Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Considerations and Lessons Learned from the Use of Gamma Spectroscopy Systems at FUSRAP Project Sites - 17459

This paper will discuss the application of gamma spectroscopy systems for analysis of environmental media samples for parents and daughter progeny of the Natural Uranium and Thorium Decay Series radionuclides. The concentrations and relative ratios of naturally occurring isotopes are used to confirm the presence of FUSRAP-related wastes and for understanding the associated potential dose and health risks. Focus will be given to lessons learned from the set-up and operation of onsite gamma spectroscopy laboratories used to provide stakeholders with defensible and timely results to support FUSRAP site investigations and remediation including adaptive survey design implementation, physical remediation and waste transport, and confirmatory final status survey activities. This paper focuses on the potential impacts to gamma spectroscopy measurement accuracy from the following: - Bias caused by sample matrix effects as well as use of different library reference values between performance evaluation study providers and testing laboratories; - Use of calibration sources with limited energy ranges, and; - Selection of available alternative isotopic decay reference data for the input of line energies and their intensities. These lessons learned include discussing how inter-laboratory measurement differences from blind performance evaluation samples are affected by the manufacturer's measurement method, including equilibrium assumptions; the isotope decay information source library used by the study provider and participating laboratories; and calibration source geometry/density variances from actual sample conditions. Any of these factors can significantly impact the accuracy of reported results data. Deepening the reader's understanding of the various factors that impact the accuracy, interpretation, and overall usability of gamma spectroscopy results data from laboratories will help ensure defensible decision-making and cost-effective mission implementation within FUSRAP and similar remediation programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Living Publication

Within the ICSTI Insights Series we offer three articles on the 'living publication' that is already available to practitioners in the important field of crystal structure determination and analysis. While the specific examples are drawn from this particular field, we invite readers to draw parallels in their own fields of interest. The first article describes the present state of the crystallographic living publication, already recognized by an ALPSP (Association of Learned and Professional Society Publishers) Award for Publishing Innovation in 2006. The second article describes the potential impact on the record of science as greater post-publication analysis becomes more common within currently accepted data deposition practices, using processed diffraction data as the starting point. The third article outlines a vision for the further improvement of crystallographic structure reports within potentially achievable enhanced data deposition practices, based upon raw (unprocessed) diffraction data. The IUCr in its Commissions and Journals has for many years emphasized the importance of publications being accompanied by data and the interpretation of the data in terms of atomic models. This has been followed as policy by numerous other journals in the field and its cognate disciplines. This practice has been well served by databases and archiving institutions such as the Protein Data Bank (PDB), the Cambridge Crystallographic Data Centre (CCDC), and the Inorganic Crystal Structure Database (ICSD). Normally the models that are archived are interpretations of the data, consisting of atomic coordinates with their displacement parameters, along with processed diffraction data from X-ray, neutron or electron diffraction studies. In our current online age, a reader can not only consult the printed word, but can display and explore the results with molecular graphics software of exceptional quality. Furthermore, the routine availability of processed diffraction data allows readers to perform direct calculations of the electron density (using X-rays and electrons as probes) or the nuclear density (using neutrons as probe) on which the molecular models are directly based. This current community practice is described in our first article. There are various ways that these data and tools can be used to further analyze the molecules that have been crystallized. Notably, once a set of results is announced via the publication, the research community can start to interact directly with the data and models. This gives the community the opportunity not only to read about the structure, but to examine it in detail, and even generate subsequent improved models. These improved models could, in principle, be archived along with the original interpretation of the data and can represent a continuously improving set of interpretations of a set of diffraction data. The models could improve both by correction of errors in the original interpretation and by the use of new representations of molecules in crystal structures that more accurately represent the contents of a crystal. These possible developments are described in our second article. A current, significant, thrust for the IUCr is whether it would be advantageous for the crystallographic community to require, rather than only encourage, the archiving of the raw (unprocessed) diffraction data images measured from a crystal, a fibre or a solution. This issue is being evaluated in detail by an IUCr Working Group (see http://forums.iucr.org). Such archived raw data would be linked to and from any associated publications. The archiving of raw diffraction data could allow as yet undeveloped processing methods to have access to the originally measured data. The debate within the community about this much larger proposed archiving effort revolves around the issue of 'cost versus benefit'. Costs can be minimized by preserving the raw data in local repositories, either at centralized synchrotron and neutron research institutes, or at research universities. Archiving raw data is also perceived as being more effective than just archiving processed data in countering scientific fraud, which exists in our field, albeit at a tiny level of occurrences. In parallel developments, sensitivities to avoiding research malpractice are encouraging Universities to establish their own data repositories for research and academic staff. These various 'raw data archives', would complement the existing processed data archives. These archives could however have gaps in their coverage arising from a lack of resources. Nevertheless we believe that a sufficiently large raw data archive, with reasonable global coverage, could be encouraged and have major benefits. These possible developments, costs and benefits, are described in our third and final article on 'The living publication'.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-377: Evaluation of a Novel Transmission Detector as a Reference Chamber for Use in Beam Measurements

