Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

DQ Admittance Extraction for Inverter-Based Resources: Preprint

The power grid industry is pushing for electro-magnetic transient (EMT)-based studies for generation interconnection and planning process due to high penetrations of inverter-based resource (IBRs). Vendor-specific and site-specific black-box IBR models are preferred in those simulation studies. For small-signal analysis, measurement-based admittance models are necessary. In this paper, we demonstrate the extraction of frequency-domain dq frame IBR models. These linear models are specific to operating conditions. We demonstrate two extraction methods: frequency scan and a step response-based method. The latter relies on converting time-domain responses to Laplace-domain expressions via eigensystem realization analysis (ERA). Both can lead to dq admittance representation and the latter is time saving.

admittance model↗

Energy and water in the Western and Texas interconnects.

The Department of Energy's Office of Electricity has initiated a $60M program to assist the electric industry in interconnection-level analysis and planning. The objective of this effort is to facilitate the development or strengthening of capabilities in each of the three interconnections serving the lower 48 states of the United States, to prepare analyses of transmission requirements under a broad range of alternative futures and develop long-term interconnection-wide transmission expansion plans. The interconnections are the Western Interconnection, the Eastern Interconnection, and the Texas Interconnection. One element of this program address the support and development of an integrated energy-water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning (the Eastern Interconnection is not participating in this element). Specific objectives include: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between members of this proposal team and the Western Electricity Coordinating Council (WECC), Western Governors Association (WGA), the Electric Reliability Council of Texas (ERCOT) and their associated stakeholder teams. (3) Exercise the Energy-Water DSS to investigate water stress implications of the transmission planning scenarios put forward by WECC, WGA, and ERCOT. The goals of this project are: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between Western Electricity Coordinating Council, Electric Reliability Council of Texas, Western Governors Association, and Western States Water Council. (3) Exercise the Energy-Water DSS to investigate water transmission planning scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Quasi-Static Mooring System Modeling with Analytic Jacobians

This paper presents a generalized and efficient method for quasi-static analysis of mooring systems, including complex scenarios such as when shared mooring lines interconnect multiple floating wind or wave energy devices. While quasi-static mooring models are well established, most published formulations are focused on specific applications, and no publicly available implementations provide efficient handling of large mooring system networks. The present formulation addresses these gaps by: (1) formulating solutions for edge cases not typically supported by quasi-static models; (2) creating a fully generalized model structure such that any combination of mooring lines, point masses, and floating bodies can be assembled; and (3) deriving analytic expressions for the system Jacobians (stiffness matrices) so that systems with many degrees of freedom can be solved efficiently. These techniques form the theory basis of MoorPy, an open-source mooring analysis library. The model is demonstrated on nine scenarios of increasing complexity with features of interest for offshore renewable energy applications. When compared with steady-state results from a lumped-mass dynamic model, the results show that the quasi-static formulation accurately calculates profiles and tensions and that its analytic approach provides more efficient and reliable computation of system stiffness matrices than finite-differencing methods. These results verify the accuracy of the MoorPy model.

16 TIDAL AND WAVE POWER↗

Smart buildings with electric vehicle interconnection as buffer for local renewables?

Some conclusions from this presentation are: (1) EV Charging/discharging pattern mainly depends on the objective of the building (cost versus CO{sub 2}); (2) performed optimization runs show that stationary batteries are more attractive than mobile storage when putting more focus on CO{sub 2} emissions because stationary storage is available 24 hours a day for energy management - it's more effective; (3) stationary storage will be charged by PV, mobile only marginally; and (4) results will depend on the considered region and tariff. Final research work will show the results for 138 different buildings in nine different climate zones and three major utility service territories.

25 ENERGY STORAGE↗

Risk-averse optimization for resilience enhancement of complex engineering systems under uncertainties

With the growth of complexity and extent, large scale interconnected network systems, e.g., transportation networks or infrastructure networks, become more vulnerable to external disturbances. Hence, managing potential disruptive events during the design, operating, and recovery phase of an engineered system and therefore improving the system’s resilience is an important yet challenging task. Here, to ensure system resilience after the occurrence of failure events, this study proposes a mixed-integer linear programming (MILP) based restoration framework using heterogeneous dispatchable agents. The scenario-based stochastic optimization (SO) technique is adopted to deal with the inherent uncertainties imposed on the recovery process from nature. Moreover, different from conventional SO using deterministic equivalent formulations, the CVaR risk measure is implemented for this study because of the temporal sparsity of the decision making in applications such as the recovery from extreme events. The resulting restoration framework involves a large-scale MILP problem and thus an adequate decomposition technique i.e. modified Lagrangian dual decomposition, is also employed to achieve tractable computational complexity. Case study results based on the IEEE 37-bus test feeder demonstrate the benefits of using the proposed framework for resilience improvement as well as the advantages of adopting SO formulations.

