Search NASA⌕ Search

SEARCH · Search NASA

Results for “Randomized methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

redMaPPer. I. Algorithm and SDSS DR8 catalog

We describe redMaPPer, a new red sequence cluster finder specifically designed to make optimal use of ongoing and near-future large photometric surveys. The algorithm has multiple attractive features: (1) it can iteratively self-train the red sequence model based on a minimal spectroscopic training sample, an important feature for high-redshift surveys. (2) It can handle complex masks with varying depth. (3) It produces cluster-appropriate random points to enable large-scale structure studies. (4) All clusters are assigned a full redshift probability distribution P(z). (5) Similarly, clusters can have multiple candidate central galaxies, each with corresponding centering probabilities. (6) The algorithm is parallel and numerically efficient: it can run a Dark Energy Survey-like catalog in ∼500 CPU hours. (7) The algorithm exhibits excellent photometric redshift performance, the richness estimates are tightly correlated with external mass proxies, and the completeness and purity of the corresponding catalogs are superb. We apply the redMaPPer algorithm to ∼10, 000 deg{sup 2} of SDSS DR8 data and present the resulting catalog of ∼25,000 clusters over the redshift range z in [0.08, 0.55]. The redMaPPer photometric redshifts are nearly Gaussian, with a scatter σ {sub z} ≈ 0.006 at z ≈ 0.1, increasing to σ {sub z} ≈ 0.02 at z ≈ 0.5 due to increased photometric noise near the survey limit. The median value for |Δz|/(1 + z) for the full sample is 0.006. The incidence of projection effects is low (≤5%). Detailed performance comparisons of the redMaPPer DR8 cluster catalog to X-ray and Sunyaev-Zel'dovich catalogs are presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficacy of Synbiotics to Reduce Acute Radiation Proctitis Symptoms and Improve Quality of Life: A Randomized, Double-Blind, Placebo-Controlled Pilot Trial

Purpose: To evaluate whether the daily intake of synbiotics interferes in radiation-induced acute proctitis symptoms and in quality of life in patients with prostate cancer. Methods and Materials: Twenty patients who underwent 3-dimensional conformal radiation therapy for prostate cancer were randomized to intake either a synbiotic powder containing Lactobacillus reuteri 10{sup 8} colony-forming units and 4.3 g of soluble fiber (Nestlé) or placebo. The questionnaire EORTC QLQ-PRT23 was applied before the beginning of radiation therapy and in every week for the first 4 weeks of treatment. The sum of both the complete (proctitis symptoms plus quality of life) and partial (proctitis symptoms) scores of the EORTC QLQ-PRT23 (European Organization for Research and Treatment of Cancer Quality of Life Module for Proctitis–23 items) questionnaire were the main endpoints. Results: This pilot study showed that the complete questionnaire score (median [range]) was higher in the second (23 [21-30] vs 26.5 [22-34], P<.05) and third (23 [21-32] vs 27.5 [24-33], P<.01) weeks in the placebo group. Proctitis symptoms were highest scored in the placebo group in both the second (19.5 [16-25]) and third (19 [17-24]) weeks than in the synbiotic group (week 2: 16.5 [15-20], P<.05; week 3: 17 [15-23], P<.01). In both scores the placebo group had a significantly higher result (P<.01) than the synbiotic group (repeated-measures analysis of variance). Conclusions: Synbiotics reduce proctitis symptoms and improve quality of life in radiation-induced acute proctitis during radiation therapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Approximability of Random-Hypergraph MAX-3-XORSAT Problems with Quantum Algorithms

Constraint satisfaction problems are an important area of computer science. Many of these problems are in the complexity class NP which is exponentially hard for all known methods, both for worst cases and often typical. Fundamentally, the lack of any guided local minimum escape method ensures the hardness of both exact and approximate optimization classically, but the intuitive mechanism for approximation hardness in quantum algorithms based on Hamiltonian time evolution is poorly understood. We explore this question using the prototypically hard MAX-3-XORSAT problem class. We conclude that the mechanisms for quantum exact and approximation hardness are fundamentally distinct. We qualitatively identify why traditional methods such as quantum adiabatic optimization are not good approximation algorithms. We propose a new spectral folding optimization method that does not suffer from these issues and study it analytically and numerically. We consider random rank-3 hypergraphs including extremal planted solution instances, where the ground state satisfies an anomalously high fraction of constraints compared to truly random problems. We show that, if we define the energy to be $E = N_{unsat}-N_{sat}$, then spectrally folded quantum optimization will return states with energy $E \leq A E_{GS}$ (where $E_{GS}$ is the ground state energy) in polynomial time, where conservatively, $A \simeq 0.6$. We thoroughly benchmark variations of spectrally folded quantum optimization for random classically approximation-hard (planted solution) instances in simulation, and find performance consistent with this prediction. We do not claim that this approximation guarantee holds for all possible hypergraphs, though our algorithm's mechanism can likely generalize widely. These results suggest that quantum computers are more powerful for approximate optimization than had been previously assumed.