Purpose: To evaluate a new transmission chamber for use as a reference chamber in measurements of beam data Methods: We assessed the performance of a new transmission detector, the Stealth Chamber, manufactured by IBA (IBA Dosimetry). The chamber has an active volume of 249 cm{sup 3}, with an attenuation equivalent of <0.5mm Al. We mounted the chamber to a TrueBeam linac (Varian Medical Systems, Palo Alto, CA) such that the active area is perpendicular to the beam direction. We performed PDD and profile measurements on field sizes from 1×1 cm{sup 2} to 10×10 cm{sup 2}, as well as for a 4 mm cone. The field detector was either a CC-13 chamber (IBA Dosimetry) with an active volume of 0.13 cm{sup 3} or an Edge Detector (Sun Nuclear, Melbourne, FL) with an active volume of 0.019 cm{sup 3}. For comparison we repeated all measurements using a CC-13 or CC-01 (active volume 0.01 cm{sup 3} ) chamber as reference detectors (IBA Dosimetry).All scans were acquired using a Blue Phantom2 (IBA Dosimetry) and IBA OmniPro-Accept v7.4.24 software. Results: All measurements with the Stealth Chamber were identical to those with ion reference chambers. For both regular and filter free 6MV beams there was agreement in PDDs and profiles, including the penumbra region, for all field sizes. This was true for the 4mm cone measurement, as well. The deviation between the Stealth and ion chamber measurements was on average 0.3%. Conclusion: The Stealth Chamber gives identical beam data as a conventional ion chamber for all field sizes. The advantage of the Stealth chamber over ion chambers is its efficiency. Once mounted, there is no need to reposition the chamber with varying field sizes. This translates into a huge savings in measurement time, as well as a reduction in potential errors due to reference chamber mispositioning.

43 PARTICLE ACCELERATORS↗

Baseline Assessment of TREAT for Modeling and Analysis Needs

TREAT is an air-cooled, graphite moderated, thermal, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions simulating various types of nuclear excursions and transient undercooling situations that could occur in a nuclear reactor. After 21 years in a standby mode, TREAT is being re-activated to revive transient testing capabilities. Given the time elapsed and the concurrent loss of operating experience, current generation and advanced computational methods are being applied to begin TREAT modeling and simulation prior to renewed at-power operations. Such methods have limited value in predicting the behavior of TREAT without proper validation. Hence, the U.S. DOE has developed a number of programs to support development of benchmarks for both critical and transient operations. Extensive effort has been expended at INL to collect detailed descriptions, drawings and specifications for all aspects of TREAT, and to resolve conflicting data found through this process. This report provides a collection of these data, with updated figures that are significantly more readable than historic drawings and illustrations, compositions, and dimensions based on the best available sources. This document is not nor should it be considered to be a benchmark report. Rather, it is intended to provide one-stop shopping, to the extent possible, for other work that seeks to prepare detailed, accurate models of the core and its components. Given the nature of the variety of historic documents available and the loss of institutional memory, the only completely accurate database of TREAT data is TREAT itself. Unfortunately, disassembly of TREAT for inspection, assay, and measurement is highly unlikely. Hence the data provided herein is intended serve as a best-estimate substitute.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

Evaluation of Fracture Stress for the SiC Layer of TRISO-Coated Fuel Particles by A Modified Crush Testing

Fracture stress data for the chemical vapor deposition (CVD) SiC coatings of tri-isotropic (TRISO) carbon/silicon carbide coated fuel particles were obtained using a newly developed testing and evaluation method, and their relationship with microstructure investigated. A crush testing technique using a blanket foil at load-transferring contact has been developed for hemispherical shell SiC specimens based on finite element (FE) analysis results. Mean fracture stress varied with test material in the range of 330 650 MPa, and was connected to the combined characteristics of inner surface roughness and porosity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unique & challenging aspects of plutonium metal standards exchange program for actinide measurements

The Los Alamos National Laboratory exchange program is the only program of its kind for the distribution of plutonium (Pu) standards materials with a range of impurity contents to multiple laboratories for destructive measurements of elemental concentration. This paper discusses statistical methods used to address challenges in Pu metal exchange data by way of two case studies. Challenges include how to evaluate a data set when a large fraction of the values are minimum detection limits (MDLs), and how to determine potential outliers with limited in-formation on the true spread of the data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation of interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of 'salt-and-pepper' noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain multiscale decomposition, the proposed method is anticipated to be useful in advanced clinical and preclinical applications where the interview sampling rate varies.