42 ENGINEERING↗

Technoeconomic assessment of hydrogen cogeneration via high temperature steam electrolysis with a light-water reactor

Increased electricity production from renewable energy resources, coupled with low natural gas (NG) prices, has caused existing light-water reactors (LWRs) to experience diminishing returns from the electricity market. This reduction in revenue is forcing LWRs to consider alternative revenue streams, such as introduction hydrogen production or desalination, to remain profitable. This paper performs a technoeconomic assessment (TEA) regarding the viability of retrofitting existing pressurized-water reactors (PWRs) to produce green hydrogen (H 2 ) via high-temperature steam electrolysis (HTSE). Such an integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long term and eliminate CO 2 emissions from the hydrogen production process. Here, to accommodate such an integration, a detailed single market levelized cost of hydrogen (LCOH) and multimarket analyses were conducted of HTSE process operation, requirements, costing, and flexibility. Alongside this costing analysis, market analyses were conducted on the electric and hydrogen markets in the PJM interconnect. Utilizing a novel stochastic, dispatch optimization approach results suggest that a positive gain is achievable, and by operating in multiple markets, the nuclear facility can avoid the sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted is a differential cash flow analysis and, as such, does not present profit levels. LCOH analysis results demonstrate the potential exists to produce hydrogen at a cost as low as $1.20/kg. This price is lower than traditional steam methane reforming (SMR) allowing nuclear based hydrogen production to disrupt the existing hydrogen production market.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atomic layer deposited nanocrystalline tungsten carbides thin films as a metal gate and diffusion barrier for Cu metallization

Tungsten carbides (WC{sub x}) thin films were deposited on thermally grown SiO{sub 2} substrates by atomic layer deposition (ALD) using a fluorine- and nitrogen-free W metallorganic precursor, tungsten tris(3-hexyne) carbonyl [W(CO)(CH{sub 3}CH{sub 2}C ≡ CCH{sub 2}CH{sub 3}){sub 3}], and N{sub 2} + H{sub 2} plasma as the reactant at deposition temperatures between 150 and 350 °C. The present ALD-WC{sub x} system showed an ALD temperature window between 200 and 250 °C, where the growth rate was independent of the deposition temperature. Typical ALD characteristics, such as self-limited film growth and a linear dependency of the film grown on the number of ALD cycles, were observed, with a growth rate of 0.052 nm/cycle at a deposition temperature of 250 °C. The ALD-WC{sub x} films formed a nanocrystalline structure with grains, ∼2 nm in size, which consisted of hexagonal W{sub 2}C, WC, and nonstoichiometric cubic β-WC{sub 1−x} phase. Under typical deposition conditions at 250 °C, an ALD-WC{sub x} film with a resistivity of ∼510 μΩ cm was deposited and the resistivity of the ALD-WC{sub x} film could be reduced even further to ∼285 μΩ cm by further optimizing the reactant pulsing conditions, such as the plasma power. The step coverage of ALD-WC{sub x} film was ∼80% on very small sized and dual trenched structures (bottom width of 15 nm and aspect ratio of ∼6.3). From ultraviolet photoelectron spectroscopy, the work function of the ALD-WC{sub x} film was determined to be 4.63 eV. Finally, the ultrathin (∼5 nm) ALD-WC{sub x} film blocked the diffusion of Cu, even up to 600 °C, which makes it a promising a diffusion barrier material for Cu interconnects.

