Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The Effect of the Flux Separability Approximation on Multigroup Neutron Transport

The angular dependence of flux-weighted multigroup cross sections is commonly neglected when generating multigroup libraries. The error of this flux separability approximation is typically not isolated from other error sources due to a lack of availability of library generation and corresponding solvers that cannot relax this approximation. These errors can now be isolated and quantified with the availability of a multigroup Monte Carlo transport and multigroup library-generation capability in the OpenMC Monte Carlo transport code. This work will discuss relevant details of the OpenMC implementation, provide an example case useful for detailing the type of errors one can expect from making the flux separability approximation, and end with more realistic problems which show the impact of the approximation and highlight how it can strongly arise from an energy-dependent resonance absorption effect. Since the angle-dependence is intrinsically linked to the energy group structure, these examples also show that relaxing the flux separability approximation with angle-dependent cross sections could be used to reduce either the fine-tuning required to set a multigroup energy structure for a specific reactor type or the number of energy groups required to obtain a desired level of accuracy for a given problem. This trade-off could increase the costs of generating multigroup cross sections, and has the potential to require more memory for storing the multigroup library during the transport calculations, but it can significantly reduce the computational time required since the runtime of a discrete ordinates or method of characteristics neutron transport solver scales roughly linearly with the number of groups.

42 ENGINEERING↗

Improved mesh based photon sampling techniques for neutron activation analysis

The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inspection of Dry Storage Casks Using PGAA and NAA Techniques

In this effort, an assessment of a chloride detection method is performed for inspecting the surfaces of dry cask storage system (DCSS) canisters, with focus on the implementation of a non-destructive nuclear analysis and methodology. Some DCSS canisters (especially those located in coastal environments) will be exposed to marine environments, which can cause atmospheric stress corrosion cracking (SCC). Chloride deposits on canister surfaces provide the corrosive environment necessary for atmospheric SCC with the residual stresses and materials properties conditions. The most susceptible regions on the canister surface are the weld areas, or where cold work has been performed, and may provide the necessary driving force for crack growth. The heat-affected zones (HAZs) near welds are also potentially susceptible to atmospheric SCC due to sensitization of the material caused by chromium depletion during the welding process. Information collected from the field and from laboratory studies has not been able to rule out the possibility of atmospheric chloride induced stress corrosion cracking (CISCC), although no occurrences of atmospheric SCC in DCSS canisters have been detected to-date. A number of researchers have demonstrated that localized corrosion can take place under such situations on materials commonly used for interim storage containers, including 304SS (Cook et al. 2010; Shirai et al. 2011) and 316SS (Tani et al. 2009). In this summary, the preliminary results of a neutron activation analysis (NAA) and prompt gamma activation analysis (PGAA) are performed using MCNP6, a highly sophisticated, multi-particle Monte Carlo simulation code (with the employment of the high performance computing system at the Idaho National Laboratory), and confirm the feasibility of using PGAA and NAA as an environmental inspection methodology for detection and monitoring of small quantities of chlorine on canister surfaces. The specific signature of gamma rays due reactions of sea salt constituents are documented and summarized in this paper. The environmental constituent for passive oxide film breaching is chlorine, which can cause pitting initiation and incubation time that may lead to cracking in stainless steel. Therefore, an assessment of chloride presence at a canister surface is essential before moving to other nondestructive analysis (NDA) methods for detection of pitting and cracking. Two nonlinear acoustic techniques will also be used in our integrated research project (IRP) research study that proves to be useful in the detection of SCC: nonlinear resonant ultrasound spectroscopy (NRUS), and time revisited elastic nonlinear diagnostic (TREND). These two techniques are complementary to marine atmospheric detection techniques. In this presentation only PGAA and NAA are described in detail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Poster - 40: Treatment Verification of a 3D-printed Eye Phantom for Proton Therapy

