Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Do Intermediate Radiation Doses Contribute to Late Rectal Toxicity? An Analysis of Data From Radiation Therapy Oncology Group Protocol 94-06

Purpose: To investigate whether the volumes of rectum exposed to intermediate doses, from 30 to 50 Gy, contribute to the risk of Grade {>=}2 late rectal toxicity among patients with prostate cancer receiving radiotherapy. Methods and Materials: Data from 1009 patients treated on Radiation Therapy Oncology Group protocol 94-06 were analyzed using three approaches. First, the contribution of intermediate doses to a previously published fit of the Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model was determined. Next, the extent to which intermediate doses provide additional risk information, after taking the LKB model into account, was investigated. Third, the proportion of rectum receiving doses higher than a threshold, VDose, was computed for doses ranging from 5 to 85 Gy, and a multivariate Cox proportional hazards model was used to determine which of these parameters were significantly associated with time to Grade {>=}2 late rectal toxicity. Results: Doses <60 Gy had no detectable impact on the fit of the LKB model, as expected on the basis of the small estimate of the volume parameter (n = 0.077). Furthermore, there was no detectable difference in late rectal toxicity among cohorts with similar risk estimates from the LKB model but with different volumes of rectum exposed to intermediate doses. The multivariate Cox proportional hazards model selected V75 as the only value of VDose significantly associated with late rectal toxicity. Conclusions: There is no evidence from these data that intermediate doses influence the risk of Grade {>=}2 late rectal toxicity. Instead, the critical doses for this endpoint seem to be {>=}75 Gy. It is hypothesized that cases of Grade {>=}2 late rectal toxicity occurring among patients with V75 less than approximately 12% may be due to a 'background' level of risk, likely due mainly to biological factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Algorithms Used in Heterogeneous Dose Calculations Show Systematic Differences as Measured With the Radiological Physics Center's Anthropomorphic Thorax Phantom Used for RTOG Credentialing

Purpose: To determine the impact of treatment planning algorithm on the accuracy of heterogeneous dose calculations in the Radiological Physics Center (RPC) thorax phantom. Methods and Materials: We retrospectively analyzed the results of 304 irradiations of the RPC thorax phantom at 221 different institutions as part of credentialing for Radiation Therapy Oncology Group clinical trials; the irradiations were all done using 6-MV beams. Treatment plans included those for intensity-modulated radiation therapy (IMRT) as well as 3-dimensional conformal therapy (3D-CRT). Heterogeneous plans were developed using Monte Carlo (MC), convolution/superposition (CS), and the anisotropic analytic algorithm (AAA), as well as pencil beam (PB) algorithms. For each plan and delivery, the absolute dose measured in the center of a lung target was compared to the calculated dose, as was the planar dose in 3 orthogonal planes. The difference between measured and calculated dose was examined as a function of planning algorithm as well as use of IMRT. Results: PB algorithms overestimated the dose delivered to the center of the target by 4.9% on average. Surprisingly, CS algorithms and AAA also showed a systematic overestimation of the dose to the center of the target, by 3.7% on average. In contrast, the MC algorithm dose calculations agreed with measurement within 0.6% on average. There was no difference observed between IMRT and 3D CRT calculation accuracy. Conclusion: Unexpectedly, advanced treatment planning systems (those using CS and AAA algorithms) overestimated the dose that was delivered to the lung target. This issue requires attention in terms of heterogeneity calculations and potentially in terms of clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of High Ipsilateral Subventricular Zone Radiation Therapy Dose in Glioblastoma: A Pooled Analysis