36 MATERIALS SCIENCE↗

Policy and Cost Allocation Considerations for Large Electric Load Interconnections: Emerging Policy Trends in Rate Structures, Interconnection, and Cost Impacts on Other System Users

Load growth in the United States is rapidly increasing: load from data centers alone has tripled over the past decade, and this growth is forecasted to continue accelerating. These and other large electric loads (LELs) promise economic benefits at the state and local level, but their deployment has also led to increasing concerns about grid impacts and potential cost shifts onto other ratepayers. Legislators, regulators, and other stakeholders are increasingly proposing and enacting policies in effort to balance these and other considerations. This white paper reviews state-level legislation, selected utility rate cases, and relevant federal orders in an effort to describe and categorize relevant trends in policies related to LEL cost allocation, interconnection, and deployment. Policy categories identified through this review include tax incentives, rate actions, and requirements related to interconnection, permitting, and reporting. By offering a taxonomy of policies, this white paper aims to offer a resource to policymakers and other stakeholders navigating this transformative moment for the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Joint Cyber/Safety Risk in Nuclear Power Systems

This report presents an analysis of the Emergency Core Cooling System (ECCS) for a generic Boiling Water Reactor (BWR)-4 NPP. The Electric Power Research Institute (EPRI) developed Hazards and Consequences Analysis for Digital Systems (HAZCADS) process is applied to the ECCS and its subsystems to identify unsafe control actions (UCAs) which act as possible cyber events of concern. The analysis is performed for two design basis events: Small-break Loss of Coolant Accident (SLOCA) and general transients (TRANS), such as unintended reactor trip. In previous work, HAZCADS UCAs were combined with other cyber-attack analysis to develop a risk-informed approach; however, this was for a single system. This report explores advanced systems engineering modeling approaches to model the interactions between digital assets across multiple systems which may be targeted by cyber adversaries. The complex and interdependent design of digital systems has the potential to introduce emergent cyber properties that are generally not covered by hazard analyses nor formal nuclear Probabilistic Risk Assessment (PRA). The R&D and supporting analysis presented here explores approaches to predict and manage how interdependent system properties effect risk. To show the potential impact of a successful cyber-attack to formal PRA event tree probabilities, HAZCADS analysis was also used. HAZCADS was also used to model the automatic depressurization system (ADS) automatic actuation. This analysis extended to an integrated system analysis for common-cause failure (CCF). In this aspect, the HAZCADS analysis continued by analyzing plant design details for system connectivity in support of critical plant functions. A dependency matrix was developed to depict the integrated functionality of the interconnected systems. Areas of potential CCF are indicated. Future work could include adversary attack development to show how CCF could be caused, resulting in PRA events. Across the multiple systems that comprise the ECCS, the analysis shows that the change in such probabilities was very different between systems. This indicates that some systems have a larger potential risk impact from successful cyber-attack or digital failure, which indicates a need for these systems to have a higher priority for design and defensive measures. Furthermore, we were able to establish that a risk analysis using any arbitrary threat model establishes an ordering of components with regard to cyber-risk. This ordering can be used to influence the overall system design with an eye to lowering risk, or as a way to understand real-time risk to operational systems based on a current threat landscape. Expert knowledge of both the analysis process and the system being analyzed is required to perform a HAZCADS analysis. The need for a tiered risk analysis is demonstrated by the results of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Alternative Approaches to Calculate Benefits of an Energy Imbalance Market With Wind and Solar Energy: Preprint

The anticipated increase in variable generation in the Western Interconnection over the next several years has raised concerns about how to maintain system balance, especially in smaller Balancing Authority Areas (BAAs). Given renewable portfolio standards in the West, it is possible that more than 50 gigawatts of wind capacity will be installed by 2020. Significant quantities of solar generationare likely to be added as well. The consequent increase in variability and uncertainty that must be managed by the conventional generation fleet and responsive loads has resulted in a proposal for an Energy Imbalance Market (EIM). This paper extends prior work to estimate the reserve requirements for regulation, spinning, and non-spinning reserves with and without the EIM. We also discussalternative approaches to allocating reserve requirements and show that some apparently attractive allocation methods have undesired consequences.

17 WIND ENERGY↗

Fast Determination of Distribution-Connected PV Impacts Using a Variable-Time-Step Quasi-Static Time-Series Approach

The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete ever more complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasistatic time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this type of complex analysis to enable efficient completion of PV impact studies. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the number of voltage regulator tap operations and highest and lowest voltage occurring on the distribution circuit during a 1-yr simulation period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91% reduction with less than 5% error when predicting voltage regulator operations. Furthermore, an alternate variable time-step method is also shown to perform adequately and shows promise of even greater reductions in simulation runtime.

