Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Lifetime measurement of the 6792 keV state in {sup 15}O, important for the astrophysical S factor extrapolation in {sup 14}N(p,{gamma}){sup 15}O

We report on a new lifetime measurement of the E{sub x}=6792 keV state in {sup 15}O via the Doppler-shift attenuation method at the E=259 keV resonance in the reaction {sup 14}N(p,{gamma}){sup 15}O. This subthreshold state is of particular importance for the determination of the ground state astrophysical S factor of {sup 14}N(p,{gamma}){sup 15}O at stellar energies. The measurement technique has been significantly improved over that used in previous work. The conclusion of a finite lifetime drawn there cannot be confirmed with the present data. In addition, the lifetimes of the two states at E{sub x}=5181 and 6172 keV have been measured with the same technique in order to verify the experimental method. We observe an attenuation factor F({tau})>0.98 for the E{sub x}=6172 and 6792 keV states, respectively, corresponding to {tau}<0.77 fs. The attenuation factor for the E{sub x}=5181 keV state results in F({tau})=0.78{+-}0.02 corresponding to {tau}=8.4{+-}1.0 fs, which is in excellent agreement with literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ensemble-Averaging Resolves Rapid Atmospheric Response to the 2017 Total Solar Eclipse [Rapid Resolution of the Atmospheric Response to the 2017 Total Solar Eclipse]

Rapid changes in solar radiative forcing influence heat, scalar and momentum fluxes and thereby shift the trajectory of near-surface atmospheric transitions. Surface fluxes are difficult to obtain during atmospheric transitions by either bulk or eddy-covariance methods because both techniques assume quasi-stationarity in an atmospheric state and require sufficiently long blocks of data, typically on the order of 10–30 min, to obtain statistically significant results. These computational requirements limit the temporal resolution of atmospheric processes that researchers can examine using traditional measurement techniques. In this paper, we present a novel observational approach to calculate surface fluxes at sub-minute temporal resolutions.

54 ENVIRONMENTAL SCIENCES↗

New experimental techniques for solar cells

Solar cell capacitance has special importance for an array controlled by shunting. Experimental measurements of solar cell capacitance in the past have shown disagreements of orders of magnitude. Correct measurement technique depends on maintaining the excitation voltage less than the thermal voltage. Two different experimental methods are shown to match theory well, and two effective capacitances are defined for quantifying the effect of the solar cell capacitance on the shunting system.

Lenk, R.↗

Future requirements and roles of computers in aerodynamics

While faster computers will be needed to make solution of the Navier-Stokes equations practical and useful, most all of the other aerodynamic solution techniques can benefit from faster computers. There is a wide variety of computational and measurement techniques, the prospect of more powerful computers permits extension and an enhancement across all aerodynamic methods, including wind-tunnel measurement. It is expected that, as in the past, a blend of methods will be used to predict aircraft aerodynamics in the future. These will include methods based on solution of the Navier-Stokes equations and the potential flow equations as well as those based on empirical and measured results. The primary flows of interest in aircraft aerodynamics are identified, the predictive methods currently in use and/or under development are reviewed and two of these methods are analyzed in terms of the computational resources needed to improve their usefulness and practicality.

Gregory, T. J.↗

The investigation of advanced remote sensing techniques for the measurement of aerosol characteristics

Advanced remote sensing techniques and inversion methods for the measurement of characteristics of aerosol and gaseous species in the atmosphere were investigated. Of particular interest were the physical and chemical properties of aerosols, such as their size distribution, number concentration, and complex refractive index, and the vertical distribution of these properties on a local as well as global scale. Remote sensing techniques for monitoring of tropospheric aerosols were developed as well as satellite monitoring of upper tropospheric and stratospheric aerosols. Computer programs were developed for solving multiple scattering and radiative transfer problems, as well as inversion/retrieval problems. A necessary aspect of these efforts was to develop models of aerosol properties.

