Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Accelerating x-ray tracing for exascale systems using Kokkos

The upcoming exascale computing systems Frontier and Aurora will draw much of their computing power from GPU accelerators. The hardware for these systems will be provided by AMD and Intel, respectively, each supporting their own GPU programming model. The challenge for applications that harness one of these exascale systems will be to avoid lock-in and to preserve performance portability. We report here on our results of using Kokkos to accelerate a real-world application on NERSC's Perlmutter Phase 1 (using NVIDIA A100 accelerators) and Crusher, the testbed system for OLCF's Frontier (using AMD MI250X). By porting to Kokkos, we successfully ran the same X-ray tracing code on both systems and achieved speed-ups between 13 % and 66 % compared to the original CUDA code. Finally, these results are a highly encouraging demonstration of using Kokkos to accelerate production science code.

97 MATHEMATICS AND COMPUTING↗

Self-Assembly of Large Gold Nanoparticles for Surface-Enhanced Raman Spectroscopy

Performance of portable technologies from mobile phones to electric vehicles is currently limited by the energy density and lifetime of lithium batteries. Expanding the limits of battery technology requires in situ detection of trace components at electrode–electrolyte interphases. Surface-enhance Raman spectroscopy could satisfy this need if a robust and reproducible substrate were available. Gold nanoparticles (Au NPs) larger than 20 nm diameter are expected to greatly enhance Raman intensity if they can be assembled into ordered monolayers. A three-phase self-assembly method is presented that successfully results in ordered Au NP monolayers for particle diameters ranging from 13 to 90 nm. The monolayer structure and Raman enhancement factors (EFs) are reported for a model analyte, rhodamine, as well as the best performing polymer electrolyte salt, lithium bis(trifluoromethane)sulfonimide. Experimental EFs for the most part correlate with predictions based on monolayer geometry and with numerical simulations that identify local electromagnetic field enhancements. Lastly, the EFs for the best performing Au NP monolayer are between 10 6 and 10 8 and give quantitative signal response when analyte concentration is changed.

36 MATERIALS SCIENCE↗

SU-E-J-60: Efficient Monte Carlo Dose Calculation On CPU-GPU Heterogeneous Systems

Purpose: It is well-known that the performance of GPU-based Monte Carlo dose calculation implementations is bounded by memory bandwidth. One major cause of this bottleneck is the random memory writing patterns in dose deposition, which leads to several memory efficiency issues on GPU such as un-coalesced writing and atomic operations. We propose a new method to alleviate such issues on CPU-GPU heterogeneous systems, which achieves overall performance improvement for Monte Carlo dose calculation. Methods: Dose deposition is to accumulate dose into the voxels of a dose volume along the trajectories of radiation rays. Our idea is to partition this procedure into the following three steps, which are fine-tuned for CPU or GPU: (1) each GPU thread writes dose results with location information to a buffer on GPU memory, which achieves fully-coalesced and atomic-free memory transactions; (2) the dose results in the buffer are transferred to CPU memory; (3) the dose volume is constructed from the dose buffer on CPU. We organize the processing of all radiation rays into streams. Since the steps within a stream use different hardware resources (i.e., GPU, DMA, CPU), we can overlap the execution of these steps for different streams by pipelining. Results: We evaluated our method using a Monte Carlo Convolution Superposition (MCCS) program and tested our implementation for various clinical cases on a heterogeneous system containing an Intel i7 quad-core CPU and an NVIDIA TITAN GPU. Comparing with a straightforward MCCS implementation on the same system (using both CPU and GPU for radiation ray tracing), our method gained 2-5X speedup without losing dose calculation accuracy. Conclusion: The results show that our new method improves the effective memory bandwidth and overall performance for MCCS on the CPU-GPU systems. Our proposed method can also be applied to accelerate other Monte Carlo dose calculation approaches. This research was supported in part by NSF under Grants CCF-1217906, and also in part by a research contract from the Sandia National Laboratories.

