Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Recent Performance of the SNS H- ion source and low-energy beam transport system

Recent measurements of the H beam current show that SNS is injecting about 55 mA into the RFQ compared to 45 mA in 2010. Since 2010, the H beam exiting the RFQ dropped from 40 mA to 34 mA, which is sufficient for 1 MW of beam power. To minimize the impact of the RFQ degradation, the service cycle of the best performing source was extended to 6 weeks. The only degradation is fluctuations in the electron dump voltage towards the end of some service cycles, a problem that is being investigated. Very recently, the RFQ was retuned, which partly restored its transmission. In addition, the electrostatic low-energy beam transport system was reengineered to double its heat sinking and equipped with a thermocouple that monitors the temperature of the ground electrode between the two Einzel lenses. The recorded data show that emissions from the source at high voltage dominate the heat load. Emissions from the partly Cs-covered first lens cause the temperature to peak several hours after starting up. On rare occasions, the temperature can also peak due to corona discharges between the center ground electrode and one of the lenses.

H- source↗

Microsecond ramp compression of a metallic liner driven by a 5 MA current on the SPHINX machine using a dynamic load current multiplier pulse shaping

SPHINX is a 6 MA, 1-μs Linear Transformer Driver (LTD) operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. Among the options that are currently being evaluated to improve the generator performances are an upgrade to a 20 MA, 1-μs LTD machine and various power amplification schemes, including a compact Dynamic Load Current Multiplier (DLCM). A method for performing magnetic ramp compression experiments, without modifying the generator operation scheme, was developed using the DLCM to shape the initial current pulse in order to obtain the desired load current profile. In this paper, we discuss the overall configuration that was selected for these experiments, including the choice of a coaxial cylindrical geometry for the load and its return current electrode. We present both 3-D Magneto-hydrodynamic and 1D Lagrangian hydrodynamic simulations which helped guide the design of the experimental configuration. Initial results obtained over a set of experiments on an aluminium cylindrical liner, ramp-compressed to a peak pressure of 23 GPa, are presented and analyzed. Details of the electrical and laser Doppler interferometer setups used to monitor and diagnose the ramp compression experiments are provided. In particular, the configuration used to field both homodyne and heterodyne velocimetry diagnostics in the reduced access available within the liner's interior is described. Current profiles measured at various critical locations across the system, particularly the load current, enabled a comprehensive tracking of the current circulation and demonstrate adequate pulse shaping by the DLCM. The liner inner free surface velocity measurements obtained from the heterodyne velocimeter agree with the hydrocode results obtained using the measured load current as the input. An extensive hydrodynamic analysis is carried out to examine information such as pressure and particle velocity history profiles or magnetic diffusion across the liner. The potential of the technique in terms of applications and achievable ramp pressure levels lies in the prospects for improving the DLCM efficiency through the use of a closing switch (currently under development), reducing the load dimensions and optimizing the diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NUHOMS{sup R} EOS (Extended Optimized Storage): Robust, Advanced, and Dual Purpose Dry Storage System - 16472

