Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

How Much Are We Saving after All? Characterizing the Effects of Commonly Varying Assumptions on Emissions and Damage Estimates in PJM

In recent years, several methods have emerged to estimate the emissions and health, environmental, and climate change damages avoided by interventions such as energy efficiency, demand response, and the integration of renewables. However, differing assumptions employed in these analyses could yield contradicting recommendations regarding intervention implementation. We test the magnitude of the effect of using different key assumptions—average vs marginal emissions, year of calculation, temporal and regional scope, and inclusion of nonemitting generation—to estimate Mid-Atlantic region power pool (PJM) emissions and damage factors. We further highlight the importance of factor selection by evaluating three illustrative 2017 power system examples in PJM. We find that for a simple building lighting intervention, using average emissions factors incorporating nonemitting generation underestimates avoided damages by 45% compared to marginal factors. For PJM demand response, outdated marginal emissions factors from 2016 overestimate avoided damages by 25% compared to 2017 factors. Our assessment of PJM summer load further suggests that fossil-only average emissions factors overestimate damages by 63% compared to average factors incorporating nonemitting generation. Here, we recommend that energy modelers carefully select appropriate emissions metrics when performing their analyses. Furthermore, since the U.S. electric grid is rapidly changing, we urge decision-makers to frequently update (and consider forecasting) grid emissions factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling Stationary Lithium-Ion Batteries for Optimization and Predictive Control

Accurately modeling stationary battery storage behavior is crucial to understand and predict its limitations in demand-side management scenarios. In this paper, a lithium-ion battery model was derived to estimate lifetime and state-of-charge for building-integrated use cases. The proposed battery model aims to balance speed and accuracy when modeling battery behavior for real-time predictive control and optimization. In order to achieve these goals, a mixed modeling approach was taken, which incorporates regression fits to experimental data and an equivalent circuit to model battery behavior. A comparison of the proposed battery model output to actual data from the manufacturer validates the modeling approach taken in the paper. Additionally, a dynamic test case demonstrates the effects of using regression models to represent internal resistance and capacity fading.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MEBT Laser Notcher (Chopper) for Booster Loss Reduction

The Fermilab Booster, which utilizes multi-turn injection and adiabatic capture, the extraction gap (aka "notch") has been created in the ring at injection energy using fast kickers which deposit the beam in a shielded absorber within the accelerator tunnel. This process, while effective at creating the extraction notch, was responsible for a significant fraction of the total beam power loss in the Booster tunnel and created significant residual activation within the Booster tunnel in the absorber region and beyond. With increasing beam demand from the Experimental Program, the Fermilab Proton Improvement Plan (PIP) initiated an R&D project to build a laser system to create the notch within a linac beam pulse at 750 keV, where activation in not an issue. This talk will discuss moving from R&D to an operational laser system and its integration into the accelerator complex. We will also cover the loss reduction in the Booster, increased efficiency, and increased proton throughput. We will touch on other potential applications for this bunch-by-bunch neutralization approach.

43 PARTICLE ACCELERATORS↗

Distributed Generation Market Demand Model (dGen): Documentation

The Distributed Generation Market Demand model (dGen) is a geospatially rich, bottom-up, market-penetration model that simulates the potential adoption of distributed energy resources (DERs) for residential, commercial, and industrial entities in the continental United States through 2050. The National Renewable Energy Laboratory (NREL) developed dGen to analyze the key factors that will affect future market demand for distributed solar, wind, storage, and other DER technologies in the United States. The new model builds off, extends, and replaces NREL's SolarDS model (Denholm et al. 2009a), which simulates the market penetration of distributed PV only. Unlike the SolarDS model, dGen can model various DER technologies under one platform--it currently can simulate the adoption of distributed solar (the dSolar module) and distributed wind (the dWind module) and link with the ReEDS capacity expansion model (Appendix C). The underlying algorithms and datasets in dGen, which improve the representation of customer decision making as well as the spatial resolution of analyses (Figure ES-1), also are improvements over SolarDS.