Kapit, Eliot↗

Dynamic Response of a Semiactive Suspension System with Hysteretic Nonlinear Energy Sink Based on Random Excitation by means of Computer Simulation

This paper aims to investigate the property and behavior of the hysteretic nonlinear energy sink (HNES) coupled to a half vehicle system which is a nine-degree-of-freedom, nonlinear, and semiactive suspension system in order to improve the ride comfort and increase the stability in shock mitigation by using the computer simulation method. The HNES model is a semiactive suspension device, which comprises the famous Bouc–Wen (B-W) model employed to describe the force produced by both the purely hysteretic spring and linear elastic spring of potentially negative stiffness connected in parallel, for the half vehicle system. Nine nonlinear motion equations of the half vehicle system are derived in terms of the seven displacements and the two dimensionless hysteretic variables, which are integrated numerically by employing the direct time integration method for studying both the variables of vertical displacements, velocities, accelerations, chassis pitch angle, and the ride comfort and driver safety, respectively, based on the bump and random road inputs of the pseudoexcitation method as excitation signal. Simulation results show that, compared with the HNES model and the magnetorheological (MR) model coupled to the half vehicle system, the ride comfort and stability have been evidently improved. A successful validation process has been performed, which indicated that both the ride comfort and driver safety properties of the HNES model coupled to half vehicle significantly improved.

Chen, Hui↗

A novel low-rank matrix completion approach to estimate missing entries in Euclidean distance matrix

A Euclidean distance matrix (EDM) is a table of distance-square between points on a k-dimensional Euclidean space, with applications in many fields (e.g., engineering, geodesy, economics, genetics, biochemistry, and psychology). A problem that often arises is the absence (or uncertainty) of some EDM elements. In many situations, only a subset of all pairwise distances is available and it is desired to have some procedure to estimate the missing distances. In this paper, we address the problem of missing data in EDM through low-rank matrix completion techniques. We exploit the fact that the rank of a EDM is at most k+2 and does not depend on the number of points, which is, in general, much bigger then k. We use a singular value decomposition approach that considers the rank of the matrix to be completed and computes, in each iteration, a parameter that controls the convergence of the method. After performing a number of computational experiments, we could observe that our proposal was able to recover, with high precision, random EDMs with more than 1000 points and up to 98% of missing data in few minutes. In addition, our method required a smaller number of iterations when compared to other competitive state-of-art technique.

97 MATHEMATICS AND COMPUTING↗

SPECTROPOLARIMETRIC SIGNATURES OF CLUMPY SUPERNOVA EJECTA

Polarization has been detected at early times for all types of supernovae (SNe), indicating that all such systems result from or quickly develop some form of asymmetry. In addition, the detection of strong line polarization in SNe is suggestive of chemical inhomogeneities ('clumps') in the layers above the photosphere, which may reflect hydrodynamical instabilities during the explosion. We have developed a fast, flexible, approximate semi-analytic code for modeling polarized line radiative transfer within three-dimensional inhomogeneous rapidly expanding atmospheres. Given a range of model parameters, the code generates random sets of clumps in the expanding ejecta and calculates the emergent line profile and Stokes parameters for each configuration. The ensemble of these configurations represents the effects both of various host geometries and of different viewing angles. We present results for the first part of our survey of model geometries, specifically the effects of the number and size of clumps (and the related effect of filling factor) on the emergent spectrum and Stokes parameters. Our simulations show that random clumpiness can produce line polarization in the range observed in SNe Ia, as well as the Q-U loops that are frequently seen in all SNe. We have also developed a method to connect the results of our simulations to robust observational parameters such as maximum polarization and polarized equivalent width in the line. Our models, in connection with spectropolarimetric observations, can constrain the three-dimensional structure of SN ejecta and offer important insight into the SN explosion physics and the nature of their progenitor systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomaly Detection and Approximate Similarity Searches of Transients in Real-time Data Streams

