At least 1,207 records · Page 67

TMIST-2 Transport Test

In anticipation of the TMIST-2 experiment in the Advanced Test Reactor, there was a need to determine if the tritium that is expected to be observed at the outlet of the experiment would be seen or if it may be lost on its way from the experiment in the core to the measurement station. To assist in resolving that issue, a bench-scale experiment was conducted in the Idaho National Laboratory’s Safety and Tritium Applied Research (STAR) facility using deuterium and a mass spectrometer in lieu of tritium with ion chambers, bubblers, and scintillation counting. The experiment replicated the concentration of the hydrogen isotope, the flow rates anticipated, and the residence times. It was found that there was initial uptake on tubing walls, presumably due to oxidation of the hydrogen isotopes to water and adsorption or isotopic exchange, but that saturates relatively quickly, and once saturated, the concentration of deuterium at the outlet of the tubing system was essentially the same as it was at the experiment inlet under the conditions modeled in the experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

Captan+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

CAPTAN+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Optimal gate-width setting for passive neutrons multiplicity counting

When setting up a passive neutron coincidence counter it is natural to ask what coincidence gate settings should be used to optimize the counting precision. If the gate width is too short then signal is lost and the precision is compromised because in a given period only a few coincidence events will be observed. On the other hand if the gate is too large the signal will be maximized but it will also be compromised by the high level of random pile-up or Accidental coincidence events which must be subtracted. In the case of shift register electronics connected to an assay chamber with an exponential dieaway profile operating in the regime where the Accidentals rate dominates the Reals coincidence rate but where dead-time is not a concern, simple arguments allow one to show that the relative precision on the net Reals rate is minimized when the coincidence gate is set to about 1.2 times the lie dieaway time of the system. In this work we show that making the same assumptions it is easy to show that the relative precision on the Triples rates is also at a minimum when the relative precision of the Doubles (or Reals) is at a minimum. Although the analysis is straightforward to our knowledge such a discussion has not been documented in the literature before. Actual measurement systems do not always behave in the ideal we choose to model them. Fortunately however the variation in the relative precision as a function of gate width is rather flat for traditional safeguards counters and so the performance is somewhat forgiving of the exact choice. The derivation further serves to delineate the important parameters which determine the relative counting precision of the Doubles and Triples rates under the regime considered. To illustrate the similarities and differences we consider the relative standard deviation that might be anticipated for a passive correlation count of an axial section of a spent nuclear fuel assembly under practically achievable conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RX J1301.9+2747: A HIGHLY VARIABLE SEYFERT GALAXY WITH EXTREMELY SOFT X-RAY EMISSION

In this paper we present a temporal and spectral analysis of X-ray data from XMM-Newton and Chandra observations of the ultrasoft and variable Seyfert galaxy RX J1301.9+2747. In both observations the source clearly displays two distinct states in the X-ray band: a long quiescent state and a short flare (or eruptive) state which differs in count rates by a factor of 5-7. The transition from the quiescent to the flare state occurs in 1-2 ks. We have observed that the quiescent state spectrum is unprecedentedly steep with a photon index {Gamma} {approx} 7.1, and the spectrum of the flare state is flatter with {Gamma} {approx} 4.4. X-rays above 2 keV were not significantly detected in either state. In the quiescent state, the spectrum appears to be dominated by a blackbody component of temperature about {approx}30-40 eV, which is comparable to the expected maximum effective temperature from the inner accretion disk. The quiescent state, however, requires an additional steep power law, presumably arising from Comptonization by transient heated electrons. The optical spectrum from the Sloan Digital Sky Survey shows Seyfert-like narrow lines for RX J1301.9+2747, while Hubble Space Telescope imaging reveals a central point source for the object. In order to precisely determine the hard X-ray component, future longer X-ray observations are required. This will help constrain the accretion disk model for RX J1301.9+2747, and shed new light on the characteristics of the corona and accretion flows around black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