Purpose: Cancer stem cells (CSCs) may play a role in the recurrence of glioblastoma. They are believed to originate from neural stem cells in the subventricular zone (SVZ). Because of their radioresistance, we hypothesized that high doses of radiation (>59.4 Gy) to the SVZ are necessary to control CSCs and improve progression-free survival (PFS) or overall survival (OS) in glioblastoma. Methods and Materials: 173 patients with glioblastoma pooled from 2 academic centers were treated with resection followed by chemoradiation therapy. The SVZ was segmented on computed tomography to calculate radiation doses delivered to the presumptive CSC niches. The relationships between high SVZ doses and PFS and OS were examined using Cox proportional hazards models. Five covariates were included to estimate their impact on PFS or OS: ipsilateral and contralateral SVZ doses, clinical target volume dose, age, and extent of resection. Results: Median PFS and OS were 10.4 and 19.6 months for the cohort. The mean ipsilateral SVZ, contralateral SVZ, and clinical target volume doses were 49.2, 35.2, and 60.1 Gy, respectively. Twenty-one patients who received high ipsilateral SVZ dose (>59.4 Gy) had significantly longer median PFS (12.6 vs 9.9 months, P=.042) and longer OS (25.8 vs 19.2 months, P=.173). On multivariate analysis, high radiation therapy doses to ipsilateral SVZ remained a statistically significant independent predictor of improved PFS but not of OS. The extent of surgery affected both PFS and OS on multivariate analysis. Conclusion: High radiation therapy doses to ipsilateral CSC niches are associated with improved PFS in glioblastoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were {sup 60}Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors for Neovascular Glaucoma After Proton Beam Therapy of Uveal Melanoma: A Detailed Analysis of Tumor and Dose–Volume Parameters

Purpose: To determine neovascular glaucoma (NVG) incidence and identify contributing tumor and dosing factors in uveal melanoma patients treated with proton beam radiation therapy (PBRT). Methods and Materials: A total of 704 PBRT patients treated by a single surgeon (DHC) for uveal melanoma (1996-2010) were reviewed for NVG in our prospectively maintained database. All patients received 56 GyE in 4 fractions. Median follow-up was 58.3 months. Analyses included the Kaplan-Meier method to estimate NVG distributions, univariate log–rank tests, and Cox's proportional hazards multivariate analysis using likelihood ratio tests to identify independent risk factors of NVG among patient, tumor, and dose–volume histogram parameters. Results: The 5-year PBRT NVG rate was 12.7% (95% confidence interval [CI] 10.2%-15.9%). The 5-year rate of enucleation due to NVG was 4.9% (95% CI 3.4%-7.2%). Univariately, the NVG rate increased significantly with larger tumor diameter (P<.0001), greater height (P<.0001), higher T stage (P<.0001), and closer proximity to the disc (P=.002). Dose–volume histogram analysis revealed that if >30% of the lens or ciliary body received ≥50% dose (≥28 GyE), there was a higher probability of NVG (P<.0001 for both). Furthermore, if 100% of the disc or macula received ≥28 GyE, the NVG rate was higher (P<.0001 and P=.03, respectively). If both anterior and posterior doses were above specified cut points, NVG risk was highest (P<.0001). Multivariate analysis confirmed significant independent risk factors to include tumor height (P<.0001), age (P<.0001), %disc treated to ≥50% Dose (<100% vs 100%) (P=.0007), larger tumor diameter (P=.01), %lens treated to ≥90% Dose (0 vs >0%-30% vs >30%) (P=.01), and optic nerve length treated to ≥90% Dose (≤1 mm vs >1 mm) (P=.02). Conclusions: Our current PBRT patients experience a low rate of NVG and resultant enucleation compared with historical data. The present analysis shows that tumor height, diameter, and anterior as well as posterior critical structure dose–volume parameters may be used to predict NVG risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose–Volume Relationships Associated With Temporal Lobe Radiation Necrosis After Skull Base Proton Beam Therapy

