications. It is plausible to expect a general feasibility of implantable MOSFET technology for in vivo dosimetry of the extracranial-targets treatments using the Cyberknife, provided each particular application will be validated by suitable both physical and clinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron Mixing and Isotropization in the Exhaust of Asymmetric Magnetic Reconnection With a Guide Field

In this work, we investigate an exhaust crossing of asymmetric guide field reconnection observed by Magnetospheric Multiscale (MMS) mission at Earth's dayside magnetopause. One MMS spacecraft (MMS 4) observes multicomponent electron distributions, including two counterstreaming electron beams, while the other three MMS spacecraft, with a separation of ~30 km, record nearly isotropic electron distributions. As counterstreaming electrons are unstable for the electron two-stream instability, our observations suggest that the electrostatic waves generated by the fast-growing electron two-stream instability can contribute to the rapid isotropization of electron distributions in the reconnection exhaust, indicating that wave-particle interactions play an important role in electron dynamics.

58 GEOSCIENCES↗

Ion Beam Extraction from Large Bore 11 to 13 GHz ECR Ion Source with a Pair of Cylindrically Comb-Shaped Magnetic Fields

We have developed a large bore electron cyclotron resonance (ECR) ion source with cylindrically comb-shaped magnetic field configuration to realize high current density and comparatively large bore ion beam which can be used for beam processes under low pressure and low microwave power. It is found that the plasma confinement of cylindrically comb-shaped magnetic fields is more effective than that of simple multipole magnetic fields. We have constructed a large bore ion beam extractor and set to the ECR ion source. The electron density attained to 10{sup 17{approx}}{sup 18} m{sup -3} order, ion saturation current density is about 80{approx}100 A/m{sup 2} under low pressure 0.03 Pa and low microwave power 200 W. We conduct the first trial of ion beam extraction from the ECR ion source. We investigate the ion beam characteristics for extraction voltages and Ar gas pressures. The extracted ion beam current increases in proportion to extraction voltages, however at present the beam current is lower than those estimated from ion saturation current. We observed the self-similar distribution of the extracted ion beam which is comparatively large bore. We are now investigating the ion beam extraction and going to optimize the electrode gap, the electrode position and shape of multi-holes of the extractor.

43 PARTICLE ACCELERATORS↗

TU-H-CAMPUS-TeP3-03: Dose Enhancement by Gold Nanoparticles Around the Bragg Peak of Proton Beams

Purpose: To make clear the spatial distribution of dose enhancement around gold nanoparticles (GNPs) located near the proton Bragg peak, and to evaluate the potential of GNPs as a radio sensitizer. Methods: The dose enhancement by electrons emitted from GNPs under proton irradiation was estimated by Geant4 Monte Carlo simulation toolkit in two steps. In an initial macroscopic step, 100 and 195 MeV proton beams were incident on a water cube, 30 cm on a side. Energy distributions of protons were calculated at four depths, 50% and 75% proximal to the Bragg peak, 100% peak, and 75% distal to the peak (P50, P75, Peak, and D75, respectively). In a subsequent microscopic step, protons with the energy distribution calculated above were incident on a 20 nm diameter GNP in a nanometer-size water box and the spatial distribution of dose around the GNP was determined for each energy distribution. The dose enhancement factor (DEF) was also deduced. Results: The dose enhancement effect was spread to several tens of nanometers in the both depth and radial directions. The enhancement area increased in the order of P50, P75, Peak, and D75 for both cases with 100 and 195 MeV protons. In every position around the Bragg peak, the 100 MeV beam resulted in a higher dose enhancement than the 195 MeV beam. At P75, the average and maximum DEF were 3.9 and 17.0 for 100 MeV, and 3.5 and 16.2 for 195 MeV, respectively. These results indicate that lower energy protons caused higher dose enhancement in this incident proton energy range. Conclusion: The dose enhancement around GNPs spread as the position in the Bragg peak region becomes deeper and depends on proton energy. It is expected that GNPs can be used as a radio sensitizer with consideration of the location and proton beam energy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-168: Characterization of Neutrons From the TrueBeam Treatment Head

