An Optimal Guarding Scheme for Thermal Conductivit
In measuring thermal conductivity using the guarde
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
In measuring thermal conductivity using the guarde
The energy and flux of the argon ions produced in Sahand plasma focus have been measured by employing a well-designed Faraday cup. The secondary electron emission effects on the ion signals are simulated and the dimensions of Faraday cup are optimized to minimize these effects. The measured ion energy spectrum is corrected for the ion energy loss and charge exchange in the background gas. The effects of the capacitor bank voltage and working gas pressure on the ion energy spectrum are also investigated. It has been shown that the emitted ion number per energy increases as the capacitor bank voltage increases. Decreasing the working gas pressure leads to the increase in the number of emitted ion per energy.
Aircraft performance can be optimized at the flight condition by using available redundancy among actuators. Effective use of this potential allows improved performance beyond limits imposed by design compromises. Optimization based on nominal models does not result in the best performance of the actual aircraft at the actual flight condition. An adaptive algorithm for optimizing performance parameters, such as speed or fuel flow, in flight based exclusively on flight data is proposed. The algorithm is inherently insensitive to model inaccuracies and measurement noise and biases and can optimize several decision variables at the same time. An adaptive constraint controller integrated into the algorithm regulates the optimization constraints, such as altitude or speed, without requiring and prior knowledge of the autopilot design. The algorithm has a modular structure which allows easy incorporation (or removal) of optimization constraints or decision variables to the optimization problem. An important part of the contribution is the development of analytical tools enabling convergence analysis of the algorithm and the establishment of simple design rules. The fuel-flow minimization and velocity maximization modes of the algorithm are demonstrated on the NASA Dryden B-720 nonlinear flight simulator for the single- and multi-effector optimization cases.
Here, this paper investigates solution strategies for nonlinear problems in Hilbert spaces, such as nonlinear partial differential equations (PDEs) in Sobolev spaces, when only finite measurements are available. We formulate this as a nonlinear optimal recovery problem, establishing its well-posedness and proving its convergence to the true solution as the number of measurements increases. However, the resulting formulation might not have a finite-dimensional solution in general. We thus present a sufficient condition for the finite dimensionality of the solution, applicable to problems with well-defined point evaluation measurements. To address the broader setting, we introduce a relaxed nonlinear optimal recovery and provide a detailed convergence analysis. An illustrative example is given to demonstrate that our formulations and theoretical findings offer a comprehensive framework for solving nonlinear problems in infinite-dimensional spaces with limited data.
We review the singular value decomposition (SVD) framework and use it for quantifying and discerning vertical information in greenhouse gas retrievals from column integrated absorption measurements. While the commonly used traditional Bayesian optimal estimation (OE) assumes a prior distribution in order to regularize the inversion problem, the SVD approach identifies principal components that can be retrieved from the measurement without explicitly specifying a prior mean and prior covariance matrix. We review the SVD method, explicitly recognize the use of an uninformative prior and show it to incur no bias from the choice of the prior. We also make the connection between the SVD method and the pseudo-inverse, which makes it more intuitive and easy to understand. We illustrate the use of the SVD method on an integrated path differential absorption CO2 lidar measurement model and verify our derivations and bias-free properties versus optimal estimation using numerical simulations. In contrast, traditional OE retrievals exhibit bias when the prior mean used in the retrieval differs from the true mean. Hence, the SVD method is particularly useful for situations in which knowledge of the prior mean and prior covariance of the true state (e.g., greenhouse gas profiles) is inadequate.
