Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Exploring a New Regime of Molecular Orbital Physics in 4⁢d Cluster Magnets with Resonant Inelastic X-Ray Scattering

Molecular orbital systems with clusters of heavy transition metal (TM) ions are one of the most important classes of model materials for studying the interplay between local physics and effects of itinerancy. Despite a large number of candidates identified in the family of 4⁢d TM materials, an understanding of their physics from competing microscopic energy scales is still missing. Here, we bridge this gap by reporting the first resonant inelastic x-ray scattering (RIXS) measurement on a well-known series of Ru cluster magnets with a 6⁢H-perovskite structure Ba 3 ⁢M⁢Ru 2 ⁢O 9 (M 3+ = In 3+ , Y 3+ , La 3+ ) comprised of Ru dimers. In addition to providing a microscopic explanation for their anomalous magnetic properties, our RIXS measurements combined with theoretical modeling uncover a new regime of molecular orbital physics where the combined effect of large hopping and small spin-orbit coupling results in highly fragile electronic states in the Ru-dimer compounds directly manifested as an abrupt change in the RIXS spectrum accompanying a tiny change in the local structure tuned by the M-site ion. This unique combination of energy scales found only in the 4⁢d but not the 5⁢d cluster magnets highlights the value of these materials as a new platform for studying quantum phase transition involving molecular orbitals.

36 MATERIALS SCIENCE↗

MR-Guided High-Intensity Focused Ultrasound: Current Status of an Emerging Technology

The concept of ideal tumor surgery is to remove the neoplastic tissue without damaging adjacent normal structures. High-intensity focused ultrasound (HIFU) was developed in the 1940s as a viable thermal tissue ablation approach. In clinical practice, HIFU has been applied to treat a variety of solid benign and malignant lesions, including pancreas, liver, prostate, and breast carcinomas, soft tissue sarcomas, and uterine fibroids. More recently, magnetic resonance guidance has been applied for treatment monitoring during focused ultrasound procedures (magnetic resonance-guided focused ultrasound, MRgFUS). Intraoperative magnetic resonance imaging provides the best possible tumor extension and dynamic control of energy deposition using real-time magnetic resonance imaging thermometry. We introduce the fundamental principles and clinical indications of the MRgFUS technique; we also report different treatment options and personal outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a topological insulator Dirac cone reshaped by non-magnetic impurity resonance

The massless Dirac electrons found at topological insulator surfaces are thought to be influenced very little by weak, non-magnetic disorder. However, a resonance effect of strongly perturbing non-magnetic impurities has been theoretically predicted to change the dispersion and physical nature of low-energy quasiparticles, resulting in unique particle-like states that lack microscopic translational symmetry. Here we report the direct observation of impurities reshaping the surface Dirac cone of the model three-dimensional topological insulator bismuth selenide. A pronounced kink-like dispersion feature is observed in disorder-enriched samples, and found to be closely associated with the anomaly caused by impurity resonance in the surface state density of states, as observed by dichroic angle-resolved photoemission spectroscopy. The experimental observation of these features, which closely resemble theoretical predictions, has significant implications for the properties of topological Dirac cones in applied scenarios that commonly feature point-defect disorder at surfaces or interfaces. Topological insulators - influence of surface impurities: The electronic properties of topological insulators are robust against perturbations, including the presence of non-magnetic impurities. However, surface impurities can give rise to resonant states near the Dirac point, and if their density becomes sufficiently high it is predicted that they can substantially modify the dispersion of the Dirac cone and develop a collective behaviour that results in the formation of particle-like states that lack microscopic translational symmetry. L. Andrew Wray at Purdue University and at the New York University Shanghai, and colleagues, used angle-resolved photoemission spectroscopy to experimentally observe the reshaping of the surface Dirac cone in a defect-rich sample of the topological insulator Bi 2 Se 3 . These results indicate that surface impurities can provide a useful handle to control the properties of topological insulators.