Abstract We present Lightcurve Anomaly Identification and Similarity Search ( LAISS ), an automated pipeline to detect anomalous astrophysical transients in real-time data streams. We deploy our anomaly detection model on the nightly Zwicky Transient Facility (ZTF) Alert Stream via the ANTARES broker, identifying a manageable ∼1–5 candidates per night for expert vetting and coordinating follow-up observations. Our method leverages statistical light-curve and contextual host galaxy features within a random forest classifier, tagging transients of rare classes ( spectroscopic anomalies), of uncommon host galaxy environments ( contextual anomalies), and of peculiar or interaction-powered phenomena ( behavioral anomalies). Moreover, we demonstrate the power of a low-latency (∼ms) approximate similarity search method to find transient analogs with similar light-curve evolution and host galaxy environments. We use analogs for data-driven discovery, characterization, (re)classification, and imputation in retrospective and real-time searches. To date, we have identified ∼50 previously known and previously missed rare transients from real-time and retrospective searches, including but not limited to superluminous supernovae (SLSNe), tidal disruption events, SNe IIn, SNe IIb, SNe I-CSM, SNe Ia-91bg-like, SNe Ib, SNe Ic, SNe Ic-BL, and M31 novae. Lastly, we report the discovery of 325 total transients, all observed between 2018 and 2021 and absent from public catalogs (∼1% of all ZTF Astronomical Transient reports to the Transient Name Server through 2021). These methods enable a systematic approach to finding the “needle in the haystack” in large-volume data streams. Because of its integration with the ANTARES broker, LAISS is built to detect exciting transients in Rubin data.

79 ASTRONOMY AND ASTROPHYSICS↗

Randomized Trial of Pentoxifylline and Vitamin E vs Standard Follow-up After Breast Irradiation to Prevent Breast Fibrosis, Evaluated by Tissue Compliance Meter

Purpose: To conduct a randomized clinical trial to determine whether the combination of pentoxifylline (PTX) and vitamin E given for 6 months after breast/chest wall irradiation effectively prevents radiation-induced fibrosis (RIF). Methods and Materials: Fifty-three breast cancer patients with localized disease were enrolled and randomized to treatment with oral PTX 400 mg 3 times daily and oral vitamin E 400 IU daily for 6 months after radiation (n=26), or standard follow up (n=27). Tissue compliance meter (TCM) measurements were obtained at 18 months to compare tissue compliance in the irradiated and untreated breast/chest wall in treated subjects and controls. Measurements were obtained at 2 mirror image sites on each breast/chest wall, and the average difference in tissue compliance was scored. Differences in TCM measurements were compared using a t test. Subjects were followed a minimum of 2 years for local recurrence, disease-free survival, and overall survival. Results: The mean difference in TCM measurements in the 2 groups was 0.88 mm, median of 1.00 mm (treated) and 2.10 mm, median of 2.4 mm (untreated). The difference between the 2 groups was significant (P=.0478). Overall survival (100% treated, 90.6% controls at 5 years) and disease-free survival (96.2% treated, 86.8% controls at 5 years) were not significantly different in the 2 groups. Conclusions: This study of postirradiation breast cancer patients treated with PTX/vitamin E or standard follow-up indicated a significant difference in radiation-induced fibrosis as measured by TCM. There was no observed impact on local control or survival within the first 2 years of follow-up. The treatment was safe and well tolerated. Pentoxifylline/vitamin E may be clinically useful in preventing fibrosis after radiation in high-risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

Numerical analysis of randomly forced glycolitic oscillations

Randomly forced glycolytic oscillations in Higgins model are studied both numerically and analytically. Numerical analysis is based on the direct simulation of the solutions of stochastic system. Non-uniformity of the stochastic bundle along the deterministic cycle is shown. For the analytical investigation of the randomly forced Higgins model, the stochastic sensitivity function technique and confidence domains method are applied. Results of the influence of additive noise on the cycle of this model are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UQ Toolkit v 2.0

The Uncertainty Quantification (UQ) Toolkit is a software library for the characterizaton and propagation of uncertainties in computational models. For the characterization of uncertainties, Bayesian inference tools are provided to infer uncertain model parameters, as well as Bayesian compressive sensing methods for discovering sparse representations of high-dimensional input-output response surfaces, and also Karhunen-Loève expansions for representing stochastic processes. Uncertain parameters are treated as random variables and represented with Polynomial Chaos expansions (PCEs). The library implements several spectral basis function types (e.g. Hermite basis functions in terms of Gaussian random variables or Legendre basis functions in terms of uniform random variables) that can be used to represent random variables with PCEs. For propagation of uncertainty, tools are provided to propagate PCEs that describe the input uncertainty through the computational model using either intrusive methods (Galerkin projection of equations onto basis functions) or non-intrusive methods (perform deterministic operation at sampled values of the random values and project the obtained results onto basis functions).