DETERMINATION OF STOCHASTIC ACCELERATION MODEL CHARACTERISTICS IN SOLAR FLARES

Following our recent paper, we have developed an inversion method to determine the basic characteristics of the particle acceleration mechanism directly and non-parametrically from observations under the leaky box framework. Earlier, we demonstrated this method for obtaining the energy dependences of the escape time and pitch angle scattering time. Here, by converting the Fokker-Planck equation to its integral form, we derive the energy dependences of the energy diffusion coefficient and direct acceleration rate for stochastic acceleration in terms of the accelerated and escaping particle spectra. Combining the regularized inversion method of Piana et al. and our procedure, we relate the acceleration characteristics in solar flares directly to the count visibility data from RHESSI. We determine the timescales for electron escape, pitch angle scattering, energy diffusion, and direct acceleration at the loop top acceleration region for two intense solar flares based on the regularized electron flux spectral images. The X3.9 class event shows dramatically different energy dependences for the acceleration and scattering timescales, while the M2.1 class event shows a milder difference. The discrepancy between the M2.1 class event and the stochastic acceleration model could be alleviated by a turbulence spectrum that is much steeper than the Kolmogorov-type spectrum. A likely explanation of the X3.9 class event could be that the escape of electrons from the acceleration region is not governed by a random walk process, but instead is affected by magnetic mirroring, in which the scattering time is proportional to the escape time and has an energy dependence similar to the energy diffusion time.

79 ASTRONOMY AND ASTROPHYSICS↗

TNF-alpha-induced apoptosis is prevented by erythropoietin treatment on SH-SY5Y cells

The growth factor erythropoietin (Epo) has shown neuronal protective action in addition to its well known proerythroid activity. Furthermore, Epo has dealt with cellular inflammation by inhibiting the expression of several proinflammatory cytokines, such as IL-1 and TNF-{alpha}. The action of TNF can have both apoptotic and antiapoptotic consequences due to altered balance between different cell signalling pathways. This work has focused on the apoptotic effects of this cytokine and the potential protective action of Epo. The model we used was neuroblastoma SH-SY5Y cells cultured in the presence of 25 ng/ml TNF-{alpha} or pretreated with 25 U/ml Epo for 12 h before the addition of TNF-{alpha}. Apoptosis was evaluated by differential cell count after Hoechst staining, analysis of DNA ladder pattern, and measurement of caspase activity. Despite its ability to induce NF-{kappa}B nuclear translocation, TNF-{alpha} induced cell death, which was found to be associated to upregulation of TNF Receptor 1 expression. On the other hand, cells activated by Epo became resistant to cell death. Prevention of death receptor upregulation and caspase activation may explain this antiapoptotic effect of Epo, which may be also favoured by the induction of a higher expression of protective factors, such as Bcl-2 and NF-{kappa}B, through mechanisms involving Jak/STAT and PI3K signalling pathways.

60 APPLIED LIFE SCIENCES↗

Quantum Simulations of Fermionic Hamiltonians with Efficient Encoding and Ansatz Schemes

Here, we propose a computational protocol for quantum simulations of fermionic Hamiltonians on a quantum computer, enabling calculations on spin defect systems which were previously not feasible using conventional encodings and a unitary coupled-cluster ansatz of variational quantum eigensolvers. We combine a qubit-efficient encoding scheme mapping Slater determinants onto qubits with a modified qubitcoupled cluster ansatz and noise-mitigation techniques. Our strategy leads to a substantial improvement in the scaling of circuit gate counts and in the number of required qubits, and to a decrease in the number of required variational parameters, thus increasing the resilience to noise. We present results for spin defects of interest for quantum technologies, going beyond minimum models for the negatively charged nitrogen vacancy center in diamonds and the double vacancy in 4H silicon carbide (4H-SiC) and tackling a defect as complex as negatively charged silicon vacancy in 4H-SiC for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanisms of Electron Transfer in Two Decaheme Cytochromes from a Metal-Reducing Bacterium