Purpose: Calculate neutron production and transport in the TrueBeam treatment head, as input for vault design and phantom dose calculations. Methods: A detailed model of the treatment head, including shielding components off the beam axis, was created from manufacturer’s engineering drawings. Simulations were done with Geant4 for the 18X, 15X, 10X and 10FFF beams, tuned to match measured dose distributions inside the treatment field. Particles were recorded on a 70 cm radius sphere surrounding the treatment head enabling input into simulations of vaults. Results: For the 18X beam, 11×10{sup 9} neutrons/MU were observed. The energy spectrum was a broad peak with average energy 0.37 MeV. With jaws closed, 48% of the neutrons were generated in the primary collimator, 18% in the jaws, 12% in the target, and 10% in the flattening filter. With wide open jaws, few neutrons were produced in the jaws and consequently total neutron production dropped to 8.5×10{sup 9} neutrons/MU. Angular distributions were greatest along the beam axis (12×10{sup 9} neutrons/MU/sr, within 2 deg of the beam axis) and antiparallel to the beam axis (7×10{sup 9} neutrons/MU/sr). Peaks were observed in the neutron energy spectrum, corresponding to elastic scattering resonances in the shielding materials. Neutron production was lower for the other beams studied: 4.1×10{sup 9} neutrons/MU for 15X, 0.38×10{sup 9} neutrons/MU for 10X, and 0.22×10{sup 9} neutrons/MU for 10FFF. Despite dissimilar treatment head geometries and materials, the neutron production and energy spectrum were similar to those reported for Clinac accelerators. Conclusion: Detailed neutron production and leakage calculations for the TrueBeam treatment head were done. Unlike other studies, results are independent of the surrounding vault, enabling vault design calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stress distribution in and equivalent width of flanges of wide, thin-wall steel beams

The use of different forms of wide-flange, thin-wall steel beams is becoming increasingly widespread. Part of the information necessary for a national design of such members is the knowledge of the stress distribution in and the equivalent width of the flanges of such beams. This problem is analyzed in this paper on the basis of the theory of plane stress. As a result, tables and curves are given from which the equivalent width of any given beam can be read directly for use in practical design. An investigation is given of the limitations of this analysis due to the fact that extremely wide and thin flanges tend to curve out of their plane toward the neutral axis. A summary of test data confirms very satisfactorily the analytical results.

BEAMS, BOX-STRESSES↗

A Breakdown Criterion of Free Molecular Flows and an Optimum Analysis of EBPVD

Two important issues in electron beam physical vapor deposition (EBPVD) are addressed. The first issue is a validity condition of the classical cosine law widely used in the engineering context. This requires a breakdown criterion of the free molecular assumption on which the cosine law is established. Using the analytical solution of free molecular effusion flow, the number of collisions (N{sub c}) for a particle moving from an evaporative source to a substrate is estimated that is proven inversely proportional to the local Knudsen number at the evaporation surface. N{sub c} = 1 is adopted as a breakdown criterion of the free molecular assumption, and it is verified by experimental data and DSMC results. The second issue is how to realize the uniform distributions of thickness and component over a large-area thin film. Our analysis shows that at relatively low evaporation rates the goal is easy achieved through arranging the evaporative source positions properly and rotating the substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

Purpose: While Monte Carlo particle transport has proven useful in many areas (treatment head design, dose calculation, shielding design, and imaging studies) and has been particularly important for proton therapy (due to the conformal dose distributions and a finite beam range in the patient), the available general purpose Monte Carlo codes in proton therapy have been overly complex for most clinical medical physicists. The learning process has large costs not only in time but also in reliability. To address this issue, we developed an innovative proton Monte Carlo platform and tested the tool in a variety of proton therapy applications. Methods: Our approach was to take one of the already-established general purpose Monte Carlo codes and wrap and extend it to create a specialized user-friendly tool for proton therapy. The resulting tool, TOol for PArticle Simulation (TOPAS), should make Monte Carlo simulation more readily available for research and clinical physicists. TOPAS can model a passive scattering or scanning beam treatment head, model a patient geometry based on computed tomography (CT) images, score dose, fluence, etc., save and restart a phase space, provides advanced graphics, and is fully four-dimensional (4D) to handle variations in beam delivery and patient geometry during treatment. A custom-designed TOPAS parameter control system was placed at the heart of the code to meet requirements for ease of use, reliability, and repeatability without sacrificing flexibility. Results: We built and tested the TOPAS code. We have shown that the TOPAS parameter system provides easy yet flexible control over all key simulation areas such as geometry setup, particle source setup, scoring setup, etc. Through design consistency, we have insured that user experience gained in configuring one component, scorer or filter applies equally well to configuring any other component, scorer or filter. We have incorporated key lessons from safety management, proactively removing possible sources of user error such as line-ordering mistakes. We have modeled proton therapy treatment examples including the UCSF eye treatment head, the MGH stereotactic alignment in radiosurgery treatment head and the MGH gantry treatment heads in passive scattering and scanning modes, and we have demonstrated dose calculation based on patient-specific CT data. Initial validation results show agreement with measured data and demonstrate the capabilities of TOPAS in simulating beam delivery in 3D and 4D. Conclusions: We have demonstrated TOPAS accuracy and usability in a variety of proton therapy setups. As we are preparing to make this tool freely available for researchers in medical physics, we anticipate widespread use of this tool in the growing proton therapy community.

