Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Library”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Proton Therapy in Children: A Systematic Review of Clinical Effectiveness in 15 Pediatric Cancers

Because it spares many normal tissues and reduces the integral dose, proton therapy (PT) is the preferred tumor irradiation technique for treating childhood cancer. However, to the best of our knowledge, no systematic review of the clinical effectiveness of PT in children has been reported in the scientific literature. A systematic search for clinical outcome studies on PT published between 2007 and 2015 was performed in Medline (through OVID), EMBASE, and the Cochrane Library. Twenty-three primary studies were identified, including approximately 650 patients overall. The median/mean follow-up times were limited (range, 19-91 months). None of the studies were randomized, 2 were comparative, and 20 were retrospective. Most suffered from serious methodologic limitations, yielding a very low level of clinical evidence for the outcomes in all indications. For example, for retinoblastoma, very low-level evidence was found that PT might decrease the incidence of second malignancies. For chondrosarcoma, chordoma, craniopharyngioma, ependymoma, esthesioneuroblastoma, Ewing sarcoma, central nervous system germinoma, glioma, medulloblastoma, osteosarcoma, and rhabdomyosarcoma, there was insufficient evidence to either support or refute PT in children. For pelvic sarcoma (ie, nonrhabdomyosarcoma and non-Ewing sarcoma), pineal parenchymal tumor, primitive neuroectodermal tumor, and “adult-type” soft tissue sarcoma, no studies were identified that fulfilled the inclusion criteria. Although there is no doubt that PT reduces the radiation dose to normal tissues and organs, to date the critical clinical data on the long-term effectiveness and harm associated with the use of PT in the 15 pediatric cancers under investigation are lacking. High-quality clinical research in this area is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comet solutions to a stylized BWR benchmark problem

In this paper, a stylized 3-D BWR benchmark problem was used to evaluate the performance of the coarse mesh radiation transport method COMET. The benchmark problem consists of 560 fuel bundles at 3 different burnups and 3 coolant void states. The COMET solution was compared with the corresponding Monte Carlo reference solution using the same 2-group material cross section library for three control blade (rod) configurations, namely, all rods out (ARO), all rods in (ARI) and some rods in (SRJ). The differences in the COMET and MCNP eigenvalues were 43 pcm, 66 pcm and 32 pcm for the ARO, ARI and SRI cases, respectively. These differences are all within 3 standard deviations of the COMET uncertainty. The average relative differences in the bundle averaged fission densities for these three cases were 0.89%, 1.24%, and 1.05%, respectively. The corresponding differences in the fuel pin averaged fission densities were 1.24%, 1.84% and 1.29%, respectively. It was found that COMET is 3,000 times faster than Monte Carlo, while its statistical uncertainty in the fuel pin fission density is much lower than that of Monte Carlo (i.e., {approx}40 times lower). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-noise, radiation tolerant SiCpms

Over the last 10 years, our R&D effort has resulted in a steady progress on improving Geiger detector array technology performance, verifying their reliability and developing three cell layout libraries containing more than 2200 primitive cells for Si and SiC Geiger based single-photon detectors and silicon ROIC array fabrication. Awards from DOE, NASA and DOD, as wells as commercial R&D orders supported much progress, relevant to this program. The expertise gained and the technologies developed or qualified during these programs provided the design database and expertise to carry out the development of this new SiC photomultiplier (SiCpm) technology, successful fabrication of SiCpm detectors, and evaluation of their radiation hardness. After irradiation with protons and neutrons at 1015cm-2 and 1014cm-2 respectively, SiCpms proved radiation hardness, exceeding the expected radiation tolerance The defects induced by irradiation were mainly point defects. A new improved DLTS method (fDLTS – full wave DLTS) hardware and data processing software specific to investigating radiation damage in SiC was developed. Further work is needed to better characterize and control defects induced by charged particles. We recommend further funding of radiation hardened technology development and validation; qualification of device-specific characterization methods like f-DLTS, development of more methods to evaluate defects in SiC, more active involvement of the national labs in evaluating the SiCpm devices, and DOE support of technology transfer to a qualified foundry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-C-BRE-10: A Streamlined Approach to EPID Transit Dosimetry

