Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Dark energy survey year 3 results: High-precision measurement and modeling of galaxy-galaxy lensing

We present and characterize the galaxy-galaxy lensing signal measured using the first three years of data from the Dark Energy Survey (DES Y3) covering 4132 deg 2 . These galaxy-galaxy measurements are used in the DES Y3 3 × 2 pt cosmological analysis, which combines weak lensing and galaxy clustering information. We use two lens samples: a magnitude-limited sample and the redmagic sample, which span the redshift range ∼ 0.2 – 1 with 10.7 and 2.6 M galaxies, respectively. For the source catalog, we use the metacalibration shape sample, consisting of ≃ 100 M galaxies separated into four tomographic bins. Our galaxy-galaxy lensing estimator is the mean tangential shear, for which we obtain a total SNR of ∼ 148 for maglim ( ∼ 120 for redmagic), and ∼ 67 ( ∼ 55 ) after applying the scale cuts of 6 Mpc / h . Thus we reach percent-level statistical precision, which requires that our modeling and systematic-error control be of comparable accuracy. The tangential shear model used in the 3 × 2 pt cosmological analysis includes lens magnification, a five-parameter intrinsic alignment model, marginalization over a point mass to remove information from small scales and a linear galaxy bias model validated with higher-order terms. We explore the impact of these choices on the tangential shear observable and study the significance of effects not included in our model, such as reduced shear, source magnification, and source clustering. We also test the robustness of our measurements to various observational and systematics effects, such as the impact of observing conditions, lens-source clustering, random-point subtraction, scale-dependent metacalibration responses, point spread function residuals, and B modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards local progression estimation of pulmonary emphysema using CT

Purpose: Whole lung densitometry on chest CT images is an accepted method for measuring tissue destruction in patients with pulmonary emphysema in clinical trials. Progression measurement is required for evaluation of change in health condition and the effect of drug treatment. Information about the location of emphysema progression within the lung may be important for the correct interpretation of drug efficacy, or for determining a treatment plan. The purpose of this study is therefore to develop and validate methods that enable the local measurement of lung density changes, which requires proper modeling of the effect of respiration on density. Methods: Four methods, all based on registration of baseline and follow-up chest CT scans, are compared. The first naïve method subtracts registered images. The second employs the so-called dry sponge model, where volume correction is performed using the determinant of the Jacobian of the transformation. The third and the fourth introduce a novel adaptation of the dry sponge model that circumvents its constant-mass assumption, which is shown to be invalid. The latter two methods require a third CT scan at a different inspiration level to estimate the patient-specific density-volume slope, where one method employs a global and the other a local slope. The methods were validated on CT scans of a phantom mimicking the lung, where mass and volume could be controlled. In addition, validation was performed on data of 21 patients with pulmonary emphysema. Results: The image registration method was optimized leaving a registration error below half the slice increment (median 1.0 mm). The phantom study showed that the locally adapted slope model most accurately measured local progression. The systematic error in estimating progression, as measured on the phantom data, was below 2 gr/l for a 70 ml (6%) volume difference, and 5 gr/l for a 210 ml (19%) difference, if volume correction was applied. On the patient data an underlying linearity assumption relating lung volume change with density change was shown to hold (fitR{sup 2} = 0.94), and globalized versions of the local models are consistent with global results (R{sup 2} of 0.865 and 0.882 for the two adapted slope models, respectively). Conclusions: In conclusion, image matching and subsequent analysis of differences according to the proposed lung models (i) has good local registration accuracy on patient data, (ii) effectively eliminates a dependency on inspiration level at acquisition time, (iii) accurately predicts progression in phantom data, and (iv) is reasonably consistent with global results in patient data. It is therefore a potential future tool for assessing local emphysema progression in drug evaluation trials and in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRB-02: Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)

