Measurement of high-temperature thermal conductivity of Lucalox /Al2O3/ using a heat pipe technique.

The thermal conductivity of Lucalox, a high-purity form of aluminum oxide, has been measured over the temperature range from 870 to 1400 C. The technique employed is a novel one using a lithium-filled heat pipe in series with a gas-gap variable-heat-conductance unit as a heat source. The procedure makes it possible to measure heat flux through the sample directly. The measurements indicate that the thermal conductivity of high-purity aluminum oxide has a minimum value of about 0.05 W/cm deg C at 950 C and increases with higher temperatures to values in the range of 0.3 W/cm deg C at 1400 C.

Forman, R.↗

The dynamic behavior of articulated pipes conveying fluid with periodic flow rate.

The plane motion of two rigid, straight articulated pipes conveying fluid is examined. In contrast to previous work, the flow rate is not taken as constant, but is allowed to have small periodic oscillations about a mean value, as would be expected in a pump-driven system. It is shown that in the presence of such disturbances, both parametric and combination resonances are possible. When the system can also admit loss of stability by static buckling or by flutter, it is found that the presence of small periodic disturbances constitutes a destabilizing effect. Floquet theory and converging infinite determinant expansions are used to illustrate a basic difference between systems which lose stability by divergence and those that lose stability by flutter. An algebraic criterion is obtained for the minimum amplitude of flow-rate oscillation required for the system to be affected by the presence of small disturbances.

Bohn, M. P.↗

Throttleable heat pipe

Variable thermal conductance is provided by throttling or interrupting vapor flow between evaporator and condenser sections of heat pipe. Potential advantage of throttling technique is that no bulky gas reservoirs are required. Entire condenser is maintained at nearly uniform temperature so there is better thermal interface with surrounding equipment.

Marcus, B. D.↗

Heat pipe with hot gas reservoir

Heat pipe can reverse itself with gas reservoir acting as evaporator, leading to rapid recovery from liquid in reservoir. Single layer of fine-mesh screen is included inside reservoir to assure uniform liquid distribution over hottest parts of internal surface until liquid is completely removed.

Marcus, B. D.↗

Fluidics research, including vortex and jet pipe valves

The research at the Systems and Control Laboratory is reported. Topics discussed include: response characteristics of laminar fluidic amplifiers, power amplification with a vortex valve, pulse-supply-mode fluidics, speed control system employing a jet pipe valve, and the fluidics reference center.

Source record↗

Three dimensional laser Doppler velocimeter turbulence measurements in a pipe flow

The mean and turbulent u, v, and w components of a gaseous fully developed turbulent pipe flow were measured with a laser Doppler velocimeter system. Measurements of important system parameters are presented and discussed in relation to the measurement accuracy. Simultaneous comparisons of the laser Doppler and hot wire anemometer measurements in the turbulent flow provided evidence that the two systems were responding to the same flow phenomena.

Fuller, C. E., III↗

Space shuttle heat pipe thermal control systems

Heat pipe (HP) thermal control systems designed for possible space shuttle applications were built and tested under this program. They are: (1) a HP augmented cold rail, (2) a HP/phase change material (PCM) modular heat sink and (3) a HP radiating panel for compartment temperature control. The HP augmented cold rail is similar to a standard two-passage fluid cold rail except that it contains an integral, centrally located HP throughout its length. The central HP core helps to increase the local power density capability by spreading concentrated heat inputs over the entire rail. The HP/PCM modular heat sink system consists of a diode HP connected in series to a standard HP that has a PCM canister attached to its mid-section. It is designed to connect a heat source to a structural heat sink during normal operation, and to automatically decouple from it and sink to the PCM whenever structural temperatures are too high. The HP radiating panel is designed to conductively couple the panel feeder HPs directly to a fluid line that serves as a source of waste heat. It is a simple strap-on type of system that requires no internal or external line modifications to distribute the heat to a large radiating area.

Alario, J.↗

Analytic description of vibrations in a piping system with pulsating flow

Various calculation schemes were proposed for describing vibrations in a piping system with pulsating flow. Methods were selected and applied according to the type of irregularities examined: concentrated ones, extended ones, or complex ones. The selection of a method also depends on comparability of the extent of the irregularities with the pressure wavelength and velocity in the flow. Relations were found which permit a description of the interaction of a pulsating flow with any irregularity in the system. For complex systems with varying temperatures and some irregularities, relations were obtained, which reflect the varying phase displacement of the forces in these irregularities. The effect of the frictional torque on pipeline supports, in the presence of flexural and torsional vibrations was investigated, on the assumption that the frictional torque depends linearly on the angular velocity.

