Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Beam Line Design and Beam Physics Study of Energy Recovery Linac Free Electron Laser at Peking University

Energy recovering linac (ERL) offers an attractive alternative for generating intense beams of charged particles by approaching the operational efficiency of a storage ring while maintaining the superior beam quality typical of a linear accelerator. In ERLs, the decelerated beam cancels the beam loading effects of the accelerated beam with high repetition rate. Therefore, ERLs can, in principle, accelerate very high average currents with only modest amounts of RF power. So the efficiency of RF power to beam is much higher. Furthermore, the energy of beam to dump is lower, so it will reduce dump radiation. With the successful experiments in large maximum-to-injection energy ratio up to 51:1 and high power FEL up to 14kW, the use of ERL, especially combining with superconducting RF technology, provides a potentially powerful new paradigm for generation of the charged particle beams used in MW FEL, synchrotron radiation sources, high-energy electron cooling devices and so on. The 3+1/2 DC-SC photo injector and two 9cell TESLA superconducting cavity for IR SASE FEL in PKU provides a good platform to achieve high average FEL with Energy Recovery. The work of this thesis is on Beam line design and Beam dynamics study of Energy Recovery Linac Free Electron Laser for Peking University. It is the upgrade of PKU facility, which is under construction. With ERL, this facility can work in CW mode, so it can operate high average beam current without RF power constraint in main linac and generate high average FEL power. Moreover, it provides a test facility to study the key technology in ERL. System parameters are optimized for PKU ERL-FEL. The oscillation FEL output power is studied with different bunch charge, transverse emittance, bunch length and energy spread. The theory of optimal RF power and Q{sub ext} with ERL and without ERL is analyzed and applied to PKU injector and linac including microphonic effect. pace charge effect in the injector and merger is studied for beam energy at ~5MeV. Simulation shows that in the 3+1/2 DC- C injector, there is a region the beam could be over focused by RF electromagnetic field and the transverse emittance in the transport line up to linac will increase instantly due to over focusing. In order to eliminate this effect on beam emittance, several solutions are investigated to avoid over focusing. This result is very important for beam loading experiment for low bunch charge operation. Meanwhile, different merger structures are compared in terms of error sensitivity and emittance increase with space charge effect. In recirculation beam line, a new symmetric 180{degree} arc structure is designed. It fulfills the achromatic condition and adjustable bunch compression. These two parameters are controlled by different Quads knob. With this novel structure, the recirculation lattice can achieve path length adjustment, bunch compression and decompression in a large range. With beamline error, the beam central orbit will deviate from the designed trajectory. An orbit correction system is optimized, which balances between cost and performance of orbit after correction at design level. Different methods are used to estimate its robustness. The BBU instability, especially multi-pass BBU imposed a potentially severe limitation to the average current that can be accelerated in an ERL. Simulation gives the harmful HOMs and predicts that the threshold average current in this machine is much higher than the possible operation current. This work is based on the existing facility in PKU, so it provides guidelines for the facility operation and upgrade in the future. The theoretical analysis of ERL requirement and FEL requirement on beam transport line and beam property paves the way for future ERL research.

43 PARTICLE ACCELERATORS↗

Electromagnetic Shower from Cosmic Muons in NOvA Detector

NO$\nu$A (NuMI Off-Axis $\nu_e$ Appearance) experiment is a neutrino $\nu_\mu \rightarrow \nu_e$ oscillation experiment with a baseline of 810 km. The signature for a $\nu_\mu \rightarrow \nu_e$ oscillation in the far detector is the production of an electromagnetic (EM) shower due to the charge current (CC) interaction of $\nu_e$ with the detector material. Cosmic muon induced electromagnetic showers can serve as a source of EM shower sample that can be used as a data-driven method for validating the EM shower modelling and EM shower identification algorithms at NO$\nu$A. The work reported in the thesis is the first ever implementation of cosmic muon induced EM shower for such a purpose in the NO$\nu$A experiment. We extracted EM shower sample from two sources - muon undergoing bremsstrahlung (Brem) and muon decay in flight to electron (DiF). Brem sample, extracted from cosmic muon, turns out to be a very useful data-driven method for testing EM shower modelling and the part icle identification (PID) algorithms for the detection of $\nu_e$-CC interactions. A new muon removal (MR) technique is developed and applied to remove the muon hits inside the bremsstrahlung shower. However, a complete removal of the muon energy in the event is not possible with high efficiency. DiF induced EM shower, on the other hand, is exactly similar to $\nu_e$-CC EM shower because DiF is a pure electron initiated EM shower. Therefore, DiF EM shower, once extracted, mimicks the shower of a $\nu_e$-CC interaction event. We present the extraction methods for both brem and DiF events in MC and cosmic data in far and near detector of NO$\nu$A and its use in data driven validation of $\nu_e$ EM shower modelling and $\nu_e$ signal selection efficiency across the detector. A systematic uncertainty is also assigned on $\nu_e$ appearance signal selection based on this study to take into account the difference in EM shower modelling in data and MC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of ion Coulomb crystals in a linear Paul trap

