Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EPC-ES WIPP WAC Appendix A Equivalence Support Measurements 2019-2020

Characterization of low-level waste (LLW) at Los Alamos National Laboratory (LANL) is primarily performed by the Environmental Protection and Compliance - Environmental Stewardship (EPC-ES) Characterization Services team and/or the Nuclear Process Infrastructure (NPI--9) Nuclear Material Support Services team (hereafter referred to as the gamma spectroscopy teams). The gamma spectroscopy teams use portable high-purity germanium (HPGe) detector systems for the nondestructive assay (NDA) characterization of LLW. Controlled-approved procedures and processes for the use of such systems to assay LLW items are currently in place. Additionally, a number of performance studies have been conducted by the gamma spectroscopy teams to support the efficacy and quality of assay results generated by the established NDA process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Tube dimpling tool assures accurate dip-brazed joints

Portable, hand-held dimpling tool assures accurate brazed joints between tubes of different diameters. Prior to brazing, the tool performs precise dimpling and nipple forming and also provides control and accurate measuring of the height of nipples and depth of dimples so formed.

Beuyukian, C. S.↗

Display management subsystem, version 1: A user's eye view

The structure and application functions of the Display Management Subsystem (DMS) are described. The DMS, a subsystem of the Transportable Applications Executive (TAE), was designed to provide a device-independent interface for an image processing and display environment. The system is callable by C and FORTRAN applications, portable to accommodate different image analysis terminals, and easily expandable to meet local needs. Generic applications are also available for performing many image processing tasks.

Parker, Dolores↗

Development Requirements for the Exploration PLSS (xPLSS) Carbon Dioxide and Humidity Control Unit (CDHCU)

Functional Requirements for the Carbon Dioxide and Humidity Control Unit (CDHCU): The CDHCU is a component of the Exploration Portable Life Support System (xPLSS) to provide carbon dioxide (CO2) and humidity control within the spacesuit for a crewmember to perform extravehicular activities (EVA) in vacuum (micro-g), lunar, and Mars environments for up to 8 hours continuous, and during EVA preparation in airlocks or support vehicles for an additional 2 hours (TBR) continuous.

Chullen, Cinda↗

SERFE Water Quality Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. Water quality, and how that impacts the performance of the life support system hardware, are areas where improvements could greatly help to achieve these goals. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. This paper will summarize the results of the water quality analysis performed to date throughout the SERFE testing program. Special care was taken to select materials, process hardware, and control the quality of the feedwater used in SERFE testing so that it would be representative of a thermal control system that could be used on a spacesuit for a lunar mission. In addition, the testing schedule, including periods of quiescence in between tests, was also selected to simulate a real mission profile in ways that would be critical to water quality. Results include data and analysis on microbial activity, biocidal iodine, metals, organic carbon, and several other customary indicators of water quality in an operational system. Testing spans over a year and a half of wetted life of the SERFE Flight Unit and the SERFE Ground Unit.

Colin Campbell↗

Plutonium Detection with Straw Neutron Detectors

A kilogram of weapons grade plutonium gives off about 56,000 neutrons per second of which 55,000 neutrons come from spontaneous fission of 240Pu (~6% by weight of the total plutonium). Actually, all even numbered isotopes (238Pu, 240Pu, and 242Pu) produce copious spontaneous fission neutrons. These neutrons induce fission in the surrounding fissile 239Pu with an approximate multiplication of a factor of ~1.9. This multiplication depends on the shape of the fissile materials and the surrounding material. These neutrons (typically of energy 2 MeV and air scattering mean free path >100 meters) can be detected 100 meters away from the source by vehicle-portable neutron detectors. [1] In our current studies on neutron detection techniques, without using 3He gas proportional counters, we designed and developed a portable high-efficiency neutron multiplicity counter using 10B-coated thin tubes called straws. The detector was designed to perform like commercially available fission meters (manufactured by Ortec Corp.) except instead of using 3He gas as a neutron conversion material, we used a thin coating of 10B.

plutonium, neutron, straw↗

SPEChpc 2021 Benchmark Suites for Modern HPC Systems

The SPEChpc 2021 suites are application-based benchmarks de- signed to measure performance of modern HPC systems. The bench- marks support MPI, MPI+OpenMP, MPI+OpenMP target offload, MPI+OpenACC and are portable across all major HPC platforms.