60 APPLIED LIFE SCIENCES↗

Automatic lung segmentation from thoracic computed tomography scans using a hybrid approach with error detection

Lung segmentation is a prerequisite for automated analysis of chest CT scans. Conventional lung segmentation methods rely on large attenuation differences between lung parenchyma and surrounding tissue. These methods fail in scans where dense abnormalities are present, which often occurs in clinical data. Some methods to handle these situations have been proposed, but they are too time consuming or too specialized to be used in clinical practice. In this article, a new hybrid lung segmentation method is presented that automatically detects failures of a conventional algorithm and, when needed, resorts to a more complex algorithm, which is expected to produce better results in abnormal cases. In a large quantitative evaluation on a database of 150 scans from different sources, the hybrid method is shown to perform substantially better than a conventional approach at a relatively low increase in computational cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

STOCHASTIC OPTIMIZATION FOR LONG TERM CAPITAL STRUCTURES, SYSTEMS, AND COMPONENTS REFURBISHMENT AND REPLACEMENT

As commercial nuclear power plants (NPPs) pursue extended plant operations in the form of Second License Renewals (SLRs), opportunities exist for these plants to provide capital investments to ensure long-term, safe, and economic performance. Several utilities have already announced their intention to pursue extended operations for one or more of their NPPs via SLR2. The goal of this research is to develop a riskinformed approach to evaluate and prioritize plant capital investments made in preparation for, and during the period of, extended plant operations to support decisions in NPP operations. In order to prioritize project selection via a riskinformed approach we developed a single decision-making tool that integrates safety/reliability, cost, and stochastic optimization models to provide users with data analysis capabilities to more cost effectively manage plant assets. Both stochastic analysis methods—such as Monte Carlo-based sampling strategies—and multi-stage stochastic optimization strategies are employed to provide priority lists to decisionmakers in support of risk-informed decisions. We applied the proposed method to a trial application of projected replacement/refurbishment expenditures for plant capital assets (i.e., Structures, Systems, and Components [SSCs]). The objective is to optimize the SSC replacement/refurbishment schedule in terms of economic constraints, data uncertainties, and SSC reliability data, as well to generate a priority list for maximizing returns on investment.

42 ENGINEERING↗

Mechanical Properties of Uranium Silicides by Nanoindentation and Finite Elements Modeling

Three methods were used to measure the mechanical properties of U 3 Si, U 3 Si 2 , and USi. Quasi-static and continuous stiffness measurement nanoindentation were used to determine hardness and Young’s modulus, and microindentation was used to evaluate the bulk hardness. Hardness and Young’s modulus of the three U-Si compounds were both observed to increase with Si content. In conclusion, finite elements modelling was used to validate the nanoindentation data calculated for U 3 Si 2 and estimate its yield strength.

36 MATERIALS SCIENCE↗

Cosmogenic Backgrounds in Borexino at 3800 m water-equivalent depth

The solar neutrino experiment Borexino, which is located in the Gran Sasso underground laboratories, is in a unique position to study muon-induced backgrounds in an organic liquid scintillator. In this study, a large sample of cosmic muons is identified and tracked by a muon veto detector external to the liquid scintillator, and by the specific light patterns observed when muons cross the scintillator volume. The yield of muon-induced neutrons is found to be Y{sub n} = (3.10±0.11)·10{sup −4} n/(μ·(g/cm{sup 2})). The distance profile between the parent muon track and the neutron capture point has the average value λ = (81.5±2.7) cm. Additionally the yields of a number of cosmogenic radioisotopes are measured for {sup 12}N, {sup 12}B, {sup 8}He, {sup 9}C, {sup 9}Li, {sup 8}B, {sup 6}He, {sup 8}Li, {sup 11}Be, {sup 10}C and {sup 11}C. All results are compared with Monte Carlo simulation predictions using the FLUKA and GEANT4 packages. General agreement between data and simulation is observed for the cosmogenic production yields with a few exceptions, the most prominent case being {sup 11}C yield for which both codes return about 50% lower values. The predicted μ-n distance profile and the neutron multiplicity distribution are found to be overall consistent with data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Percutaneous Aspiration Thrombectomy vs. Anticoagulation Therapy to Treat Acute Iliofemoral Venous Thrombosis: 1-year Follow-up Results of a Randomised, Clinical Trial