Purpose: To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans. Methods: For prostate SBRT cases, four segments of rectal walls including peri-prostatic anterior rectal wall, peri-prostatic lateral rectal walls, peri-prostatic posterior rectal wall and rectum superior to prostate are identified as organs at risk and the circumference of rectal wall receiving more than 39 Gy (CRW39) and 24 Gy (CRW24) are rectal toxicity predictors. In this new geometry-dosimetry model, a patient geometry descriptor, differential circumference of rectal wall (dCRW) is used as model input geometry parameters and plan dosimetric endpoints CRW39 and CRW24 are output dosimetric parameters. Linear models are built to correlate dCRW to both CRW39 and CRW24 and established with both a linear regression method and a modified bagging ensemble machine learning method. 27 SBRT prostate cases are retrospectively studied from a dose-escalated clinical trial research. 20 prescribed 50 Gy SBRT cases are recruited to train the model and the other rescaled 7 cases are used to evaluated model feasibility and accuracy. Results: Each solved linear coefficient sequence related to CRW39 or CRW24 is a one-dimensional decreasing function of the distance from the PTV boundary, indicating that the different locations of each rectal circumference have different contributions to each particular dosimetric endpoint. The fitting errors for those trained 20 prostate SBRT cases are small with mean values of 2.39%, 2.45% relative to the endpoint values for SBRT rectal toxicity predictor CRW39 and CRW24 respectively. 1 out of 7 evaluation plans is identified as poor quality plan. After re-planning, the CRW39 and CRW24 can be reduced by 3.34% and 3%, without sacrificing PTV coverage. Conclusion: The proposed patient geometry-plan toxicity predictor model for SBRT plans can be successfully applied to plan quality control for prostate SBRT cases.

60 APPLIED LIFE SCIENCES↗

Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams

Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrochemical Characterization of Dissolved Oxides in Molten FLiNaK

Molten fluoride salts have long been the subject of investigation given their application in a variety of industrial processes. Oxides are a common exogeneous impurity within these systems, and can lead to many operational and regulatory concerns. In recent studies, the electro-oxidation of dissolved metallic oxides has been attributed to a single step oxygen evolution reaction despite voltametric evidence suggesting otherwise. Here, we first use square wave voltammetry to confirm that the oxidation of dissolved oxides in fluorides proceeds via a two-electron transfer reaction and then demonstrate that the presence of a peroxide-mediated redox reaction better explains the electrochemical data. Numerical simulations were then used to support the determination of improved diffusion coefficients to enable electroanalytical measurements of the oxide concentration across at a variety of temperatures. A linear Arrhenius relationship was observed when the experimental data was corrected for ohmic resistance effects. Concentration measurements using the corrected square wave voltammetry data demonstrated high accuracy across a large range of concentrations, while the uncorrected data showed plateauing and high errors. In total, this work serves to rectify previously misconstrued electrochemical data of oxides in molten salts and demonstrate how accurate, in situ concentration measurements can be achieved in real-world systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Galerkin v. discrete-optimal projection in nonlinear model reduction

Discrete-optimal model-reduction techniques such as the Gauss{Newton with Approximated Tensors (GNAT) method have shown promise, as they have generated stable, accurate solutions for large-scale turbulent, compressible ow problems where standard Galerkin techniques have failed. However, there has been limited comparative analysis of the two approaches. This is due in part to difficulties arising from the fact that Galerkin techniques perform projection at the time-continuous level, while discrete-optimal techniques do so at the time-discrete level. This work provides a detailed theoretical and experimental comparison of the two techniques for two common classes of time integrators: linear multistep schemes and Runge{Kutta schemes. We present a number of new ndings, including conditions under which the discrete-optimal ROM has a time-continuous representation, conditions under which the two techniques are equivalent, and time-discrete error bounds for the two approaches. Perhaps most surprisingly, we demonstrate both theoretically and experimentally that decreasing the time step does not necessarily decrease the error for the discrete-optimal ROM; instead, the time step should be `matched' to the spectral content of the reduced basis. In numerical experiments carried out on a turbulent compressible- ow problem with over one million unknowns, we show that increasing the time step to an intermediate value decreases both the error and the simulation time of the discrete-optimal reduced-order model by an order of magnitude.