We describe a simple and fast method for simulating observed images of ion Coulomb crystals. In doing so, cold elastic collisions between Coulomb crystals and virtual very light atoms are implemented in a molecular dynamics (MD) simulation code. Such an approach reproduces the observed images of Coulomb crystals by obtaining density plots of the statistics of existence of each ion. The simple method has the advantage of short computing time in comparison with previous calculation methods. As a demonstration of the simulation, the formation of a planar Coulomb crystal with a small number of ions has been investigated in detail in a linear ion trap both experimentally and by simulation. However, also large Coulomb crystals including up to 1400 ions have been photographed and simulated to extract the secular temperature and the number of ions. For medium-sized crystals, a comparison between experiments and calculations has been performed. Moreover, an MD simulation of the sympathetic cooling of small molecular ions was performed in order to test the possibility of extracting the temperature and the number of refrigerated molecular ions from crystal images of laser-cooled ions. Such information is basic to studying ultracold ion-molecule reactions using ion Coulomb crystals including sympathetically cooled molecular ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Lensing of Fast Radio Bursts by Plasma Structures in Host Galaxies

The amplitudes of fast radio bursts (FRBs) can be strongly modulated by plasma lenses in their host galaxies, including that of the repeating FRB 121102 at ∼1 Gpc luminosity distance. Caustics require the lens’ dispersion measure depth (DM{sub ℓ}), scale size (a), and distance from the source (d{sub sl}) to satisfy DM{sub ℓ}d{sub sl}/a{sup 2}≳0.65 pc{sup 2} au{sup −2} cm{sup −3}. Caustics produce strong magnifications (≲10{sup 2}) on short timescales (≲ hours to days) that appear as narrow spectral peaks (0.1–1 GHz). They also suppress the flux density in longer-duration (∼months) troughs. Multiply imaged bursts will arrive differentially by <1 μs to tens of ms with different apparent dispersion measures, δDM∼1 pc cm{sup −3}. When differing by less than the burst width, interference effects in dynamic spectra will be seen. Larger arrival time perturbations may mask any underlying periodicity with period ≲1 s. Strong lensing requires sources smaller than (Fresnelscale){sup 2}/a, which includes compact objects such as neutron star magnetospheres but excludes active galactic nuclei. We discuss constraints on densities, magnetic fields, and locations of plasma lenses related to the conditions needed for lensing to occur. Much of the phenomenology of the repeating FRB source FRB 121102 can be accounted for in this picture, which can be tested by obtaining wideband spectra of bursts (from <1 to 10 GHz and possibly higher) that will also help characterize the plasma environment near FRB sources. A rich variety of phenomena is expected from an ensemble of lenses near an FRB source.

79 ASTRONOMY AND ASTROPHYSICS↗

X-Ray Emitting GHz-Peaked Spectrum Galaxies: Testing a Dynamical-Radiative Model with Broad-Band Spectra

In a dynamical-radiative model we recently developed to describe the physics of compact, GHz-Peaked-Spectrum (GPS) sources, the relativistic jets propagate across the inner, kpc-sized region of the host galaxy, while the electron population of the expanding lobes evolves and emits synchrotron and inverse-Compton (IC) radiation. Interstellar-medium gas clouds engulfed by the expanding lobes, and photoionized by the active nucleus, are responsible for the radio spectral turnover through free-free absorption (FFA) of the synchrotron photons. The model provides a description of the evolution of the GPS spectral energy distribution (SED) with the source expansion, predicting significant and complex high-energy emission, from the X-ray to the {gamma}-ray frequency domain. Here, we test this model with the broad-band SEDs of a sample of eleven X-ray emitting GPS galaxies with Compact-Symmetric-Object (CSO) morphology, and show that: (i) the shape of the radio continuum at frequencies lower than the spectral turnover is indeed well accounted for by the FFA mechanism; (ii) the observed X-ray spectra can be interpreted as non-thermal radiation produced via IC scattering of the local radiation fields off the lobe particles, providing a viable alternative to the thermal, accretion-disk dominated scenario. We also show that the relation between the hydrogen column densities derived from the X-ray (N{sub H}) and radio (N{sub HI}) data of the sources is suggestive of a positive correlation, which, if confirmed by future observations, would provide further support to our scenario of high-energy emitting lobes.