Single-molecule current-voltage (I–V) spectra were collected using a scanning tunneling microscope for two decaheme c-type cytochromes, OmcA and MtrC, which are outer-membrane proteins from the dissimilatory metal-reducing bacterium Shewanella oneidensis. Although the two cytochromes are similar in heme count, charge-carrying amino-acid content, and molecular mass, their I–V spectra are significantly different. The I–V spectra for OmcA show smoothly varying symmetric exponential behavior. These spectra are well fit by a coherent tunneling model that is based on a simple square barrier description of the tunneling junction. In contrast, the I–V spectra for MtrC have pronounced breaks in slope in the positive tip bias range. Two large peaks in the normalized differential conductance spectra of MtrC were fit to a tunneling model that accounts for the possibility of transient population of empty states stabilized by vibrational relaxation. Reorganization energies deduced for the two features are similar to those normally assigned to metal centers in other metalloproteins. Work function measurements of the cytochrome films were used to convert the energies of these two spectral features to the normal hydrogen electrode scale for comparison with the midpoint potential measured using protein film voltammetry, which showed good correspondence. We conclude that MtrC mediates tunneling current by heme orbital participation. The difference in tunneling behavior between OmcA and MtrC suggests distinct physiological functions for the two cytochromes; in contrast to OmcA, MtrC appears to be tuned to a specific operating potential.

metalloprotein↗

Fermi/GAMMA-RAY BURST MONITOR OBSERVATIONS OF SGR J0501+4516 BURSTS

We present our temporal and spectral analyses of 29 bursts from SGR J0501+4516, detected with the gamma-ray burst monitor on board the Fermi Gamma-ray Space Telescope during 13 days of the source's activation in 2008 (August 22- September 3). We find that the T{sub 90} durations of the bursts can be fit with a log-normal distribution with a mean value of {approx}123 ms. We also estimate for the first time event durations of soft gamma repeater (SGR) bursts in photon space (i.e., using their deconvolved spectra) and find that these are very similar to the T{sub 90} values estimated in count space (following a log-normal distribution with a mean value of {approx}124 ms). We fit the time-integrated spectra for each burst and the time-resolved spectra of the five brightest bursts with several models. We find that a single power law with an exponential cutoff model fits all 29 bursts well, while 18 of the events can also be fit with two blackbody functions. We expand on the physical interpretation of these two models and we compare their parameters and discuss their evolution. We show that the time-integrated and time-resolved spectra reveal that E{sub peak} decreases with energy flux (and fluence) to a minimum of {approx}30 keV at F = 8.7 x 10{sup -6} erg cm{sup -2} s{sup -1}, increasing steadily afterward. Two more sources exhibit a similar trend: SGRs J1550-5418 and 1806-20. The isotropic luminosity, L{sub iso}, corresponding to these flux values is roughly similar for all sources (0.4-1.5 x 10{sup 40} erg s{sup -1}).

79 ASTRONOMY AND ASTROPHYSICS↗

IMFIT: A FAST, FLEXIBLE NEW PROGRAM FOR ASTRONOMICAL IMAGE FITTING

I describe a new, open-source astronomical image-fitting program called IMFIT, specialized for galaxies but potentially useful for other sources, which is fast, flexible, and highly extensible. A key characteristic of the program is an object-oriented design that allows new types of image components (two-dimensional surface-brightness functions) to be easily written and added to the program. Image functions provided with IMFIT include the usual suspects for galaxy decompositions (Sérsic, exponential, Gaussian), along with Core-Sérsic and broken-exponential profiles, elliptical rings, and three components that perform line-of-sight integration through three-dimensional luminosity-density models of disks and rings seen at arbitrary inclinations. Available minimization algorithms include Levenberg-Marquardt, Nelder-Mead simplex, and Differential Evolution, allowing trade-offs between speed and decreased sensitivity to local minima in the fit landscape. Minimization can be done using the standard χ{sup 2} statistic (using either data or model values to estimate per-pixel Gaussian errors, or else user-supplied error images) or Poisson-based maximum-likelihood statistics; the latter approach is particularly appropriate for cases of Poisson data in the low-count regime. I show that fitting low-signal-to-noise ratio galaxy images using χ{sup 2} minimization and individual-pixel Gaussian uncertainties can lead to significant biases in fitted parameter values, which are avoided if a Poisson-based statistic is used; this is true even when Gaussian read noise is present.

