Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Performance evaluation of an agent-based occupancy simulation model

Occupancy is an important factor driving building performance. Static and homogeneous occupant schedules, commonly used in building performance simulation, contribute to issues such as performance gaps between simulated and measured energy use in buildings. Stochastic occupancy models have been recently developed and applied to better represent spatial and temporal diversity of occupants in buildings. However, there is very limited evaluation of the usability and accuracy of these models. This study used measured occupancy data from a real office building to evaluate the performance of an agent-based occupancy simulation model: the Occupancy Simulator. The occupancy patterns of various occupant types were first derived from the measured occupant schedule data using statistical analysis. Then the performance of the simulation model was evaluated and verified based on (1) whether the distribution of observed occupancy behavior patterns follows the theoretical ones included in the Occupancy Simulator, and (2) whether the simulator can reproduce a variety of occupancy patterns accurately. Results demonstrated the feasibility of applying the Occupancy Simulator to simulate a range of occupancy presence and movement behaviors for regular types of occupants in office buildings, and to generate stochastic occupant schedules at the room and individual occupant levels for building performance simulation. For future work, model validation is recommended, which includes collecting and using detailed interval occupancy data of all spaces in an office building to validate the simulated occupant schedules from the Occupancy Simulator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide to Energy Audits

Energy audits are a powerful tool for uncovering operational and equipment improvements that will save energy, reduce energy costs, and lead to higher performance. Energy audits can be done as a stand-alone effort or as part of a larger analysis across a group of facilities, or across an owner's portfolio. The purpose of an energy audit (sometimes called an 'energy assessment' or 'energy study') is to determine where, when, why and how energy is used in a facility, and to identify opportunities to improve efficiency. Energy auditing services are offered by energy services companies (ESCOs), energy consultants and engineering firms. The energy auditor leads the audit process but works closely with building owners, staff and other key participants throughout to ensure accuracy of data collection and appropriateness of energy efficiency recommendation. The audit typically begins with a review of historical and current utility data and benchmarking of your building's energy use against similar buildings. This sets the stage for an onsite inspection of the physical building. The main outcome of an energy audit is a list of recommended energy efficiency measures (EEMs), their associated energy savings potential, and an assessment of whether EEM installation costs are a good financial investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Infiltration modeling guidelines for commercial building energy analysis

This report presents a methodology for modeling air infiltration in EnergyPlus to account for envelope air barrier characteristics. Based on a review of various infiltration modeling options available in EnergyPlus and sensitivity analysis, the linear wind velocity coefficient based on DOE-2 infiltration model is recommended. The methodology described in this report can be used to calculate the EnergyPlus infiltration input for any given building level infiltration rate specified at known pressure difference. The sensitivity analysis shows that EnergyPlus calculates the wind speed based on zone altitude, and the linear wind velocity coefficient represents the variation in infiltration heat loss consistent with building location and weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raising the Rent Premium: Moving Green Building Research Beyond Certifications and Rent

Advocates for high-performing, energy efficient buildings understand the hurdles to proving the business case to spur development and investment decisions among commercial real estate owners and investors. Although there is significant evidence that green buildings exhibit increased financial performance via decreased operating expenses and non-energy benefits such as workplace comfort and employee productivity, green building practitioners still face an uphill battle when asked to prove the profits, most frequently pointing to rent premium as an indicator to attract investment. This paper documents a recently conducted literature review commissioned by the US Department of Energy (DOE) of 39 peer-reviewed and published academic papers pertaining to green or energy-related building attributes and financial performance. The review (first published here) indicated that 27 papers found a positive correlation between green building certifications and rents. If this is the case, then why are green building development and energy efficiency retrofits not the norm for the industry? This paper first synthesizes the recent literature review to illustrate that the existing body of empirical evidence supports green building investment. Next, it describes a workshop of leading academics in real estate sustainability and finance who met in late 2017 to discuss gaps in green building research and assess data challenges in their fields. Insights synthesized the workshop were used to drive new DOE led research that can provide value and understanding to investors and builders of high performing buildings. Finally, the paper offers insights into why the market is not properly pricing building efficiency, with factors ranging from improper mitigation of risks associated with energy and lack of transparency and responsibility felt by building end users, and what further steps are needed to transform green building investment practices in the commercial real estate industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗

ACTIVE

The Automated Control Testbed for Integration, Verification, and Emulation (ACTIVE) framework is a software platform designed to support the optimized operation and management of a wide range of building types. It enables the development, testing, and validation of diverse control strategies, including AI-based, rule-based, and model-based approaches. The platform facilitates a seamless transition from simulation-based evaluation of control strategies to real-world field validation and deployment. ACTIVE supports the full building management lifecycle, encompassing data acquisition and management, system monitoring, optimized control, adaptive learning services, device dispatch and coordination, as well as advanced analytics and visualization. Together, these capabilities provide an integrated environment for improving building performance, operational efficiency, reducing energy cost, and reliability.

