Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gaussian Processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Effect of Measurement vs. Counting Errors on Parameters' Covariance in Neutron Tomography Analysis

We present here a method that estimates the relative effect of the counting uncertainty and of the instrument uncertainty on that of the parameters in a parametric model for neutron time of flight. The final result, obtained independently of calculation of the parameter values from measured data, presents explicitly the ratio of the two uncertainties in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗

Parameters’ Covariance in Neutron Time of Flight Analysis – Explicit Formulae

We present here a method that estimates the parameters’ variance in a parametric model for neutron time of flight (NToF). The analytical formulae for parameter variances, obtained independently of calculation of parameter values from measured data, express the variances in terms of the choice, settings, and placement of the detector and the oscilloscope. Consequently, the method can serve as a tool in planning a measurement setup.

fusion↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

A Gaussian mixture model for definition of lung tumor volumes in positron emission tomography

The increased interest in {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in radiation treatment planning in the past five years necessitated the independent and accurate segmentation of gross tumor volume (GTV) from FDG-PET scans. In some studies the radiation oncologist contours the GTV based on a computed tomography scan, while incorporating pertinent data from the PET images. Alternatively, a simple threshold, typically 40% of the maximum intensity, has been employed to differentiate tumor from normal tissue, while other researchers have developed algorithms to aid the PET based GTV definition. None of these methods, however, results in reliable PET tumor segmentation that can be used for more sophisticated treatment plans. For this reason, we developed a Gaussian mixture model (GMM) based segmentation technique on selected PET tumor regions from non-small cell lung cancer patients. The purpose of this study was to investigate the feasibility of using a GMM-based tumor volume definition in a robust, reliable and reproducible way. A GMM relies on the idea that any distribution, in our case a distribution of image intensities, can be expressed as a mixture of Gaussian densities representing different classes. According to our implementation, each class belongs to one of three regions in the image; the background (B), the uncertain (U) and the target (T), and from these regions we can obtain the tumor volume. User interaction in the implementation is required, but is limited to the initialization of the model parameters and the selection of an 'analysis region' to which the modeling is restricted. The segmentation was developed on three and tested on another four clinical cases to ensure robustness against differences observed in the clinic. It also compared favorably with thresholding at 40% of the maximum intensity and a threshold determination function based on tumor to background image intensities proposed in a recent paper. The parts of the method that are user dependent were evaluated and resulted in initial estimates of the method's precision, which is in the order of {+-}10% of the average tumor volume estimate. With this work we have established the applicability of the GMM-based segmentation on clinical studies and we have made an initial assessment of the method's precision with respect to tumor volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classification of breast computed tomography data

Differences in breast tissue composition are important determinants in assessing risk, identifying disease in images and following changes over time. This paper presents an algorithm for tissue classification that separates breast tissue into its three primary constituents of skin, fat and glandular tissue. We have designed and built a dedicated breast CT scanner. Fifty-five normal volunteers and patients with mammographically identified breast lesions were scanned. Breast CT voxel data were filtered using a 5 pt median filter and the image histogram was computed. A two compartment Gaussian fit of histogram data was used to provide an initial estimate of tissue compartments. After histogram analysis, data were input to region-growing algorithms and classified as to belonging to skin, fat or gland based on their value and architectural features. Once tissues were classified, a more detailed analysis of glandular tissue patterns and a more quantitative analysis of breast composition was made. Algorithm performance assessment demonstrated very good or excellent agreement between algorithm and radiologist observers in 97.7% of the segmented data. We observed that even in dense breasts the fraction of glandular tissue seldom exceeded 50%. For most individuals the composition is better characterized as being a 70% (fat)-30% (gland) composition than a 50% (fat)-50% (gland) composition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Dose-volume histogram analysis in radiotherapy using the Gaussian error function