36 MATERIALS SCIENCE↗

Ferromagnetic resonance and magnetic properties of ALHA 81005

Seven chips of primarily matrix material from the Antarctic meteorite ALHA 81005 were analyzed by ferromagnetic resonance (FMR) and magnetic hysteresis techniques. The FMR spectra of two chips have a resonance at g of about 2.1 that resembles the g of about 2.1 resonance that is characteristic of lunar soils. Thus the FMR spectra are consistent with the lunar regolith being a progenitor for the matrix material. For the two chips, the FMR surface exposure (maturity) index was about 5 units, which is equivalent to a value for an immature lunar soil. The total concentration of metallic iron is on the order of 0.11 equivalent wt. pct, which is within the observed range for Apollo 16 rocks and soils.

Morris, R. V.↗

A system to detect cerebral aneurysms in multimodality angiographic data sets

Purpose: The early detection of cerebral aneurysms plays a major role in preventing subarachnoid hemorrhage. The authors present a system to automatically detect cerebral aneurysms in multimodal 3D angiographic data sets. The authors’ system is parametrizable for contrast-enhanced magnetic resonance angiography (CE-MRA), time-of-flight magnetic resonance angiography (TOF-MRA), and computed tomography angiography (CTA). Methods: Initial volumes of interest are found by applying a multiscale sphere-enhancing filter. Several features are combined in a linear discriminant function (LDF) to distinguish between true aneurysms and false positives. The features include shape information, spatial information, and probability information. The LDF can either be parametrized by domain experts or automatically by training. Vessel segmentation is avoided as it could heavily influence the detection algorithm. Results: The authors tested their method with 151 clinical angiographic data sets containing 112 aneurysms. The authors reach a sensitivity of 95% with CE-MRA data sets at an average false positive rate per data set (FP{sub DS}) of 8.2. For TOF-MRA, we achieve 95% sensitivity at 11.3 FP{sub DS}. For CTA, we reach a sensitivity of 95% at 22.8 FP{sub DS}. For all modalities, the expert parametrization led to similar or better results than the trained parametrization eliminating the need for training. 93% of aneurysms that were smaller than 5 mm were found. The authors also showed that their algorithm is capable of detecting aneurysms that were previously overlooked by radiologists. Conclusions: The authors present an automatic system to detect cerebral aneurysms in multimodal angiographic data sets. The system proved as a suitable computer-aided detection tool to help radiologists find cerebral aneurysms.

60 APPLIED LIFE SCIENCES↗

Inter- and Intrafractional Tumor and Organ Movement in Patients With Cervical Cancer Undergoing Radiotherapy: A Cinematic-MRI Point-of-Interest Study

Purpose: Internal tumor and organ movement is important when considering intensity-modulated radiotherapy for patients with cancer of the cervix because of the tight margins and steep dose gradients. In this study, the internal movement of the tumor, cervix, and uterus were examined using serial cinematic magnetic resonance imaging scans and point-of-interest analysis. Methods and Materials: Twenty patients with Stage IB-IVA cervical cancer underwent pelvic magnetic resonance imaging before treatment and then weekly during external beam radiotherapy. In each 30-min session, sequential T{sub 2}-sagittal magnetic resonance imaging scans were obtained. The points of interest (cervical os, uterine canal, and uterine fundus) were traced on each image frame, allowing the craniocaudal and anteroposterior displacements to be measured. The mean displacements and trends were analyzed using mixed linear models. Prediction intervals were calculated to determine the internal target margins. Results: Large interscan motion was found for all three points of interest that was only partially explained by the variations in bladder and rectal filling. The intrascan motion was much smaller. Both inter- and intrascan motion was greatest at the fundus of the uterus, less along the canal, and least at the cervical os. The isotropic internal target margins required to encompass 90% of the interscan motion were 4 cm at the fundus and 1.5 cm at the os. In contrast, smaller margins of 1 cm and 0.45 cm, respectively, were adequate to encompass the intrascan motion alone. Conclusion: Daily soft-tissue imaging with correction for interfractional motion or adaptive replanning will be important if the benefits of intensity-modulated radiotherapy are to be maximized in women with cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deblurring