Smith, Robert [Oak Ridge National Laboratory (ORNL↗

Mortar: An open testbed for portable building analytics

Access to large amounts of real-world data has long been a barrier to the development and evaluation of analytics applications for the built environment. Open data sets exist, but they are limited in their span (how much data is available) and context (what kind of data is available and how it is described). Evaluation of such analytics is also limited by how the analytics themselves are implemented, often using hard-coded names of building components, points and locations, or unique input data formats. To advance the methodology for how such analytics are implemented and evaluated, we present Mortar: an open testbed for portable building analytics, currently spanning 90 buildings and containing over 9.1 billion data points. All buildings in the testbed are described using Brick, a recently developed metadata schema, providing rich functional descriptions of building assets and subsystems. We also propose a simple architecture for writing portable analytics applications that are robust to the diversity of buildings and can configure themselves based on context. We demonstrate the utility of Mortar by implementing 11 applications from the literature.

data set↗

Developing and tuning a community scale energy model for a disadvantaged community

This work describes the development of a community-scale energy model for a mixed-use low-income community located in Huntington Beach, CA. An accurate community-scale energy model is useful for evaluating the use of limited capital resources used to invest in clean energy technologies. This work lays out the process of developing such a model while relying primarily on publicly available data and highlighting critical partnerships necessary for model development success. The primary contribution of this work is the demonstration of the process used to develop an accurate energy model for a disadvantaged community when minimal building and energy use data is available. The heart of the model is the physics-based community scale energy modeling platform URBANopt. Using a bottom-up load modeling approach, energy simulated energy use falls within 3% or less of aggregate annual utility data, and within 10% or less aggregate monthly utility data. The demonstrated model development and tuning process can be used by others to characterize other atypical communities, which may differ significantly from prototypical models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FRMAC Laboratory Analysis RadResponder Gap Analysis and Web Portal Enhancements

The Federal Radiological Monitoring and Assessment Center (FRMAC) relies on accurate and defensible analytical laboratory data to support its mission. FRMAC Laboratory Analysis personnel are responsible for (1) receiving samples, (2) managing samples, and (3) providing data quality assurance. Currently, the RadResponder software application does not meet all these needs. With some modifications, RadResponder could meet the needs for sample receiving functions, but it does not meet the needs of sample management and data quality assurance functions. The FRMAC Laboratory Analysis team has discussed and reviewed the following options moving forward: Option 1: Make minor revisions to RadResponder to improve sample receiving capability, purchase and configure a commercial laboratory information management system (LIMS) to perform sample management and data quality assurance, and build an interface between RadResponder and the commercial-off-the-shelf LIMS. Option 2: Make major revisions to RadResponder for all FRMAC Laboratory Analysis functions to support required sample management and data quality assurance activities. Option 3: Create a custom-built LIMS system to interface with RadResponder. Note: All three options will require the development of a Laboratory Analysis web portal and will require funding for ongoing maintenance and training. The FRMAC Laboratory Analysis team highly recommends Option 1 as the best and most efficient path forward. Commercial-off-the-shelf LIMS products have been proven successful in the laboratory community for decades. Option 1 leverages these proven technologies and takes advantage of RadResponder's current strengths.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online anomaly detection for multi‐source VMware using a distributed streaming framework