CFD↗

HIGH-PRECISION PREDICTIONS FOR THE ACOUSTIC SCALE IN THE NONLINEAR REGIME

We measure shifts of the acoustic scale due to nonlinear growth and redshift distortions to a high precision using a very large volume of high-force-resolution simulations. We compare results from various sets of simulations that differ in their force, volume, and mass resolution. We find a consistency within 1.5{sigma} for shift values from different simulations and derive shift {alpha}(z) - 1 = (0.300 {+-} 0.015) %[D(z)/D(0)]{sup 2} using our fiducial set. We find a strong correlation with a non-unity slope between shifts in real space and in redshift space and a weak correlation between the initial redshift and low redshift. Density-field reconstruction not only removes the mean shifts and reduces errors on the mean, but also tightens the correlations. After reconstruction, we recover a slope of near unity for the correlation between the real and redshift space and restore a strong correlation between the initial and the low redshifts. We derive propagators and mode-coupling terms from our N-body simulations and compare with the Zel'dovich approximation and the shifts measured from the {chi}{sup 2} fitting, respectively. We interpret the propagator and the mode-coupling term of a nonlinear density field in the context of an average and a dispersion of its complex Fourier coefficients relative to those of the linear density field; from these two terms, we derive a signal-to-noise ratio of the acoustic peak measurement. We attempt to improve our reconstruction method by implementing 2LPT and iterative operations, but we obtain little improvement. The Fisher matrix estimates of uncertainty in the acoustic scale is tested using 5000 h {sup -3} Gpc{sup 3} of cosmological Particle-Mesh simulations from Takahashi et al. At an expected sample variance level of 1%, the agreement between the Fisher matrix estimates based on Seo and Eisenstein and the N-body results is better than 10%.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-173: Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images

Purpose: Deformable Image Registration (DIR) is gaining wider clinical acceptance in radiation oncology. The aim of this work is to characterise a DIR algorithm on publically available 4DCT lung images, such that comparison can be performed against other algorithms. We propose an evaluation method of registration accuracy that takes into account the initial misregistration of the datasets. Methods: The “DIR Validation dataset” ( http://www.creatis.insa-lyon.fr/rio/dir{sub v}alidation{sub d}ata ) provides benchmark data for evaluating 3D CT registration algorithms. It consists of six 4DCT lung datasets (1x1x2mm resolution) with 100 landmarks identified on the end-exhalation and end-inhalation phases. Images were registered to end-inhalation using proprietary form of optical flow in commercial software (Mirada RTx, Mirada Medical, UK). Target registration error was measured before and after DIR, referred to as Initial Registration Error (IRE) and Final Registration Error (FRE). Results: The mean FRE over all landmarks was 1.37±1.81mm. FRE increased with IRE. Mean FRE of 0.86, 0.86, 1.53, 3.38, 4.45, 7.58mm was observed for IRE in the ranges 0–5, 5–10, 10–15, 15–20, 20–25, >25 mm. Higher FRE was observed at the inferior lung, where IRE was greater. Out-of-plane motion contributed more to IRE, and therefore to FRE. Maximum FRE of 20.6mm was observed for IRE of 32.1mm, located at the posterior of the middle lobe for dataset 2. Sub-voxel registration accuracy was achieved for up to 10mm IRE, and increased linearly at 0.3mm FRE/mm IRE thereafter. Conclusion: Publicly available clinical datasets enable algorithms to be compared objectively between publications. However, only reporting average TRE after registration can be misleading as the ability of an algorithm to correct for displacements varies with the IRE or position within the patient. Consequently, algorithms should be characterized using the entire range of initial displacements. For the algorithm assessed, clinically acceptable error within one voxel was achieved for IRE of up to 15mm. TK, AL, and MG are employees of Mirada Medical.