Purpose: We evaluated patient and treatment parameters correlated with development of temporal lobe radiation necrosis. Methods and Materials: This was a retrospective analysis of a cohort of 66 patients treated for skull base chordoma, chondrosarcoma, adenoid cystic carcinoma, or sinonasal malignancies between 2005 and 2012, who had at least 6 months of clinical and radiographic follow-up. The median radiation dose was 75.6 Gy (relative biological effectiveness [RBE]). Analyzed factors included gender, age, hypertension, diabetes, smoking status, use of chemotherapy, and the absolute dose:volume data for both the right and left temporal lobes, considered separately. A generalized estimating equation (GEE) regression analysis evaluated potential predictors of radiation necrosis, and the median effective concentration (EC50) model estimated dose–volume parameters associated with radiation necrosis. Results: Median follow-up time was 31 months (range 6-96 months) and was 34 months in patients who were alive. The Kaplan-Meier estimate of overall survival at 3 years was 84.9%. The 3-year estimate of any grade temporal lobe radiation necrosis was 12.4%, and for grade 2 or higher radiation necrosis was 5.7%. On multivariate GEE, only dose–volume relationships were associated with the risk of radiation necrosis. In the EC50 model, all dose levels from 10 to 70 Gy (RBE) were highly correlated with radiation necrosis, with a 15% 3-year risk of any-grade temporal lobe radiation necrosis when the absolute volume of a temporal lobe receiving 60 Gy (RBE) (aV60) exceeded 5.5 cm{sup 3}, or aV70 > 1.7 cm{sup 3}. Conclusions: Dose–volume parameters are highly correlated with the risk of developing temporal lobe radiation necrosis. In this study the risk of radiation necrosis increased sharply when the temporal lobe aV60 exceeded 5.5 cm{sup 3} or aV70 > 1.7 cm{sup 3}. Treatment planning goals should include constraints on the volume of temporal lobes receiving higher dose. The EC50 model provides suggested dose–volume temporal lobe constraints for conventionally fractionated high-dose skull base radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Contralateral Esophagus-Sparing Technique to Limit Severe Esophagitis Associated With Concurrent High-Dose Radiation and Chemotherapy in Patients With Thoracic Malignancies

Purpose: Severe (Radiation Therapy Oncology Group [RTOG] grade 3 or greater) esophagitis generally occurs in 15% to 25% of non–small cell lung cancer (NSCLC) patients undergoing concurrent chemotherapy and radiation therapy (CCRT), which may result in treatment breaks that compromise local tumor control and pose a barrier to dose escalation. Here, we report a novel contralateral esophagus-sparing technique (CEST) that uses intensity modulated radiation therapy (IMRT) to reduce the incidence of severe esophagitis. Methods and Materials: We reviewed consecutive patients with thoracic malignancies undergoing curative CCRT in whom CEST was used. The esophageal wall contralateral (CE) to the tumor was contoured as an avoidance structure, and IMRT was used to guide a rapid dose falloff gradient beyond the target volume in close proximity to the esophagus. Esophagitis was recorded based on the RTOG acute toxicity grading system. Results: We identified 20 consecutive patients treated with CCRT of at least 63 Gy in whom there was gross tumor within 1 cm of the esophagus. The median radiation dose was 70.2 Gy (range, 63-72.15 Gy). In all patients, ≥99% of the planning and internal target volumes was covered by ≥90% and 100% of prescription dose, respectively. Strikingly, no patient experienced grade ≥3 esophagitis (95% confidence limits, 0%-16%) despite the high total doses delivered. The median maximum dose, V45, and V55 of the CE were 60.7 Gy, 2.1 cc, and 0.4 cc, respectively, indicating effective esophagus cross-section sparing by CEST. Conclusion: We report a simple yet effective method to avoid exposing the entire esophagus cross-section to high doses. By using proposed CE dose constraints of V45 <2.5 cc and V55 <0.5 cc, CEST may improve the esophagus toxicity profile in thoracic cancer patients receiving CCRT even at doses above the standard 60- to 63-Gy levels. Prospective testing of CEST is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Evaluation of Normal Tissue Doses for Patients Receiving Radiation Therapy for Hodgkin Lymphoma on the Childhood Cancer Survivor Study and Recent Children's Oncology Group Trials