Purpose: Ocular melanoma is a form of eye cancer which is often treated using proton therapy. The benefit of the steep proton dose gradient can only be leveraged for accurate patient eye alignment. A treatment-planning program was written to plan on a 3D-printed anatomical eye-phantom, which was then irradiated to demonstrate the feasibility of verifying in vivo dosimetry for proton therapy using PET imaging. Methods: A 3D CAD eye model with critical organs was designed and voxelized into the Monte-Carlo transport code FLUKA. Proton dose and PET isotope production were simulated for a treatment plan of a test tumour, generated by a 2D treatment-planning program developed using NumPy and proton range tables. Next, a plastic eye-phantom was 3D-printed from the CAD model, irradiated at the TRIUMF Proton Therapy facility, and imaged using a PET scanner. Results: The treatment-planning program prediction of the range setting and modulator wheel was verified in FLUKA to treat the tumour with at least 90% dose coverage for both tissue and plastic. An axial isotope distribution of the PET isotopes was simulated in FLUKA and converted to PET scan counts. Meanwhile, the 3D-printed eye-phantom successfully yielded a PET signal. Conclusions: The 2D treatment-planning program can predict required parameters to sufficiently treat an eye tumour, which was experimentally verified using commercial 3D-printing hardware to manufacture eye-phantoms. Comparison between the simulated and measured PET isotope distribution could provide a more realistic test of eye alignment, and a variation of the method using radiographic film is being developed.

60 APPLIED LIFE SCIENCES↗

Use of freeze-casting in advanced burner reactor fuel design

This paper will detail the modeling of a fast reactor with fuel pins created using a freeze-casting process. Freeze-casting is a method of creating an inert scaffold within a fuel pin. The scaffold is created using a directional solidification process and results in open porosity for emplacement of fuel, with pores ranging in size from 300 microns to 500 microns in diameter. These pores allow multiple fuel types and enrichments to be loaded into one fuel pin. Also, each pore could be filled with varying amounts of fuel to allow for the specific volume of fission gases created by that fuel type. Currently fast reactors, including advanced burner reactors (ABR's), are not economically feasible due to the high cost of operating the reactors and of reprocessing the fuel. However, if the fuel could be very precisely placed, such as within a freeze-cast scaffold, this could increase fuel performance and result in a valid design with a much lower cost per megawatt. In addition to competitive costs, freeze-cast fuel would also allow for selective breeding or burning of actinides within specific locations in fast reactors. For example, fast flux peak locations could be utilized on a minute scale to target specific actinides for transmutation. Freeze-cast fuel is extremely flexible and has great potential in a variety of applications. This paper performs initial modeling of freeze-cast fuel, with the generic fast reactor parameters for this model based on EBR-II. The core has an assumed power of 62.5 MWt. The neutronics code used was Monte Carlo N-Particle (MCNP5) transport code. Uniform pore sizes were used in increments of 100 microns. Two different freeze-cast scaffold materials were used: ceramic (MgO-ZrO{sub 2}) and steel (SS316L). Separate models were needed for each material because the freeze-cast ceramic and metal scaffolds have different structural characteristics and overall porosities. Basic criticality results were compiled for the various models. Preliminary results show that criticality is achievable with freeze-cast fuel pins despite the significant amount of inert fuel matrix. Freeze casting is a promising method to achieve very precise fuel placement within fuel pins. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculations versus measurements for residual dose rates from SNS spent structures

Here, residual dose rate measurements were conducted on target vessel #13 and proton beam window #5 after extraction from their service locations. These measurements are used to verify calculation methods of radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation of these structures. Neutronics analyses for predicting residual dose rates are carried out using the transport code MCNPX and the transmutation code CINDER90. For transport analyses a complex and rigorous geometry model of the structures and their surroundings are applied. The neutronics analyses are carried out using the Bertini and CEM high energy physics models for simulating particles interactions above the table-based cross section range. Finally, obtained calculational results are analyzed and compared to the measured dose rates and overall show good agreement within 25%, which shows applicability of the methods used in analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the size of nanoparticles on their dissolution within metal-glass nanocomposites under sustained irradiation