Boehm, Swen↗

Application of the PHDS Germanium Gamma-ray Imager (GeGI) in Facility Decontamination Assessment - 19471

As part of a site wide investigation, U.S. EPA Region 5 had to assess the nature and extent of contamination in a former radioactive source manufacturing facility. This work involved verification of the radioisotope expected, ensuring no other radioisotopes were present, and quantification of the activity and areal extent of contamination throughout the facility. The device used to support this assessment work was the Germanium Gamma-ray Imager (GeGI) manufactured by PHDS Co. of Knoxville, Tennessee. GeGI is a germanium-semiconductor imaging detector system that provides identification, location, and quantification of radioactive materials within its field of view. GeGI provides the highest fidelity radiological assay information including the best gamma-ray energy resolution and spatial localization of any existing technology, including gamma-ray energy resolution of ∼0.3% full-width half-max (FWHM) at 662 keV and angular location resolution ∼ +/-1 degree. The GeGI is a mechanically cooled, portable system well-suited to field operations. PHDS Co. also provided on-site support during assessment operations and performed subsequent data analysis. Gamma-ray spectral data and associated images were collected with GeGI in six primary areas of the facility having significant residual contamination. A total of 61 gamma-ray spectrum/image sets were collected over the course of three working days (22 Compton images and 39 Pinhole/Compton images). During data collection, Compton imaging was used as the means by which to identify and prioritize hotspots. After contaminated regions were identified via Compton imaging, short-distance Pinhole spectrum/image sets were collected for additional analysis. All of the spectrum/image sets were analyzed to determine the radioisotope distribution within the GeGI field of view, as well as to provide an estimate of the activity associated with each hotspot. It was determined that the nature of residual contamination present was distributed across specific areas of elevated activity, where in some areas there was significant accumulation of contaminated material. It was also determined that no discrete sources of high-activity were present, as would be expected in the case of radioactive material product intended for sealed source manufacture. Results included the activity of residual contamination for each of the areas assessed, and an estimate of the physical area over which that contamination was distributed. It was anticipated by EPA that if decontamination were to be performed that it would involve some type of concrete scabbling or other means of physical removal of contaminated material. The GeGI data could be used to estimate the areal extent (square footage) of concrete removal that would be required for decontamination. Using the activity estimate data from the GeGI along with an estimated depth of concrete removal, planning could be performed for decontamination work (equipment and personnel), waste collection, packaging, transportation, and disposal, along with an associated cost estimate. With regard to health and safety, use of the GeGI reduced the radiation dose to the EPA R5 staff performing the assessment work. The GeGI is a non-destructive device that supports assessment of radioactively contaminated areas and sources from a distance, reducing the need for close contact to radiation, and the time necessary for personnel to operate near such hazards. Use of the GeGI in this facility assessment was our first attempt to apply this technology in what proved to be a quick and efficient decontamination assessment method. The GeGI can assess the nature and extent of residual contamination in a facility, first by quickly identifying the areas of elevated activity, followed by refined measurement and assessment of those elevated areas. The GeGI data can then be used to develop planning and a cost estimate of required decontamination and waste management activities. Since it's a non-destructive gamma identification and imaging device, it can reduce the distance of workers from radioactive sources and the dose incurred from assessment work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Low-cost, Risk-Reduction Testing of Class D Spacecraft Photovoltaic Systems