Purpose: To investigate the feasibility of a simple and efficient transit dosimetry method using the electronic portal imaging device (EPID) for dose delivery error detection and prevention. Methods: In the proposed method, 2D reference transit images are generated for comparison with online images acquired during treatment. Reference transit images are generated by convolving through-air EPID measurements of each field with pixel-specific kernels selected from a library of pre-calculated Monte Carlo pencil kernels of varying radiological thickness. The kernel used for each pixel is selected based on the calculated radiological thickness of the patient along a line joining the pixel and the virtual source. The accuracy of the technique was evaluated in flat homogeneous and heterogeneous plastic water phantoms, a heterogeneous cylindrical phantom, and an anthropomorphic head phantom. Gamma criteria of 3%/3 mm was used to quantify the accuracy of the technique for the various cases. Results: An average of 99.9% and 99.7% of the points in the comparison between the measured and predicted images passed a 3%/3mm gamma for the homogeneous and heterogeneous plastic water phantoms, respectively. 97.1% of the points passed for the analysis of the heterogeneous cylindrical phantom. For the anthropomorphic head phantom, an average of 97.8% of points passed the 3%/3mm gamma criteria for all field sizes. Failures were observed primarily in areas of drastic thickness or material changes and at the edges of the fields. Conclusion: The data suggest that the proposed transit dosimetry method is a feasible approach to in vivo dose monitoring. Future research efforts could include implementation for more complex fields and sensitivity testing of the method to setup errors and changes in anatomy. Oncology Data Systems provided partial funding support but did not participate in the collection or analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross Section Generation Capability in Griffin

The Griffin code is a Multiphysics Object-Oriented Simulation Environment (MOOSE) based reactor multiphysics analysis application jointly developed by Idaho National Laboratory and Argonne National Laboratory. The code includes a variety of steady-state solvers for fixed-source, k-eigenvalue, adjoint, and subcritical multiplication, as well as transient solvers for point-kinetics, improved quasi-static, and spatial dynamics. The code reads multigroup cross sections in the ISOXML format generated from external deterministic or Monte Carlo cross section generation codes. The implementation of the cross section generation capability in Griffin was initiated last year by plugging in the cross section application programming interface (CSAPI) and reviewing the methodologies for treating particulate fuels. The focus this year was on improving the CSAPI integration and implementing advanced self-shielding methods for applications to advanced reactor problems with TRISO fuels. First, the process for cross section library generation was updated to accurately and rigorously produce isotopic cross section data. Second, the on-the-fly slowing down method for the resonance treatment was implemented in CSAPI to improve the accuracy of effective multigroup cross sections in the resonance energy range. Among various on-the-fly slowing down methods, the equivalent Dancoff factor cell method was employed. Third, the iterative local spatial self-shielding method was implemented under the calculation framework of the equivalent Dancoff factor cell method to accurately deal with the double heterogeneity effect of particulate fuel. The updated CSAPI with the advanced self-shielding methods, together with the cross section libraries generated based on the improved process, were tested for the very high temperature reactor (VHTR), high temperature test reactor (HTTR), and Empire benchmark problems with various resonance self-shielding conditions, indicating that the updated CSAPI in Griffin is able to produce multigroup cross sections accurately and efficiently. We also show that the methodology works well for pebble bed fuel from HTR-10, but the capability still needs to be fully integrated into CSAPI. In the future, further benchmark tests will be performed for various thermal reactor core problems, including particulate fuel-based pebble bed reactors.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of tsunami in the validation of scale 6.1 for the Swedish spent fuel repository - 14381