We investigate the dissolution law of metallic nanoparticles (NPs) under sustained irradiation. The system is composed of isolated spherical gold NPs (4–100 nm) embedded in an amorphous silica host matrix. Samples are irradiated at room temperature in the nuclear stopping power regime with 4 MeV Au ions for fluences up to 8 × 10{sup 16 }cm{sup −2}. Experimentally, the dependence of the dissolution kinetics on the irradiation fluence is linear for large NPs (45–100 nm) and exponential for small NPs (4–25 nm). A lattice-based kinetic Monte Carlo (KMC) code, which includes atomic diffusion and ballistic displacement events, is used to simulate the dynamical competition between irradiation effects and thermal healing. The KMC simulations allow for a qualitative description of the NP dissolution in two main stages, in good agreement with the experiment. Moreover, the perfect correlation obtained between the evolution of the simulated flux of ejected atoms and the dissolution rate in two stages implies that there exists an effect of the size of NPs on their dissolution and a critical size for the transition between the two stages. The Frost-Russell model providing an analytical solution for the dissolution rate, accounts well for the first dissolution stage but fails in reproducing the data for the second stage. An improved model obtained by including a size-dependent recoil generation rate permits fully describing the dissolution for any NP size. This proves, in particular, that the size effect on the generation rate is the principal reason for the existence of two regimes. Finally, our results also demonstrate that it is justified to use a unidirectional approximation to describe the dissolution of the NP under irradiation, because the solute concentration is particularly low in metal-glass nanocomposites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

TU-F-BRE-03: Application of a Novel Mass-Density Compensation Optimization Method to Improve the Response of a Liquid-Filled Ionization Chamber in Nonstandard Fields

Purpose: To improve the response of the microLion detector (PTW 31018) in small field conditions by optimizing the density of the detector's non-sensitive components using a novel method based on the detector's dose response function. Methods: The central values h(0,0) of the perturbation functions for the microLion detector and a volume of water equivalent to its sensitive volume were calculated using the Monte Carlo user code egs-chamber by scoring the dose absorbed by a 6 MV photon pencil beam incident on their centroids. Values of h(0,0) were plotted as a function of the density of the microLion's graphite electrode with the detector placed in the axial orientation. The optimized density was found by finding the minimal value of h(0,0). Results: A density of 1.37 g/cm3 was found to minimize the perturbation function of the microLion detector. The modified microLion's response was then evaluated in small square fields with sides in the range of 5 – 40 mm and found to be consistent with highly watere-quivalent detectors such as a scintillating detector (Exradin W1) and a generic alanine detector in both axial and radial orientations. Conclusion: This work illustrates a novel method which can used to optimize the design of radiation detectors in small fields. This method should also work with other optimization parameters (e.g. thickness of electrode). Density-compensated detectors have the potential to eliminate the need to evaluate nonstandard field correction factors as described by the IAEA-AAPM formalism (Alfonso et al.) and simplify future dosimetry protocols for SRS/SBRT modalities. Finally, we also expect an improvement in the response of density-compensated detectors for composite IMRT fields.

07 ISOTOPE AND RADIATION SOURCES↗

A Mercury Model of the Molly-G Fast Burst Reactor (FBR)

In order to design neutron irradiation experiments at a given nuclear reactor, one requires a representative neutron spectrum for the configuration of the reactor that will exist during the experiment. This usually implies modeling the operation of the reactor using a neutron transport code. Since the modeling of pulsed neutron reactors is quite complex, requiring coupled modeling of neutronics and thermo-structural response, the typical methodology employs analysis of the neutron spectrum which is obtained from a static keff calculation. While this time-independent Eigenfunction is not truly representative of that during a reactor pulse, we postulate that it is a reasonable representation for our purposes. The Nuclear Survivability (NS) Program at LLNL is considering fielding such experiments at the Molly-G (‘Molybdenum Godiva-II’) Fast Burst Reactor (FBR) at the White Sands Missile Range (WSMR). The goal of these experiments is to (a) test / proof / calibrate diagnostics, and (b) test the efficacy of neutron shield configurations, before fielding at other nuclear reactors, such as the Annular Core Research Reactor (ACRR) at SNL/NM. After attempting to secure either drawings or a copy of an existing MCNP model of the Molly-G FBR from various institutions, it was decided to develop a new model for use with the Mercury Monte Carlo transport code. The model described herein will be used to design these experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Exploring {sup 57}Co as a new isotope for brachytherapy applications