AREVA TN has completed the design, analysis, and US NRC license submittal for the NUHOMS{sup R} Extended Optimized Storage (EOS) system. NUHOMS{sup R} EOS offers a large capacity and high heat load dry storage and transportation solution for UNF. EOS is not a new system, but an evolution of the already-proven safe and low-risk horizontal NUHOMS{sup R} storage system, which is one of the most widely used UNF dry storage systems in the United States. The EOS system features a 37PTH dry shielded canister (DSC) for 37 PWR UNF assemblies and an 89BTH DSC for the 89 BWR UNF assemblies. The EOS DSCs will be stored inside a horizontal storage module (HSM) that is a robust, fortress-like concrete storage overpack. Designed with the lessons learned from the Fukushima event in Japan in mind, EOS has robust margins for beyond design basis (BDB) events and offers the lowest risk and highest safety margin of any dry storage system design for recovery from BDB events. EOS also offers innovative aging management features with an aging management program (AMP) to assure safe and low dose long-term storage at the utility sites. EOS incorporates ports for AMP inspections and offers the option of using duplex stainless steel (DSS) for the DSC shell in order to negate corrosion issues. EOS is stored horizontally and above ground, making it easy and quick to access for visual inspection, monitoring, and mitigating actions during AMP. NUHOMS{sup R} EOS is optimized for high capacity, high burnup, high enrichments, and very low cooling times for UNF assemblies. It enables the highest heat load per canister (50 kW) and low dose rates. Even with high heat loads, EOS has significant margins to design basis limits. As the future of used fuel disposition will require the need to move fuel off-site to interim or consolidated storage, EOS is the ideal solution as it enables on-site loading and unloading operations that mitigate risk when transferring fuel on-site or transporting fuel off-site. The EOS design can be safely located in a traditional outdoor setting with fortress-like concrete reinforced modules that offer superior resistance to attack or can be safely operated inside of a building enclosure for those utilities desiring a more discreet siting for its used fuel storage systems. EOS has an innovative basket design that is made of high strength low alloy (HSLA) material and is easy to fabricate due to its non-welded design. Its innovative inlet and outlet air vent design, which incorporates dose reduction hardware, allows for optimal ambient airflow for highly efficient heat transfer with minimal radiation dose. The NUHOMS{sup R} EOS storage modules are interlocked in a side-by-side configuration offering superior and robust seismic performance. The license application for NUHOMS{sup R} EOS is currently under US NRC review and this system will be available for deployment in 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Data-driven Model Reduction for Enhanced Battery Health Monitoring

Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.

Li ion batteries↗

Surface runoff from full-scale coal combustion product pavements during accelerated loading

In this study, the release of metals and metalloids from full-scale portland cement concrete pavements containing coal combustion products (CCPs) was evaluated by laboratory leaching tests and accelerated loading of full-scale pavement sections under well-controlled conditions. An equivalent of 20 years of highway traffic loading was simulated at the OSU/OU Accelerated Pavement Load Facility (APLF). Three types of portland cement concrete driving surface layers were tested, including a control section (i.e., ordinary portland cement (PC) concrete) containing no fly ash and two sections in which fly ash was substituted for a fraction of the cement; i.e., 30% fly ash (FA30) and 50% fly ash (FA50). In general, the concentrations of minor and trace elements were higher in the toxicity characteristic leaching procedure (TCLP) leachates than in the leachates obtained from synthetic precipitation leaching procedure and ASTM leaching procedures. Importantly, none of the leachate concentrations exceeded the TCLP limits or primary drinking water standards. Surface runoff monitoring results showed the highest release rates of inorganic elements from the FA50 concrete pavement, whereas there were little differences in release rates between PC and FA30 concretes. The release of elements generally decreased with increasing pavement loading. Except for Cr, elements were released as particulates (>0.45 {mu} m) rather than dissolved constituents. The incorporation of fly ash in the PC cement concrete pavements examined in this study resulted in little or no deleterious environmental impact from the leaching of inorganic elements over the lifetime of the pavement system.

01 COAL, LIGNITE, AND PEAT↗

Tropospheric Emissions: Monitoring of Pollution (TEMPO)

TEMPO (Tropospheric Emissions: Monitoring of Pollution) was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (approximately 2.1 kilometers N/S by 4.4 kilometers E/W at 36.5 degrees N, 100 degrees W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide),water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the North American component of the global geostationary constellation of pollution monitoring together with the European Sentinel-4 (S4) and Korean Geostationary Environment Monitoring Spectrometer (GEMS) instruments.

tropospheric measurement suite↗

Prognostic health monitoring in switch-mode power supplies with voltage regulation

The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.

Hofmeister, James P↗

Technical Assistance for Remote Sensor Placement Related Projects for Structural Health Monitoring

The world’s infrastructure is aging and many aspects are cost prohibitive to replace or even repair unless critically necessary. The standard way of determining if these repairs are critical or not is usually dependent on trained visual individual inspection. This process is very time consuming and costly considering the large areas and various structures that need to be monitored. A cost effective solution to this problem is to be able to monitor structures, such as roads, buildings, and bridges with remote sensors. Developing this solution provides some unique challenges such as sensor placement, types of sensors, energy needs for placed sensors, and data retrieval. As for the aspect of sensor placement, one method is to fly semi-autonomous Unmanned Arial Vehicles (UAVs) loaded with a sensor deployment mechanism to the structures so as to place the sensor and perhaps retrieve data from previously placed sensors as well. Many tests need to be run to determine the best UAV structure and deployment system to fulfill this task. It is hoped that through a multidisciplinary engineering scope the most effective process of monitoring the aging infrastructure can be developed.