In March 2011 SKB applied to the Swedish Radiation Safety Authority (SSM) for a permit to build a final repository for spent Fuel and an encapsulation plant (Clink). The application contained a criticality safety analysis for the canisters to be used in Clink and the copper canister to be used in the final repository. In 2012 SSM requested several updates to the application. One of SSM's concerns was the validation of the codes. SSM emphasized that SKB must improve the method to select critical experiments to the validation suite. To satisfy this demand, SKB used the tool Tsunami in the Scale 6.1 code package to select experiments from the handbook of criticality experiment (IHECSBE). With help of sensitivity files SKB evaluated almost 700 experiments from the LEU-COMP-THERM library. SKB then picked the experiments that most resembled our safety cases. The sensitivity coefficient, ck, from Tsunami has been used to evaluate the similarity between the experiments and the applications. It has been considered that a ck over 0.8 provides a 'good enough' similarity between the experiment and our evaluated safety cases. For the different safety cases between 50-600 experiments satisfied the 0.8 criteria giving a good base of data for statistical analysis. It is worth noticing that PWR-fuel generally receives a higher ck than BWR fuel. Initial analysis shows that the differences in results between BWR and PWR can be explained by a larger sensitivity for the U{sup 238} n,n' part of the cross section in the PWR cases. To make sure the validation covers all materials and required physical parameters a gap analysis was made using engineering judgement by criticality safety experts. From this exercise additional experiments were added to the suite. This paper will discuss the Tsunami results for different safety cases and the reasons for differences between them. It will also present the final results of the validation and discuss experiments that were excluded from the validation suite. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Customized multi-group cross section generation with NJOY for discrete ordinates X-ray computed tomography and radiography simulation - 25589

The purpose of this work was to explore the creation of photo-atomic multi-group cross section libraries to be used with a software package DOCTORS (Discrete Ordinates Computed Tomography and Radiography Simulator). This software solves the linear Boltzmann equation using the discrete ordinates method. To create these libraries, NJOY2016 was used, creating both fine and broad energy multi-group cross section files. The cross section's accuracy was tested against an equivalent Monte Carlo simulation using MCNP6. Two simulation geometries were used. The first, a cylindrical water phantom with a single source projection placed in front, simulating an X-ray radiography. The second used the same water phantom with 16 cone beam sources placed evenly around the phantom to simulate a computed tomography (CT) scan. The accuracy of the fine energy multi-group cross sections when used in DOCTORS has been verified. The accuracy of the broad energy multigroup cross sections when used in DOCTORS shows that more work must be done before they can be used reliably. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

`SkyPy`: A package for modelling the Universe

SkyPy is an open-source Python package for simulating the astrophysical sky. It comprises a library of physical and empirical models across a range of observables and a command-line script to run end-to-end simulations. The library provides functions that sample realisations of sources and their associated properties from probability distributions. Simulation pipelines are constructed from these models using a YAML-based configuration syntax, while task scheduling and data dependencies are handled internally and the modular design allows users to interface with external software. SkyPy is developed and maintained by a diverse community of domain experts with a focus on software sustainability and interoperability. By fostering development, it provides a framework for correlated simulations of a range of cosmological probes including galaxy populations, large scale structure, the cosmic microwave background, supernovae and gravitational waves. Version 0.4 implements functions that model various properties of galaxies including luminosity functions, redshift distributions and optical photometry from spectral energy distribution templates. Future releases will provide additional modules, for example, to simulate populations of dark matter halos and model the galaxy-halo connection, making use of existing software packages from the astrophysics community where appropriate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNPX-CINDER'90 Simulation of Photonuclear Mo-99 Production Experiments