Summary Anomaly detection refers to the identification of patterns in a dataset that do not conform to expected patterns. Such non‐conformant patterns typically correspond to samples of interest and are assigned to different labels in different domains, such as outliers, anomalies, exceptions, and malware. A daunting challenge is to detect anomalies in rapid voluminous streams of data. This paper presents a novel, generic real‐time distributed anomaly detection framework for multi‐source stream data. As a case study, we investigate anomaly detection for a multi‐source VMware‐based cloud data center, which maintains a large number of virtual machines (VMs). This framework continuously monitors VMware performance stream data related to CPU statistics (e.g., load and usage). It collects data simultaneously from all of the VMs connected to the network and notifies the resource manager to reschedule its CPU resources dynamically when it identifies any abnormal behavior from its collected data. A semi‐supervised clustering technique is used to build a model from benign training data only. During testing, if a data instance deviates significantly from the model, then it is flagged as an anomaly. Effective anomaly detection in this case demands a distributed framework with high throughput and low latency. Distributed streaming frameworks like Apache Storm, Apache Spark, S4, and others are designed for a lower data processing time and a higher throughput than standard centralized frameworks. We have experimentally compared the average processing latency of a tuple during clustering and prediction in both Spark and Storm and demonstrated that Spark processes a tuple much quicker than storm on average. Copyright © 2016 John Wiley & Sons, Ltd.

Solaimani, Mohiuddin↗

Building a Cyberinfrastructure for Environmental System Science: Modeling Frameworks, Data Management, and Scientific Workflows, Workshop Report, Potomac, Maryland, April 30-May 1, 2015

The Environmental System Science (ESS) activity within the Department of Energy’s (DOE) Office of Biological and Environmental Research (BER) seeks to advance a robust, predictive understanding of terrestrial environments, extending from bedrock to the top of the vegetative canopy and from molecular to global scales, through an iterative cycle of model-driven experimentation and observation dubbed MODEX. Considerable progress has been made toward achieving this overarching goal, but widely recognized is the fragmentation across projects and disciplines of the relevant modeling and simulation capabilities, observational and experimental data, analysis algorithms, and workflow tools. This fragmentation creates significant challenges for studying impacts and feedbacks in these complex multiscale systems. These challenges are further exacerbated by ongoing disruptive changes in high-performance computational architectures and the exponential growth in the types and volume of data that render obsolete the conventional approaches to software development and data management. Overcoming these challenges will require the development of a BER Climate and Environmental Sciences Division (CESD)–wide enabling cyberinfrastructure to support data management, cross-domain modeling, data analysis, and collaborative research. To explore the potential for working groups to initiate and guide a more integrated and community-based cyberinfrastructure, BER held the ESS Workshop on Model-Data Integration: Modeling Frameworks, Data Management, and Scientific Workflows on April 30-May 1, 2015, following the ESS Principal Investigator Meeting in Potomac, Maryland. Participants included model developers, software engineers, and data management specialists from eight national laboratories, which represented a wide range of projects and programs from CESD as well as cross-cutting projects from DOE’s Office of Advanced Scientific Computing Research (ASCR; both BER and ASCR are operated from within DOE’s Office of Science). A series of plenary talks provided background information and clarified the workshop’s three objectives: (1) develop requirements for this community-based cyberinfrastructure to ensure enhanced scientific productivity of the community as a whole; (2) identify challenges associated with developing this new cyberinfrastructure using a phased approach guided by project-driven use cases; and, given these requirements and challenges, (3) chart a path forward for ESS working groups to lead the phased development of the new cyberinfrastructure.

54 ENVIRONMENTAL SCIENCES↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

This report describes example applications and considerations for using the National Renewable Energy Lab’s ResStock and ComStock end use load profiles (EULP). The report begins with an introduction to the three year project, and then provides instructions on accessing the EULP data and considerations for using the EULP and limitations of the data. The remainder of the report is on EULP use cases, including a variety of electricity planning use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Network Equipment Energy Use and Savings Potential in Buildings

Network connectivity has become nearly ubiquitous, and the energy use of the equipment required for this connectivity is growing. Network equipment consists of devices that primarily switch and route Internet Protocol (IP) packets from a source to a destination, and this category specifically excludes edge devices like PCs, servers and other sources and sinks of IP traffic. This paper presents the results of a study of network equipment energy use and includes case studies of networks in a campus, a medium commercial building, and a typical home. The total energy use of network equipment is the product of the stock of equipment in use, the power of each device, and their usage patterns. This information was gathered from market research reports, broadband market penetration studies, field metering, and interviews with network administrators and service providers. We estimate that network equipment in the USA used 18 TWh, or about 1percent of building electricity, in 2008 and that consumption is expected to grow at roughly 6percent per year to 23 TWh in 2012; world usage in 2008 was 51 TWh. This study shows that office building network switches and residential equipment are the two largest categories of energy use consuming 40percent and 30percent of the total respectively. We estimate potential energy savings for different scenarios using forecasts of equipment stock and energy use, and savings estimates range from 20percent to 50percent based on full market penetration of efficient technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