The Multiphysics Object Oriented Simulation Environment (MOOSE) framework has been developed to solve a variety of complex simulations ranging from groundwater flows to full reactor simulations. MOOSE excels at solving fully-implicit, fully-coupled, highly nonlinear models using the Jacobian Free Newton-Krylov (JFNK) method relying on years of expertise in several dependent packages including PETSc, libMesh, Hypre and many others. The modular design of MOOSE enables the rapid development of new physics models that can be coupled with relative ease within the framework for building up simulations of different levels of complexity. With the ongoing adoption of MOOSE to new application areas along with streamlining of existing simulations, the priorities must be adjusted to include code optimizations. This includes both execution speed and the memory footprint of MOOSE-based simulations. These two categories can be further broken down into ''micro-optimizations'' or source code optimizations and algorithmic optimizations where source code is restructured to accomplish the same tasks through a more efficient means. However, before any code optimizations can occur, one must have robust way of measuring these critical simulation properties to identify the best candidates for optimizations along with having a way to identify the effectiveness of proposed optimizations to the framework. This report discusses the preliminary work towards the implementation of a robust execution baseline of the framework and derivative applications under a variety of different simulations. In addition, several potential optimization target areas in both the MOOSE framework and dependent libraries have been identified. An implementation strategy and potential benefits are discussed.
This case study describes how Target developed an optimized, re-engineered process that integrates several energy-efficiency measures such as reduced lighting loads, improved roof insulation, optimized ventilation, and more accurate load calculations through its rooftop unit (RTU) replacement program. Target's approach achieved ongoing energy reduction, operations and maintenance reduction, and improved heating, ventilating, and air-conditioning (HVAC) performance by reducing equipment cycling.
We describe an optical pump/probe system for sensitive measurements of time-resolved optical measurements of material dynamics. The instrument design is optimized for time-resolved magneto-optic Kerr effect (TR-MOKE) measurements of dynamics in magnetic materials. The system also allows for time-domain thermoreflectance (TDTR) measurements of thermal transport properties and picosecond acoustic measurements of film thickness and/or elastic constants. The system has several advantages over the conventional designs for TRMOKE and/or TDTR systems. Measurements of pump-induced changes to the probe beam intensity are shot-noise limited. The system’s design allows for MOKE and/or thermoreflectance measurements of both sides of a sample. Pumping and probing the sample on opposite sides allows nanoscale flash diffusivity measurements of transport properties. The wavelengths of the pump and probe beams are straightforward to tune between 350–525 nm and 690–1050 nm. A tunable wavelength allows for optical resonances in a wide array of materials to be excited and/or probed. Finally, the setup is calibrated to allow for the real and imaginary components of Kerr signals to be separately quantified.
Overall aerodynamic design information is given for all five stages of an axial flow core compressor (74A) having a 9.271 pressure ratio and 29.710 kg/sec flow. For the inlet stage group (first three stages), detailed blade element design information and experimental overall performance are given. At rotor 1 inlet tip speed was 430.291 m/sec, and hub to tip radius ratio was 0.488. A low number of blades per row was achieved by the use of low-aspect-ratio blading of moderate solidity. The high reaction stages have about equal energy addition. Radial energy varied to give constant total pressure at the rotor exit. The blade element profile and shock losses and the incidence and deviation angles were based on relevant experimental data. Blade shapes are mostly double circular arc. Analysis by a three-dimensional Euler code verified the experimentally measured high flow at design speed and IGV-stator setting angles. An optimization code gave an optimal IGV-stator reset schedule for higher measured efficiency at all speeds.
A light source is described for the efficient generation of 1.54-micron for eye-safe aerosol lidar operation. The system is based upon an Nd:YAG laser at 1.06 micron which is then Raman-shifted in methane to produce light at the first Stokes wavelength of 1.54 micron. First Stokes light generated in the backward direction was retroreflected back into the Raman cell for amplification in the tail of the 10 ns pump beam. The energy conversion efficiency and the spatial beam quality of the amplified first Stokes were found to be adversely affected when operated at higher repetition rates due to a thermal gradient produced in the generation region. A Stokes energy of 25 mJ was obtained for a pumping energy of 140 mJ at a repetition rate of 10 Hz. The beam divergence of the amplified Stokes radiation was measured to be less than 1 mrad. The optimized results demonstrate the applicability of this radiation for eye-safe lidar measurements.
