THE EXPANSION OF ACTIVE REGIONS INTO THE EXTENDED SOLAR CORONA

Advanced image processing of Large Angle and Spectrometric Coronagraph Experiment (LASCO) C2 observations reveals the expansion of the active region closed field into the extended corona. The nested closed-loop systems are large, with an apparent latitudinal extent of 50 Degree-Sign , and expanding to heights of at least 12 R{sub Sun }. The expansion speeds are {approx}10 km s{sup -1} in the AIA/SDO field of view, below {approx}20 km s{sup -1} at 2.3 R{sub Sun }, and accelerate linearly to {approx}60 km s{sup -1} at 5 R{sub Sun }. They appear with a frequency of one every {approx}3 hr over a time period of around three days. They are not coronal mass ejections (CMEs) since their gradual expansion is continuous and steady. They are also faint, with an upper limit of 3% of the brightness of background streamers. Extreme ultraviolet images reveal continuous birth and expansion of hot, bright loops from a new active region at the base of the system. The LASCO images show that the loops span a radial fan-like system of streamers, suggesting that they are not propagating within the main coronal streamer structure. The expanding loops brighten at low heights a few hours prior to a CME eruption, and the expansion process is temporarily halted as the closed field system is swept away. Closed magnetic structures from some active regions are not isolated from the extended corona and solar wind, but can expand to large heights in the form of quiescent expanding loops.

79 ASTRONOMY AND ASTROPHYSICS↗

TRIIG - Time-lapse reproduction of images through interactive graphics

Description of the hardware and software implementing the system of time-lapse reproduction of images through interactive graphics (TRIIG). The system produces a quality hard copy of processed images in a fast and inexpensive manner. This capability allows for optimal development of processing software through the rapid viewing of many image frames in an interactive mode. Three critical optical devices are used to reproduce an image: an Optronics photo reader/writer, the Adage Graphics Terminal, and Polaroid Type 57 high speed film. Typical sources of digitized images are observation satellites, such as ERTS or Mariner, computer coupled electron microscopes for high-magnification studies, or computer coupled X-ray devices for medical research.

Buckner, J. D.↗

Real-Time Feature Tracking Using Homography

This software finds feature point correspondences in sequences of images. It is designed for feature matching in aerial imagery. Feature matching is a fundamental step in a number of important image processing operations: calibrating the cameras in a camera array, stabilizing images in aerial movies, geo-registration of images, and generating high-fidelity surface maps from aerial movies. The method uses a Shi-Tomasi corner detector and normalized cross-correlation. This process is likely to result in the production of some mismatches. The feature set is cleaned up using the assumption that there is a large planar patch visible in both images. At high altitude, this assumption is often reasonable. A mathematical transformation, called an homography, is developed that allows us to predict the position in image 2 of any point on the plane in image 1. Any feature pair that is inconsistent with the homography is thrown out. The output of the process is a set of feature pairs, and the homography. The algorithms in this innovation are well known, but the new implementation improves the process in several ways. It runs in real-time at 2 Hz on 64-megapixel imagery. The new Shi-Tomasi corner detector tries to produce the requested number of features by automatically adjusting the minimum distance between found features. The homography-finding code now uses an implementation of the RANSAC algorithm that adjusts the number of iterations automatically to achieve a pre-set probability of missing a set of inliers. The new interface allows the caller to pass in a set of predetermined points in one of the images. This allows the ability to track the same set of points through multiple frames.

Clouse, Daniel S.↗

Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the Prostate

Purpose: Emerging prolonged, hypofractionated radiotherapy regimens rely on high-dose conformality to minimize toxicity and thus can benefit from image guidance systems that continuously monitor target position during beam delivery. To address this need we previously developed, as a potential add-on device for existing linear accelerators, a novel telerobotic ultrasound system capable of real-time, soft-tissue imaging. Expanding on this capability, the aim of this work was to develop and characterize an image-based technique for real-time detection of prostate displacements. Methods and Materials: Image processing techniques were implemented on spatially localized ultrasound images to generate two parameters representing prostate displacements in real time. In a phantom and five volunteers, soft-tissue targets were continuously imaged with a customized robotic manipulator while recording the two tissue displacement parameters (TDPs). Variations of the TDPs in the absence of tissue displacements were evaluated, as was the sensitivity of the TDPs to prostate translations and rotations. Robustness of the approach to probe force was also investigated. Results: With 95% confidence, the proposed method detected in vivo prostate displacements before they exceeded 2.3, 2.5, and 2.8 mm in anteroposterior, superoinferior, and mediolateral directions. Prostate pitch was detected before exceeding 4.7 Degree-Sign at 95% confidence. Total system time lag averaged 173 ms, mostly limited by ultrasound acquisition rate. False positives (FPs) (FP) in the absence of displacements did not exceed 1.5 FP events per 10 min of continuous in vivo imaging time. Conclusions: The feasibility of using telerobotic ultrasound for real-time, soft-tissue-based monitoring of target displacements was confirmed in vivo. Such monitoring has the potential to detect small clinically relevant intrafractional variations of the prostate position during beam delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal characterization of cerium monoxide in laser ablation plasmas using spectrally-resolved fast-gated imaging