60 APPLIED LIFE SCIENCES↗

Accelerating laser ray tracing in high fidelity physics simulations of laser melting using squeeze U-net

Laser melting is a core component of the ongoing industrial revolution, dubbed Industry 4.0, as lasers facilitate fast and precise melting and fusion in advanced manufacturing. There is a strong need to optimize the laser process using simulations. However, this has proven challenging as high fidelity simulations are needed for predictive modeling and this is currently prohibitively expensive even when run on hundreds of processors on high performance computers. The challenge is capturing complex physics of laser material interaction, fluid dynamics, thermal physics and material phase transformations at various length and time scales. To close this technological gap, we modified a squeeze U-net to accelerate the laser ray tracing component of such high fidelity models by ~4x–40x while preserving the core physics principle of conservation of energy with 97% accuracy. This approach enables the accurate modeling of global laser energy absorption as a function of local surface temperatures and complex surface topologies, which govern the reflection directions and energy losses of laser rays upon interacting with the material surface.

Computer science↗

Bioelectrochemical Immunoassay of Polychlorinated Biphenyl

A simple, rapid, and highly sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) and disposable screen-printed electrodes (SPE) has been developed to detect polychlorinated biphenyls (PCBs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PCB-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PCB (HRP-PCB). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreactions among PCB-antibody-coated MBs, PCB analyte, and HRP-PCB. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing o-aminophenol and hydrogen peroxide for electrochemical detection. The different parameters, including the amount of HRP-PCB conjugates, immunoreaction time, and the concentration of substrate that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 5 pg mL-1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical immunoassay was successfully evaluated with untreated river water spiked with PCBs, and the results were validated by commercial PCB enzyme-linked immunosorbent assay kit, indicating that this convenient and sensitive technique offers great promise for decentralized environmental application and trace PCBs monitoring.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Sorbent-Based Process for High Temperature Trace Metal Removal

The objective of this project was to demonstrate the efficacy of a novel sorbent can effectively remove trace metal contaminants (Hg, As, Se and Cd) from actual coal-derived synthesis gas streams at high temperature (above the dew point of the gas). The performance of TDA's sorbent has been evaluated in several field demonstrations using synthesis gas generated by laboratory and pilot-scale coal gasifiers in a state-of-the-art test skid that houses the absorbent and all auxiliary equipment for monitoring and data logging of critical operating parameters. The test skid was originally designed to treat 10,000 SCFH gas at 250 psig and 350 C, however, because of the limited gas handling capabilities of the test sites, the capacity was downsized to 500 SCFH gas flow. As part of the test program, we carried out four demonstrations at two different sites using the synthesis gas generated by the gasification of various lignites and a bituminous coal. Two of these tests were conducted at the Power Systems Demonstration Facility (PSDF) in Wilsonville, Alabama; a Falkirk (North Dakota) lignite and a high sodium lignite (the PSDF operator Southern Company did not disclose the source of this lignite) were used as the feedstock. We also carried out two other demonstrations in collaboration with the University of North Dakota Energy Environmental Research Center (UNDEERC) using synthesis gas slipstreams generated by the gasification of Sufco (Utah) bituminous coal and Oak Hills (Texas) lignite. In the PSDF tests, we showed successful operation of the test system at the conditions of interest and showed the efficacy of sorbent in removing the mercury from synthesis gas. In Test Campaign No.1, TDA sorbent reduced Hg concentration of the synthesis gas to less than 5 {micro}g/m{sup 3} and achieved over 99% Hg removal efficiency for the entire test duration. Unfortunately, due to the relatively low concentration of the trace metals in the lignite feed and as a result of the intermittent operation of the PSDF gasifier (due to the difficulties in the handling of the low quality lignite), only a small fraction of the sorbent capacity was utilized (we measured a mercury capacity of 3.27 mg/kg, which is only a fraction of the 680 mg/kg Hg capacity measured for the same sorbent used at our bench-scale evaluations at TDA). Post reaction examination of the sorbent by chemical analysis also indicated some removal As and Se (we did not detect any significant amounts of Cd in the synthesis gas or over the sorbent). The tests at UNDEERC was more successful and showed clearly that the TDA sorbent can effectively remove Hg and other trace metals (As and Se) at high temperature. The on-line gas measurements carried out by TDA and UNDEERC separately showed that TDA sorbent can achieve greater than 95% Hg removal efficiency at 260 C ({approx}200g sorbent treated more than 15,000 SCF synthesis gas). Chemical analysis conducted following the tests also showed modest amounts of As and Se accumulation in the sorbent bed (the test durations were still short to show higher capacities to these contaminants). We also evaluated the stability of the sorbent and the fate of mercury (the most volatile and unstable of the trace metal compounds). The Synthetic Ground Water Leaching Procedure Test carried out by an independent environmental laboratory showed that the mercury will remain on the sorbent once the sorbent is disposed. Based on a preliminary engineering and cost analysis, TDA estimated the cost of mercury removal from coal-derived synthesis gas as $2,995/lb (this analysis assumes that this cost also includes the cost of removal of all other trace metal contaminants). The projected cost will result in a small increase (less than 1%) in the cost of energy.