14 SOLAR ENERGY↗

A Multi-Model Framework for Assessing Long- and Short-Term Climate Influences on the Electric Grid

Climate change influences many aspects of the electric grid, but prior work and industry practices often ignore the potential effects of changing climate, or they only consider a single effect or individual effects in isolation. Challenges vary with each grid and include adapting to long-term trends such as changing temperature and precipitation or shorter-term events such as drought or storms that could increase in frequency or intensity. Here we present a multi-model framework designed to analyze the effects of long and short-term climate impacts in combination. This framework couples capacity expansion and production cost models with hydrologic models and future climate scenario data to analyze alternative climate and energy futures at high spatial, temporal, and process resolutions. Furthermore, we constructed and evaluated the results of a suite of simulated scenarios exploring climate impacts on capacity investment and stress-tested the resulting future infrastructures using hourly dispatch modeling under alternative drought and load conditions. We demonstrate the approach through a case study of the U.S. Western Interconnection, where climate impacts depend on interactions between temperature-induced load, water availability for hydropower, technology competitiveness, and demand flexibility. Changes in 2038 generating capacity range from -8.5-16.6 GW, and changes in 2038 transmission capacity range from -1-2 GW. Capacity increases are driven by higher load from higher temperatures, while capacity reductions can be achieved in scenarios with higher future hydropower availability and increased demand flexibility. Scenarios requiring additional capacity cost an additional $\$5$-$\$17$ billion (discounted) from 2018 to 2038; however, scenarios with capacity reductions cost $\$1$-$\$18$ billion less. Stress tests on four 2038 infrastructures demonstrated that the identified systems were able to serve at least 99.999% of load and 99.96% of reserves. However, drought and unexpected high-load conditions can result in reduced capacity to respond to contingency events we did not model. Although these results are system and scenario specific, they highlight the importance of considering multiple climate change impacts simultaneously in long-term planning efforts and demonstrate a multi-model, multiscale approach that can be flexibly applied to any system and set of climate change concerns.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reactive Transport Models with Geomechanics to Mitigate Risks of CO2 Utilization and Storage

Reactivity of carbon dioxide (CO 2 ), rocks and brine is important in a number of practical situations in carbon dioxide sequestration. Injectivity of CO 2 will be affected by near wellbore dissolution or precipitation. Natural fractures or faults containing specific minerals may reactivate leading to induced seismicity. In this project, we first examined if the reactions between CO 2 , brine and rocks affect the nature of the porous medium and properties including petrophysical properties in the timeframe of the injection operations. This was done by carrying out experiments at sequestration conditions (2000 psi for corefloods and 2400 psi for batch experiments, and 600°C) with three different types of rocks – sandstone, limestone and dolomite. Experiments were performed in batch mode and corefloods were conducted over a two-week period. Batch experiments were performed with samples of differing surface area to understand the impact of surface area on overall reaction rates. Toughreact, a reactive transport model was used to interpret and understand the experimental results. The role of iron in dissolution and precipitation reactions was observed to be significant. Iron containing minerals – siderite and ankerite dissolved resulting in changes in porosity and permeability. Corefloods and batch experiments revealed similar patterns. With the right cationic balance, there is a possibility of precipitation of iron bearing carbonates. The results indicate that during injection operations mineralogical changes may lead to injectivity enhancements near the wellbore and petrophysical changes elsewhere in the system. Limestone and dolomite cores showed consistent dissolution at the entrance of the core. The dissolution led to formation of wormholes and interconnected dissolution zones. Results indicate that near wellbore dissolution in these rock-types may lead to rock failure. Micro-CT images of the cores before and after the experiments revealed that an initial high-permeability pathway facilitated the formation of wormholes. The peak cation concentrations and general trends were matched using Toughreact. Batch reactor modeling showed that the geometric factors obtained using powder data that related effective surface area to the BET surface area had to be reduced for fractured samples and cores. This indicates that the available surface area in consolidated samples is lower than that deduced from powder experiments. Field-scale modeling of reactive transport and geomechanics was developed in parallel at Idaho National Laboratory. The model is able to take into account complex chemistry, and consider interactions of natural fractures and faults. Poroelastic geomechanical considerations are also included in the model.