17 WIND ENERGY↗

Load Forecasting for the Moroccan Electricity Sector

The Moroccan electricity sector is undergoing rapid transformation as it seeks to increase its utilization of renewable energy from its abundant domestic supply. Key to implementing variable renewable energy is understanding current electricity demand and forecasting this demand on the long, medium, and short timescales. This report leverages existing Moroccan electricity sector data to build basic load forecasts on these timescales. Taking these forecasts, the report recommends next steps in terms of additional algorithms, mathematical models, data collection, and scenarios (such as vehicle electrification or high levels of distributed generation) that should be examined for advanced load forecasts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Innovative Technologies for a Low Carbon Electricity System

The electricity sector represents the centerpiece of decarbonization pathways for the state. Decrease in the cost of renewable electricity generation, combined with ample solar energy, wind and other renewable resources, presents a realistic way to achieve electricity generation that is nearly free of CO 2 emissions by mid-century. Expansion of renewable electricity supply could allow replacement of many CO 2 -emitting technologies with ones that use electricity—in transportation, buildings, and possibly industry. Key elements of the path for California’s electricity sector are: restrain electricity demand through higher efficiency, rapidly expand renewable electricity generation, develop electricity storage to complement renewable electricity, manage flexible electricity loads for a low-carbon electricity system, electrify where appropriate to reduce CO 2 emissions, and maintain reliable and resilient electricity supply. This report provides an overview of a multitude of innovative technologies in each of the above areas that have the potential to help the state meet its decarbonization goals, while lowering costs and promoting greater reliability. The information presented provides a portrait of the landscape of technology innovation that can help policymakers, state agencies, and interested parties develop strategies to meet the state’s goals and to target efforts to support and nurture technology innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Surrogate Modeling of Landau Damping with Deep Operator Networks

Kinetic simulations excel at capturing microscale plasma physics phenomena with high accuracy, but their computational demands make them impractical for modeling large-scale space and astrophysical systems. In this context, we build a surrogate model, using Deep Operator Networks (DeepONets), based upon the Vlasov–Poisson simulation data to model the dynamical evolution of plasmas, focusing on the Landau damping process—a fundamental kinetic phenomenon in space and astrophysical plasmas. The trained DeepONets are able to capture the evolution of electric field energy in both linear and nonlinear regimes under various conditions. Extensive validation highlights DeepONets’ robust performance in reproducing complex plasma behaviors with high accuracy, paving the way for large-scale modeling of space and astrophysical plasmas.

plasma astrophysics↗

Developing structures technology for the day after tomorrow.

To prepare for new demands on aircraft structures, NASA has established a number of goals. These include automatic analysis and design, building confidence in advanced composites, improving the technology base for future supersonic and hypersonic vehicles, validating concepts for active controls, developing methods for predicting aircraft loads and aeroelasticity, and generating design methods for assuring structural integrity. Progress made in achieving these goals is discussed in detail.

Brooks, G. W.↗

Programs Automate Complex Operations Monitoring

Kennedy Space Center, just off the east coast of Florida on Merritt Island, has been the starting place of every human space flight in NASA s history. It is where the first Americans left Earth during Project Mercury, the terrestrial departure point of the lunar-bound Apollo astronauts, as well as the last solid ground many astronauts step foot on before beginning their long stays aboard the International Space Station. It will also be the starting point for future NASA missions to the Moon and Mars and temporary host of the new Ares series rockets designed to take us there. Since the first days of the early NASA missions, in order to keep up with the demands of the intricate and critical Space Program, the launch complex - host to the large Vehicle Assembly Building, two launch pads, and myriad support facilities - has grown increasingly complex to accommodate the sophisticated technologies needed to manage today s space missions. To handle the complicated launch coordination safely, NASA found ways to automate mission-critical applications, resulting in streamlined decision-making. One of these methods, management software called the Control Monitor Unit (CMU), created in conjunction with McDonnell Douglas Space & Defense Systems, has since left NASA, and is finding its way into additional applications.