Safta, Cosmin↗

UQ Toolkit v 2.0

The Uncertainty Quantification (UQ) Toolkit is a software library for the characterizaton and propagation of uncertainties in computational models. For the characterization of uncertainties, Bayesian inference tools are provided to infer uncertain model parameters, as well as Bayesian compressive sensing methods for discovering sparse representations of high-dimensional input-output response surfaces, and also Karhunen-Loève expansions for representing stochastic processes. Uncertain parameters are treated as random variables and represented with Polynomial Chaos expansions (PCEs). The library implements several spectral basis function types (e.g. Hermite basis functions in terms of Gaussian random variables or Legendre basis functions in terms of uniform random variables) that can be used to represent random variables with PCEs. For propagation of uncertainty, tools are provided to propagate PCEs that describe the input uncertainty through the computational model using either intrusive methods (Galerkin projection of equations onto basis functions) or non-intrusive methods (perform deterministic operation at sampled values of the random values and project the obtained results onto basis functions).

Source record↗

Space-Time Reduced-Order Modeling for Uncertainty Quantification

This work focuses on the space-time reduced-order modeling (ROM) method for solving large-scale uncertainty quantification (UQ) problems with multiple random coefficients. In contrast with the traditional space ROM approach, which performs dimension reduction in the spatial dimension, the space-time ROM approach performs dimension reduction on both the spatial and temporal domains, and thus enables accurate approximate solutions at a low cost. We incorporate the space-time ROM strategy with various classical stochastic UQ propagation methods such as stochastic Galerkin and Monte Carlo. Numerical results demonstrate that our methodology has significant computational advantages compared to state-of-the-art ROM approaches. By testing the approximation errors, we show that there is no obvious loss of simulation accuracy for space-time ROM given its high computational efficiency.

97 MATHEMATICS AND COMPUTING↗

Enhanced accuracy through ensembling of randomly initialized auto-regressive models for dynamical systems

Computational mechanics simulations using traditional finite element methods (FEM) require prohibitively expensive computational resources for real-time engineering applications, design optimization, and digital twin implementations. While machine learning (ML) surrogate models offer significant computational speedups, autoregressive ML models for time-dependent mechanical systems suffer from error accumulation that compromises long-term prediction reliability - a critical concern for engineering applications where accuracy over extended time horizons is essential for safety and performance assessments. Here, we propose a deep ensemble framework specifically designed to address this challenge in computational mechanics applications, where multiple ML surrogate models with random weight initializations are trained in parallel and their predictions aggregated during inference. This approach leverages statistical diversity to maximize information gain from a fixed set of training data and to mitigate error propagation, while maintaining the computational efficiency that makes ML surrogates attractive for engineering practice. We validate the framework on three representative problems spanning critical areas of computational mechanics: stress field evolution in heterogeneous microstructures under complex loading (relevant to advanced materials design and composite analysis), planetary-scale shallow water dynamics (applicable to environmental and geotechnical engineering), and Gray-Scott reaction-diffusion systems (relevant to mass transport and chemical process engineering). Across all test cases, the ensemble approach demonstrates consistent error reduction of 15-33% compared to individual models. The codes for this work are available on GitHub (https://github.com/Graham-Brady-Research-Group/AutoregressiveEnsemble_SpatioTemporal_Evolution).

autoregressive prediction↗

Radiation Therapy Did Not Induce Long-Term Changes in Rectal Mucosa: Results From the Randomized Scandinavian Prostate Cancer Group 7 Trial