PurposeThe purpose of this study was to compare the efficacy of percutaneous aspiration thrombectomy (PAT) followed by standard anticoagulant therapy, with anticoagulation therapy alone, for the treatment of acute proximal lower extremity deep vein thrombosis.MethodsIn this randomised, prospective study, 42 patients with acute proximal iliofemoral deep vein thrombosis documented via Doppler ultrasound examination, were separated into an interventional treatment group (16 males, 5 females, average age 51 years) and a medical treatment group (13 males, 8 females, average age 59 years). In the interventional group, PAT with large-lumen 9-F diameter catheterisation was applied, after initiation of standard anticoagulant therapy. Balloon angioplasty (n 19) and stent implementation (n: 14) were used to treat patients with residual stenosis (>50 %) after PAT. Prophylactic IVC filters were placed in two patients. The thrombus clearance status of the venous system was evaluated by venography. In both the medical and interventional groups, venous patency rates and clinical symptom scores were evaluated at months 1, 3, and 12 after treatment.ResultsDeep venous systems became totally cleared of thrombi in 12 patients treated with PAT. The venous patency rates in month 12 were 57.1 and 4.76 % in the interventional and medical treatment groups, respectively. A statistically significant improvement was observed in clinical symptom scores of the interventional group (PAT) with or without stenting (4.23 ± 0.51 before treatment; 0.81 ± 0.92 at month 12) compared with the medical treatment group (4.00 ± 0.63 before treatment; 2.43 ± 0.67 at month 12). During follow-up, four patients in the medical treatment and one in the interventional group developed pulmonary embolisms.ConclusionsFor treatment of acute deep vein thrombosis, PAT with or without stenting is superior to anticoagulant therapy alone in terms of both ensuring venous patency and improving clinical symptoms. PAT is a safe, inexpensive, and easily performed method of endovascular treatment with a low rate of major complications. Our present findings and literature data suggest that PAT can be used as first-line treatment in proximal deep vein thrombosis patients, especially when thrombolytic treatment is contraindicated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AN ESTIMATE OF SPENT NUCLEAR FUEL MECHANICAL LOADS IN THE GENERAL 30 CM PACKAGE DROP SCENARIO

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transport to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. Researchers at Pacific Northwest National Laboratory (PNNL) have completed an extensive finite element study to characterize and estimate the potential mechanical loads on SNF during a hypothetical 30 cm drop of an SNF transportation package. This modeling study is validated with test data collected by the SFWST program during a physical test campaign that included one-third scale package drop tests and full-scale single fuel assembly drop tests. The test campaign was led by Sandia National Laboratories (SNL) and included international collaboration with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM). The key contribution of the modeling study is to go beyond the limitations of the limited number of physical tests to estimate the impact response to variations in impact angle, initial gap conditions, fuel assembly design, burnup and other parameters that affect the mechanical loads. The methodology of this study included a classic parametric study to calculate the impact response of highly detailed fuel assemblies over many combinations of parameters. Models of a 17x17 pressurized water reactor fuel assembly and a generic 10x10 boiling water reactor fuel assembly were both used in this study to cover the major fuel assembly types in the US inventory. Over 2,000 impact responses were calculated. The results of the parametric study were evaluated using traditional methods and basic statistics. The results were also used to construct a damage model using multiple nonlinear regression techniques to predict the mechanical loads over the full range of all input parameters. The damage model was found to work very well for all impact angle cases where the cask came to rest on its side. It was concluded that end drop cases where the cask remained vertical (instead of tipping over onto its side) were not sufficiently characterized by the current set of parametric study cases to include in the damage model, but it was not a priority to fully investigate that range because the highest mechanical loads were observed in the broader range of side impact cases. This modeling work provides sufficient insight into the mechanical loads on SNF during a hypothetical 30 cm package drop that, when considered along with the physical test data collected by the SNL-led team, the SFSWT program can consider the knowledge gap closed.

Klymyshyn, Nicholas A.↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