The end-to-end verification of a spacecraft photovoltaic power generation system requires light! A low-cost, portable, and end-to-end photovoltaic-system test appropriate for NASAs new generation of Class D missions is presented. High risk, low-cost, and quick-turn satellites rarely have the resources to execute the traditional approaches from higher-class (A-C) missions. The Class D approach, as demonstrated on the Lunar Atmospheric and Dust Environment Explorer (LADEE), utilizes a portable, metal-halide, theatre lamp for an end-to-end photovoltaic system test. While not as precise and comprehensive as the traditional Large Area Pulsed Solar Simulator (LAPSS) test, the LADEE method leverages minimal resources into an ongoing assessment program that can be applied through numerous stages of the mission. The project takes a true Class D approach in assessing the technical value of a costly, high-fidelity performance test versus a simpler approach with less programmatic risk. The resources required are a fraction of that for a LAPSS test, and is easy to repeat due to its portability. Further, the test equipment can be handed down to future projects without building an on-site facility.At the vanguard of Class D missions, the LADEE team frequently wrestled with and challenged the status quo. The philosophy of risk avoidance at all cost, typical to Class A-C missions, simply could not be executed. This innovative and simple testing solution is contextualized to NASA Class D programs and a specific risk encountered during development of the LADEE Electrical Power System (EPS). Selection of the appropriate lamp and safety concerns are discussed, with examples of test results. Combined with the vendors panel-level data and periodic inspection, the method ensures system integrity from Integration and Test (IT) through launch. Following launch, mission operations tools are utilized to assess system performance based on a scant amount of available data.

photovoltaic↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

EFFECT OF FUEL IMPURITIES ON FUEL CELL PERFORMANCE AND DURABILITY

A fuel cell is an electrochemical energy conversion device that produces electricity during the combination of hydrogen and oxygen to produce water. Proton exchange membranes fuel cells are favored for portable applications as well as stationary ones due to their high power density, low operating temperature, and low corrosion of components. In real life operation, the use of pure fuel and oxidant gases results in an impractical system. A more realistic and cost efficient approach is the use of air as an oxidant gas and hydrogen from hydrogen carriers (i.e., ammonia, hydrocarbons, hydrides). However, trace impurities arising from different hydrogen sources and production increases the degradation of the fuel cell. These impurities include carbon monoxide, ammonia, sulfur, hydrocarbons, and halogen compounds. The International Organization for Standardization (ISO) has set maximum limits for trace impurities in the hydrogen stream; however fuel cell data is needed to validate the assumption that at those levels the impurities will cause no degradation. This report summarizes the effect of selected contaminants tested at SRNL at ISO levels. Runs at ISO proposed concentration levels show that model hydrocarbon compound such as tetrahydrofuran can cause serious degradation. However, the degradation is only temporary as when the impurity is removed from the hydrogen stream the performance completely recovers. Other molecules at the ISO concentration levels such as ammonia don't show effects on the fuel cell performance. On the other hand carbon monoxide and perchloroethylene shows major degradation and the system can only be recovered by following recovery procedures.

08 HYDROGEN↗

Compiler and Runtime Approaches to Enable Large-Scale Irregular Programs. Final report, July 2013 - July 2019

While regular algorithms, characterized by operations on dense matrices and arrays, have long been the mainstay of scientific, high-performance computing, irregular algorithms, which feature unpredictable accesses to pointer-based data structures, are becoming increasingly common in high performance computing, arising in graph analysis, data mining and visualization, among other domains. Unfortunately, the defining characteristics of irregular applications, their dynamic, unpredictable, data-dependent access patterns and data layouts, make achieving high performance on large scale systems difficult. Scaling applications to peta- and exa-scale requires carefully controlling communication and data movement and placement, an inherently difficult task when access patterns and data layouts are unpredictable! Most irregular applications that attain high performance must be painstakingly hand-written and hand-tuned, with few common principles or paradigms uniting various implementations and easing future development. Despite the increasing importance of irregular applications, there is little programmer knowledge, and even less compiler ability, devoted to optimizing them. This project aims to solve these problems. By allowing programmers to write irregular applications in high level forms, with at most a few annotations highlighting key structural properties, programmers can focus on developing their algorithms and methods. The compiler and run-time system can take on the tedious task of optimizing the application for execution at large scales, and can automatically provide efficient implementations. This will provide portability and ease maintenance for existing irregular applications, but, more importantly, open up whole new domains of computational science to large-scale, high-performance simulation codes.