In most instances, traditional EEG methodology provides insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. This article describes a method called Deblurring for increasing the spatial detail of the EEG and for fusing neurophysiologic and neuroanatomic data. Deblurring estimates potentials near the outer convexity of the cortex using a realistic finite element model of the structure of a subject's head determined from their magnetic resonance images. Deblurring is not a source localization technique and thus makes no assumptions about the number or type of generator sources. The validity of Deblurring has been initially tested by comparing deblurred data with potentials measured with subdural grid recordings. Results suggest that deblurred topographic maps, registered with a subject's magnetic resonance imaging and rendered in three dimensions, provide better spatial detail than has heretofore been obtained with scalp EEG recordings. Example results are presented from research studies of somatosensory stimulation, movement, language, attention and working memory. Deblurred ictal EEG data are also presented, indicating that this technique may have future clinical application as an aid to seizure localization and surgical planning.

Non-NASA Center↗

Postpartum Hemorrhage Treated with Gelfoam Slurry Embolization Using the Superselective Technique: Immediate Results and 1-Month MRI Follow-up

To evaluate the efficacy and safety of superselective embolization of the uterine arteries in a postpartum hemorrhage. Between November 2004 and January 2011, a total of 44 consecutive women (median {+-} standard deviation age 34 {+-} 3 years, range 23-41 years) were referred to our institution for postpartum intractable hemorrhage management. All patients were embolized with a microcatheter that was placed deep into the uterine arteries upstream of the cervical arteries. The embolic agent was a mixture of contrast medium and 5 Multiplication-Sign 5 Multiplication-Sign 5 cm pieces of gelfoam (Gelita-Spon) modified into a gelatin emulsion as follows: rapid mixing through a three-way stopcock with two 2.5-ml syringes. A 1-ml syringe was used for injection. One month after embolization, all patients underwent magnetic resonance imaging and clinical examination. Technical and clinical success was obtained in all cases. Thirty-five patients experienced bleeding related to poor retraction of the uterus, 7 patients because of a tear of the cervix and 2 because of a vaginal hematoma. Pre- and postembolization red blood cell transfusions were (mean {+-} standard deviation [SD]) 6 {+-} 1.2 (range 3-8) U and 2 {+-} 0.7 (range 2-4) U, respectively. One-month magnetic resonance imaging follow-up revealed no sign of ischemic myometrium or necrosis, and no instances of uterine rupture and no pelvic vein thrombosis. Incidental findings included two small intramyometrial hematic collections. All uterine arteries were patent via magnetic resonance angiography. Seventeen patients had concomitant fibroids, all of which appeared hypovascular. This technique permits good, safe clinical results with no marked damage to the uterine arteries or the uterus itself.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-resonator double-negative metamaterial

Resonances can be tuned in dielectric resonators in order to construct single-resonator, negative-index metamaterials. For example, high-contrast inclusions in the form of metallic dipoles can be used to shift the first electric resonance down (in frequency) to the first magnetic resonance, or alternatively, air splits can be used to shift the first magnetic resonance up (in frequency) near the first electric resonance. Degenerate dielectric designs become especially useful in infrared- or visible-frequency applications where the resonator sizes associated with the lack of high-permittivity materials can become of sufficient size to enable propagation of higher-order lattice modes in the resulting medium.

36 MATERIALS SCIENCE↗

Manipulation of quantum dot emission with semiconductor metasurfaces exhibiting magnetic quadrupole resonances

Optical metasurfaces were suggested as a route for engineering advanced light sources with tailored emission properties. In particular, they provide a control over the emission directionality, which is essential for single-photon sources and LED applications. Here, we experimentally study light emission from a metasurface composed of III-V semiconductor Mie-resonant nanocylinders with integrated quantum dots (QDs). Specifically, we focus on the manipulation of the directionality of spontaneous emission from the QDs due to excitation of different magnetic quadrupole resonances in the nanocylinders. To this end, we perform both back focal plane imaging and momentum-resolved spectroscopy measurements of the emission. This allows for a comprehensive analysis of the effect of the different resonant nanocylinder modes on the emission characteristics of the metasurface. Our results show that the emission directionality can be manipulated by an interplay of the excited quadrupolar nanocylinder modes with the metasurface lattice modes and provide important insights for the design of novel smart light sources and new display concepts.