79 ASTRONOMY AND ASTROPHYSICS↗

2D k -th nearest neighbour statistics: a highly informative probe of galaxy clustering

ABSTRACT Beyond standard summary statistics are necessary to summarize the rich information on non-linear scales in the era of precision galaxy clustering measurements. For the first time, we introduce the 2D k-th nearest neighbour (kNN) statistics as a summary statistic for discrete galaxy fields. This is a direct generalization of the standard 1D kNN by disentangling the projected galaxy distribution from the redshift-space distortion signature along the line-of-sight. We further introduce two different flavours of 2D kNNs that trace different aspects of the galaxy field: the standard flavour which tabulates the distances between galaxies and random query points, and a ‘DD’ flavour that tabulates the distances between galaxies and galaxies. We showcase the 2D kNNs’ strong constraining power both through theoretical arguments and by testing on realistic galaxy mocks. Theoretically, we show that 2D kNNs are computationally efficient and directly generate other statistics such as the popular two-point correlation function (2PCF), voids probability function, and counts-in-cell statistics. In a more practical test, we apply the 2D kNN statistics to simulated galaxy mocks that fold in a large range of observational realism and recover parameters of the underlying extended halo occupation distribution (HOD) model that includes velocity bias and galaxy assembly bias. We find unbiased and significantly tighter constraints on all aspects of the HOD model with the 2D kNNs, both compared to the standard 1D kNN, and the classical redshift-space 2PCF.

79 ASTRONOMY AND ASTROPHYSICS↗

Precise determination of muon and electromagnetic shower contents from a shower universality property

We consider two new aspects of extensive air shower development universality allowing to make an accurate estimation of muon and electromagnetic (EM) shower contents in two independent ways. In the first case, to get the muon (or EM) signal in water Cherenkov tanks or in scintillator detectors, it is enough to know the vertical depth of the shower maximum X{sub max}{sup v} and the total signal in the ground detector. In the second case, the EM signal can be calculated from the primary particle energy and the zenith angle. In both cases, the parametrizations of muon and EM signals are almost independent on the primary particle nature, energy and zenith angle. Implications of the considered properties for mass composition and hadronic interaction studies are briefly discussed. The present study is performed on 28 000 proton, oxygen, and iron showers, generated with CORSIKA 6.735 for the E{sup -1} spectrum in the energy range lg (E/eV)=18.5-20 and uniformly distributed in cos{sup 2{theta}} in the zenith angle interval {theta}=0 deg. - 65 deg. for QGSJET II/Fluka interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-Resolved Line Shapes of Single Quantum Emitters via Machine Learned Photon Correlations

Solid-state single-photon emitters (SPEs) are quantum light sources that combine atomlike optical properties with solid-state integration and fabrication capabilities. SPEs are hindered by spectral diffusion, where the emitter’s surrounding environment induces random energy fluctuations. Timescales of spectral diffusion span nanoseconds to minutes and require probing single emitters to remove ensemble averaging. Photon correlation Fourier spectroscopy (PCFS) can be used to measure time-resolved single emitter line shapes, but is hindered by poor signal-to-noise ratio in the measured correlation functions at early times due to low photon counts. Here, we develop a framework to simulate PCFS correlation functions directly from diffusing spectra that match well with experimental data for single colloidal quantum dots. We use these simulated datasets to train a deep ensemble autoencoder machine learning model that outputs accurate, noiseless, and probabilistic reconstructions of the noisy correlations. Using this model, we obtain reconstructed time-resolved single dot emission line shapes at timescales as low as 10 ns, which are otherwise completely obscured by noise. This enables PCFS to extract optical coherence times on the same timescales as Hong-Ou-Mandel two-photon interference, but with the advantage of providing spectral information in addition to estimates of photon indistinguishability. Further, our machine learning approach is broadly applicable to different photon correlation spectroscopy techniques and SPE systems, offering an enhanced tool for probing single emitter line shapes on previously inaccessible timescales.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-throughput nuclear resonance time domain interferometry using annular slits