60 APPLIED LIFE SCIENCES↗

SU-E-T-589: A Comparison of Field Size Dependence of Electron Depth Dose From Different Linacs

Purpose: For accurate dose calculation in electron beam therapy, it is important to know the percentage depth dose (PDD) for each beam. This can vary depending on the machine make and model and the field size. Three different linear accelerators were compared in this study. Methods: PDD data was collected for different output beam energies and different field sizes for three different linear accelerators (Siemens Primus, Varian 2300ix, Varian Truebeam). Data was compared for the same energy with the same field size to see if the PDD differed among manufacturers. Furthermore, PDD was compared for different field sizes of the same machine at the same energy. Results: For the same beam energy and the same field size, the PDD curves were comparable for the three linacs with variations within 13%. PDD curves for different field sizes and beam energies were compared to verify this result. At higher beam energies, the disagreement between PDD curves is more pronounced between different field sizes for all three of the linacs compared. Conclusions: For the same energy and field size, the variation between different machines was within 13%. For the same manufacturer (Varian Clinac 2300ix and Truebeam), the agreement is within 3% with a standard deviation of less than 2.5%. PDD curves for different field sizes for the same energy were also investigated for the three linacs.

60 APPLIED LIFE SCIENCES↗

Fractionated Grid Therapy in Treating Cervical Cancers: Conventional Fractionation or Hypofractionation?

Purpose: To evaluate the conventionally fractionated and hypofractionated grid therapy in debulking cervical cancers using the linear quadratic (LQ) model. Methods and Materials: A Monte Carlo technique was used to calculate the dose distribution of a commercially available grid in a 6-MV photon beam. The LQ model was used to evaluate the therapeutic outcome of both the conventionally fractionated (2 Gy/fraction) and hypofractionated (15 Gy/fraction) grid therapy regimens to debulk cervical cancers with different LQ parameters. The equivalent open-field dose (EOD) to the cancer cells and therapeutic ratio (TR) were defined by comparing grid therapy with the open debulking field. The clinical outcomes from 114 patients were used to verify our theoretical model. Results: The cervical cancer and normal tissue cell survival statistics for grid therapy in two regimens were calculated. The EODs and TRs were derived. The EOD was only a fraction of the prescribed dose. The TR was dependent on the prescribed dose and the LQ parameters of both the tumor and normal tissue cells. The grid therapy favors the acutely responding tumors inside radiosensitive normal tissues. Theoretical model predictions were consistent with the clinical outcomes. Conclusions: Grid therapy provided a pronounced therapeutic advantage in both the hypofractionated and conventionally fractionated regimens compared with that seen with single fraction, open debulking field regimens, but the true therapeutic advantage exists only in the hypofractionated grid therapy. The clinical outcomes and our study indicated that a course of open-field radiotherapy is necessary to control tumor growth fully after a grid therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry

In some recent dosimetry protocols, plastic is allowed as a phantom material for the determination of an absorbed dose to water in electron beams, especially for low energy with beam qualities R{sub 50}<4 g/cm{sup 2}. In electron dosimetry with plastic, a depth-scaling factor, c{sub pl}, and a chamber-dependent fluence correction factor, h{sub pl}, are needed to convert the dose measured at a water-equivalent reference depth in plastic to a dose at a reference depth in water. The purpose of this study is to calculate correction factors for the use of plastic phantoms for clinical electron dosimetry using the EGSnrc Monte Carlo code system. RMI-457 and WE-211 were investigated as phantom materials. First the c{sub pl} values for plastic materials were calculated as a function of a half-value depth of maximum ionization, I{sub 50}, in plastic. The c{sub pl} values for RMI-457 and WE-211 varied from 0.992 to 1.002 and from 0.971 to 0.979, respectively, in a range of nominal energies from 4 MeV to 18 MeV, and varied slightly as a function of I{sub 50} in plastic. Since h{sub pl} values depend on the wall correction factor, P{sub wall}, of the chamber used, they are evaluated using a pure electron fluence correction factor, {phi}{sub pl}{sup w}, and P{sub wall}{sup w} and P{sub wall}{sup pl} for a combination of water or plastic phantoms and plane-parallel ionization chambers (NACP-02, Markus and Roos). The {phi}{sub pl}{sup w} and P{sub wall} (P{sub wall}{sup w} and P{sub wall}{sup pl}) values were calculated as a function of the water-equivalent depth in plastic materials and at a reference depth as a function of R{sub 50} in water, respectively. The {phi}{sub pl}{sup w} values varied from 1.024 at 4 MeV to 1.013 at 18 MeV for RMI-457, and from 1.025 to 1.016 for WE-211. P{sub wall}{sup w} values for plane-parallel chambers showed values in the order of 1.5% to 2% larger than unity at 4 MeV, consistent with earlier results. The P{sub wall}{sup pl} values of RMI-457 and WE-211 were close to unity for all the energy beams. Finally, calculated h{sub pl} values of RMI-457 ranged from 1.009 to 1.005, from 1.010 to 1.003 and from 1.011 to 1.007 for NACP-02, Markus and Roos chambers, respectively, in the range of 4 MeV to 18 MeV, and the values of WE-211 were 1.010 to 1.004, 1.010 to 1.004 and 1.012 to 1.008, respectively. The calculated h{sub pl} values for the Markus chamber agreed within their combined uncertainty with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gluon saturation in a saturated environment

A bootstrap equation for self-quenched gluon shadowing leads to a reduced magnitude of broadening for partons propagating through a nucleus. Saturation of small-x gluons in a nucleus, which has the form of transverse momentum broadening of projectile gluons in pA collisions in the nuclear rest frame, leads to a modification of the parton distribution functions in the beam compared with pp collisions. In nucleus-nucleus collisions all participating nucleons acquire enhanced gluon density at small x, which boosts further the saturation scale. Solution of the reciprocity equations for central collisions of two heavy nuclei demonstrate a significant, up to several times, enhancement of Q{sub sA}{sup 2}, in AA compared with pA collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical wavelength converters for photonic band gap microcircuits

We demonstrate compact optical wavelength conversion architecture for picosecond laser pulses and data streams within photonic band gap waveguides. These multimode waveguides are seeded with resonantly driven, inhomogeneously broadened, distributions of quantum dots whose optical transition center frequency is placed near a sharp discontinuity in the local (electromagnetic) density of states (LDOS). This discontinuity is provided by a cutoff in one of the waveguide modes. Wavelength conversion of an optical pulse propagating in the single-mode spectral range of the waveguide, near the LDOS jump, is provided by a steady-state holding field with frequency matched to the center frequency of the quantum dot distribution. In the absence of an incident laser pulse, the holding field is absorbed by the quantum dots. When the incident pulse intensity is sufficient to cause population inversion of a suitable fraction of the quantum dots, the holding field is amplified and the incident pulse profile is imprinted on to the holding field, leading to wavelength conversion in the range of 3-20 nm at wavelengths near 1.5 {mu}m. Larger wavelength shifts typically require higher power levels for operation (milliwatt scale) but enable conversion of shorter (picosecond) pulses. Small wavelength shifts typically require narrower distribution of quantum dot resonance frequencies. Using finite-difference time-domain simulations, we show that an optical pulse (Gaussian in time) can create another equivalent optical pulse with either higher or lower center frequency inside the photonic band gap of the structure. Optical pulses of a given center frequency can also be selectively amplified or absorbed depending on the coincident arrival of another laser pulse with different center frequency, enabling all-optical logic operations within a multiwavelength-channel optical circuit.

77 NANOSCIENCE AND NANOTECHNOLOGY↗