Vaskin, Aleksandr↗

Microstructure from joint analysis of experimental data and ab initio interactions: Hydrogenated amorphous silicon

A study of the formation of voids and molecular hydrogen in hydrogenated amorphous silicon is presented based upon a hybrid approach that involves inversion of experimental nuclear magnetic resonance data in conjunction with ab initio total-energy relaxations in an augmented solution space. The novelty of this approach is that the voids and molecular hydrogen appear naturally in the model networks unlike conventional approaches, where voids are created artificially by removing silicon atoms from the networks. Two representative models with 16 and 18 at. % of hydrogen are studied in this work. The result shows that the microstructure of the a-Si:H network consists of several microvoids and few molecular hydrogen for concentration above 15 at. % H. The microvoids are highly irregular in shape and size, and have a linear dimension of 5–7 Å. The internal surface of a microvoid is found to be decorated with 4–9 hydrogen atoms in the form of monohydride Si–H configurations as observed in nuclear magnetic resonance experiments. The microstructure consists of (0.9–1.4)% hydrogen molecules of total hydrogen in the networks. These observations are consistent with the outcome of infrared spectroscopy, nuclear magnetic resonance, and calorimetry experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Taming harmful bursts and heat flux in high-confinement tokamak plasmas

A major challenge in tokamak fusion research is first-wall erosion caused by steady heat loads and sudden energy bursts known as edge-localized modes. Divertor detachment reduces steady-state heat flux, while resonant magnetic perturbations can suppress these instabilities. However, integrating the two has been difficult because they require conflicting operating conditions. Here we demonstrate simultaneous achievement of resonant magnetic perturbations mitigated small edge-localized modes and impurity seeded partial divertor detachment in plasmas with an ITER-similar shape on the DIII-D tokamak. Experiments and simulations show that resonant magnetic perturbations facilitate detachment by redistributing particles, lowering the core density and increasing the scrape-off layer density, thereby reducing the amount of injected gas required. Cooling-gas injection eliminates the secondary heat-flux peak created by three-dimensional magnetic lobes, while edge cooling weakens the plasma response to the applied magnetic fields. These advances illustrate a viable pathway for integrating edge stability control with power exhaust in future fusion reactors.

magnetically confined plasmas↗

Low-noise pulsed pre-polarization magnet system for ultra-low field NMR

A liquid cooled, pulsed electromagnet of solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system has been designed, fabricated and successfully operated. The magnet design minimizes Johnson noise, minimizes the hydrogen signal and incorporates minimal metal and no ferromagnetic materials. In addition, an acoustically quiet cooling system permitting 50% duty cycle operation was achieved by designing for single-phase, laminar flow, forced convection cooling. Winding, conductor splicing and epoxy impregnation techniques were successfully developed to produce a coil winding body with integral cooling passageways and adequate structural integrity. Issues of material compatibility, housing, coolant flow system and heat rejection system design will be discussed. Additionally, this pulsed electromagnet design has been extended to produce a boiling liquid cooled version in a paired solenoid configuration suitable for duty in an ultra-low field nuclear magnetic resonance system. This pair of liquid nitrogen cooled coils is currently being tested and commissioned. Issues of material compatibility, thermal insulation, thermal contraction, housing and coolant flow design are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discriminative analysis of schizophrenia patients using graph convolutional networks: A combined multimodal MRI and connectomics analysis

