Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hands-On Computer Science: The Array of Things Experimental Urban Instrument

Chicago's Array of Things (AoT) project is aptly described as a technology experiment or a "smart city" prototype. The concept of such an extensible "instrument" arose within a larger translational research vision applying computer science and engineering research for the multidimensional benefit of people and communities in cities. The AoT project hypothesized that wireless intelligent sensor networks could enable both quantitative social science and urban monitoring while also stimulating youth interest in science and technology. Successful deployment of such sensor networks could provide open data from urban measurements not only in support of diverse research questions-in environmental dynamics, urban architecture, engineering, and social sciences-but also informing community groups and city planners. Further, the AoT project and its successor SAGE project are a computer science and engineering experiment, but its success is inextricably tied to community engagement and experiential education. Simply put, community acceptance is a prerequisite to installing and testing the instrument.

97 MATHEMATICS AND COMPUTING↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Statistics-Based Correction to Measurements of Hardness of Rough Surfaces by Instrumented Indentation

Abstract—A procedure for correcting hardness data measured on rough surfaces using instrumented indentation is presented. The correction procedure relies on the knowledge of surface topography, which can be obtained by atomic force microscopy or other appropriate instrumental technique. The analyzed surface is characterized by the standard deviation of height distribution and an autocorrelation function. The latter is proposed to be modeled with an exponential function with either a quadratic or linear exponent.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

It is conventionally expected that the performance of existing gas sensors may degrade in the field compared to laboratory conditions because (i) a sensor may lose its accuracy in the presence of chemical interferences and (ii) variations of ambient conditions over time may induce sensor-response fluctuations (i.e., drift). Breaking this status quo in poor sensor performance requires understanding the origins of design principles of existing sensors and bringing new principles to sensor designs. Existing gas sensors are single-output (e.g., resistance, electrical current, light intensity, etc.) sensors, also known as zero-order sensors (Karl Booksh and Bruce R. Kowalski, Analytical Chemistry, DOI: 10.1021/ac00087a718). Any zero-order sensor is undesirably affected by variable chemical background and sensor drift that cannot be distinguished from the response to an analyte. To address these limitations, we are developing multivariable gas sensors with independent responses, which are first-order analytical instruments. Here, we demonstrate self-correction against drift in two types of first-order gas sensors that operate in different portions of the electromagnetic spectrum. Our radiofrequency sensors utilize dielectric excitation of semiconducting metal oxide materials on the shoulder of their dielectric relaxation peak and achieve self-correction of the baseline drift by operation at several frequencies. Our photonic sensors utilize nanostructured sensing materials inspired by Morpho butterflies and achieve self-correction of the baseline drift by operation at several wavelengths. These principles of self-correction for drift effects in first-order sensors open opportunities for diverse emerging monitoring applications that cannot afford frequent periodic maintenance that is typical of traditional analytical instruments.

Potyrailo, Radislav A.↗

Anomaly Detection in Seismic Data with Deep Learning: Application for Instrument Failure Detection and Forecasting

Seismic data quality assessment (QA) is the first and one of the most important steps before conducting any further data analysis. Traditional methods involve checking various metrics, such as spike detection and power spectral density, by setting strict thresholds or comparing data against synthetic benchmarks. However, these approaches often rely on pre-existing knowledge and assumptions about data anomalies, leading to potential misclassification of unusual cases. Here, in this study, we propose a deep autoencoder model, an unsupervised learning approach that evaluates data quality without making assumptions about normal and anomalous data, which can be used to identify deviations in recorded data that may indicate nascent instrument failure. We test the model with the U.S. International Monitoring System (IMS) seismic stations and demonstrate the capability of detecting anomalies on a monthly scale. This could prompt station operators to examine potential problems early, allowing sufficient time for instrument maintenance to prevent data outages. In addition, we use a new manually selected testing dataset to compare our model performance against two supervised machine learning (ML) approaches and a standard QA package, as baseline models. When applied to the dataset containing known data anomalies, performance of the supervised and unsupervised ML approaches is similar, with an accuracy of 88.1% for our model compared to ∼90% for the supervised ML approach and 78.2% for the standard QA package. Our model outperforms the baseline models when applied to new stations, where new types of data anomalies can be station-specific and not included in the training dataset. Finally, we show model transferability by training the model with data from the Global Seismograph Network only and applying it to the IMS network data. The results suggest that our model is generalizable and can be applied to new stations with good accuracy.