Bosnyatskiy, G. P.↗

Development of electrical feedback controlled heat pipes and the advanced thermal control flight experiment

The development and characteristics of electrical feedback controlled heat pipes (FCHP) are discussed. An analytical model was produced to describe the performance of the FCHP under steady state and transient conditions. An advanced thermal control flight experiment was designed to demonstrate the performance of the thermal control component in a space environment. The thermal control equipment was evaluated on the ATS-F satellite to provide performance data for the components and to act as a thermal control system which can be used to provide temperature stability of spacecraft components in future applications.

Bienert, W. B.↗

Pipe flow measurements of turbulence and ambiguity using laser-Doppler velocimetry

The laser-Doppler ambiguities predicted by George and Lumley (1973) have been verified experimentally for turbulent pipe flows. Experiments were performed at Reynolds numbers from 5000 to 15,000 at the center line and near the wall. Ambiguity levels were measured from power spectral densities of FM demodulated laser signals and were compared with calculations based on the theory. The turbulent spectra for these water flows after accounting for the ambiguity were equivalent to hot-film measurements at similar Reynolds numbers. The feasibility of laser-Doppler measurements very close to the wall in shear flows is demonstrated.

Berman, N. S.↗

Nonlinear gas oscillations in pipes. II - Experiment

The problem of forced acoustic oscillations in a pipe was experimentally investigated, taking into account the response of both open and closed tubes to near-resonant excitation by large amplitude oscillations of a piston at one end of the tube. Attention was given to the effect of the orifice area on shock waves. By comparing the experimental results with nonlinear theory, wave reflection coefficients of the orifice plates were determined at both closed-tube and open-tube resonant frequencies. This approach can even be used when the terminating elements are subjected to intense periodic pressure pulses.

Sturtevant, B.↗

Instabilities of a spatial system of articulated pipes conveying fluid

A spatial system of two articulated pipes conveying fluid is examined analytically and experimentally. As the flow rate is increased, stable equilibrium may be lost by either divergence (static buckling) or by flutter (oscillations with increasing amplitude), depending upon the value of an angle beta which measures the 'out-of-planeness' of the system. It is found that in the range O less than beta less than 90 deg there exists a transition value below which stability is lost by flutter and above which stability is lost by divergence.

Bohn, M. P.↗

Parametric performance of extruded axial grooved heat pipes from 100 to 300 K

Extensive performance data derived from tests with an aluminum axial grooved extruded heat pipe is presented for oxygen, methane, ethane, and ammonia as working fluids. The effects of operating temperature, fluid inventory, heat flux, and elevation on the transport capability and the evaporator and condenser film coefficients are measured and compared to theory. The data correlation indicates that, in addition to the viscous pressure drop of the fluid, a vapor induced liquid pressure drop must be taken into account at temperatures near or below the normal boiling point of the fluid. Methane, ethane, and ammonia are all suitable working fluids for this groove geometry; however, oxygen, because of its low static height, is at best marginal in the 100-120 K range.

Schlitt, K. R.↗

Large variable conductance heat pipe. Transverse header

The characteristics of gas-loaded, variable conductance heat pipes (VCHP) are discussed. The difficulties involved in developing a large VCHP header are analyzed. The construction of the large capacity VCHP is described. A research project to eliminate some of the problems involved in large capacity VCHP operation is explained.

Edelstein, F.↗

Steady-state and transient operation of a heat-pipe radiator system

Data obtained on a VCHP heat-pipe radiator system tested in a vacuum environment were studied. Analyses and interpretation of the steady-state results are presented along with an initial analysis of some of the transient data. Particular emphasis was placed on quantitative comparisons of the experimental data with computer model simulations. The results of the study provide a better understanding of the system but do not provide a complete explanation for the observed low VCHP performance and the relatively flat radiator panel temperature distribution. The results of the study also suggest hardware, software, and testing improvements.

Sellers, J. P.↗

Flat-plate /vapor-chamber/ heat pipes

This paper discusses the design, fabrication and testing of heat pipes constructed in the form of flat-plate panels. The test panels were constructed of copper with methyl alcohol as the working fluid. Capillary grooves etched on the internal surfaces provided evaporation and condensation heat-transfer coefficients on the order of 1600 Btu/hr-sq ft-deg F. Two panels were launched on board a sounding rocket; the payload reached an altitude of 140 miles, and zero gravity was achieved for almost six minutes. The panel with working fluid inside demonstrated a heat input flux of 2.5 watts/sq cm, with only a 3 to 5 C temperature difference throughout the entire panel.

Fleischman, G. L.↗