97 MATHEMATICS AND COMPUTING↗

Low-Power CO2 Compression Technology

Presently, the most feasible processes for extracting oxygen from the Martian atmosphere either require or are much more efficient if the atmospheric CO2 feed is provided at pressures well above the Martian ambient. Electrical power for performing the desired compression is likely to be an extremely limited resource on the Mars surface. Even if "cheap" nuclear power is available at a central site/launch facility where rocket propellent and oxidant are manufactured, life support applications needing oxygen production capabilities, such as rovers, portable life support, and remote or independent exploration stations, will benefit from extremely low-power atmospheric compression technology, such as the one discussed here. Our experiments show the potential of one very low-power approach to performing CO2 compression that uses the Mars diurnal temperature cycle to drive a heat engine. The 1 kg compressor has been tested over an extended period in a Mars environmental simulation chamber that mimics the composition, pressure, and temperature cycles that can occur on the Martian surface. The simple design, which has very few moving parts and can easily be scaled to larger or smaller sizes, produces a CO2 stream at a rate of 100 g/ day at a quality and pressure suitable for a variety of oxygen production processes.

Finn, John E.↗

Automatic Generation of OpenMP Directives and Its Application to Computational Fluid Dynamics Codes

The shared-memory programming model is a very effective way to achieve parallelism on shared memory parallel computers. As great progress was made in hardware and software technologies, performance of parallel programs with compiler directives has demonstrated large improvement. The introduction of OpenMP directives, the industrial standard for shared-memory programming, has minimized the issue of portability. In this study, we have extended CAPTools, a computer-aided parallelization toolkit, to automatically generate OpenMP-based parallel programs with nominal user assistance. We outline techniques used in the implementation of the tool and discuss the application of this tool on the NAS Parallel Benchmarks and several computational fluid dynamics codes. This work demonstrates the great potential of using the tool to quickly port parallel programs and also achieve good performance that exceeds some of the commercial tools.

Yan, Jerry↗

Managing genomic variant calling workflows with Swift/T

Bioinformatics research is frequently performed using complex workflows with multiple steps, fans, merges, and conditionals. This complexity makes management of the workflow difficult on a computer cluster, especially when running in parallel on large batches of data: hundreds or thousands of samples at a time. Scientific workflow management systems could help with that. Many are now being proposed, but is there yet the “best” workflow management system for bioinformatics? Such a system would need to satisfy numerous, sometimes conflicting requirements: from ease of use, to seamless deployment at peta- and exa-scale, and portability to the cloud. We evaluated Swift/T as a candidate for such role by implementing a primary genomic variant calling workflow in the Swift/T language, focusing on workflow management, performance and scalability issues that arise from production-grade big data genomic analyses. In the process we introduced novel features into the language, which are now part of its open repository. Additionally, we formalized a set of design criteria for quality, robust, maintainable workflows that must function at-scale in a production setting, such as a large genomic sequencing facility or a major hospital system. The use of Swift/T conveys two key advantages. (1) It operates transparently in multiple cluster scheduling environments (PBS Torque, SLURM, Cray aprun environment, etc.), thus a single workflow is trivially portable across numerous clusters. (2) The leaf functions of Swift/T permit developers to easily swap executables in and out of the workflow, which makes it easy to maintain and to request resources optimal for each stage of the pipeline. While Swift/T’s data-level parallelism eliminates the need to code parallel analysis of multiple samples, it does make debugging more difficult, as is common for implicitly parallel code. Nonetheless, the language gives users a powerful and portable way to scale up analyses in many computing architectures.

Science & Technology - Other Topics↗