Purpose: Survivors of pediatric Hodgkin lymphoma (HL) are recognized to have an increased risk of delayed adverse health outcomes related to radiation therapy (RT). However, the necessary latency required to observe these late effects means that the estimated risks apply to outdated treatments. We sought to compare the normal tissue dose received by children treated for HL and enrolled in the Childhood Cancer Survivor Study (CCSS) (diagnosed 1970-1986) with that of patients treated in recent Children's Oncology Group (COG) trials (enrolled 2002-2012). Methods and Materials: RT planning data were obtained for 50 HL survivors randomly sampled from the CCSS cohort and applied to computed tomography planning data sets to reconstruct the normal tissue dosimetry. For comparison, the normal tissue dosimetry data were obtained for all 191 patients with full computed tomography–based volumetric RT planning on COG protocols AHOD0031 and AHOD0831. Results: For early-stage patients, the mean female breast dose in the COG patients was on average 83.5% lower than that for CCSS patients, with an absolute reduction of 15.5 Gy. For advanced-stage patients, the mean breast dose was decreased on average by 70% (11.6 Gy average absolute dose reduction). The mean heart dose decreased on average by 22.9 Gy (68.6%) and 17.6 Gy (56.8%) for early- and advanced-stage patients, respectively. All dose comparisons for breast, heart, lung, and thyroid were significantly lower for patients in the COG trials than for the CCSS participants. Reductions in the prescribed dose were a major contributor to these dose reductions. Conclusions: These are the first data quantifying the significant reduction in the normal tissue dose using actual, rather than hypothetical, treatment plans for children with HL. These findings provide useful information when counseling families regarding the risks of contemporary RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Dose Distribution in Carbon Ion Radiation Therapy for Stage I Lung Cancer

Purpose: To evaluate robustness of dose distribution of carbon-ion radiation therapy (C-ion RT) in non-small cell lung cancer (NSCLC) and to identify factors affecting the dose distribution by simulated dose distribution. Methods and Materials: Eighty irradiation fields for delivery of C-ion RT were analyzed in 20 patients with stage I NSCLC. Computed tomography images were obtained twice before treatment initiation. Simulated dose distribution was reconstructed on computed tomography for confirmation under the same settings as actual treatment with respiratory gating and bony structure matching. Dose-volume histogram parameters, such as %D95 (percentage of D95 relative to the prescribed dose), were calculated. Patients with any field for which the %D95 of gross tumor volume (GTV) was below 90% were classified as unacceptable for treatment, and the optimal target margin for such cases was examined. Results: Five patients with a total of 8 fields (10% of total number of fields analyzed) were classified as unacceptable according to %D95 of GTV, although most patients showed no remarkable change in the dose-volume histogram parameters. Receiver operating characteristic curve analysis showed that tumor displacement and change in water-equivalent pathlength were significant predictive factors of unacceptable cases (P<.001 and P=.002, respectively). The main cause of degradation of the dose distribution was tumor displacement in 7 of the 8 unacceptable fields. A 6-mm planning target volume margin ensured a GTV %D95 of >90%, except in 1 extremely unacceptable field. Conclusions: According to this simulation analysis of C-ion RT for stage I NSCLC, a few fields were reported as unacceptable and required resetting of body position and reconfirmation. In addition, tumor displacement and change in water-equivalent pathlength (bone shift and/or chest wall thickness) were identified as factors influencing the robustness of dose distribution. Such uncertainties should be regarded in planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Radiation Therapy–Related Gastrointestinal Toxicity From Anal Cancer Dose-Painted Intensity Modulated Radiation Therapy: Secondary Analysis of NRG Oncology RTOG 0529