01 COAL, LIGNITE, AND PEAT↗

Methodology for the Design of Streamline-Traced External-Compression Supersonic Inlets

A design methodology based on streamline-tracing is discussed for the design of external-compression, supersonic inlets for flight below Mach 2.0. The methodology establishes a supersonic compression surface and capture cross-section by tracing streamlines through an axisymmetric Busemann flowfield. The compression system of shock and Mach waves is altered through modifications to the leading edge and shoulder of the compression surface. An external terminal shock is established to create subsonic flow which is diffused in the subsonic diffuser. The design methodology was implemented into the SUPIN inlet design tool. SUPIN uses specified design factors to design the inlets and computes the inlet performance, which includes the flow rates, total pressure recovery, and wave drag. A design study was conducted using SUPIN and the Wind-US computational fluid dynamics code to design and analyze the properties of two streamline-traced, external-compression (STEX) supersonic inlets for Mach 1.6 freestream conditions. The STEX inlets were compared to axisymmetric pitot, two-dimensional, and axisymmetric spike inlets. The STEX inlets had slightly lower total pressure recovery and higher levels of total pressure distortion than the axisymmetric spike inlet. The cowl wave drag coefficients of the STEX inlets were 20% of those for the axisymmetric spike inlet. The STEX inlets had external sound pressures that were 37% of those of the axisymmetric spike inlet, which may result in lower adverse sonic boom characteristics. The flexibility of the shape of the capture cross-section may result in benefits for the integration of STEX inlets with aircraft.

Metholdology↗

TRACE/PARCS modelling of rips trip transients for Lungmen ABWR

The objectives of this study are to examine the performances of the steady-state results calculated by the Lungmen TRACE/PARCS model compared to SIMULATE-3 code, as well as to use the analytical results of the final safety analysis report (FSAR) to benchmark the Lungmen TRACE/PARCS model. In this study, three power generation methods in TRACE were utilized to analyze the three reactor internal pumps (RIPs) trip transient for the purpose of validating the TRACE/PARCS model. In general, the comparisons show that the transient responses of key system parameters agree well with the FSAR results, including core power, core inlet flow, reactivity, etc. Further studies will be performed in the future using Lungmen TRACE/PARCS model. After the commercial operation of Lungmen nuclear power plant, TRACE/PARCS model will be verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hierarchical Defect Engineering for LiCoO 2 through Low-Solubility Trace Element Doping

Real-world industry-relevant battery composite electrodes are hierarchically structured. Their structural and chemical complexity is featured by ubiquitous multi-scale porosity and cracks, solid-solid and solid-liquid interfaces, compositional and redox heterogeneity, as well as lattice disordering and deformation. In particular for the active cathode particles, which are the fundamental building blocks for the energy reservoir, it is a consensus that these structural and chemical defects could have a profound impact on the battery performance. An in-depth understanding of the underlying mechanisms could critically inform the cathode material engineering, which would have a tremendous potential but remains a daunting challenge at present. In this work, we tackle this question by studying LiCoO 2 (LCO) with trace doping of Ti, which exhibits a low solubility in the LCO layered lattice. Additionally, we observed the spontaneous and heterogeneous segregation of the dopant (Ti) across a wide range of length scales. In addition to the modification of the particle surface and the buried grain boundaries within the particle, we reveal that the Ti doping has induced a significant amount of lattice distortions, which, in turn, promotes the robustness of the LCO lattice at high state of charge (above 4.5V). Our result formulates a multi-scale defect engineering strategy that could be applicable to the synthesis of a broad range of energy materials for applications in batteries and beyond.