Introduction Recent studies in human brain connectomics with multimodal magnetic resonance imaging (MRI) data have widely reported abnormalities in brain structure, function and connectivity associated with schizophrenia (SZ). However, most previous discriminative studies of SZ patients were based on MRI features of brain regions, ignoring the complex relationships within brain networks. Methods We applied a graph convolutional network (GCN) to discriminating SZ patients using the features of brain region and connectivity derived from a combined multimodal MRI and connectomics analysis. Structural magnetic resonance imaging (sMRI) and resting-state functional magnetic resonance imaging (rs-fMRI) data were acquired from 140 SZ patients and 205 normal controls. Eighteen types of brain graphs were constructed for each subject using 3 types of node features, 3 types of edge features, and 2 brain atlases. We investigated the performance of 18 brain graphs and used the TopK pooling layers to highlight salient brain regions (nodes in the graph). Results The GCN model, which used functional connectivity as edge features and multimodal features (sMRI + fMRI) of brain regions as node features, obtained the highest average accuracy of 95.8%, and outperformed other existing classification studies in SZ patients. In the explainability analysis, we reported that the top 10 salient brain regions, predominantly distributed in the prefrontal and occipital cortices, were mainly involved in the systems of emotion and visual processing. Discussion Our findings demonstrated that GCN with a combined multimodal MRI and connectomics analysis can effectively improve the classification of SZ at an individual level, indicating a promising direction for the diagnosis of SZ patients. The code is available at https://github.com/CXY-scut/GCN-SZ.git .

Chen, Xiaoyi↗

Noninvasive analysis of human neck muscle function

STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.

NASA Program Space Physiology and Countermeasures↗

Metastability And Crystal Structure of The Bialkali Complex Metal Hydride NaK(BH4)2

A new bialkali borohydride, NaK(BH{sub 4}){sub 2}, was synthesized by mechanical milling of NaBH4 and KBH4 in a 1:1 ratio. The synthesis was conducted based on a prediction from a computational screening of hydrogen storage materials suggesting the potential stability of NaK(BH{sub 4}){sub 2}. The new phase was characterized using X-ray diffraction, Raman scattering and magic angle spinning (MAS) nuclear magnetic resonance (NMR). The Raman measurements indicated B-H vibrations of the (BH{sub 4}){sup -} anion, while magnetic resonance chemical shifts in {sup 23}Na, and {sup 39}K MAS NMR spectra showed new chemical environments for Na and K resulting from the formation of the new bialkali phase. X-ray diffraction spectra indicated a new crystal structure with rhombohedral symmetry, most likely in the space group R3, distinct from the starting materials NaBH{sub 4}, and KBH{sub 4}. Although in-situ XRD measurements indicated the material to be metastable, decomposing to the starting materials NaBH{sub 4} and KBH{sub 4}, the successful synthesis of NaK(BH{sub 4}){sub 2} demonstrates the ability of computational screening to predict candidates for hydrogen storage materials.

08 HYDROGEN↗

MRI- Versus CT-Based Volume Delineation of Lumpectomy Cavity in Supine Position in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine magnetic resonance imaging (MRI) and computed tomography (CT) for lumpectomy cavity (LC) volume delineation in supine radiotherapy treatment position and to assess the interobserver variability. Methods and Materials: A total of 15 breast cancer patients underwent a planning CT and directly afterward MRI in supine radiotherapy treatment position. Then, 4 observers (2 radiation oncologists and 2 radiologists) delineated the LC on the CT and MRI scans and assessed the cavity visualization score (CVS). The CVS, LC volume, conformity index (CI), mean shift of the center of mass (COM), with the standard deviation, were quantified for both CT and MRI. Results: The CVS showed that MRI and CT provide about equal optimal visibility of the LC. If the CVS was high, magnetic resonance imaging provided more detail of the interfaces of the LC seroma with the unaffected GBT. MRI also pictured in more detail the interfaces of axillary seromas (if present) with their surroundings and their relationship to the LC. Three observers delineated smaller, and one observer larger, LC volumes comparing the MRI- and CT-derived delineations. The mean {+-} standard deviation CI was 32% {+-} 25% for MRI and 52% {+-} 21% for CT. The mean {+-} standard deviation COM shift was 11 {+-} 10 mm (range 1-36) for MRI and 4 {+-} 3 mm (range 1-10) for CT. Conclusions: MRI does not add additional information to CT in cases in which the CVS is assessed as low. The conformity (CI) is lower for MRI than for CT, especially at a low CVS owing to greater COM shifts for MRI, probably caused by inadequate visibility of the surgical clips on magnetic resonance (MR) images. The COM shifts seriously dictate a decline in the CI more than the variability of the LC volumes does. In cases in which MRI provides additional information, MRI must be combined with the CT/surgical clip data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