Purpose: The characteristics of the radionuclide {sup 57}Co make it interesting for use as a brachytherapy source. {sup 57}Co combines a possible high specific activity with the emission of relatively low-energy photons and a half-life (272 days) suitable for regular source exchanges in an afterloader. {sup 57}Co decays by electron capture to the stable {sup 57}Fe with emission of 136 and 122 keV photons. Methods: A hypothetical {sup 57}Co source based on the Flexisource brachytherapy encapsulation with the active core set as a pure cobalt cylinder (length 3.5 mm and diameter 0.6 mm) covered with a cylindrical stainless-steel capsule (length 5 mm and thickness 0.125 mm) was simulated using Geant4 Monte Carlo (MC) code version 9.4. The radial dose function, g(r), and anisotropy function F(r,{theta}), for the line source approximation were calculated following the TG-43U1 formalism. The results were compared to well-known {sup 192}Ir and {sup 125}I radionuclides, representing the higher and the lower energy end of brachytherapy, respectively. Results: The mean energy of photons in water, after passing through the core and the encapsulation material was 123 keV. This hypothetical {sup 57}Co source has an increasing g(r) due to multiple scatter of low-energy photons, which results in a more uniform dose distribution than {sup 192}Ir. Conclusions: {sup 57}Co has many advantages compared to {sup 192}Ir due to its low-energy gamma emissions without any electron contamination. {sup 57}Co has an increasing g(r) that results in a more uniform dose distribution than {sup 192}Ir due to its multiple scattered photons. The anisotropy of the {sup 57}Co source is comparable to that of {sup 192}Ir. Furthermore, {sup 57}Co has lower shielding requirements than {sup 192}Ir.

07 ISOTOPE AND RADIATION SOURCES↗

Kinetic study of the secondary plasma created in the ITER neutraliser

The properties of the secondary plasma created inside the ITER Neutral Beam Injector (NBI) neutraliser, through the interaction of the high energetic hydrogen beam with the molecular hydrogen gas, have been analysed. Starting from the results of our OBI-2 PIC Monte-Carlo numerical code, detailed kinetic of the hydrogen plasma has been studied using a Collisional-Radiative model. In this model, the electron distribution function is determined by solving a Boltzmann equation, whereas main plasma species are derived from balance equations. This paper presents preliminary results obtained in a 0D geometry, boundary conditions bing introduced through effective rates for gain and loss of particles at the neutraliser walls. It has been found that the main ion specie is H{sub 2}{sup +}, essentially coming from the ionisation of the target gas. The electron energy distribution function is not maxwellian and its mean energy is about 5 eV. The plasma-wall interactions yield a strong contribution, in particular regarding the density of molecular ion H{sub 3}{sup +}. Assuming several independent slices of plasma along the negative ions beam axis, the axial profile of the secondary plasma has been analysed. It has been found that the density and mean energy profiles of the plasma electrons are directly related to the plasma potential profile, which in turn closely follows the gas density one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experiment Design of Secondary Neutron and Charged Particles Measurement with Stopping Targets Bombarded by 100- and 230-MeV/amu Helium Ions - Paper 124

Radiotherapy using ion beams has gained momentum in radiation oncology. While the number of proton therapy facilities that have been established or are under construction is rapidly growing, interest in heavy ion (whose atomic number Z is greater than one) radiotherapy has also been revitalized in the U.S. Helium ions, with mass and charge between protons and carbon ions, have advantages of deep penetration distances with significant peak-to-entrance dose ratios and limited dose contributions from secondary neutrons and other secondary charged fragments. In consideration of these advantages, the U.S. ion beam therapy community has expressed interests in helium ions as a potential candidate for ion beam therapy, especially pediatric cases. As such, characterizing the secondary nuclear fragment field created by primary helium ion interactions along the beam delivery devices and in human tissue is important for dose assessment and patient protection. Up to now the experimental data with respect to helium ions over the therapeutic energy range, 100 - 230 MeV/amu, is scarce compared to protons and carbon ions. Kurosawa et al. measured stopping target yields and angular spectra of neutrons, protons, deuterons and tritons produced by various target materials bombarded by 100- and 180- MeV/amu helium ions; Heilbronn et al. and Cecil et al. also measured the stopping target neutron yields by 155-, 160- and 177.5-MeV/amu helium ion bombardments. We have proposed to measure angular distributions of secondary neutrons and light charged ions produced by 100- and 230-MeV/amu helium ions bombarding stopping water and iron targets. The experiment was conducted at the Heavy Ion Medical Accelerator in Chiba (HIMAC) of the National Institute of Radiological Sciences (NIRS) in Japan this June. During the literature survey for experimental setup, we found that the ratio of the ion beam range (R) to the target depth (d) varies from 0.5 - 0.98 in the stopping target measurements either for helium ions incident on various targets or carbon ions bombarding targets as tissue surrogates. The difference in the values of ratio R/d makes comparison of experimental results complicated and require accurate corrections. Hence, how the R/d ratio and cross sectional area of the targets influence the angular distributions of secondary particles is investigated by using a Monte Carlo method in this study. The influence of the depth and the cross sectional area of stopping water and iron targets on the yield and the spectra of secondary particles induced by 100- and 230-MeV/amu He ions was studied by a Monte Carlo simulation code, PHITS. The secondary charged particles and secondary neutrons who come from breakup of projectiles are highly forward-focused, while the secondary particles produced by target breakup are nearly isotropic. As the energy of {sup 4}He ions increases from 100 MeV/amu to 230 MeV/amu, the normalized intensities of charged particles decrease more gently with increasing angles, whereas the neutron angular distribution falls quickly at angles smaller than 30 deg. and starts to exceed the normalized profile of 100 MeV/amu He from 60 deg. When the target depth increases, the impact on attenuation of secondary particles is more significant for lighter target mass and higher-energy projectiles at forward angles. Also, with deeper targets, more interactions occur between the secondary particles and the target elements, which results in more target-like fragments at large and backward angles. In respect of the cross sectional area of the stopping targets, the forward angular distributions are similar to the system with smaller cross sectional area of the targets; however, no general rule was found for how the large-angle distributions are affected by the target cross sectional area. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerated Coupled Monte Carlo-Thermal Hydraulic Calculations using a Hybrid GTF-Diffusion-based Prediction Block: First Results