Purpose: NRG Oncology RTOG 0529 assessed the feasibility of dose-painted intensity modulated radiation therapy (DP-IMRT) to reduce the acute morbidity of chemoradiation with 5-fluorouracil (5FU) and mitomycin-C (MMC) for T2-4N0-3M0 anal cancer. This secondary analysis was performed to identify patient and treatment factors associated with acute and late gastrointestinal (GI) adverse events (AEs). Methods and Materials: NRG Oncology RTOG 0529 treatment plans were reviewed to extract dose-volume data for tightly contoured small bowel, loosely contoured anterior pelvic contents (APC), and uninvolved colon outside the target volume (UC). Univariate logistic regression was performed to evaluate association between volumes of each structure receiving doses ≥5 to 60 Gy (V5-V60) in 5-Gy increments between patients with and without grade ≥2 acute and late GI AEs, and grade ≥3 acute GI AEs. Additional patient and treatment factors were evaluated in multivariate logistic regression (acute AEs) or Cox proportional hazards models (late AEs). Results: Among 52 evaluable patients, grade ≥2 acute, grade ≥2 late, and grade ≥3 acute GI AEs were observed in 35, 17, and 10 patients, respectively. Trends (P<.05) toward statistically significant associations were observed between grade ≥2 acute GI AEs and small bowel dose (V20-V40), grade ≥2 late GI AEs and APC dose (V60), grade ≥3 acute GI AEs and APC dose (V5-V25), increasing age, tumor size >4 cm, and worse Zubrod performance status. Small bowel volumes of 186.0 cc, 155.0 cc, 41.0 cc, and 30.4 cc receiving doses greater than 25, 30, 35, and 40 Gy, respectively, correlated with increased risk of acute grade ≥2 GI AEs. Conclusions: Acute and late GI AEs from 5FU/MMC chemoradiation using DP-IMRT correlate with radiation dose to the small bowel and APC. Such associations will be incorporated in the dose-volume normal tissue constraint design for future NRG oncology anal cancer studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Addition of a third field significantly increases dose to the brachial plexus for patients undergoing tangential whole-breast therapy after lumpectomy

Our goal was to evaluate brachial plexus (BP) dose with and without the use of supraclavicular (SCL) irradiation in patients undergoing breast-conserving therapy with whole-breast radiation therapy (RT) after lumpectomy. Using the standardized Radiation Therapy Oncology Group (RTOG)-endorsed guidelines delineation, we contoured the BP for 10 postlumpectomy breast cancer patients. The radiation dose to the whole breast was 50.4 Gy using tangential fields in 1.8-Gy fractions, followed by a conedown to the operative bed using electrons (10 Gy). The prescription dose to the SCL field was 50.4 Gy, delivered to 3-cm depth. The mean BP volume was 14.5 {+-} 1.5 cm{sup 3}. With tangential fields alone, the median mean dose to the BP was 0.57 Gy, the median maximum dose was 1.93 Gy, and the irradiated volume of the BP receiving 40, 45, and 50 Gy was 0%. When the third (SCL field) was added, the dose to the BP was significantly increased (P = .01): the median mean dose to the BP was 40.60 Gy, and the median maximum dose was 52.22 Gy. With 3-field RT, the median irradiated volume of the BP receiving 40, 45, and 50 Gy was 83.5%, 68.5%, and 24.6%, respectively. The addition of the SCL field significantly increases dose to the BP. The possibility of increasing the risk of BP morbidity should be considered in the context of clinical decision making.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reducing the low-dose lung radiation for central lung tumors by restricting the IMRT beams and arc arrangement