60 APPLIED LIFE SCIENCES↗

Superconvergence analysis for nonlinear parabolic equation with EQ{sub 1}{sup rot} nonconforming finite element

EQ{sub 1}{sup rot} nonconforming finite element method (FEM) applied to a class of nonlinear parabolic equation is discussed. First, by use of two typical characters of this element (one is that the associated FE interpolation operator is identical to its traditional Ritz projection operator; the other is that the consistency error is of order O(h{sup 2}), one order higher than the interpolation error, when the exact solution of the problems belongs to H{sup 3}(Ω)), the supercloseness of order O(h{sup 2}) in broken H{sup 1}-norm for semi-discrete scheme is obtained without the boundedness of numerical solution in L{sup ∞}-norm through splitting the numerical solution into several parts. Moreover, we get the desired result with requirement of u,u{sub t}∈H{sup 3}(Ω) only. Secondly, a linearized Crank–Nicolson fully discrete scheme is proposed and the superclose property of order O(h{sup 2}+τ{sup 2}) is derived by constructing a suitable auxiliary problem. Finally, a numerical example is carried out to confirm our theoretical analysis. Here, h is the subdivision parameter and τ is the time step.

97 MATHEMATICS AND COMPUTING↗

ON THE MINIMAL ACCURACY REQUIRED FOR SIMULATING SELF-GRAVITATING SYSTEMS BY MEANS OF DIRECT N-BODY METHODS

The conservation of energy, linear momentum, and angular momentum are important drivers of our physical understanding of the evolution of the universe. These quantities are also conserved in Newton's laws of motion under gravity. Numerical integration of the associated equations of motion is extremely challenging, in particular due to the steady growth of numerical errors (by round-off and discrete time-stepping and the exponential divergence between two nearby solutions. As a result, numerical solutions to the general N-body problem are intrinsically questionable. Using brute force integrations to arbitrary numerical precision we demonstrate empirically that ensembles of different realizations of resonant three-body interactions produce statistically indistinguishable results. Although individual solutions using common integration methods are notoriously unreliable, we conjecture that an ensemble of approximate three-body solutions accurately represents an ensemble of true solutions, so long as the energy during integration is conserved to better than 1/10. We therefore provide an independent confirmation that previous work on self-gravitating systems can actually be trusted, irrespective of the intrinsically chaotic nature of the N-body problem.

79 ASTRONOMY AND ASTROPHYSICS↗

SYSTEMATIC EFFECTS IN INTERFEROMETRIC OBSERVATIONS OF THE COSMIC MICROWAVE BACKGROUND POLARIZATION

The detection of the primordial B-mode spectrum of the polarized cosmic microwave background (CMB) signal may provide a probe of inflation. However, observation of such a faint signal requires excellent control of systematic errors. Interferometry proves to be a promising approach for overcoming such a challenge. In this paper we present a complete simulation pipeline of interferometric observations of CMB polarization, including systematic errors. We employ two different methods for obtaining the power spectra from mock data produced by simulated observations: the maximum likelihood method and the method of Gibbs sampling. We show that the results from both methods are consistent with each other as well as, within a factor of six, with analytical estimates. Several categories of systematic errors are considered: instrumental errors, consisting of antenna gain and antenna coupling errors; and beam errors, consisting of antenna pointing errors, beam cross-polarization, and beam shape (and size) errors. In order to recover the tensor-to-scalar ratio, r, within a 10% tolerance level, which ensures the experiment is sensitive enough to detect the B-signal at r = 0.01 in the multipole range 28 < l < 384, we find that, for a QUBIC-like experiment, Gaussian-distributed systematic errors must be controlled with precisions of |g{sub rms}| = 0.1 for antenna gain, |{epsilon}{sub rms}| = 5 Multiplication-Sign 10{sup -4} for antenna coupling, {delta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for pointing, {zeta}{sub rms} Almost-Equal-To 0. Degree-Sign 7 for beam shape, and {mu}{sub rms} = 5 Multiplication-Sign 10{sup -4} for beam cross-polarization. Although the combined systematic effects produce a tolerance level on r twice as large for an experiment with linear polarizers, the resulting bias in r for a circular experiment is 15% which is still on the level of desirable sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the effect of wind speed and direction shear on utility‐scale wind turbine power production