Accurate predictions of spatial power and temperature distributions require the coupling of a neutron transport solver with a thermal-hydraulic (TH) feedback. Nowadays, Monte Carlo (MC) codes are widely coupled to TH solvers, typically via a Picard iteration (PI) method, due to the higher fidelity that such frameworks can produce. To speed up a PI, a prediction step can produce an improved initial guess for a source distribution and feed it to the MC code. Recent work [1, 2] investigated a prediction step that uses generalized transfer functions (GTFs) to predict the macroscopic cross sections’ variations following a perturbation in TH properties, such as coolant density. The previous method also relied on first order perturbation (FOP) theory to predict perturbed power profiles, rather than using an expensive MC iterate. The implemented FOP method relied on generating a fission matrix from which the forward and adjoint eigenmodes were extracted and later used to for power calculations. The generation of the fission matrix can introduce a significant computational overhead, therefore undermining the performance of the proposed hybrid technique when applied to high-dimensional problems, e.g., full core calculations. This work attempts to improve the GTF-FOP prediction step by replacing the FOP solver with a nodal diffusion solver, thus eliminating the need to calculate a fission matrix. The GTF-diffusion step was tested for various moderator density perturbations. In each case, the predicted power distribution showed good agreement with the reference case. The latter is attributed to the generally good prediction of most spatially distributed macroscopic cross sections, except the transport cross section, which will become the focus of future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prediction of neutron production and energy spectrum by the inverse kinematic reaction between an incident 7 Li 3+ beam and a proton target in PHITS

A neutron source using the inverse kinematic reaction between lithium and proton, p( 7 Li, n) 7 Be, achieves forward-directed neutrons, potentially enhancing neutron yield in the forward direction. Despite the advantage, no evaluated-cross-section data for this reaction can be used in Monte Carlo simulation codes, such as PHITS. To solve this problem, this study aims to evaluate the applicability of the user-defined cross-section data, Frag data, for p ( 7 Li, n) 7 Be in PHITS. The simulations reproduced collisions between 7 Li 3+ ions and polypropylene targets. The Frag data was edited based on the JENDL-5 by utilizing the two-body collision kinematics. The neutron yield and angular distribution were investigated in the simulation. As a result, the forward neutron convergence with a reasonable neutron yield and energy spectrum was observed. The expected neutron yield in the forward 1-steradian area is 2.46 × 10 10 n/s when lithium-ion energy and current are 16.45 MeV and 0.1 mA.