42 ENGINEERING↗

Cell Death, Neuronal Plasticity and Functional Loading in the Development of the Central Nervous System

Research on the precise timing and regulation of neuron production and maturation in the vestibular and visual systems of Wistar rats and several inbred strains of mice (C57B16 and Pallid mutant) concentrated upon establishing a timing baseline for mitotic development of the neurons of the vestibular nuclei and the peripheral vestibular sensory structures (maculae, cristae). This involved studies of the timing and site of neuronal cell birth and preliminary studies of neuronal cell death in both central and peripheral elements of the mammalian vestibular system. Studies on neuronal generation and maturation in the retina were recently added to provide a mechanism for more properly defining the in utero' developmental age of the individual fetal subject and to closely monitor potential transplacental effects of environmentally stressed maternal systems. Information is given on current efforts concentrating upon the (1) perinatal period of development (E18 thru P14) and (2) the role of cell death in response to variation in the functional loading of the vestibular and proprioreceptive systems in developing mammalian organisms.

Keefe, J. R.↗

Uncertainty Quantification Techniques for Sensor Calibration Monitoring in Nuclear Power Plants

This report describes the status of ongoing research towards the development of advanced algorithms for online calibration monitoring. The objective of this research is to develop the next generation of online monitoring technologies for sensor calibration interval extension and signal validation in operating and new reactors. These advances are expected to improve the safety and reliability of current and planned nuclear power systems as a result of higher accuracies and increased reliability of sensors used to monitor key parameters. The focus of this report is on documenting the outcomes of the first phase of R&D under this project, which addressed approaches to uncertainty quantification (UQ) in online monitoring that are data-driven, and can therefore adjust estimates of uncertainty as measurement conditions change. Such data-driven approaches to UQ are necessary to address changing plant conditions, for example, as nuclear power plants experience transients, or as next-generation small modular reactors (SMR) operate in load-following conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

Label-Free Anti-Brownian Trapping of Single Nanoparticles in Solution

Today, biomolecular nanoparticles are prevalent as diagnostic tools and molecular delivery carriers, and it is particularly useful to examine individuals within a sample population to quantify the variations between objects and directly observe the molecular dynamics involving these objects. Using interferometric scattering as a highly sensitive label-free detection scheme, we recently developed the interferometric scattering anti-Brownian electrokinetic (ISABEL) trap to hold a single nanoparticle in solution for extended optical observation. In this perspective, we describe how we implemented this trap, how it extends the capabilities of previous ABEL traps, and how we have begun to study individual carboxysomes, a fascinating biological carbon fixation nanocompartment. By monitoring single nanocompartments for seconds to minutes in the ISABEL trap using simultaneous interferometric scattering and fluorescence spectroscopy, we have demonstrated single-compartment mass measurements, cargo-loading trends, and redox sensing inside individual particles. These experiments benefit from rich multiplexed correlative measurements utilizing both scattering and fluorescence with many exciting future capabilities within reach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stabilizing Effect of High Pore Fluid Pressure on Slip Behaviors of Gouge-bearing Faults

We conducted experiments to investigate the influence of pore fluid pressure on the frictional strength and slip behavior of gouge bearing faults. Saw cut porous sandstone samples with a layer of gouge powders placed between the precut surfaces were deformed in the conventional triaxial loading configuration. A series of velocity-step tests were performed to measure the response of the friction coefficient to variations in sliding velocity. Pore volume changes were monitored during shearing of the gouge. Our results demonstrate that under constant effective pressure, increasing pore pressure stabilizes the frictional slip of faults with all four gouge materials including antigorite, olivine, quartz, and chrysotile. The stabilizing effect is the strongest in antigorite gouge, which shows an evolution of friction parameters from velocity-weakening toward velocity-strengthening behavior with increasing pore pressure. Experiments with controlled pore volume show that the pore volume reduction diminishes under high pore fluid pressures, implying an increasing dilation component at these conditions. The dilatant hardening mechanism can explain the observed strengthening. These results provide a possible explanation to the observed spatial correlation between slow slip events and high pore pressure in many subduction zones.