Abstract Wind speed and direction variations across the rotor affect power production. As utility‐scale turbines extend higher into the atmospheric boundary layer (ABL) with larger rotor diameters and hub heights, they increasingly encounter more complex wind speed and direction variations. We assess three models for power production that account for wind speed and direction shear. Two are based on actuator disc representations, and the third is a blade element representation. We also evaluate the predictions from a standard power curve model that has no knowledge of wind shear. The predictions from each model, driven by wind profile measurements from a profiling LiDAR, are compared to concurrent power measurements from an adjacent utility‐scale wind turbine. In the field measurements of the utility‐scale turbine, discrete combinations of speed and direction shear induce changes in power production of −19% to +34% relative to the turbine power curve for a given hub height wind speed. Positive speed shear generally corresponds to over‐performance and increasing magnitudes of direction shear to greater under‐performance, relative to the power curve. Overall, the blade element model produces both higher correlation and lower error relative to the other models, but its quantitative accuracy depends on induction and controller sub‐models. To further assess the influence of complex, non‐monotonic wind profiles, we also drive the models with best‐fit power law wind speed profiles and linear wind direction profiles. These idealized inputs produce qualitative and quantitative differences in power predictions from each model, demonstrating that time‐varying, non‐monotonic wind shear affects wind power production.

Energy & Fuels↗

Monitoring of corrosion effects in pipes with multi-mode acoustic signals

Current commercial long-range guided wave inspection and monitoring technologies for pipes usually require establishment of certain specific acoustic modes for wave propagation and use a large number of sensors in a certain geometric arrangement (for example, uniformly-spaced arrays of sensors on a collar, placed around a pipe). This paper, in contrast, presents a long-range corrosion detection method in pipes based on multi-mode guided acoustic waves, generated and received using simple, single-element sensors. In this technique, available guided wave modes in any interrogated zone of the structure are automatically down-selected by the medium, and changes in energy distribution over the selected modes are analyzed through signal processing to monitor material loss or addition. Here, to investigate the feasibility of the proposed method, we have performed both experimental and numerical simulation studies on 50.8-mm (2-in)-diameter schedule-40 carbon steel pipes. In these studies, a linear chirp signal is injected in compression mode, perpendicular to the surface of the pipe, generating multi-mode, multi-directional guided waves that travel within the pipe wall. Corrosion effects in the pipes are simulated numerically and experimentally. To reduce errors in the measurement technique due to changes in the local or global temperature of the measured media, a universal temperature compensation algorithm is introduced. The experimental results show good agreement with simulation results, indicating that the proposed multi-mode wave generation and detection in a pipe could be used for long-range detection and monitoring of corrosion effects, such as pipe wall losses or solid material deposits.

36 MATERIALS SCIENCE↗

Improved single-particle phase-space distributions for viscous fluid dynamic models of relativistic heavy ion collisions

Comparison of hydrodynamic calculations with experimental data inevitably requires a model for converting the fluid to particles. For shear viscous fluids, several different conversion models have been proposed, such as the quadratic Grad corrections, the Strickland-Romatschke (SR) ansatz, self-consistent shear corrections from linearized kinetic theory, or corrections from the relaxation time approach. We show, via comparison to nonlinear 2 → 2 kinetic theory evolution, that even for low specific shear viscosities 0.03 ≲ $\textit{η/s}$ ≲ 0.2 , these four models have varying accuracy and still significant errors in reproducing particle phase space densities from hydrodynamic fields. Moreover, we demonstrate that the overall reconstruction error of additive shear viscous $f = f_{eq} + δf$ models dramatically reduces by up to one order of magnitude, if one ensures through exponentiation that $\textit{f}$ is always positive. Further, we also illustrate how even more accurate viscous $\textit{δf}$ models can be constructed by incorporating the first time derivatives of hydrodynamic fields to account for the past evolution of the system. Such time derivatives are readily available in hydrodynamic simulations, though usually not included in the output. Though our comparisons are limited to a one-component massless system undergoing a (0 + 1)-dimensional (0 + 1D) longitudinal boost-invariant expansion, we expect that the improved models will be useful in 2 + 1D and 3 + 1D hydrodynamic studies as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multivariate Predictive Analytics of Wind Power Data for Robust Control of Energy Storage