The impact of oxidation chemistry on the emission characteristics and spatial structure of laser-produced Ce metal plasmas was investigated using laser-induced breakdown spectroscopy (LIBS) and time-resolved fast-gated imaging employing narrowband optical filters. Images of the plasma emission show that CeO coexists with atomic species in the periphery and vortex ring of the plasma plume. Image processing was also applied to combine independent monochromatic images of the plasma emission into a single merged image, culminating in a timelapse on the spatiotemporal evolution of atomic and molecular species within the plasma plume. The formation of CeO species was observed to proceed faster for plasmas generated in atmospheres containing larger concentrations of oxygen based on ratios of CeO-to-atomic emission intensities. Furthermore, these same ratios were shown to plateau and decrease at later times (≥25 μs), potentially indicating the depletion of CeO number densities in the plasma as the monoxide undergoes reactions to form higher polyatomic oxides. Altogether, these results provide fundamental insights into the chemical dynamics and intermixing between plasma-gas species in laser ablation cerium plasmas, advancing our understanding on optical signatures of nuclear-relevant materials to enable in-field measurement capabilities.

47 OTHER INSTRUMENTATION↗

A comparative analysis of YOLOv8 and U-Net image segmentation approaches for transmission electron micrographs of polycrystalline thin films

Metallic thin films offer a platform to experimentally study the dynamics of microstructural evolution, but the required transmission electron microscopy (TEM)-based imaging generates complex images that are challenging to segment and quantify. This work provides a comparative analysis of a new YOLOv8 model and an established U-Net model for bright-field TEM images of polycrystals, employing a framework leveraging physical observables to evaluate performance against two hand-traced benchmark datasets. This methodology obviates the comparison of large, diversely structured, and manually labeled datasets that are required to assess performance on a per-image/per-pixel basis. It is found that the YOLOv8 model, adapted for real-time instance segmentation, has up to 43× faster inferencing (NVIDIA GeForce RTX 4090) compared to U-Net and reconstructs hand-traced grain size distributions (GSDs) with excellent fidelity, finding mean diameter within 3% for grains near an optimal magnification; for grains that deviate from the optimal pixel-diameter, the size of small- (large)-diameter grains is systematically over- (under)-estimated. This is partially mitigated by including scale-aware augmentations during training. Moreover, when the bias is corrected post-inference by a rigid shift in distribution, the YOLOv8 model reproduces ground truth GSDs with exceptional fidelity, with statistical tests indicating <5% probability that the distributions are distinct. Based on ground truth data, calibration curves pertaining to this shift can be constructed for a given model. This issue is not present in the U-Net model’s results, indicating that for quantitative measurements where the true size of objects is of interest, special procedures must be implemented for YOLO-based models.

36 MATERIALS SCIENCE↗

GALAXY MODELING WITH COMPOUND ELLIPTICAL SHAPELETS

Gauss-Hermite and Gauss-Laguerre ('shapelet') decompositions of images have become important tools in galaxy modeling, particularly for the purpose of extracting ellipticity and morphological information from astronomical data. However, the standard shapelet basis functions cannot compactly represent galaxies with high ellipticity or large Sersic index, and the resulting underfitting bias has been shown to present a serious challenge for weak-lensing methods based on shapelets. We present here a new convolution relation and a compound 'multiscale' shapelet basis to address these problems and provide a proof-of-concept demonstration using a small sample of nearby galaxies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated imaging through atmospheric turbulence

Correlated imaging through atmospheric turbulence is studied, and the analytical expressions describing turbulence effects on image resolution are derived. Compared with direct imaging, correlated imaging can reduce the influence of turbulence to a certain extent and reconstruct high-resolution images. The result is backed up by numerical simulations, in which turbulence-induced phase perturbations are simulated by random-phase screens inserted into propagation paths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

SU-E-J-116: Uncertainties Associated with Dose Summation of High-Dose Rate Brachytherapy and Intensity Modulated Radiotherapy for Gynecological Cases