The objective of this research is to evaluate the performance of the advanced distribution management system (ADMS) Volt/VAR Optimization (VVO) application for different levels of model quality and different levels of measurement density -- using 4 different load days VVO optimized for conservative voltage regulation (CVR) and six feeders from Xcel Energy.
Cross-correlations of galaxy positions and galaxy shears with maps of gravitational lensing of the cosmic microwave background (CMB) are sensitive to the distribution of large-scale structure in the Universe. Such cross-correlations are also expected to be immune to some of the systematic effects that complicate correlation measurements internal to galaxy surveys. We present measurements and modeling of the cross-correlations between galaxy positions and galaxy lensing measured in the first three years of data from the Dark Energy Survey with CMB lensing maps derived from a combination of data from the 2500 deg 2 SPT-SZ survey conducted with the South Pole Telescope and full-sky data from the Planck satellite. The CMB lensing maps used in this analysis have been constructed in a way that minimizes biases from the thermal Sunyaev Zel’dovich effect, making them well suited for cross-correlation studies. The total signal-to-noise of the cross-correlation measurements is 23.9 (25.7) when using a choice of angular scales optimized for a linear (nonlinear) galaxy bias model. Here we use the cross-correlation measurements to obtain constraints on cosmological parameters. For our fiducial galaxy sample, which consist of four bins of magnitude-selected galaxies, we find constraints of Ω m =0.272$^{+0.032}_{-0.052}$ and S 8 ≡σ8$\sqrt{Ω_m/0.3}$=0.736$^{+0.032}_{-0.028}$ (Ω m =0.245$^{+0.026}_{-0.044}$ and S 8 =0.734$^{+0.035}_{-0.028}$) when assuming linear (nonlinear) galaxy bias in our modeling. Considering only the cross-correlation of galaxy shear with CMB lensing, we find Ω m =0.270$^{+0.043}_{-0.061}$ and S 8 =0.740$^{+0.034}_{-0.029}$. Our constraints on S8 are consistent with recent cosmic shear measurements, but lower than the values preferred by primary CMB measurements from Planck.
Two modern machine learning techniques, Linear Programming Boosting (LPBoost) and Support Vector Machines (SVMs), are introduced and applied to a geochemical dataset of niobium-tantalum ('coltan') ores from Central Africa to demonstrate how such information may be used to distinguish ore provenance, i.e., place of origin. The compositional data used include uni- and multivariate outliers and elemental distributions are not described by parametric frequency distribution functions. The 'soft margin' techniques of LPBoost and SVMs can be applied to such data. Optimization of their learning parameters results in an average accuracy of up to c. 92%, if spot measurements are assessed to estimate the provenance of ore samples originating from two geographically defined source areas. A parameterized performance measure, together with common methods for its optimization, was evaluated to account for the presence of uneven datasets. Optimization of the classification function threshold improves the performance, as class importance is shifted towards one of those classes. For this dataset, the average performance of the SVMs is significantly better compared to that of LPBoost.