36 MATERIALS SCIENCE↗

Effect of Nickel-Phosphorus Interactions on Structural Integrity of Anode-Supported Solid Oxide Fuel Cells

An integrated experimental/modeling approach was utilized to assess the structural integrity of Ni - yttria-stabilized zirconia (YSZ) porous anode supports followed the solid oxide fuel cell (SOFC) operation on coal gas containing trace amounts of phosphorus impurities. Phosphorus was chosen as a typical impurity exhibiting strong interactions with the nickel followed by second phase formation. Tests were performed using Ni-YSZ anode-supported button cells exposed to 0.5-10 ppm of phosphine in synthetic coal gas at 700-800oC. The extent of Ni-P interactions was determined by a post-test scanning electron microscopy (SEM) analysis. Severe damage to the anode support due to nickel phosphide phase formation and extensive crystal coalescence was revealed, resulting in electric percolation loss. The subsequent finite element stress analyses were conducted using the actual anode support microstructures to assist in degradation mechanism explanation. Volume expansion induced by the Ni phase alteration was found to produce high stress levels such that local failure of the Ni-YSZ anode became possible under the operating conditions. These results emphasize the need for extensive coal gas cleanup when used as a fuel for SOFCs.

coal gas impurity↗

Examination of the distribution of the tensile deformation systems in tension and tension-creep of Ti-6Al-4V (wt.%) at 296 K and 728 K

The deformation behaviour of an α + β Ti–6Al–4V (wt.%) alloy was investigated during in situ deformation inside a scanning electron microscopy (SEM). Tensile experiments were performed at 296 and 728 K (~0.4Tm), while a tensile-creep experiment was performed at 728 K and 310 MPa (σ/σ ys = 0.74). The active deformation systems were identified using electron backscattered diffraction-based slip-trace analysis and SEM images of the specimen surface. The distribution of the active deformation systems varied as a function of temperature. Basal slip deformation played a major role in the tensile deformation behaviour, and the relative activity of basal slip increased with increasing temperature. For the 296 K tension deformation, basal slip was less active than prismatic slip, whereas this was reversed at 728 K. Twinning was observed in both the 296 and 728 K tension experiments; however, no more than 4% of the total deformation systems observed was twins. The tension-creep experiment revealed no slip traces, however grain boundary ledge formation was observed, suggesting that grain boundary sliding was an active deformation mechanism. The results of this work were compared with those from previous studies on commercially pure Ti, Ti–5Al–2.5Sn (wt.%) and Ti–8Al–1Mo–1V (wt.%), and the effects of alloying on the deformation behaviour are discussed. Here, the relative amount of basal slip activity increased with increasing Al content.

36 MATERIALS SCIENCE↗

M-BAND SPECTRA OF DUST-EMBEDDED SOURCES AT THE GALACTIC CENTER

The goal of the present paper is to investigate the circumstellar material around the brightest dust-enshrouded sources in the central stellar cluster of the Milky Way. Observations have been carried out at the European Southern Observatory's Very Large Telescope (VLT) on Paranal, Chile. We have used the long wavelength (LWS3) low resolution (LR) spectroscopic mode of the ISAAC camera at the VLT in the spectral range of the M filter from 4.4 {mu}m to 5.1 {mu}m. The use of a slit width of 0.''6 implied a spectral resolution of R = lambda/DELTAlambda = 800 (DELTAv = 375 km s{sup -1}). These observations resulted in the M-band spectra of 15 bright sources in the central stellar cluster of the Milky Way. In addition to gaseous {sup 12}CO (4.666 {mu}m) and {sup 13}CO (4.77 {mu}m) vibration-rotational absorptions, we detect a strong absorption due to a mixture of polar and apolar CO ice (centered at 4.675 {mu}m). In the shorter wavelength absorption wing there is an absorption feature due to XCN at 4.62 {mu}m. The XCN absorption is strongest toward the M2 supergiant IRS 7. We find that the extinctions due to material traced by the CO ice and the CO gas absorptions may be of comparable importance. Using the spectra of IRS 2L and IRS 16C, we perform a first order correction of the line-of-sight absorption due to CO ice and {sup 13}CO gas. In combination with published hydrogen number density estimates from sub-millimeter CO(7-6) and FIR [O I] line data, we obtain gas masses of the circumstellar shells of the order of 10{sup -3} and 10{sup -2} M {sub sun}. This implies that in future spectra taken at high spectral and angular resolution the bright and dust-embedded Galactic center sources should show a substantial line absorption due to source intrinsic absorption.