08 HYDROGEN↗

Black Holes in an Effective Field Theory Extension of General Relativity

Effective field theory methods suggest that some rather general extensions of general relativity include, or are mimicked by, certain higher-order curvature corrections, with coupling constants expected to be small but otherwise arbitrary. Thus, the tantalizing prospect to test the fundamental nature of gravity with gravitational-wave observations, in a systematic way, emerges naturally. Here, we build black hole solutions in such a framework and study their main properties. Once rotation is included, we find the first purely gravitational example of geometries without Z 2 symmetry. Despite the higher-order operators of the theory, we show that linearized fluctuations of such geometries obey second-order differential equations. We find nonzero tidal Love numbers. We study and compute the quasinormal modes of such geometries. These results are of interest to gravitational-wave science but also potentially relevant for electromagnetic observations of the galactic center or x-ray binaries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision spectroscopy of Kaonic helium-3 and helium-4 3d{yields}2p X-rays

Recently, the shift of the kaonic helium-4 2p state was precisely determined by the E570 and SIDDHARTA experiments. Prior to the experiment by E570, the average of three earlier experimental results showed -43{+-}8 eV,while most of the theoretical calculations give {approx}0 eV. This five-sigma discrepancy between theory and experiment was known as the 'kaonic helium puzzle'. A recent theoretical model showed a possible resonance-like shift of maximum 10 eV for a certain value of a deep antikaon-nucleon interaction potential, which is different in helium 3 and helium 4.The E570 experiment determined the shift of the kaonic helium-4 2p state as +2{+-}2 (stat){+-}2 (sys) eV in 2007. The SIDDHARTA experiment determined the shift as 0{+-}6(stat){+-}2(sys) eV in 2009. The results of these experiments resolved the long-standing puzzle. A new experiment of the kaonic helium-3 X-ray measurement is being prepared by the J-PARC E17 collaborators, and the kaonic helium-3 X-ray data taken very recently by the SIDDHARTA experiment are on the way to be analyzed. The results of the E570, E17 and SIDDHARTA experiments examine the strong interaction for light nuclei with different isospin, and test furthermore recent theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pseudospectral collocation methods for the computation of the self-force on a charged particle: Generic orbits around a Schwarzschild black hole

The inspiral of a stellar compact object into a massive black hole, an extreme-mass-ratio inspiral, is one of the main sources of gravitational waves for the future space-based Laser Interferometer Space Antenna. We expect to be able to detect and analyze many cycles of these slowly inspiraling systems, which makes them truly high-precision tools for gravitational-wave astronomy. To that end, the use of very precise theoretical waveform templates in the data analysis is required. To build them, we need to have a deep understanding of the gravitational backreaction mechanism responsible for the inspiral. The self-force approach describes the inspiral as the action of a local force that can be obtained from the regularization of the perturbations created by the stellar compact object on the massive black hole geometry. In this paper we extend a new time-domain technique for the computation of the self-force from the circular case to the case of eccentric orbits around a nonrotating black hole. The main idea behind our scheme is to use a multidomain framework in which the small compact object, described as a particle, is located at the interface between two subdomains. Then, the equations at each subdomain are homogeneous wave-type equations, without distributional sources. In this particle-without-particle formulation, the solution of the equations is smooth enough to provide good convergence properties for the numerical computations. This formulation is implemented by using a pseudospectral collocation method for the spatial discretization, combined with a Runge-Kutta algorithm for the time evolution. We present results from several simulations of eccentric orbits in the case of a scalar charged particle around a Schwarzschild black hole, an excellent test bed model for testing the techniques for self-force computations. In particular, we show the convergence of the method and its ability to resolve the field and its derivatives across the particle location. Finally, we provide numerical values of the self-force for different orbital parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

First Field Measurements of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1

Within the US Magnet Development Program (MDP) a 15 T Nb 3 Sn dipole was developed, to demonstrate a magnet design for a post-LHC pp Collider. Specifically, the magnet design is based on 60 mm aperture 4-layer shell-type coils, graded between the inner and outer layers to maximize the magnet performance. The cable in the two innermost layers has 28 strands 1.0 mm in diameter and the cable in the two outermost layers has 40 strands 0.7 mm in diameter. Both cables use RRP Nb3Sn wires produced by Bruker-OST. Magnet coils are surrounded by vertically-split thick iron laminations, con-nected by aluminum I-clamps, and a thick stainless-steel skin. The magnet was tested at the Vertical Magnet Test Facility (VMTF) at Fermilab. This paper reports the first results of magnetic measure-ments of the 15 T Nb 3 Sn dipole demonstrator including geometrical harmonics, coil magnetization and iron saturation effects. The ex-perimental data are compared with the magnetic calculations.