Source record↗

Compare Energy Use in Variable Refrigerant Flow Heat Pumps Field Demonstration and Computer Model

Variable Refrigerant Flow (VRF) heat pumps are often regarded as energy efficient air-conditioning systems which offer electricity savings as well as reduction in peak electric demand while providing improved individual zone setpoint control. One of the key advantages of VRF systems is minimal duct losses which provide significant reduction in energy use and duct space. However, there is limited data available to show their actual performance in the field. Since VRF systems are increasingly gaining market share in the US, it is highly desirable to have more actual field performance data of these systems. An effort was made in this direction to monitor VRF system performance over an extended period of time in a US national lab test facility. Due to increasing demand by the energy modeling community, an empirical model to simulate VRF systems was implemented in the building simulation program EnergyPlus. This paper presents the comparison of energy consumption as measured in the national lab and as predicted by the program. For increased accuracy in the comparison, a customized weather file was created by using measured outdoor temperature and relative humidity at the test facility. Other inputs to the model included building construction, VRF system model based on lab measured performance, occupancy of the building, lighting/plug loads, and thermostat set-points etc. Infiltration model inputs were adjusted in the beginning to tune the computer model and then subsequent field measurements were compared to the simulation results. Differences between the computer model results and actual field measurements are discussed. The computer generated VRF performance closely resembled the field measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing Electric Grid System Benefits of MPC-Based Residential Load Shaping: Preprint

Routinely encouraging and discouraging residential electric load throughout the day will be increasingly critical in efficiently managing the smart grid to reliably deliver clean, low-cost electricity. Yet, manipulating the duty cycles of thermostatically controlled loads such as heating, air conditioning, and hot water heaters can have the effect of destabilizing or stabilizing the grid. This work explores the potential for price-responsive control of residential air conditioning to shape electric demand at the distribution feeder level to minimize electricity production costs. Physical models of the interplay between building thermal and electric loads are used to Simulate time-series temperature and load behavior. Instantaneous load-adding and load-shedding opportunities are quantified in more than 100,000 individual homes on 204 distribution feeders with results presented for 35 cities across the United States. In the context of distributed model predictive control, simulation of feeder-level response to a residential day-ahead 5-minute pricing vector to 2,146 homes highlights an aggregate impact of flexible loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

Solar San Diego: The Impact of Binomial Rate Structures on Real PV-Systems

There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rates structures is presented. The data revealed that actual demand and energy use benefits of bionomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007. Future work will include combining demand and electricity charges and increasing the breadth of rate structures tested, including the impacts of non-coincident demand charges.

14 SOLAR ENERGY↗

Solar San Diego: The Impact of Binomial Rate Structures on Real PV Systems; Preprint

There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rate structures is presented. The data revealed that actual demand and energy use benefits of binomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007.

14 SOLAR ENERGY↗

Building Energy Codes and Grid-Interactive Efficient Buildings: How building energy codes can enable a more dynamic and energy-efficient built environment

This report considers the role of national model codes to promote grid-interactive efficient buildings (GEBs) as part of the modernization of the U.S. electricity grid. It introduces GEBs, describes their ability to support a clean, resilient grid, and considers challenges and approaches for incorporating GEB measures into national model energy codes and standards. Desirable traits of GEB include being low energy, low peaking, and responsive to grid needs, and minimizing the curtailment of renewable energy resources. In addition, the future grid incurs a time and locational value on these types of building services. Accounting for these considerations in future code development requires a continuation and expansion of code-minimum energy efficiency requirements and inclusion of demand responsive and load flexibility measures while ensuring annual use and cost reductions. Also, efforts to include GEB measures in codes will be limited until they are fully developed into an American National Standards Institute (ANSI)-approved standard. Then it would be straightforward to address GEB measures through points or packages and/or scoring requirements. Otherwise, the building code would have to describe each specific grid responsive strategy. This document reviews topics pertinent to considering codes in this context. Specifically, the study presents the status and direction of current building energy codes, the future smart grid, low-energy buildings, and grid-integrated buildings. The report concludes with recommendations for future code development activities to support low-energy, grid-interactive buildings in order to provide added value to building owners, the grid, and society.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Home Energy Management Systems: The Impact of Their Proliferation on the Electric Grid

Approximately 100 million singlefamily homes in the United States account for 36% of the electricity load, and often they determine the peak system load, especially on hot summer days when residential air-conditioning use is high. Traditional building power profiles are changing. Currently, there is an increased use of energy-efficient building materials and designs, which decreases building loads. In addition, there is an increased adoption of rooftop solar photovoltaic (PV), which leads to bidirectional power flow and significant power ramps as PV output decreases in the late afternoon. Building power profiles are likely to change even more as residential energy storage products proliferate. Therefore, a better understanding of residential electricity demand is key to addressing the envisioned transition of the electric power system from its traditional structure to one that is transactive.

25 ENERGY STORAGE↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