Deepak, A.↗

Tests of timing properties of silicon photomultipliers

Timing measurements of Silicon Photomultipliers (SiPM) [1] and [2] at the picosecond level were performed at Fermilab. The core timing resolution of the electronic measurement technique is approximately 2 ps. The single photoelectron time resolution (SPTR) was measured for the signals coming from the SiPM's. A SPTR of about one hundred picoseconds was obtained for SiPM's illuminated by laser pulses. The dependence of the SPTR on applied bias voltage and on the wavelength of the light was measured. A simple model is proposed to explain the difference in the SPTR for blue and red light. A time of flight system based on the SiPM's, with quartz Cherenkov radiators, was tested in a proton beam at Fermilab. The time resolution obtained is 35 ps per SiPM. Finally, requirements for the SiPM's temperature and bias voltage stability to maintain the time resolution are discussed.

43 PARTICLE ACCELERATORS↗

Time-of-Flight Mass Measurements of Exotic Nuclei

Atomic masses play an important role in nuclear physics and astrophysics. The need of experimental mass values for unstable nuclides has triggered the development of a wide range of mass measurement techniques, with devices installed at many laboratories around the world. We have implemented a time-of-flight magnetic-rigidity (TOF-B ) technique at the National Superconducting Cyclotron Laboratory (NSCL) that includes a position measurement for magnetic rigidity corrections and uses the A1900 separator and the S800 spectrograph. We performed a successful first experiment measuring masses of neutron-rich isotopes in the region of Z 20 30, important for calculations of processes occurring in the crust of accreting neutron stars. The masses of 16 nuclei were determined, for 61V, 63Cr, 66Mn, and 74Ni for the first time, with atomic mass excesses of 30.510(890) MeV, 35.280(650) MeV, 36.900(790) MeV, and 49.210(990) MeV, respectively. The mass resolution achieved was 1.8 10 4.

Matos, M.↗

Measurement and Analysis of Rotational Energy of Nitrogen Molecular Beam by REMPI

Molecular beams are powerful tools for diagnoses of solid surfaces and gas-surface interaction tests. Unfortunately, there are very few reports about experimental analysis of internal energy distribution (e.g. rotational energy) of molecular beams of diatomic or polyatomic molecules, because measurement of internal energy distribution is very difficult. Spectroscopic measurement techniques based on resonantly enhanced multiphoton ionization (REMPI) is very powerful for measurement in highly rarefied gas flows. In this study, the REMPI method is applied to measurement of rotational energy distribution of nitrogen molecular beams. The REMPI spectrum of the molecular beam indicates the rotational temperature higher than the translational temperature of 7.2 K estimated by assuming isentropic flows. The O and P branches of the REMPI spectrum correspond to the rotational temperature of 30 K, but the S branch of the spectrum deviates from that at 30 K. It seems to be because the non-equilibrium rotational energy distribution of the molecular beam deviates from the Boltzmann distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and physical properties of vanadium doped copper bismuth borate glasses

The structural and physical properties of xCuO(30-x)Bi{sub 2}O{sub 3}-70B{sub 2}O{sub 3}; x= 0, 5, 10, 15, 20 and 25 mol % with 2 mol %V{sub 2}O{sub 5} glasses prepared by normal melt quench technique have been investigated by means of FT-IR and physical measurement techniques. With the addition of copper oxide (x{<=} 10 mol%), the frequency bands in the higher region shift towards lower wave number, suggest the conversion of BO{sub 3} to BO{sub 4} structural units, which in turn give rise to the formation of Non Bridging Oxygen's (NBOs). For further increase in CuO (i.e. for x{>=} 10 mol %), the frequency bands shift towards higher wave number, indicate the formation of Bridging Oxygen's (BOs). The FTIR analysis reveals that the present glass system is based on the BiO{sub 3} pyramidal, BiO{sub 6} octahedral units and also on BO{sub 3} and BO{sub 4} structural units. The systematic variation in density and molar volume in these glasses indicates the effect of CuO substitution.