43 PARTICLE ACCELERATORS↗

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel technique applying spectral estimation to Johnson noise thermometry - 317

Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift free temperature measurements. The two techniques developed by Oak Ridge National Laboratory to remove transient and periodic EMI are briefly discussed in this paper. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying either technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: Oak Ridge National Laboratory, Sandia National Laboratory, and Tennessee Valley Authority (TVA) Kingston Steam Plant. Each of these locations enabled improvement on the EMI removal algorithm. The conclusions made from the results at each of these locations is discussed, as well as, possible future work. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Groenewold-Moyal Plane and its Quantum Physics

Quantum theories constructed on the noncommutative spacetime called the Groenewold-Moyal(GM) plane exhibit many interesting properties such as causality violation, Lorentz and CPT non-invariance and twisted statistics. Such violations lead to many striking features that may be tested experimentally. Thus these theories predict Pauli-forbidden transitions due to twisted statistics, anisotropies and acausal effects in the cosmic microwave background radiation in correlations of observables and Lorentz and CPT violations in scattering amplitudes. Such features of quantum physics on the GM plane are surveyed in this review.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple diagnostics in a high-pressure hydrogen microwave plasma torch

We present an experimental study of a hydrogen plasma produced by a microwave axial injection torch, launching the plasma in a helium-filled chamber. Three different diagnostic methods have been used to obtain the electron density and temperature as follows: The Stark intersection method of Balmer spectral lines (already tested in argon and helium plasmas); the modified Boltzmann-plot showing that the plasma is far from the local thermodynamic equilibrium but ruled by the excitation-saturation balance; and a study by the disturbed bilateral relations theory. All of these diagnostic techniques show a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermoluminescence (TL) Analysis and Fading Studies of Naturally Occurring Salt Irradiated by 500 mGy Gamma Rays

The aim of the present study was to investigate the potential of the naturally occurring salt for the dosimetry purposes, using TL. The fine powder samples (20 mg) were irradiated by {gamma}- rays from 500 mGy to 2500 mGy by using Theratron-780C Cobalt-60 source, however, this paper discusses about 500 mGy only. The TL glow curve peak parameters were studied by using Chen's peak shape equation. TL glow curves were compared with fitted curves using glow curve deconvolution (GCD) method by using Kitis expression. The kinetic parameter values (E, b and s) so calculated, are in good agreement with those available in literature. The calculated energy values were also verified by using various heating rate (VHR) method. {chi}{sup 2} test and figure of merit (FOM) calculation was done to accept the goodness of fit between the curves. Fading studies of the sample showed a good fitting between the curves. The analysis suggests that natural salt should be considered for dosimetry purposes.

36 MATERIALS SCIENCE↗

Laboratory reflectometer for the investigation of optical elements in a wavelength range of 5–50 nm: description and testing results

We describe a laboratory reflectometer developed at the IPM RAS for precision measurements of spectral and angular dependences of the reflection and transmission coefficients of optical elements in a wavelength range of 5–50 nm. The radiation is monochromatised using a high-resolution Czerny–Turner spectrometer with a plane diffraction grating and two spherical collimating mirrors. A toroidal mirror focuses the probe monochromatic beam on a sample. The X-ray source is a highly ionised plasma produced in the interaction of a high-power laser beam with a solid target at an intensity of 10{sup 11}–10{sup 12} W cm{sup –2}. To stabilise the emission characteristics, the target executes translatory and rotary motions in such a way that every pulse irradiates a new spot. The short-focus lens is protected from contamination by erosion products with the use of a specially designed electromagnetic system. The samples under study are mounted on a goniometer is accommodated in a dedicated chamber, which provides five degrees of freedom for samples up to 500 mm in diameter and two degrees of freedom for a detector. The sample mass may range up to 10 kg. The X-ray radiation is recorded with a detector composed of a CsI photocathode and two microchannel plates. A similar detector monitors the probe beam intensity. The spectral reflectometer resolution is equal to 0.030 nm with the use of ruled gratings with a density of 900 lines mm{sup –1} (spectral range: 5–20 nm) and to 0.067 nm for holographic gratings with a density of 400 lines mm{sup –1} (spectral range: 10–50 nm). We analyse the contribution of higher diffraction orders to the probe signal intensity and the ways of taking it into account in the measurements. Examples are given which serve to illustrate the reflectometer application to the study of multilayer mirrors and filters. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