79 ASTRONOMY AND ASTROPHYSICS↗

Tank 241-AN-107 Study for Semi-Volatile Organics in 2017 Grab Samples and Carbonation of Composite for Solids Precipitation and Caustic Demand

Tank 241-AN-107 waste is known to contain high concentrations of complexing organics, and caustic sodium hydroxide has been added due to depleted free hydroxide in the waste. Eight grab samples were taken in August 2017 for routine chemical analyses. Investigations of the tank’s organic contents and solids precipitation at lower pH levels by CO 2 gas, as well as the performance of caustic demand testing at lower pH ranges were examined. Sub-micron particles were visible, suspended in the supernate, using scanning electron microscopy. Trace amounts of precipitation floating on the surface of the supernate were observed and were collected with the surface liquid samples for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing the contribution of bioaerosols diversity from complex aerosol particle samples.

Current global change scenarios expect to significantly increase the contribution of pollen to the total organic aerosol budget. In addition, pollen can burst into smaller fragments that are highly efficient as cloud condensation nuclei. However, current climate models still do not incorporate the effects of these particles due to detection and quantification challenges in complex aerosol mixtures. Chemical biomarkers (i.e. fructose) have commonly been used to trace pollen but this approximation can generate false positive results given the large number of shared compounds between different bioaerosols. A previous pilot EMSL experiment performed on pure pollen samples suggested that using a set of metabolites as a fingerprint of bioaerosols could serve to substantially increase detection accuracy over single biomarker approaches. In this proposal we developed novel bioinformatic strategies to characterize and quantify complex pollen mixtures present in the atmosphere. For that, we used diverse machine learning algorithms to analyze metabolic fingerprints from complex mixtures of different pollen acquired with high-resolution mass spectrometry (Orbitrap Q-Exactive). Our preliminary results demonstrated the potential to accurately discern and identify at specific relative abundances different pollen species in complex mixtures. Our research will lead to a significant advancement in the atmospheric chemistry and provide much needed data to improve the accuracy of climate models.

54 ENVIRONMENTAL SCIENCES↗

LLE Review Volume 115 (April-June 2008)

This volume of the LLE Review, covering April–June 2008, features “Development and Demonstration of Large-Aperture, Tiled-Grating Compressors for the OMEGA EP Petawatt-Class Laser System” by J. Qiao, A. Kalb, D. Canning, T. Nguyen, J. Bunkenburg, and J. H. Kelly. In this article (p. 113), the authors report on the OMEGA EP effort regarding the two large-aperture tiled-grating (1.5-m) compressors. Each compressor, consisting of four sets of tiled-grating assemblies, has been built for the OMEGA EP High-Energy, Petawatt-Class Laser System. The techniques used for tiling individual tiled-grating assemblies and for optimizing the overall performance of a tiled-grating compressor are described. Both compressors achieved subpicosecond-pulse duration without tiling-induced temporal degradation. A ray-tracing model predicted that the static wavefront of the grating tiles dominated focal-spot degradations when submicroradian tiling accuracy is achieved. The tiled-grating compressors delivered a tighter focal spot compared to sub-aperture grating compressors with single central tiles.

42 ENGINEERING↗

Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)

The NASA New Millennium Program's Geostationary Imaging Fourier Transform Spectrometer (GIFTS) requires highly accurate radiometric and spectral calibration in order to carry out its mission to provide water vapor, wind, temperature, and trace gas profiling from geostationary orbit. A calibration concept has been developed for the GIFTS Phase A instrument design. The in-flight calibration is performed using views of two on-board blackbody sources along with cold space. A radiometric calibration uncertainty analysis has been developed and used to show that the expected performance for GIFTS exceeds its top level requirement to measure brightness temperature to better than 1 K. For the Phase A GIFTS design, the spectral calibration is established by the highly stable diode laser used as the reference for interferogram sampling, and verified with comparisons to atmospheric calculations.