A mathematical model based on the Gaussian error and complementary error functions was proposed to describe the cumulative dose-volume histogram (cDVH) for a region of interest in a radiotherapy plan. Parameters in the model (a, b, c) are related to different characteristics of the shape of a cDVH curve such as the maximum relative volume, slope and position of a curve drop off, respectively. A prostate phantom model containing a prostate, the seminal vesicle, bladder and rectum with cylindrical organ geometries was used to demonstrate the effect of interfraction prostate motion on the cDVH based on this error function model. The prostate phantom model was planned using a five-beam intensity modulated radiotherapy (IMRT), and a four-field box (4FB), technique with the clinical target volume (CTV) shifted in different directions from the center. In the case of the CTV moving out of the planning target volume (PTV), that is, the margin between the CTV and PTV is underestimated, parameter c (related to position of curve drop off) in the 4FB plan and parameters b (related to the slope of curve) and c in the IMRT plan vary significantly with CTV displacement. This shows that variation of the cDVH is present in the 4FB plan and such variation is more serious in the IMRT plan. These variations of cDVHs for 4FB and IMRT are due to the different dose gradients at the CTV edges in the anterior and posterior directions for the 4FB and IMRT plan. It is believed that a mathematical representation of the dose-volume relationship provides another viewpoint from which to illustrate problems with radiotherapy delivery such as internal organ motion that affect the dose distribution in a treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the measured dose profile data and the fitted Gaussian functions. The solid-state detector had no energy dependence--within the energy range of interest--and the analytical model succeeded in reproducing the absolute dose values obtained with the pencil ion chamber. For the case of large cone-beam single axial scans, the quantity that better characterizes the total energy imparted to the patient is the weighted dose profile integral (DPI{sub w}). The DPI{sub w} can be easily determined from the two parameters that define the Gaussian functions: f(0) and {sigma}. The authors found that the DLP underestimated the total energy imparted to the patient by more than 20%. The authors also found that the calculated CT dosimetric quantities were higher than those displayed on the scanner console. Conclusions: The authors described and validated a method to assess radiation dose in large cone-beam single axial scans. This method offers a simple and more accurate estimation of the total energy imparted to the patient, thus offering the possibility to update the bridge between CT dosimetry and the estimation of the effective dose for cone-beam CT examinations in radiology, nuclear medicine, and radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system

Purpose: To present our method and experience in commissioning dose models in water for spot scanning proton therapy in a commercial treatment planning system (TPS). Methods: The input data required by the TPS included in-air transverse profiles and integral depth doses (IDDs). All input data were obtained from Monte Carlo (MC) simulations that had been validated by measurements. MC-generated IDDs were converted to units of Gy mm{sup 2}/MU using the measured IDDs at a depth of 2 cm employing the largest commercially available parallel-plate ionization chamber. The sensitive area of the chamber was insufficient to fully encompass the entire lateral dose deposited at depth by a pencil beam (spot). To correct for the detector size, correction factors as a function of proton energy were defined and determined using MC. The fluence of individual spots was initially modeled as a single Gaussian (SG) function and later as a double Gaussian (DG) function. The DG fluence model was introduced to account for the spot fluence due to contributions of large angle scattering from the devices within the scanning nozzle, especially from the spot profile monitor. To validate the DG fluence model, we compared calculations and measurements, including doses at the center of spread out Bragg peaks (SOBPs) as a function of nominal field size, range, and SOBP width, lateral dose profiles, and depth doses for different widths of SOBP. Dose models were validated extensively with patient treatment field-specific measurements. Results: We demonstrated that the DG fluence model is necessary for predicting the field size dependence of dose distributions. With this model, the calculated doses at the center of SOBPs as a function of nominal field size, range, and SOBP width, lateral dose profiles and depth doses for rectangular target volumes agreed well with respective measured values. With the DG fluence model for our scanning proton beam line, we successfully treated more than 500 patients from March 2010 through June 2012 with acceptable agreement between TPS calculated and measured dose distributions. However, the current dose model still has limitations in predicting field size dependence of doses at some intermediate depths of proton beams with high energies. Conclusions: We have commissioned a DG fluence model for clinical use. It is demonstrated that the DG fluence model is significantly more accurate than the SG fluence model. However, some deficiencies in modeling the low-dose envelope in the current dose algorithm still exist. Further improvements to the current dose algorithm are needed. The method presented here should be useful for commissioning pencil beam dose algorithms in new versions of TPS in the future.