36 MATERIALS SCIENCE↗

Calculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes

This paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect). A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches.

42 ENGINEERING↗

Quantitative and high spatial resolution d{sub 33} measurement of piezoelectric bulk and thin films

A single beam laser interferometer based on a modified Mirau detection scheme with a vertical resolution of ∼5 pm was developed for localized d{sub 33} measurements on patterned piezoelectric films. The tool provides high spatial resolution (∼2 μm), essential for understanding scaling and processing effects in piezoelectric materials. This approach enables quantitative information on d{sub 33}, currently difficult in local measurement techniques such as piezoresponse force microscopy. The interferometer is built in a custom microscope and employs a phase lock-in technique in order to detect sub-Angstrom displacements. d{sub 33} measurements on single crystal 0.67PbMg{sub 0.33}Nb{sub 0.67}O{sub 3}-0.33PbTiO{sub 3} and bulk PbZrTiO{sub 3}-5A ceramics demonstrated agreement within <3% with measurements using a double beam laser interferometer. Substrate bending contributions to out-of-plane strain, observed in thin continuous PbZr{sub 0.52}Ti{sub 0.48}O{sub 3} films grown on Si substrates is reduced for electrode diameters smaller than 100 μm. Direct scanning across room temperature and 150 °C poled 5 μm and 10 μm features etched in 0.5 μm thick PbZr{sub 0.52}Ti{sub 0.48}O{sub 3} films doped with 1% Nb confirmed minimal substrate contributions to the effective d{sub 33,f}. Furthermore, enhanced d{sub 33,f} values were observed along the feature edges due to partial declamping from the substrate, thus validating the application of single beam interferometry on finely patterned electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The 2022 magneto-optics roadmap

Abstract Magneto-optical (MO) effects, viz. magnetically induced changes in light intensity or polarization upon reflection from or transmission through a magnetic sample, were discovered over a century and a half ago. Initially they played a crucially relevant role in unveiling the fundamentals of electromagnetism and quantum mechanics. A more broad-based relevance and wide-spread use of MO methods, however, remained quite limited until the 1960s due to a lack of suitable, reliable and easy-to-operate light sources. The advent of Laser technology and the availability of other novel light sources led to an enormous expansion of MO measurement techniques and applications that continues to this day (see section 1). The here-assembled roadmap article is intended to provide a meaningful survey over many of the most relevant recent developments, advances, and emerging research directions in a rather condensed form, so that readers can easily access a significant overview about this very dynamic research field. While light source technology and other experimental developments were crucial in the establishment of today’s magneto-optics, progress also relies on an ever-increasing theoretical understanding of MO effects from a quantum mechanical perspective (see section 2), as well as using electromagnetic theory and modelling approaches (see section 3) to enable quantitatively reliable predictions for ever more complex materials, metamaterials, and device geometries. The latest advances in established MO methodologies and especially the utilization of the MO Kerr effect (MOKE) are presented in sections 4 (MOKE spectroscopy), 5 (higher order MOKE effects), 6 (MOKE microscopy), 8 (high sensitivity MOKE), 9 (generalized MO ellipsometry), and 20 (Cotton–Mouton effect in two-dimensional materials). In addition, MO effects are now being investigated and utilized in spectral ranges, to which they originally seemed completely foreign, as those of synchrotron radiation x-rays (see section 14 on three-dimensional magnetic characterization and section 16 on light beams carrying orbital angular momentum) and, very recently, the terahertz (THz) regime (see section 18 on THz MOKE and section 19 on THz ellipsometry for electron paramagnetic resonance detection). Magneto-optics also demonstrates its strength in a unique way when combined with femtosecond laser pulses (see section 10 on ultrafast MOKE and section 15 on magneto-optics using x-ray free electron lasers), facilitating the very active field of time-resolved MO spectroscopy that enables investigations of phenomena like spin relaxation of non-equilibrium photoexcited carriers, transient modifications of ferromagnetic order, and photo-induced dynamic phase transitions, to name a few. Recent progress in nanoscience and nanotechnology, which is intimately linked to the achieved impressive ability to reliably fabricate materials and functional structures at the nanoscale, now enables the exploitation of strongly enhanced MO effects induced by light–matter interaction at the nanoscale (see section 12 on magnetoplasmonics and section 13 on MO metasurfaces). MO effects are also at the very heart of powerful magnetic characterization techniques like Brillouin light scattering and time-resolved pump-probe measurements for the study of spin waves (see section 7), their interactions with acoustic waves (see section 11), and ultra-sensitive magnetic field sensing applications based on nitrogen-vacancy centres in diamond (see section 17). Despite our best attempt to represent the field of magneto-optics accurately and do justice to all its novel developments and its diversity, the research area is so extensive and active that there remains great latitude in deciding what to include in an article of this sort, which in turn means that some areas might not be adequately represented here. However, we feel that the 20 sections that form this 2022 magneto-optics roadmap article, each written by experts in the field and addressing a specific subject on only two pages, provide an accurate snapshot of where this research field stands today. Correspondingly, it should act as a valuable reference point and guideline for emerging research directions in modern magneto-optics, as well as illustrate the directions this research field might take in the foreseeable future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fock-state view of weak-value measurements and implementation with photons and atomic ensembles