To compare the extent to which 7 different radiotherapy planning techniques for mediastinal lung targets reduces the lung volume receiving low doses of radiation. Thirteen non-small cell lung cancer patients with targets, including the mediastinal nodes, were identified. Treatment plans were generated to both 60- and 74-Gy prescription doses using 7 different planning techniques: conformal, hybrid conformal/intensity-modulated radiation treatment (IMRT), 7 equidistant IMRT beams, 2 restricted beam IMRT plans, a full (360 Degree-Sign ) modulated arc, and a restricted modulated arc plan. All plans were optimized to reduce total lung V5, V10, and V20 volumes, while meeting normal tissue and target coverage constraints. The mean values for the 13 patients are calculated for V5, V10, V20, V{sub ave}, V0-20, and mean lung dose (MLD) lung parameters. For the 74-Gy prescription dose, the mean lung V10 was 42.7, 43.6, 48.2, 56.6, 57, 55.8, and 54.1% for the restricted {+-}36 Degree-Sign IMRT, restricted modulated arc, restricted {+-}45 Degree-Sign IMRT, full modulated arc, hybrid conformal/IMRT, equidistant IMRT, and conformal plans, respectively. A similar lung sparing hierarchy was found for the 60-Gy prescription dose. For the treatment of central lung targets, the {+-}36 Degree-Sign restricted IMRT and restricted modulated arc planning techniques are superior in lowering the lung volume treated to low dose, as well as in minimizing MLD, followed by the {+-}45 Degree-Sign restricted IMRT plan. All planning techniques that allow the use of lateral or lateral/oblique beams result in spreading the low dose over a higher lung volume. The area under the lung dose-volume histogram curve below 20 Gy, V0-20, is proposed as an alternative to individual V{sub dose} parameters, both as a measure of lung sparing and as a parameter to be minimized during IMRT optimization.

61 RADIATION PROTECTION AND DOSIMETRY↗

Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dose and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simple shielding reduces dose to the contralateral breast during prone breast cancer radiotherapy

Our goal was to design a prone breast shield for the contralateral breast and study its efficacy in decreasing scatter radiation to the contralateral breast in a prone breast phantom setup receiving radiation therapy designed for breast cancer. We constructed a prone breast phantom setup consisting of (1) A thermoplastic mask with a left-sided depression created by a water balloon for a breast shape; (2) 2 plastic bags to hold water in the thermoplastic mask depression; (3) 2000 mL of water to fill the thermoplastic mask depression to create a water-based false breast; (4) 1-cm thick bolus placed in the contralateral breast holder; (5) 2 lead (Pb) sheets, each 0.1-cm thick for blocking scatter radiation in the contralateral bolus-based false breast; (6) a prone breast board to hold the thermoplastic mask, water, bolus, and lead; (7) 9 cm solid water on top of the breast board to simulate body; (8) a diode was used to verify dose for each treatment field of the treated water-based breast; (9) metal–oxide–semiconductor-field effect transistor (MOSFET) dosimeters to measure dose to the contralateral bolus-based breast. The phantom prone breast setup was CT simulated and treatment was designed with 95% isodose line covering the treated breast. The maximum dose was 107.1%. Megavoltage (MV) port images ensured accurate setup. Measurements were done using diodes on the treated water-based breast and MOSFET dosimeters at the medial and lateral sides of the contralateral bolus-based breast without and with the Pb shield. Five treatments were done for each of the 3 data sets and recorded individually for statistical purposes. All treatments were completed with 6 MV photons at 200 cGy per treatment. The dose contributions from each of the 3 data sets including 15 treatments total without and with the prone lead shield to the medial and lateral portions of contralateral bolus-based breast were averaged individually. Unshielded dose means were 37.11 and 2.94 cGy, and shielded dose means were 12.68 and 1.54 cGy, respectively. When comparing medial and lateral portions of the contralateral bolus-based doses without and with Pb, the shield significantly reduced dose to both sides of the contralateral breast (medial p = 2.64 × 10{sup −14}, lateral p = 4.91 × 10{sup −6}). The prone 0.2-cm Pb shield significantly reduced scatter dose to the contralateral breast on the order of 2 to 3 times. Reductions may be clinically relevant for women younger than 45 years by decreasing the risk of contralateral radiation-induced breast cancer in patients receiving radiation therapy for breast cancer. This shield is simple as it would be a part of the prone breast board during treatments, but future studies are warranted for safety and efficacy clinically.