Purpose: Determining the cumulative dose distribution (CDD) for gynecological patients treated with both high-dose rate (HDR) brachytherapy and intensity-modulated radiotherapy (IMRT) is challenging. The purpose of this work is to study the uncertainty of performing this with a structure-guided deformable (SGD) approach in Velocity. Methods: For SGD, the Hounsfield units inside specified contours are overridden to set uniform values. Deformable image registration (DIR) is the run on these process images, which forces the DIR to focus on these contour boundaries. 18 gynecological cancer patients were used in this study. The original bladder and rectum planning contours for these patients were used to drive the SGD. A second set of contours were made of the bladder by the same person with the intent of carefully making them completely consistent with each other. This second set was utilized to evaluate the spatial accuracy of the SGD. The determined spatial accuracy was then multiplied by the local dose gradient to determine a dose uncertainty associated with the SGD dose warping. The normal tissue complication probability (NTCP) was then calculated for each dose volume histogram (DVH) that included four different probabilistic uncertainties associated with the spatial errors (e.g., 68.3% and 95.4%). Results: The NTCPs for each DVH (e.g., NTCP-−95.4%, NTCP-−68.3%, NTCP-68.3%, NTCP-95.4%) differed amongst patients. All patients had an NTCP-−95.4% close to 0%, while NTCP-95.4% ranged from 0.67% to 100%. Nine patients had an NTCP-−95.4% less than 50% while the remaining nine patients had NTCP-95.4% greater than 50%. Conclusion: The uncertainty associated with this CDD technique renders a large NTCP uncertainty. Thus, it is currently not practical for clinical use. The two ways to improve this would be to use more precise contours to drive the SGD and to use a more accurate DIR algorithm.

60 APPLIED LIFE SCIENCES↗

GSV Annotated Bibliography

The following annotated bibliography was developed as part of the Geospatial Algorithm Veri cation and Validation (GSV) project for the Simulation, Algorithms and Modeling program of NA-22. Veri cation and Validation of geospatial image analysis algorithms covers a wide range of technologies. Papers in the bibliography are thus organized into the following ve topic areas: Image processing and analysis, usability and validation of geospatial image analysis algorithms, image distance measures, scene modeling and image rendering, and transportation simulation models.

99 GENERAL AND MISCELLANEOUS↗

GSV Annotated Bibliography

The following annotated bibliography was developed as part of the geospatial algorithm verification and validation (GSV) project for the Simulation, Algorithms and Modeling program of NA-22. Verification and Validation of geospatial image analysis algorithms covers a wide range of technologies. Papers in the bibliography are thus organized into the following five topic areas: Image processing and analysis, usability and validation of geospatial image analysis algorithms, image distance measures, scene modeling and image rendering, and transportation simulation models. Many other papers were studied during the course of the investigation including. The annotations for these articles can be found in the paper "On the verification and validation of geospatial image analysis algorithms".

99 GENERAL AND MISCELLANEOUS↗

Poblano v1.0 : a Matlab toolbox for gradient-based optimization.

We present Poblano v1.0, a Matlab toolbox for solving gradient-based unconstrained optimization problems. Poblano implements three optimization methods (nonlinear conjugate gradients, limited-memory BFGS, and truncated Newton) that require only first order derivative information. In this paper, we describe the Poblano methods, provide numerous examples on how to use Poblano, and present results of Poblano used in solving problems from a standard test collection of unconstrained optimization problems.

99 GENERAL AND MISCELLANEOUS↗

The imaging photopolarimeter - The first extraterrestrial spin-scan imager

The paper describes the imaging photopolarimeter used to take close-ups of Jupiter from Pioneers 10 and 11. The instrument operates in a steerable spin-scan mode of operation, contains a 1 in. diameter, f/3.4 Maksutov telescope with a focal plane aperture whose size is selectable. The paper examines those aspects of the design that are substantially influenced by the unusual design constraints, such as choice of detector and method of steering the telescope, and demonstrates the image processing and display techniques used to create the images from the telemetry and correct them for distortion and other defects.

Swindell, W.↗

The Massively Parallel Processor and its applications

A long-term experimental development program conducted at Goddard Space Flight Center to implement an ultrahigh-speed data processing system known as the Massively Parallel Processor (MPP) is described. The MPP is a single instruction multiple data stream computer designed to perform logical, integer, and floating point arithmetic operations on variable word length data. Information is presented on system architecture, the system configuration, the array unit architecture, individual processing units, and expected operating rates for several image processing applications (including the processing of Landsat data).

Strong, J. P.↗

Applications of HCMM satellite data to the study of urban heating patterns

A research summary is presented and is divided into two major areas, one developmental and the other basic science. In the first three sub-categories are discussed: image processing techniques, especially the method whereby surface temperature image are converted to images of surface energy budget, moisture availability and thermal inertia; model development; and model verification. Basic science includes the use of a method to further the understanding of the urban heat island and anthropogenic modification of the surface heating, evaporation over vegetated surfaces, and the effect of surface heat flux on plume spread.

Carlson, T. N.↗

Forest Resource Information System. Phase 3: System transfer report

Transfer of the forest reserve information system (FRIS) from the Laboratory for Applications of Remote Sensing to St. Regis Paper Company is described. Modifications required for the transfer of the LARYS image processing software are discussed. The reformatting, geometric correction, image registration, and documentation performed for preprocessing transfer are described. Data turnaround was improved and geometrically corrected and ground-registered CCT LANDSAT 3 data provided to the user. The technology transfer activities are summarized. An application test performed in order to assess a Florida land acquisition is described. A benefit/cost analysis of FRIS is presented.

Mroczynski, R. P.↗