Weak measurements in combination with postselection can give rise to a striking amplification effect (related to a large ''weak value''). We show that this effect can be understood by viewing the initial state of the pointer as the ground state of a fictional harmonic oscillator. This perspective clarifies the relationship between the weak-value regime and other measurement techniques and inspires a proposal to implement fully quantum weak-value measurements combining photons and atomic ensembles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraction of information from a single quantum

We investigate the possibility of performing quantum tomography on a single qubit with generalized partial measurements and the technique of measurement reversal. Using concepts from statistical decision theory, we prove that, somewhat surprisingly, no information can be obtained using this scheme. It is shown that, irrespective of the measurement technique used, extraction of information from single quanta is at odds with other general principles of quantum physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test of timing properties of the Photek 240 PMT

Timing measurements of Silicon Photomultipliers (SiPM) at the picosecond level were performed at Fermilab. The core timing resolution of the electronic measurement technique is approximately 2 picoseconds. The single photoelectron time resolution (SPTR) was measured for the signals coming from the SiPM's. A SPTR of about one hundred picoseconds was obtained for SiPM's illuminated by laser pulses. The dependence of the SPTR on applied bias voltage and on the wavelength of the light was measured. A simple model is proposed to explain the difference in the SPTR for blue and red light. A time of flight system based on the SiPM's, with quartz Cherenkov radiators, was tested in a proton beam at Fermilab. The time resolution obtained is 35 picoseconds per SiPM. Finally, requirements for the SiPM's temperature and bias voltage stability to maintain the time resolution are discussed.

43 PARTICLE ACCELERATORS↗

Development of heat flux sensors in turbine airfoils

The objective is to develop heat flux sensors suitable for use on turbine airfoils and to verify the operation of the heat flux measurement techniques through laboratory experiments. The requirements for a program to investigate the measurement of heat flux on airfoils in areas of strong non-one-dimensional flow were also identified.

Atkinson, W. H.↗

Water vapor measurements in the 0.94 micron absorption band - Calibration, measurements and data applications

This paper describes methods and presents results for sensing the columnar content of atmospheric water vapor via differential solar transmission measurements in and adjacent to the 0.94-micron water-vapor absorption band. Calibration and measurement techniques are presented for obtaining the water vapor transmission from the radiometer measurements. Models are also presented for retrieving the columnar water vapor amount from the estimated transmission. Example retrievals are presented for radiometer measurements made during the 1986 Arizona Monsoon Season to track temporal variations in columnar water vapor amount.

Reagan, J. A.↗