Purpose: To evaluate the performance of a model based image reconstruction method in reducing metal artifacts in the megavoltage computed tomography (MVCT) images of a phantom representing bilateral hip prostheses and to compare with the filtered-backprojection (FBP) technique. Methods: An iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with an additional model for the pair/triplet production process and the energy dependent response of the detectors. The beam spectra for an in-house bench-top and TomoTherapy Trade-Mark-Sign MVCTs are modeled for use in IMPACT. The empirical energy dependent response of detectors is calculated using a constrained optimization technique that predicts the measured attenuation of the beam by various thicknesses (0-24 cm) of solid water slabs. A cylindrical (19.1 cm diameter) plexiglass phantom containing various cylindrical inserts of relative electron densities 0.295-1.695 positioned between two steel rods (2.7 cm diameter) is scanned in the bench-top MVCT that utilizes the bremsstrahlung radiation from a 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C and in the imaging beam of the TomoTherapy Trade-Mark-Sign MVCT. The FBP technique in bench-top MVCT reconstructs images from raw signal normalized to air scan and corrected for beam hardening using a uniform plexiglass cylinder (20 cm diameter). The IMPACT starts with a FBP reconstructed seed image and reconstructs the final image in 150 iterations. Results: In both MVCTs, FBP produces visible dark shading in the image connecting the steel rods. In the IMPACT reconstructed images this shading is nearly removed and the uniform background is restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding values in the absence of the steel inserts. In the FBP images of the bench-top MVCT, the shading causes 4%-9.5% underestimation of electron density at the central inserts with an average of (6.3 {+-} 1.8)% for the range of electron densities studied. In the uniform plexiglass background, the shadow creates 0.8%-4.7% underestimation of electron density with an average of (2.9 {+-} 1.2)%. In the corresponding IMPACT images, the underestimation in the shaded plexiglass background is 0.3%-1.8% with an average of (0.9 {+-} 0.5)% and 1.4%-6.8% with an average of (2.8 {+-} 2.7)% in the central insert region. In the FBP images of the TomoTherapy Trade-Mark-Sign MVCT, this shading creates 2.6%-6.7% underestimation of electron density with an average of (3.7 {+-} 1.4)% at the central inserts and 5.9%-7.2% underestimation in the background with an average of (6.4 {+-} 0.5)%. In the IMPACT images, the uniform background between the steel rods is restored with 0.3%-1.0% underestimation of electron density with an average of (0.7 {+-} 0.3)%. The corresponding underestimation at the central inserts of the IMPACT images is -0.4%-0.1% with an average of (-0.1 {+-} 0.2)%. Conclusions: The shading metal artifact has been nearly removed in MVCT images using the IMPACT algorithm with the accurate geometry of the system, proper modeling of energy dependent response of detectors, and all relevant photon interaction processes. This results less than 1% difference in electron density in the background plexiglass and less than 3% averaged over the range of electron densities investigated.
Source localization, such as detecting a nuclear source in an urban area or ascertaining the origin of a chemical plume, is generally regarded as a well-documented inverse problem; however, optimally placing sensors to collect data for such problems is a more challenging task. In particular, optimal sensor placement—that is, measurement locations resulting in the least uncertainty in the estimated source parameters—depends on the location of the source, which is typically unknown a priori. Mobile sensors are advantageous because they have the flexibility to adapt to any given source position. While most mobile sensor strategies designate a trajectory for sensor movement, we instead employ mutual information, based on Shannon entropy, to choose the next measurement location from a discrete set of design conditions.
The purpose of this study was to investigate the radiation doses to the lower extremities in interventional radiology suites and evaluate the benefit of installation of protective lead shielding. After an alarmingly increased dose to the lower extremity in a preliminary study, nine interventional radiologists wore thermoluminescent dosimeters (TLDs) just above the ankle, over a 4-week period. Two different interventional suites were used with Siemens undercouch fluoroscopy systems. A range of procedures was carried out including angiography, embolization, venous access, drainages, and biopsies. A second identical 4-week study was then performed after the installation of a 0.25-mm lead curtain on the working side of each interventional table. Equivalent doses for all nine radiologists were calculated. One radiologist exceeded the monthly dose limit for a Category B worker (12.5 mSv) for both lower extremities before lead shield placement but not afterward. The averages of both lower extremities showed a statistically significant dose reduction of 64% (p < 0.004) after shield placement. The left lower extremity received a higher dose than the right, 6.49 vs. 4.57 mSv, an increase by a factor of 1.42. Interventional radiology is here to stay but the benefits of interventional radiology should never distract us from the important issue of radiation protection. All possible measures should be taken to optimize working conditions for staff. This study showed a significant lower limb extremity dose reduction with the use of a protective lead curtain. This curtain should be used routinely on all C-arm interventional radiologic equipment.
We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.
The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.