Nuclear resonance time domain interferometry (NR-TDI) is used to study the slow dynamics of liquids (that do not require Mössbauer isotopes) at atomic and molecular length scales. Here the TDI method of using a stationary two-line magnetized 57 Fe foil as a source and a stationary single-line stainless steel foil analyzer is employed. The new technique of adding an annular slit in front of a single silicon avalanche photodiode detector enables a wide range of momentum transfers (1 to 100 nm -1 by varying the distance between the annular slits and sample) with a high count rate of up to 160 Hz with a Δ q resolution of ±1.7 nm -1 at q = 14 nm -1 . The sensitivity of this method in determining relaxation times is quantified and discussed. The Kohlrausch–Williams–Watts (KWW) model was used to extract relaxation times for glycerol. These relaxation times give insight into the dynamics of the electron density fluctuations of glycerol as a function of temperature and momentum transfers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation

Purpose: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented. Methods: Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w{sub t} that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system. Results: The average difference between theoretical and experimental w{sub t} was found to range from 8% to 21%. Experimental w{sub t} values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm{sup 2} and larger are discernable. Conclusions: The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black Carbon at the Mt. Bachelor Observatory Field Campaign Report

This campaign was initiated to measure refractory black carbon (rBC, as defined in Schwarz et al. (2010)) at the Mt. Bachelor Observatory (MBO) using the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility single-particle soot photometer (SP2; unit 54). MBO is a high-elevation site located on the summit of Mt. Bachelor in central Oregon, USA (43.979°N, 121.687°W, 2,763 meters ASL). This site is operated by Professor Dan Jaffe’s group at the University of Washington Bothell and has been used continuously as an atmospheric observatory for the past 12 years (Jaffe et al., 2005; Gratz et al., 2014). The location of MBO allows frequent sampling of the free troposphere along with a wide array of plumes from regional and distant sources. MBO is currently supported with funding from the National Science Foundation (NSF) to the Principal Investigator (PI; D. Jaffe) via the project “Influence of Free Tropospheric Ozone and PM on Surface Air Quality in the Western U.S.” (#1447832) covering the period 03/15/2015 to 02/28/2018. The SP2 instrument from Droplet Measurement Technologies provides particle-resolved measurements of rBC mass loading, size and mass distributions, and mixing state. The SP2 was installed at MBO on 6/27/2016 and ran through 9/23/2016. Additional measurements at MBO during this campaign included carbon monoxide (CO), fine particulate matter (PM1), aerosol light scattering coefficients (σscat) at three wavelengths using a TSI nephelometer, aerosol absorption coefficients (σabs) with the Brechtel tricolor absorption photometer (TAP), aerosol number size distributions with a scanning mobility particle sizer spectrometer (SMPS), and black carbon (eBC) with an aethalometer. BC data from this campaign have been submitted to the ARM Data Archive. Black carbon (BC) is the predominant light-absorbing aerosol constituent in the atmosphere, and is estimated to exert a positive radiative forcing second only to CO 2 (Ramanathan and Carmichael, 2008). One of the largest sources of BC globally is biomass burning (BB). (Akagi et al., 2011; Andreae and Merlet, 2001; Bond et al., 2013; Bond et al., 2004; Reid et al., 2005b): a source that is likely to increase in the Western U.S. due to climate change (Dennison et al., 2014; Abatzoglon and Williams, 2016; Westerling et al., 2006). Given the likely increased role of BB aerosol in atmospheric forcing, we need to improve our understanding of the physical and optical properties of aged BB aerosol. During the SP2 deployment period at MBO we observed seven BB events, all of which originated from the Gap Fire in Northern California, which burned 33,867 acres in the Klamath National Forest (https://inciweb.nwcg.gov/incident/4997/). Heavy smoke plumes from this fire were transported to MBO from 8/29/2016 to 8/31/2016. We calculated back-trajectories using the National Oceanic and Atmospheric Administration (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, version 4 (Draxler, 1999; Draxler and Hess, 1997, 1998; Stein et al., 2015) to confirm transport from the fire locations to MBO. We identified the fire locations using moderate resolution imaging spectroradiometer (MODIS) satellite-derived active fire counts (Justice et al., 2002). Transport time for all of the BB events ranged from 8 to 32 hours.

54 ENVIRONMENTAL SCIENCES↗