The MCNPX and CINDER'90 codes were used to support design of experiments investigating Mo-99 production with a 20-MeV electron beam. Bremsstrahlung photons produced by the electron beam interacting with the target drive the desired Mo-100({gamma},n)Mo-99 reaction, as well as many undesired reactions important to accurate prediction of radiation hazards. MCNPX is a radiation transport code and CINDER'90 is a transmutation code. They are routinely used together for accelerator activation calculations. Low energy neutron fluxes and production rates for nonneutron and high energy neutron induced reactions computed using MCNPX are inputs to CINDER'90. CINDER'90 presently has only a neutron reaction cross section library up to 25 MeV and normally the other reaction rates come from MCNPX physics models. For this work MCNPX photon flux tallies modified by energy response functions prepared from evaluated photonuclear cross section data were used to tally the reaction rates for CINDER'90 input. The cross section evaluations do not provide isomer to ground state yield ratios so a spin based approximation was used. Post irradiation dose rates were calculated using MCNPX with CINDER'90 produced decay photon spectra. The sensitivity of radionuclide activities and dose rates to beam parameters including energy, position, and profile, as well as underlying isomer assumptions, was investigated. Three experimental production targets were irradiated, two natural Mo and one Mo-100 enriched. Natural Mo foils upstream of the targets were used to analyze beam position and profile by exposing Gafchromic film to the foils after each irradiation. Activation and dose rate calculations were rerun after the experiments using measured beam parameters for comparison with measured Mo-99 activities and dose rates.

Accelerator Design, Technology, and Operations↗

Hybrid parallel code acceleration methods in full-core reactor physics calculations

When dealing with nuclear reactor calculation schemes, the need for three dimensional (3D) transport-based reference solutions is essential for both validation and optimization purposes. Considering a benchmark problem, this work investigates the potential of discrete ordinates (Sn) transport methods applied to 3D pressurized water reactor (PWR) full-core calculations. First, the benchmark problem is described. It involves a pin-by-pin description of a 3D PWR first core, and uses a 8-group cross-section library prepared with the DRAGON cell code. Then, a convergence analysis is performed using the PENTRAN parallel Sn Cartesian code. It discusses the spatial refinement and the associated angular quadrature required to properly describe the problem physics. It also shows that initializing the Sn solution with the EDF SPN solver COCAGNE reduces the number of iterations required to converge by nearly a factor of 6. Using a best estimate model, PENTRAN results are then compared to multigroup Monte Carlo results obtained with the MCNP5 code. Good consistency is observed between the two methods (Sn and Monte Carlo), with discrepancies that are less than 25 pcm for the k{sub eff}, and less than 2.1% and 1.6% for the flux at the pin-cell level and for the pin-power distribution, respectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systematic Review of Radiation Therapy Toxicity Reporting in Randomized Controlled Trials of Rectal Cancer: A Comparison of Patient-Reported Outcomes and Clinician Toxicity Reporting

The use of multimodal treatments for rectal cancer has improved cancer-related outcomes but makes monitoring toxicity challenging. Optimizing future radiation therapy regimens requires collection and publication of detailed toxicity data. This review evaluated the quality of toxicity information provided in randomized controlled trials (RCTs) of radiation therapy in rectal cancer and focused on the difference between clinician-reported and patient-reported toxicity. Medline, EMBASE, and the Cochrane Library were searched (January 1995-July 2013) for RCTs reporting late toxicity in patients treated with regimens including preoperative (chemo)radiation therapy. Data on toxicity measures and information on toxicity reported were extracted using Quantitative Analyses of Normal Tissue Effects in the Clinic recommendations. International Society for Quality of Life Research standards on patient-reported outcomes (PROs) were used to evaluate the quality of patient-reported toxicity. Twenty-one RCT publications met inclusion criteria out of 4144 articles screened. All PRO studies reported higher rates of toxicity symptoms than clinician-reported studies and reported on a wider range and milder symptoms. No clinician-reported study published data on sexual dysfunction. Of the clinician-reported studies, 55% grouped toxicity data related to an organ system together (eg “Bowel”), and 45% presented data only on more-severe (grade ≥3) toxicity. In comparison, all toxicity grades were reported in 79% of PRO publications, and all studies (100%) presented individual symptom toxicity data (eg bowel urgency). However, PRO reporting quality was variable. Only 43% of PRO studies presented baseline data, 28% did not use any psychometrically validated instruments, and only 29% of studies described statistical methods for managing missing data. Analysis of these trials highlights the lack of reporting standards for adverse events and reveals the differences between clinician and patient reporting of toxicity. Recommendations for improving the quality of adverse event data collection are provided, with the aim of improving critical appraisal of outcomes for future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