60 APPLIED LIFE SCIENCES↗

Three independent one-dimensional margins for single-fraction frameless stereotactic radiosurgery brain cases using CBCT

Purpose: Setting a proper margin is crucial for not only delivering the required radiation dose to a target volume, but also reducing the unnecessary radiation to the adjacent organs at risk. This study investigated the independent one-dimensional symmetric and asymmetric margins between the clinical target volume (CTV) and the planning target volume (PTV) for linac-based single-fraction frameless stereotactic radiosurgery (SRS).Methods: The authors assumed a Dirac delta function for the systematic error of a specific machine and a Gaussian function for the residual setup errors. Margin formulas were then derived in details to arrive at a suitable CTV-to-PTV margin for single-fraction frameless SRS. Such a margin ensured that the CTV would receive the prescribed dose in 95% of the patients. To validate our margin formalism, the authors retrospectively analyzed nine patients who were previously treated with noncoplanar conformal beams. Cone-beam computed tomography (CBCT) was used in the patient setup. The isocenter shifts between the CBCT and linac were measured for a Varian Trilogy linear accelerator for three months. For each plan, the authors shifted the isocenter of the plan in each direction by ±3 mm simultaneously to simulate the worst setup scenario. Subsequently, the asymptotic behavior of the CTV V{sub 80%} for each patient was studied as the setup error approached the CTV-PTV margin.Results: The authors found that the proper margin for single-fraction frameless SRS cases with brain cancer was about 3 mm for the machine investigated in this study. The isocenter shifts between the CBCT and the linac remained almost constant over a period of three months for this specific machine. This confirmed our assumption that the machine systematic error distribution could be approximated as a delta function. This definition is especially relevant to a single-fraction treatment. The prescribed dose coverage for all the patients investigated was 96.1%± 5.5% with an extreme 3-mm setup error in all three directions simultaneously. It was found that the effect of the setup error on dose coverage was tumor location dependent. It mostly affected the tumors located in the posterior part of the brain, resulting in a minimum coverage of approximately 72%. This was entirely due to the unique geometry of the posterior head.Conclusions: Margin expansion formulas were derived for single-fraction frameless SRS such that the CTV would receive the prescribed dose in 95% of the patients treated for brain cancer. The margins defined in this study are machine-specific and account for nonzero mean systematic error. The margin for single-fraction SRS for a group of machines was also derived in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Theoretical Framework for Calibration in Computer Models: Parametrization, Estimation and Convergence Properties

Calibration parameters in deterministic computer experiments are those attributes that cannot be measured or available in physical experiments. Here, an approach to estimate them by using data from physical experiments and computer simulations. A theoretical framework is given which allows us to study the issues of parameter identifiability and estimation. We define the L 2 -consistency for calibration as a justification for calibration methods. It is shown that a simplified version of the original KO method leads to asymptotically L 2 -inconsistent calibration. This L 2 -inconsistency can be remedied by modifying the original estimation procedure. A novel calibration method, called the L 2 calibration, is proposed and proven to be L 2 -consistent and enjoys optimal convergence rate. Furthermore a numerical example and some mathematical analysis are used to illustrate the source of the L 2 -inconsistency problem.

97 MATHEMATICS AND COMPUTING↗

Orbit-product representation and correction of Gaussian belief propagation

We present a new interpretation of Gaussian belief propagation (GaBP) based on the 'zeta function' representation of the determinant as a product over orbits of a graph. We show that GaBP captures back-tracking orbits of the graph and consider how to correct this estimate by accounting for non-backtracking orbits. We show that the product over non-backtracking orbits may be interpreted as the determinant of the non-backtracking adjacency matrix of the graph with edge weights based on the solution of GaBP. An efficient method is proposed to compute a truncated correction factor including all non-backtracking orbits up to a specified length.

99 GENERAL AND MISCELLANEOUS↗

2018 fourth quarter report to NA-22 on Particle Classifier

This was the final quarter of the third and final year of this project. The team prepared and submitted this project’s final report to NA-22. Work during this quarter included responding to reviewer requests for the unsupervised statistical model paper for the American Statistical Association journal, and completing and submitting the paper about the semi-supervised statistical model to NIMA. We received the report from our North Carolina State University collaborators from the NA-22-sponsored CNEC Consortium, Professor Wilson and student Allen. The report describes their investigation of Dirichlet Process (DP) Gaussian Mixture Models based on pulse shape data from this project. The report is an appendix to this project’s final report, and may be converted into a journal paper in the coming year. Work was performed on the user interface to the Struck firmware. The project team submitted a draft workplan to NA-22 regarding additional work to diffuse improved PSD methods through the NA-22 fast neutron detection community.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