43 PARTICLE ACCELERATORS↗

Radiation Field of Packages Carrying Spent Co-60 Radioactive Sources - 12437

Among the diverse radioactive sources commonly exploited in medical and industrial applications, Co- 60 is increasingly used as strong gamma emitter. Over time, source manufacturers favored Co-60 as opposed to other gamma emitters because its relatively short half-life (5.27 year) that minimizes issues related to the management of disused sources. Disused Co-60 sources can retain a significant amount of radioactivity (from hundreds of MBq to several GBq) that still poses safety concerns on their handling and transportation. In this context a detailed knowledge of their radiation field would provide the necessary information for taking actions in preventing unnecessary doses to the workers and the population by optimizing transportation procedures and handling operations. We modeled the geometry and the materials constituting a transportation packaging of a spent Co-60 source which had an original maximum activity of a few GBq and was enclosed in a small lead irradiator. Then we applied a Monte Carlo transport code (MCNP5) for tracking down the gamma photons emitted by the source, including the secondary photons resulting by the interaction of the source photons with the surrounding materials. This allowed for the evaluation of the radiation field inside and outside the packaging, and the corresponding equivalent dose useful for checking the compliance with the regulations and the health risk of possible radiation exposure. We found that a typical 60-liters drum carrying a spent Co-60 source, enclosed in its original irradiator, with a residual activity of 300 MBq could already overcome an equivalent dose of 0.2 mSv/h on the drum external surface, which is the maximum equivalent dose at any point of the surface for this packaging as prescribed by local regulations. This condition is even more apparent when the source is slightly displaced with respect to the rotation axis of the drum, an easily occurring condition for sources not properly packaged, generating non-compliant hot-spots on the drum surface. As an example, a displacement of 5 cm translates in an increase of 80% in the dose level on the nearest side of the drum. We also found that the equivalent dose is significantly influenced by the scattered source photons and the secondary photons, whose contribution to the radiation field is mainly determined by the package geometry. The developed model resulted in an important tool for exploring the detail of the radiation field of a spent Co-60 source packaged for transportation allowing to check for compliance with the regulations and to evaluate risks to the workers and the population. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. In the example illustrated in this work, a small Co-60 source inside its irradiator and properly packaged in a drum for transport, presents a hot-spot on the drum surface if the irradiator is displaced of just few centimeters with respect to the rotation axis of the drum. A Monte Carlo simulation provided a complete description of the radiation field in the volume surrounding the packaging as a function of photon energy showing that a significant contribution comes from source photons scattered by the package itself. As an example, the Transport Index (TI) of this packaging was calculated, resulting in a value of 0.5. This value is low when compared to the regulations, however suggests that an individual just 1 meter afar from the packaging receives, in a few hours, a dose comparable to that received with a radiograph. This might be the case of the driver of a truck transporting the packaging, in particular when a number of packages are transported at the same time. It is important to notice that the results presented in this work are general, and can be appropriately scaled to represent the radiation field of similar geometries with gamma sources of different activity. However, this quick application of a Monte Carlo simulation provides useful insights in the process of preparing a packaging for transport. This simple model suggests that this approach can be efficient for screening a number of packaging configurations and flagging those potentially not compliant with regulations, that will require a more thorough care in the packaging process. Furthermore the knowledge of the details of the radiation field can be useful for optimizing the geometry of the transport cargo, and becomes essential when a variety of packaging are transported or stored, in order to prevent hazardous situations during their handling, and hence preventing unnecessary doses to the workers and the populations. It is worth to point out that this modeling approach is completely general and can be applied to a variety of different problems not limited to the transportation of radioactive material. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical study of atomic production rate in hydrogen negative ion sources with the effect of non-equilibrium electron energy distribution function

Spatial non-uniformity of the dissociative hydrogen atom (H{sup 0}) production has been investigated in a large negative ion source (JAEA 10 A source) with the electron energy distribution function (EEDF) obtained by a Monte-Carlo simulation code for electron transport in 3D3V (three dimensional real and velocity) space. It has been shown that the H{sup 0} production rate becomes larger in the upper region (one side in the longitudinal direction) of the source chamber. This spatial non-uniformity of the H{sup 0} production profile is mainly explained by the non-equilibrium features of the EEDF in the upper region, i.e., the EEDF consists of thermal electron component with kinetic energy ε < 25 eV and fast electron component with energy ε > 25 eV in the upper region, while the EEDF mainly consists of only thermal electrons in the bottom region. These characteristics for the EEDF and the energy dependence of cross-sections for dissociation and dissociative ionization processes lead to the non-uniform profile of the H{sup 0} production. The above numerical results of the spatial H{sup 0} non-uniformity are validated and confirmed by comparisons with those by spectroscopic measurement. It has been clarified that the non-equilibrium (fast electron) component of the EEDF has a large contribution to the non-uniformity of the H{sup 0} production rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