61 RADIATION PROTECTION AND DOSIMETRY↗

'Omics analysis of low dose acetaminophen intake demonstrates novel response pathways in humans

Acetaminophen is the primary cause of acute liver toxicity in Europe/USA, which led the FDA to reconsider recommendations concerning safe acetaminophen dosage/use. Unfortunately, the current tests for liver toxicity are no ideal predictive markers for liver injury, i.e. they only measure acetaminophen exposure after profound liver toxicity has already occurred. Furthermore, these tests do not provide mechanistic information. Here, 'omics techniques (global analysis of metabolomic/gene-expression responses) may provide additional insight. To better understand acetaminophen-induced responses at low doses, we evaluated the effects of (sub-)therapeutic acetaminophen doses on metabolite formation and global gene-expression changes (including, for the first time, full-genome human miRNA expression changes) in blood/urine samples from healthy human volunteers. Many known and several new acetaminophen-metabolites were detected, in particular in relation to hepatotoxicity-linked, oxidative metabolism of acetaminophen. Transcriptomic changes indicated immune-modulating effects (2 g dose) and oxidative stress responses (4 g dose). For the first time, effects of acetaminophen on full-genome human miRNA expression have been considered and confirmed the findings on mRNA level. 'Omics techniques outperformed clinical chemistry tests and revealed novel response pathways to acetaminophen in humans. Although no definitive conclusion about potential immunotoxic effects of acetaminophen can be drawn from this study, there are clear indications that the immune system is triggered even after intake of low doses of acetaminophen. Also, oxidative stress-related gene responses, similar to those seen after high dose acetaminophen exposure, suggest the occurrence of possible pre-toxic effects of therapeutic acetaminophen doses. Possibly, these effects are related to dose-dependent increases in levels of hepatotoxicity-related metabolites. -- Highlights: ► 'Omics techniques outperformed classic clinical chemistry tests. ► Metabolomic analyses led to the detection of five new acetaminophen metabolites. ► Low dose APAP changed immune and oxidative stress related gene expression in blood. ► APAP-induced full-genome human blood miRNA profiles were assessed for the first time.

60 APPLIED LIFE SCIENCES↗

Comparing probabilistic and descriptive analyses of time–dose–toxicity relationship for determining no-observed-adverse-effect level in drug development

The no-observed-adverse-effect level (NOAEL) of a drug defined from animal studies is important for inferring a maximal safe dose in human. However, several issues are associated with its concept, determination and application. It is confined to the actual doses used in the study; becomes lower with increasing sample size or dose levels; and reflects the risk level seen in the experiment rather than what may be relevant for human. We explored a pharmacometric approach in an attempt to address these issues. We first used simulation to examine the behaviour of the NOAEL values as determined by current common practice; and then fitted the probability of toxicity as a function of treatment duration and dose to data collected from all applicable toxicology studies of a test compound. Our investigation was in the context of an irreversible toxicity that is detected at the end of the study. Simulations illustrated NOAEL's dependency on experimental factors such as dose and sample size, as well as the underlying uncertainty. Modelling the probability as a continuous function of treatment duration and dose simultaneously to data from multiple studies allowed the estimation of the dose, along with its confidence interval, for a maximal risk level that might be deemed as acceptable for human. The model-based data integration also reconciled between-study inconsistency and explicitly provided maximised estimation confidence. Such alternative NOAEL determination method should be explored for its more efficient data use, more quantifiable insight to toxic doses, and the potential for more relevant animal-to-human translation. - Highlights: • Simulations revealed issues with NOAEL concept, determination and application. • Probabilistic modelling was used to address these issues. • The model integrated time-dose-toxicity data from multiple studies. • The approach uses data efficiently and may allow more meaningful human translation.

60 APPLIED LIFE SCIENCES↗

Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i) substantial dose reduction, which is less pronounced in children compared to adult, (ii) higher dose reduction in scans following a lateral compared to scans following an anterior-posterior topogram acquisition, (iii) increase of image noise and degradation of SNR in the obtained images compared to the fixed milliamperes technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