Lin, Jiun-Ting [Lawrence Livermore National Labora↗

Beam Instrumentation Challenges for the Fermilab PIP-II Accelerator

Fermilab is undertaking the development of a new 800 MeV superconducting RF linac to replace it’s present normal conducting 400 MeV linac. The PIP-II linac warm front-end consists of an ion source, LEBT, RFQ and MEBT which includes an arbitrary pattern bunch chopper, to generate a 2.1 MeV, 2mA H⁻ beam. This is followed immediately by a series of superconducting RF cryomodules to produce a 800 MeV beam. Commissioning, operate and safety present challenges to the beam instrumentation. This paper describes these beam instrumentation challenges and the choices made for PIP-II.

43 PARTICLE ACCELERATORS↗

Raman Lidar (RL) Instrument Handbook

The Raman lidar at the ARM Climate Research Facility (ACRF) Southern Great Plains (SGP) Central Facility (SGPRL) is an active, ground-based laser remote sensing instrument that measures height and time resolved profiles of water vapor mixing ratio and several cloud- and aerosol-related quantities. The system is a non-commercial custom-built instrument developed by Sandia National Laboratories specifically for the ARM Program. It is fully computer automated, and will run unattended for many days following a brief (~5-minute) startup period. The self-contained system (requiring only external electrical power) is housed in a climate-controlled 8’x8’x20’ standard shipping container.

54 ENVIRONMENTAL SCIENCES↗

Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) Instrument Handbook

The Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS) (Figure 1) is an optical-scattering, laser-based aerosol particle spectrometer system for sizing particles in the 60 to 1000 nanometer (nm) range [1–3]. The instrument counts particles in up to 100 user-specified sizing bins. The instrument’s laser illuminates particles, which scatter light. The system captures the peak light signals that are generated. These signals are used for particle sizing, since the amount of light scattered correlates strongly with particle size.

54 ENVIRONMENTAL SCIENCES↗

An Instrumented Uranium Hemispherical Casting

This work describes an instrumented uranium casting experiment and the analysis of the results. The casting is a hemisphere with inner radius of 75 mm and wall thickness of 10 mm. Casting was performed in a multi-coil vacuum induction melting (VIM) furnace with separate induction power supplies for each coil. One coil was used to heat the crucible and melt the charge material. The second coil was used to heat the top of the mold in order to preheat the mold and obtain the desired initial mold temperature. The current, voltage, and frequency of the mold coil was measured during mold heating. The mold filling rate was measured by a load cell was placed under the mold stack. The thermal history of the casting was measured by 7 thermocouples in the casting cavity and 22 thermocouples imbedded in the graphite mold. Contact pins were also located in the mold to attempt to measure gap formation in the metal-mold interface. This instrumentation provides an in-depth thermal history of the mold heat-up, mold filling, solidification, and cool down. The thermocouples were positioned to allow for the casting/mold interfacial heat transfer coefficient to be determined as a function of position and time. The casting was sectioned and metallography and chemical analysis was performed.

36 MATERIALS SCIENCE↗

A Traditional Look at SPE Phase 1 Surface Seismic Data: Far-Field Instruments, Measurements, and Analysis

We visually examined surface seismic data from the Source Physics Experiment (SPE) Phase-1 chemical explosions in preparation for waveform analysis and interpretation. Recording stations included far-field (near source) geophone lines, and both permanent network, reoccupied USArray, and temporary stations at local and regional distances. We found that near-source waveforms are dominated by broad band compressional (P), and band limited surface wave (Rg) (< 10 Hz) phases. Distinct, consistent shear (S) phases are difficult to observe visually even with a comprehensive bank of frequency bands. Secondary phases are indistinct at near-local distances, unlike for earthquake sources, especially at the high frequencies of interest for discrimination (e.g. 4-8 Hz), likely due to intense near surface scattering. S phases begin to emerge from the scattered background at and beyond 100 km. We identified regional Pn, Pg and Lg phases to 446 km for SPE-5. The data set is, unfortunately, plagued by poorly recorded instrument responses, or, possibly, time varying site amplification due to human interaction with sensors. Instrument response issues should be fixable, and this should be attempted to make this a truly, high-quality data set for use by the monitoring community.