REBOUND: Reverse Engineering Bidirectional Outflow Under Non-Equilibrium Diffusion

Rare-earth elements (REEs) are essential for electronics, renewable energy, and defense technologies. However, the current supply of REEs relies on mining concentrated in a few countries and energy-intensive separations. DOE’s Basic Energy Sciences (BES) program has launched a grand challenge which aims to ensure a sustainable supply of critical REEs by developing innovative and environmentally friendly separation methods. As an alternative to costly and harmful traditional methods, the Non-Equilibrium Transport Driven Separations (NETS) initiative has created a microfluidic Y-channel co-flow method that applies external fields to exploit magneto- and electrohydrodynamic effects for separating dilute REE ions from complex feedstocks. Computational fluid dynamics (CFD) studies have identified a few operating conditions with promising ion selectivity and separation efficiency. However, challenges remain regarding Y-channel versatility across feedstocks and accurate incorporation of physical phenomena into CFD models. In this work, we develop a multi-fidelity modelling approach which integrates experimental results with CFD simulation to build a surrogate model for the dependence of separation efficiency to variation of design parameters. The surrogate model enables a reinforcement learning (RL) method to adaptively launch CFD and experimental runs, improving model fidelity around optimal Y-channel parameters.

36 MATERIALS SCIENCE↗

EcoBOT: an AI/ML enabled automated phenotyping capability for model plants

Introduction: Advances in automation and AI/ML offer new opportunities for plant science, including design, modeling, and analysis. This study aimed to develop an automated platform for researching small model plants under axenic conditions and integrate it with AI/ML tools. Methods: The EcoBOT platform was developed, which consists of sterile containers (EcoFABs) for growing plants and imaging for monitoring plant growth and health. Brachypodium distachyon was grown on the EcoBOT, and its response to nutrient limitation and copper stress was evaluated. Results: The results showed that Brachypodium distachyon grown in the EcoBOT maintained sterility and responded to nutrient limitation and copper stress. Analysis of over 6,500 root and shoot images revealed varying sensitivity and response rates to copper. Bayesian Optimization was used to improve model accuracies relating copper concentrations to plant biomass via sequential experiments, resulting in a >30% improvement. Discussion: The findings of this study demonstrate the potential of the EcoBOT platform for researching plant responses to environmental factors. Future experiments could focus on relating other chemical stresses and microbial interactions to create generalized models of plant responses.

AI image analysis↗

Statistical emulation of a perturbed basal melt ensemble of an ice sheet model to better quantify Antarctic sea level rise uncertainties

Abstract. Antarctic ice shelves are vulnerable to warming ocean temperatures, and some have already begun thinning in response to increased basal melt rates. Sea level is therefore expected to rise due to Antarctic contributions, but uncertainties in its amount and timing remain largely unquantified. In particular, there is substantial uncertainty in future basal melt rates arising from multi-model differences in thermal forcing and how melt rates depend on that thermal forcing. To facilitate uncertainty quantification in sea level rise projections, we build, validate, and demonstrate projections from a computationally efficient statistical emulator of a high-resolution (4 km) Antarctic ice sheet model, the Community Ice Sheet Model version 2.1. The emulator is trained to a large (500-member) ensemble of 200-year-long 4 km resolution transient ice sheet simulations, whereby regional basal melt rates are perturbed by idealized (yet physically informed) trajectories. The main advantage of our emulation approach is that by sampling a wide range of possible basal melt trajectories, the emulator can be used to (1) produce probabilistic sea level rise projections over much larger Monte Carlo ensembles than are possible by direct numerical simulation alone, thereby providing better statistical characterization of uncertainties, and (2) predict the simulated ice sheet response under differing assumptions about basal melt characteristics as new oceanographic studies are published, without having to run additional numerical ice sheet simulations. As a proof of concept, we propagate uncertainties about future basal melt rate trajectories, derived from regional ocean models, to generate probabilistic sea level rise estimates for 100 and 200 years into the future.

97 MATHEMATICS AND COMPUTING↗