60 APPLIED LIFE SCIENCES↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural characterization and regulatory element analysis of the heart isoform of cytochrome c oxidase VIa

In order to investigate the mechanism(s) governing the striated muscle-specific expression of cytochrome c oxidase VIaH we have characterized the murine gene and analyzed its transcriptional regulatory elements in skeletal myogenic cell lines. The gene is single copy, spans 689 base pairs (bp), and is comprised of three exons. The 5'-ends of transcripts from the gene are heterogeneous, but the most abundant transcript includes a 5'-untranslated region of 30 nucleotides. When fused to the luciferase reporter gene, the 3.5-kilobase 5'-flanking region of the gene directed the expression of the heterologous protein selectively in differentiated Sol8 cells and transgenic mice, recapitulating the pattern of expression of the endogenous gene. Deletion analysis identified a 300-bp fragment sufficient to direct the myotube-specific expression of luciferase in Sol8 cells. The region lacks an apparent TATA element, and sequence motifs predicted to bind NRF-1, NRF-2, ox-box, or PPAR factors known to regulate other nuclear genes encoding mitochondrial proteins are not evident. Mutational analysis, however, identified two cis-elements necessary for the high level expression of the reporter protein: a MEF2 consensus element at -90 to -81 bp and an E-box element at -147 to -142 bp. Additional E-box motifs at closely located positions were mutated without loss of transcriptional activity. The dependence of transcriptional activation of cytochrome c oxidase VIaH on cis-elements similar to those found in contractile protein genes suggests that the striated muscle-specific expression is coregulated by mechanisms that control the lineage-specific expression of several contractile and cytosolic proteins.

Non-NASA Center↗

Memory forensic analysis of a programmable logic controller in industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLCs) are used to automate physical processes such as nuclear plants and power grid stations, and are often subject to cyber attacks. As in conventional IT domain, the memory analysis of the PLCs can help answer important forensic questions about the attack, such as the presence of malicious firmware, injection of modified control logic (the program running on the PLC), and manipulation of I/O devices (e.g., sensors and actuators). Unlike conventional IT domain, PLCs have heterogeneous hardware architecture, proprietary firmware and control software, making it challenging to employ a unified framework for their memory forensics. For merely extracting artifacts of forensic importance, reverse-engineering the firmware is a tedious task, and the effort needs to be repeated for every PLC model. As a community, a step-wise approach to tackle this challenge is to analyze the memory of specific PLCs, and subsequently find a generic framework applicable to all PLCs. Our work is a step forward in this direction. By following a methodology that focuses on the functional layer of PLCs instead of reverse engineering the firmware, we analyze the digital forensic artifacts available in a common PLC, Allen-Bradley ControlLogix 1756-L61. Before diving into the memory dump, we analyze the PLC control software to create a list of important artifacts that are sure to exist in the PLC memory dump. The approach employs a setup where PLC control software RSLogix-5000 is connected to the PLC, and the memory dump can be obtained as and when needed. We create test cases that sequentially highlight each category of artifacts, followed by an examination of the resultant impact on memory. After attaining the listed artifacts, we employ conventional string and known data searches to extract interesting information present in this PLC's memory. The memory analysis profile, presented as a Python library and shared with the community, can help a forensic investigator to readily extract forensic artifacts from the same model's controller. The adopted approach may help researchers in creating memory profile of other PLCs, and ultimately formulating a generic PLC memory analysis framework.

Rais, Muhammad Haris↗

Reduce-Order Modeling of Multigroup Neutron Cross Sections for High-Temperature Gas-cooled Reactors