58 GEOSCIENCES↗

Instrumented Lid - System Final Design

Work is ongoing to create an instrumented and sampling system for monitoring aluminum clad spent nuclear fuel (ASNF) in dry storage. The anticipated system will be composed of a custom canister assembly and a modular instrument manifold. The conceptual design was first laid out in the Task Technical and Quality Assurance Plan (SRNL-RP-2019-00225). In this document, we outline the project progress to date, and describe the final system design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRIMA-X - Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing

The PRIMA-X (Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing) project is the successor of the DOE PRIMA (Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing) project, which addressed the challenge of creating a core measurement infrastructure that would serve as a common platform for both integrating leading parallel performance systems (notably TAU and Scalasca) and developing next-generation scalable performance tools. The PRIMA-X project shifts the focus away from refactorization of robust performance tools towards a re-targeting of the parallel performance measurement and analysis architecture for extreme scales. The massive concurrency, asynchronous execution dynamics, hardware heterogeneity, and multi-objective prerequisites (performance, power, resilience) that identify exascale systems introduce fundamental constraints on the ability to carry forward existing performance methodologies. In particular, there must be a deemphasis of per-thread observation techniques to significantly reduce the otherwise unsustainable flood of redundant performance data. Instead, it will be necessary to assimilate multi-level resource observations into macroscopic performance views, from which resilient performance metrics can be attributed to the computational features of the application. This requires a scalable framework for node-level and system-wide monitoring and runtime analyses of dynamic performance information. Also, the interest in optimizing parallelism parameters with respect to performance and energy drives the integration of tool capabilities in the exascale environment further. Initially, PRIMA-X was a collaborative project between the University of Oregon (lead institution) and the German Research School for Simulation Sciences (GRS). Because Prof. Wolf, the PI at GRS, accepted a position as full professor at Technische Universitaet Darmstadt (TU Darmstadt) starting February 1st, 2015, the work of GRS was continued at TU Darmstadt. This report covers the work at TU Darmstadt after the transition. The first main accomplishment of TU Darmstadt is the development of different techniques to aggregate performance data on the level of threads. TU Darmstadt evaluated different schemes designed at GRS during the first phase of this project and integrated them into Score-P, a widely used performance measurement framework for HPC applications. The second main accomplishment is a substantial increase of Score-P’s scalability, achieved by improving its internal representation of the underlying system. Third, we extended our performance-modeling tool Extra-P to automatically create models with more than one input parameter (e.g., process count and input size), which was previously impossible. These models allow the performance behavior of an application to be extrapolated to larger machines. Specific applications of the new multi-parameter capability realized in this project include modeling the isoefficiency function of task-based applications and a novel co-design methodology. Further extensions of Extra-P comprise online modeling functionality, automatic refinement of the model search space, and segmented performance modeling. Further contributions include new locality metrics for both shared- and distributed-memory applications, a new way of measuring the impact of inter-application inference on the execution time of an application, and finally an automatic method that selects appropriate OpenMP constructs for the parallelization of sequential code and classifies the affected variables based on their sharing semantics.

97 MATHEMATICS AND COMPUTING↗

Fast Cloud Droplet Probe (FCDP) Instrument Handbook

The fast cloud droplet probe (FCDP) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring the concentration and size of cloud droplets in the diameter size range 1.5-50 μm. It is an open-path instrument mounted on the outside of the aircraft (typically below the wing). When a droplet passes through the sample volume, light from a laser source is scattered, which is used to detect and size the droplet. The sample volume is a focused area of the laser beam that is continuously monitored along the flight path. If a droplet crosses the laser beam but is outside the sample volume, a separate detector will reject the droplet. Only single droplets at a time will be detected and sizes measured over one second have to be averaged to obtain a size distribution. When measuring ice clouds, the FCDP will not yield useful information, since the measurement method, which assumes spherical particles to obtain size and scattering, is very different for ice crystals.

54 ENVIRONMENTAL SCIENCES↗

High-Volume Precipitation Spectrometer (HVPS) Instrument Handbook

The high-volume precipitation spectrometer (HVPS) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring hydrometeors larger than 150 μm. It is an open-path instrument located on the outside of the aircraft, typically below the wing. A laser sheet throws a shadowgraph image of the hydrometeor (cloud droplets or ice crystals) in the sample volume on a photodiode array. As the hydrometeor moves through the sample volume, this optical array records the moving shape and a two-dimensional picture can be recorded. At an air speed of 100 m/s, the sample volume is 310 l/s. The recorded images can be analyzed for size distributions, number concentrations, and further cloud properties detailed below. Hydrometeors in the range of 0.3-19.2 mm can be fully recorded at a 150 μm resolution; larger particles can only be sized along the direction of flight.

54 ENVIRONMENTAL SCIENCES↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