Short-term forecasting is frequently identified as an important tool for the effective management of wind generation. However, forecasting errors, inherent to the point forecasts, increase requirements for energy storage and can affect optimal system operation. Probabilistic forecasts can help tackle this issue by providing a proper characterization of forecasting errors in the optimization process. This paper proposes a multivariate model of forecasting data for wind generation. Predictive uncertainty intervals of wind power can be obtained by sampling from the proposed model. The main goal is to use empirical data models without linear or Gaussian approximations of the distributional or temporal variations. The predictive modeling is utilized within a case study of an energy storage system. Finally, a modified robust convex programming is used to maintain the practical robustness and feasibility of the solution based on the sampled scenarios from the model.

17 WIND ENERGY↗

WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides a framework to evaluate angiographic system performance.

60 APPLIED LIFE SCIENCES↗

SU-F-J-88: Comparison of Two Deformable Image Registration Algorithms for CT-To-CT Contour Propagation

Purpose: To compare the contour propagation accuracy of two deformable image registration (DIR) algorithms in the Raystation treatment planning system – the “Hybrid” algorithm based on image intensities and anatomical information; and the “Biomechanical” algorithm based on linear anatomical elasticity and finite element modeling. Methods: Both DIR algorithms were used for CT-to-CT deformation for 20 lung radiation therapy patients that underwent treatment plan revisions. Deformation accuracy was evaluated using landmark tracking to measure the target registration error (TRE) and inverse consistency error (ICE). The deformed contours were also evaluated against physician drawn contours using Dice similarity coefficients (DSC). Contour propagation was qualitatively assessed using a visual quality score assigned by physicians, and a refinement quality score (0 0.9 for lungs, > 0.85 for heart, > 0.8 for liver) and similar qualitative assessments (VQS < 0.35, RQS > 0.75 for lungs). When anatomical structures were used to control the deformation, the DSC improved more significantly for the biomechanical DIR compared to the hybrid DIR, while the VQS and RQS improved only for the controlling structures. However, while the inclusion of controlling structures improved the TRE for the hybrid DIR, it increased the TRE for the biomechanical DIR. Conclusion: The hybrid DIR was found to perform slightly better than the biomechanical DIR based on lower TRE while the DSC, VQS, and RQS studies yielded comparable results for both. The use of controlling structures showed considerable improvement in the hybrid DIR results and is recommended for clinical use in contour propagation.

60 APPLIED LIFE SCIENCES↗

Non-Invasive Electrode Impedance Estimation for Optimized Charge Profile Parameterization of Lithium-Ion Batteries

This work presents a non-invasive method for parameterizing a physically motivated equivalent circuit model of lithium-ion batteries using operando electrochemical impedance spectroscopy and time-domain data. The proposed model consists exclusively of linear circuit elements, enabling computationally efficient simulation and real-time implementation on battery management system chips. By integrating frequency- and time-domain measurements, the model accurately estimates internal states such as the negative electrode potential, achieving a root mean square error of 12.3 mV during fast charging validation. Parameterization requires only rate tests with sinusoidal perturbations at three different ambient temperatures, making the approach experimentally accessible. The model reveals key insights into battery behavior, including rate-dependent overpotentials primarily governed by charge transfer kinetics at the positive electrode, and temperature-dependent impedance contributions from both charge transfer and solid-state diffusion processes. Validation using reference electrodes confirms the model’s ability to detect lithium plating onset and reproduce impedance behavior across a wide range of operating conditions. The approach enables in situ optimization of fast charging profiles and lays the foundation for future extensions incorporating aging effects and plating dynamics.

25 ENERGY STORAGE↗