01 COAL, LIGNITE, AND PEAT↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Resonant planar antenna as an inductive plasma source

A resonant planar antenna as an inductive plasma source operating at 13.56 MHz inside a low pressure vacuum vessel is presented for potential plasma processing applications. Its principle consists in interconnecting elementary resonant meshes composed of inductive and capacitive elements. Due to its structure, the antenna shows a set of resonant modes associated with peaks of the real input impedance. Each of these modes is defined by its own current and voltage distribution oscillating at the frequency of the mode. A rectangular antenna of 0.55mx0.20m has been built, and first results obtained with argon plasmas are presented. Plasma generation is shown to be efficient as densities up to 4{center_dot}10{sup 17}m{sup -3} at 2000 W have been measured by microwave interferometry at a distance of 4 cm from the source plane. It is also demonstrated that the plasma couples inductively with the resonating currents flowing in the antenna above a threshold power of about 60 W. A non-uniformity of less than {+-}5% is obtained at 1000 W at a few centimeters above the antenna over 75% of its surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MoorDyn V2: New Capabilities in Mooring System Components and Load Cases

MoorDyn, an open-source mooring dynamics model, is being expanded with capabilities for additional mooring system features and load cases. As floating wind turbine technology matures, mooring systems are becoming more sophisticated and more complex scenarios need to be considered in the design process. Mooring systems may have synthetic line materials, ballast/buoyancy bodies along the lines, or interconnections between platforms. Failure modes may involve multiple cascading line failures that depend on mooring system dynamics. Features recently added to MoorDyn aim to address these emerging needs. MoorDyn’s linear elasticity model has been supplemented to support user-defined stress-strain curves, which can be adjusted to represent synthetic mooring materials. Rigid six-degree-of-freedom bodies in the mooring system can now be modeled using two new model objects. “Rod” objects provide an option for rigid cylindrical bodies. They use the existing Morison equation-based hydrodynamics model and can be connected to mooring lines at either end. “Body” objects provide a generic six-degree-of-freedom rigid-body representation based on a lumped-parameter model of translational and rotational properties. Rod objects can be added to Body objects and mooring lines can be attached at any location, allowing a wide variety of submerged structures to be integrated into the mooring system. Lastly, a means of dynamically simulating mooring line failures has been implemented. These new features, currently in the C++ version of MoorDyn, are described and then demonstrated on a two-turbine shared-mooring array. A qualitative view of the results suggests the new features are functioning as expected.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

MoorDyn V2: New Capabilities in Mooring System Components and Load Cases: Preprint

MoorDyn, an open-source mooring dynamics model, is being expanded with capabilities for additional mooring system features and load cases. As floating wind turbine technology matures, mooring systems are becoming more sophisticated and more complex scenarios need to be considered in the design process. Mooring systems may have synthetic line materials, ballast/buoyancy bodies along the lines, or interconnections between platforms. Failure modes may involve multiple cascading line failures that depend on mooring system dynamics. Features recently added to MoorDyn aim to address these emerging needs. MoorDyn’s linear elasticity model has been supplemented to support user-defined stress-strain curves, which can be adjusted to represent synthetic mooring materials. Rigid six-degree-of-freedom bodies in the mooring system can now be modeled using two new model objects. “Rod” objects provide an option for rigid cylindrical bodies. They use the existing Morison equation-based hydrodynamics model and can be connected to mooring lines at either end. “Body” objects provide a generic six-degree-of-freedom rigid-body representation based on a lumped-parameter model of translational and rotational properties. Rod objects can be added to Body objects and mooring lines can be attached at any location, allowing a wide variety of submerged structures to be integrated into the mooring system. Lastly, a means of dynamically simulating mooring line failures has been implemented. These new features, currently in the C++ version of MoorDyn, are described and then demonstrated on a two-turbine shared-mooring array. A qualitative view of the results suggests the new features are functioning as expected.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

A Unified Testing Platform to Mature Blockchain Applications for Grid Emulation Environments: Preprint

Blockchain technology is a relatively novel technology that can be used to develop more decentralized, autonomous and tamper-evident solutions. A feature that can aid Transactive Energy Systems to reach their goals by enabling individual actors to communicate and reach consensus with other participants in a more decentralized fashion. However, technical barriers to evaluate and adopt this type of technology within the electrical domain still exist. To facilitate this task, BLOSEM Unified Testing Platform (UTP), a DOE-sponsored, multi-lab effort intends to accelerate the development of solutions by offering a common set of reusable services that can be used to interconnect existent grid tools with blockchain services. UTP is intended to serve as development platform that can provide application engineers with the technical means to evaluate potential blockchain solutions, by enabling them to concentrate on the actual application functionalities while at the same time abstracting the connectivity and performance measurement tasks. The use of BLOSEM UTP is further demonstrated by implementing two potential use cases that are intended to validate both the feasibility of implementing these applications as blockchain-based solutions while also demonstrating the features provided by UTP.

blockchain↗