Purpose: To investigate long-term changes in the rectal mucosa after curative external beam radiation therapy in the treatment of prostate cancer. Methods and Materials: In the Scandinavian Prostate Cancer Group 7 trial, 880 men with locally advanced prostate cancer were randomized to hormonal therapy alone versus hormonal therapy plus radiation therapy to 70 Gy. A subcohort from this trial being randomized at our center (n=178) was invited to a study on late anorectal side effects during 2003-2005, approximately 5 years after treatment, including measuring health-reported quality of life and physician-assessed toxicity score by the Late Effects Normal Tissue Task Force/Subjective, Objective, Management, Analytic (LENT/SOMA) and European Organization for Research and Treatment of Cancer/Radiation Therapy Oncology Group score. Sixty-seven patients had a rectal mucosa biopsy. Sixty-four biopsies were included in the final analysis, of which 33 patients were randomized to hormonal treatment and 31 to hormonal treatment plus radiation therapy. The presence of fibrosis, number of capillaries, and lymphocyte infiltration was then evaluated by light microscopy. Results: The group receiving radiation therapy had significantly higher LENT/SOMA and function/bother scale scores than the group that only received hormonal treatment, but there was no significant difference in the presence of fibrosis, ectasia, number of capillaries in the lamina propria, or lymphocyte infiltration between the groups. Conclusion: Radiation therapy to 70 Gy to the prostate does not induce long-term microscopic mucosal changes in the rectum 5 years after treatment. This is in contrast to the general assumption that structural changes, including fibrosis, seen after radiation therapy include the mucosa. We speculate that the main late effects of radiation therapy on the structure of the rectum are located in the deeper layers of the rectal wall than the mucosa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Evaluation of Transcatheter Arterial Chemoembolization (TACE) with Multiple Anti-Cancer Drugs (Epirubicin, Cisplatin, Mitomycin C, 5-Fluorouracil) Compared with TACE with Epirubicin for Treatment of Hepatocellular Carcinoma

Purpose: To compare the efficacy of transcatheter arterial chemoembolization (TACE) using multiple anticancer drugs (epirubicin, cisplatin, mitomycin C, and 5-furuorouracil: Multi group) with TACE using epirubicin (EP group) for hepatocellular carcinoma (HCC). Materials and Methods: The study design was a single-center, prospective, randomized controlled trial. Patients with unrespectable HCC confined to the liver, unsuitable for radiofrequency ablation, were assigned to the Multi group or the EP group. We assessed radiographic response as the primary endpoint; secondary endpoints were progression-free survival (PFS), safety, and hepatic branch artery abnormality (Grade I, no damage or mild vessel wall irregularity; Grade II, overt stenosis; Grade III, occlusion; Grades II and III indicated significant hepatic artery damage). A total of 51 patients were enrolled: 24 in the Multi group vs. 27 in the EP group. Results: No significant difference in HCC patient background was found between the groups. Radiographic response, PFS, and 1- and 2-year overall survival of the Multi vs. EP group were 54% vs. 48%, 6.1 months vs. 8.7 months, and 95% and 65% vs. 85% and 76%, respectively, with no significant difference. Significantly greater Grade 3 transaminase elevation was found in the Multi group (p = 0.023). Hepatic artery abnormality was observed in 34% of the Multi group and in 17.1% of the EP group (p = 0.019). Conclusion: TACE with multiple anti-cancer drugs was tolerable but appeared not to contribute to an increase in radiographic response or PFS, and caused significantly more hepatic arterial abnormalities compared with TACE with epirubicin alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A predictive discrete-continuum multiscale model of plasticity with quantified uncertainty

Multiscale models of materials, consisting of upscaling discrete simulations to continuum models, are unique in their capability to simulate complex materials behavior. The fundamental limitation in multiscale models is the presence of uncertainty in the computational predictions delivered by them. In this work, a sequential multiscale model has been developed, incorporating discrete dislocation dynamics (DDD) simulations and a strain gradient plasticity (SGP) model to predict the size effect in plastic deformations of metallic micro-pillars. The DDD simulations include uniaxial compression of micro-pillars with different sizes and over a wide range of initial dislocation densities and spatial distributions of dislocations. An SGP model is employed at the continuum level that accounts for the size-dependency of flow stress and hardening rate. Sequences of uncertainty analyses have been performed to assess the predictive capability of the multiscale model. The variance-based global sensitivity analysis determines the effect of parameter uncertainty on the SGP model prediction. The multiscale model is then constructed by calibrating the continuum model using the data furnished by the DDD simulations. A Bayesian calibration method is implemented to quantify the uncertainty due to microstructural randomness in discrete dislocation simulations (density and spatial distribution of dislocations) on the macroscopic continuum model prediction (size effect in plastic deformation). Here, the outcomes of this study indicate that the discrete-continuum multiscale model can accurately simulate the plastic deformation of micro-pillars, despite the significant uncertainty in the DDD results. Additionally, depending on the macroscopic features represented by the DDD simulations, the SGP model can reliably predict the size effect in plasticity responses of the micropillars with below 10% of error.

36 MATERIALS SCIENCE↗