Best, F. A.↗

MSL SAM-Like Evolved Gas Analyses of Si-rich Amorphous Materials

Chemical and mineralogical analyses of several samples from Murray Formation mudstones and Stimson Formation sandstones by the Mars Science Laboratory (MSL) revealed the presence of Si-rich amorphous or poorly ordered materials. It is possible to identify the presence of high-SiO2 vs. lower SiO2 amorphous materials (e.g., basaltic glasses), based on the position of the resulting wide diffraction features in XRD patterns from the Chemistry and Mineralogy (CheMin) instrument, but it is not possible to distinguish between several candidate high-SiO2 amorphous materials such as opal-A or rhyolitic glass. In the Buckskin (BS) sample from the upper Murray Formation, and the Big Sky (BY) and Greenhorn (GH) samples from the Stimson Formation, analyses by the Sample Analysis at Mars (SAM) instrument showed very broad H2O evolutions during sample heating at temperatures >450-500degC which had not been observed from previous samples. BS also had a significant broad evolution <450-500degC. We have undertaken a laboratory study targeted at understanding if the data from SAM can be used to place constraints on the nature of the amorphous phases. SAM-like evolved gas analyses have been performed on several opal and rhyolitic glass samples. Opal-A samples exhibited wide <500degC H2O evolutions, with lesser H2O evolved above ~500degC. H2O evolution traces from rhyolitic glasses varied, having either two broad H2O peaks, <300degC and >500degC, or a broad peak centered around 400degC. For samples that produced two evolutions, the lower temperature peak is more intense than the higher temperature peak, a trend also exhibited by opal-A. This trend is consistent with data from BS, but does not seem consistent with data from BY and GH which evolved most of their H2O >500degC. It may be that dehydration of opal-A and/or rhyolitic glass can result in some preferential loss of lower temperature H2O, to produce traces that more closely resemble BY and GH. This is currently under investigation and results will be reported.

McAdam, Amy↗

A Model-Based Systems Engineering Journey to Developing a Concept of Operations

Starting in 2017, NASA’s Human Research Program (HRP) Exploration Medical Capability (ExMC) element began a systems engineering transition from traditional, document-centric development to model-centric development when defining its foundation medical systems. These foundation medical systems define a Concept of Operations (ConOps) and identify the generic requirements for a medical system based on assumptions about a generic crew and mission environments and guidance from NASA standards (e.g., Medical “Levels of Care”). By making the transition, ExMC intends to improve communication among stakeholders about foundation medical system requirements and content. In addition, this transition will enable ExMC to lower both development and crew treatment risks for future, mission-specific medical systems. ExMC followed a Model Based Systems Engineering (MBSE) paradigm when developing the foundation medical systems. A model-based approach provides several advantages over a traditional, document-centric approach. First, when Systems Engineers (SE) develop diagrams in a model using a standard modeling language, they produce information dense pictures that facilitate understanding much more efficiently with less room for misinterpretation than text. Second, due to the evolving nature of projects, documentation becomes out of date the minute it is published. This can result in people making decisions based on information that is no longer current, especially if they are referencing a locally-stored copy of a document. A model, on the other hand, is always up to date with the latest approved changes and information. It serves as a single point of truth. Third, a model-centric approach centralizes all important information in one place. Rather than having to flip through separate ConOps documents, design specifications, requirements specifications, and the like to coordinate information, a model captures the content in one, integrated spot. This integration makes tracing information from end-to-end easier with greater reliability. The ExMC Systems Engineering Lifecycle follows a well-defined process. ExMC Systems Engineers perform all major steps of the process, regardless of the development methodology. One of the first steps in the process is developing the ConOps that describes the operation of the system from the point of view of the users. It includes a list of the users and their needs, the goals of the medical system, key assumptions about the system, and definitions of the medical system’s operational environments. For this development effort, ExMC chose to replace the traditional text-based ConOps document with a model. While the decision to change the development workflow was not difficult, implementing the structural and organizational workflows were. It required showing ExMC’s users, most of whom are not Systems Engineers, how the information they require would be presented in the model and to gain their acceptance of this approach. This paper documents key lessons learned during the ConOps transformation by focusing on how the model represents information, the agile workflow used by SEs when developing the model and how it integrates into a project plan, how leadership influenced key users to accept the transformation, and how the users interact with the model information.

Jeffrey Robert Cohen↗