Deterministic neutronics calculations rely on multigroup neutron cross section libraries, which usually consists of a database of tabulated values, used to calculate the cross sections through multivariate linear interpolation. However, interpolation of the multidimensional cross section data becomes memory inefficient and time consuming as the number of tabulations increases, significantly slowing down the neutronics calculation, especially in the case of micro cross section libraries where every isotope (on the order of hundreds) has its own set of specific reactions and cross sections. To address this challenge, this work constructs efficient and robust reduced-order models (ROMs) of the multi-group cross sections to support the Griffin simulation of high-temperature gas-cooled reactors (HTGRs). The first part of the study investigates the linearity of the multi-group cross section data across isotopes, reaction types and energy groups on pre-generated datasets for the purpose of dimensionality reduction. Secondly, a down-selection of ROM techniques is presented on representative classical machine learning (ML) techniques, including variants of linear regression, kernel-based methods, tree-based algorithms, and artificial neural networks. The selection criteria jointly consider the memory efficiency, predictive accuracy, prediction speed, and scalability in comparison to the multidimensional interpolation. Among all the ML techniques, deep neural networks (DNNs) have proven to be the best selection with sufficient accuracy, high robustness, good memory efficiency, great scalability, and superior flexibility. DNNs for have been trained for all isotopes in this work and systematic Griffin testing is ongoing at this moment to ensure the feasibility of this ROM technique for cross section predictions.

42 - ENGINEERING↗

The Prognostic Value of a Pathologic Complete Response After Neoadjuvant Therapy for Digestive Cancer: Systematic Review and Meta-Analysis of 21 Studies

Background: Neoadjuvant therapy (NAT) before radical excision has become the preferred initial option for locally advanced digestive cancers such as esophageal cancer (EC), esophagogastric junction adenocarcinoma (EGJAC), gastric adenocarcinoma (GAC), rectal cancer (RC), and pancreatic cancer (PC). Although some patients reportedly achieve a pathologic complete response (pCR) after neoadjuvant therapy, the published data are inconsistent regarding whether pCR yields a survival benefit. The current meta-analysis was performed to assess the potential prognostic value of pCR after preoperative therapy for patients with digestive cancers. Methods: An extensive electronic search in PubMed, Web of Science, and the Cochrane Library was performed for relevant articles, from which data relative to independent correlations of pCR with overall survival (OS) and disease-free survival (DFS) were extracted for analysis. A random-effects model was used to calculate the pooled hazard ratios (HRs) with their corresponding 95% confidence intervals (CIs). Results: The study identified 6780 patients who met the inclusion and exclusion criteria. The results showed that pCR was significantly correlated with better OS (HR, 0.50; 95% CI, 0.43–0.58; P < 0.001) and DFS (HR, 0.49; 95% CI, 0.40–0.60; P < 0.001) for the digestive cancer patients who achieved pCR than for those who did not achieve pCR. Subgroup analysis showed that the correlation of pCR with OS was significant in EC (HR, 0.57; 95% CI, 0.47–0.69; P < 0.001), EGJAC/GAC (HR, 0.38; 95% CI, 0.17–0.86; P = 0.02), RC (HR, 0.48; 95% CI, 0.28–0.81; P = 0.006), and PC (HR, 0.41; 95% CI, 0.17–0.97; P = 0.04). In addition, the survival benefit for pCR patients was of similar magnitude, irrespective of the type of study, type of NAT, or ethnicity. Conclusions: A pCR is correlated with favorable survival outcomes compared with a non-pCR for digestive cancer patients after NAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covariance Testing at BNL [Slides]

This presentation discusses testing implemented in FUDGE & ADVANCE in regard to proper ENDF formatting: STAN, STANEF, CHECKR, FUDGE, NJOY, convert to BOXR format, plotting, endfcovreport.py which is an overview of ENDF library’s covariance contents, and covariance Matrix class implements that are the core of all GNDS covariance. Several checks are performed, including symmetric, real, positive definite, condition # of Eigenvalues, and too big uncertainties. The presentation states that it can fix too big and/or small uncertainties and that it can plot matrices. It states that further testing is recommended by CSEWG but has not yet been implemented and suggests methods such as documentation which needs a human to execute, completeness which is partially complete, and reasonableness which has not been started. The presentation concludes by elaborating on reasonableness and states that only cross section is documented, that similar limits on CP reactions cross sections are needed, that maximum limits are needed too which is tricky since ENDF assumes Normal PDFs, and that there may be other observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