58 GEOSCIENCES↗

RF Arc Detection in ICRH RDL Antennas by Phase Measurement

A voltage breakdown in an Ion Cyclotron Resonance Heating (ICRH) system is usually detected as an abrupt change in the module of the reflection coefficient |{gamma}in| at the power source output. The same effect can be due to a large load variation. This study is carried out by constructing a electrical model for a Tore Supra ITER-like antenna (TS ILA), and to analyse how a voltage breakdown, localized in any part of the system, modifies several electrical parameters of the circuit (with respect to perfect match conditions), as detected at the location of the monitoring points. The phase difference between the reflections coefficients measured at the output of tuning network when an arc strikes in one of two Resonant double loop (RDL) sections of the ICRH TS ILA appears to be the most promising parameter to detect the arc and identify its position. It is also significantly insensitive to a load variation so an arc and edge localized modes (ELMs) can be distinguished.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of the Reference Bus in Three-Phase State Estimation

As more and more renewable energy sources are being connected to the power grid at lower voltage levels, closer monitoring of distribution networks is becoming a necessity. This is accomplished by state estimation and deployment of Distribution Management Systems (DMS). Distribution feeders are typically untransposed with unbalance loads. Thus, their modeling and analysis show significant differences compared to those for transmission networks. This paper focuses on the state estimation problem and its formulation for unbalanced distribution systems. Specifically, it is concerned about the modeling and solution of three-phase networks without a fully balanced bus to be selected as the angle reference. It is shown that best results will be obtained via the use of a virtual symmetrical bus. Validation of the proposed formulation is carried out by simulations.

Langner, A. L.↗

Foundational Report Series: Advanced Distribution Management Systems for Grid Modernization, DMS Integration of Distributed Energy Resources and Microgrids

Deregulation of the electric utility industry, environmental concerns associated with traditional fossil fuel-based power plants, volatility of electric energy costs, Federal and State regulatory support of “green” energy, and rapid technological developments all support the growth of Distributed Energy Resources (DERs) in electric utility systems and ensure an important role for DERs in the smart grid and other aspects of modern utilities. DERs include distributed generation (DG) systems, such as renewables; controllable loads (also known as demand response); and energy storage systems. This report describes the role of aggregators of DERs in providing optimal services to distribution networks, through DER monitoring and control systems—collectively referred to as a Distributed Energy Resource Management System (DERMS)—and microgrids in various configurations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ambient Atmospheric Hydrocarbon Content as Determined by Gas Chromatographic Techniques from Rural Tidewater Virginia in Late Spring 1974

In an attempt to ascertain the naturally generated hydrocarbon contribution to the air quality of the Hampton Roads region of Tidewater Virginia, a series of 27 air samples was obtained in two rural locations during late spring of 1974. These samples were analyzed for their hydrocarbon content (carbon number range C5 to C10) using gas chromatographic techniques. The thirty different hydrocarbon species were identified and monitored in the experiment. Preliminary analysis of the data indicates an average concentration of 397 parts per billion by weight (carbon) for the total non-methane hydrocarbon loading for C5 to C10 during the experiment. This value exceeds the National Primary Air Quality Standards as set by the Environmental Protection Agency.

Copeland, G. E.↗

Determination of the stiffness reduction of (0,90, + or - N 45) graphite/epoxy laminates under cyclic loading

A series of tests has been performed to determine the effect of fatigue loading on the stiffness degradation of graphite/epoxy composite materials. Specimens were tested in tension-tension fatigue at a loading frequency of 10 Hz and a stress ratio of 0.1, for a wide range of stress levels. During this investigation, both static and dynamic stiffnesses were continually monitored for the range of stress levels tested, and the results are presented in tabular and graphical form.

Jones, D. L.↗