Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

SNOM Imaging of a Crypt-Like Feature in Adenocarcinoma Associated with Barrett's Oesophagus

The development of more accurate and sensitive diagnostic techniques is a key factor in efforts to improve cancer survival rates. The technique of infrared aperture fibre scanning near-field optical microscopy (IR-SNOM),together with radiation from the infrared free-electron laser (IR-FEL) on ALICEat Daresbury Laboratory (UK), has been used to obtain IR images of a crypt-like feature and the surrounding tissue; the tissue was taken from a patient with oesophageal adenocarcinoma and with a history of Barrett’s oesophagus. We have shown that the DNA signal is enhanced relative to other contributions in the region of the crypt, and the glycoprotein signal shows a less pronounced increase in the region of the crypt. The Amide II signal is found to be anti-correlated with the DNA and glycoprotein profiles. The absorbance of the Amide II signal is found to differ for three different types of cancer tissue. In conclusion, high-resolution IR images of the crypt reveal additional structure that would not be resolved in diffraction-limited techniques.

60 APPLIED LIFE SCIENCES↗

Microstructures and Microhardness Properties of CMSX-4{sup ®} Additively Fabricated Through Scanning Laser Epitaxy (SLE)

Epitaxial CMSX-4{sup ®} deposition is achieved on CMSX-4{sup ®} substrates through the scanning laser epitaxy (SLE) process. A thorough analysis is performed using various advanced material characterization techniques, namely high-resolution optical microscopy, scanning electron microscopy, energy-dispersive x-ray spectroscopy, x-ray diffraction, and Vickers microhardness measurements, to characterize and compare the quality of the SLE-fabricated CMSX-4{sup ®} deposits to the CMSX-4{sup ®} substrates. The results show that the CMSX-4{sup ®} deposits have smaller primary dendritic arm spacing, finer γ/γ′ size, weaker elemental segregation, and higher microhardness compared to the investment cast CMSX-4{sup ®} substrates. The results presented here demonstrate that CMSX-4{sup ®} is an attractive material for laser-based AM processing and, therefore, can be used in the fabrication of gas turbine hot-section components through AM processing.

36 MATERIALS SCIENCE↗

Single-Molecule Interfacial Electron Transfer

Interfacial electron transfer (ET) plays an important role in many chemical and biological processes. Specifically, interfacial ET in TiO 2 -based systems is important to solar energy technology, catalysis, and environmental remediation technology. However, the microscopic mechanism of interfacial ET is not well understood with regard to atomic surface structure, molecular structure, bonding, orientation, and motion. In this project, we used two complementary methodologies; single-molecule fluorescence spectroscopy, and scanning-tunneling microscopy and spectroscopy (STM and STS) to address this scientific need. The goal of this project was to integrate these techniques and measure the molecular dependence of ET between adsorbed molecules and TiO 2 semiconductor surfaces and the ET induced reactions such as the splitting of water. The scanning probe techniques, STM and STS, are capable of providing the highest spatial resolution but not easily time-resolved data. Single-molecule fluorescence spectroscopy is capable of good time resolution but requires further development to match the spatial resolution of the STM. The integrated approach involving Peter Lu at Bowling Green State University (BGSU) and Wilson Ho at the University of California, Irvine (UC Irvine) produced methods for time and spatially resolved chemical imaging of interfacial electron transfer dynamics and photocatalytic reactions. An integral aspect of the joint research was a significant exchange of graduate students to work at the two institutions. This project bridged complementary approaches to investigate a set of common problems by working with the same molecules on a variety of solid surfaces, but using appropriate techniques to probe under ambient (BGSU) and ultrahigh vacuum (UCI) conditions. The molecular level understanding of the fundamental interfacial electron transfer processes obtained in this joint project will be important for developing efficient light harvesting, solar energy conversion, and broadly applicable to problems in interface chemistry and surface physics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Scanning Quantum Cryogenic Atom Microscope

Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μm) or 6 nT/√Hz per point at its duty cycle. Furthermore, compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT/√Hz for each point during the same time as a point-by-point scanner measures these points sequentially. Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10 -6 Φ 0 /√Hz) over previous atomic probe magnetometers capable of scanning near samples. These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged. We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

LANDSAT-4 thematic mapper Modulation Transfer Function (MTF) evaluation

A power spectrum (PS) analysis technique was used to compare thematic mapper (TM) A and P-tape data for a Washington, DC scene in two orthogonal directions, along scan and along track. The resulting effective modulation transfer functions (MTF) between the A and P data are repeatable from area to area and consistent with theoretical expectations. The average x-direction (along scan) MTF calculated with the PS technique is compared to the MTF of the cubic convolution resampling function used to create P data from A data. The two curves are nearly identical, indicating that the major factor affecting the image quality of P data relative to A data is the cubic convolution resampling.

Schowengerdt, R.↗

Solar Flare Track Exposure Ages in Regolith Particles: A Calibration for Transmission Electron Microscope Measurements

Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Space weathering effects result from multiple processes including: exposure to the solar wind, which results in ion damage and implantation effects that are preserved in the rims of grains (typically the outermost 100 nm); cosmic ray and solar flare activity, which result in track formation; and impact processes that result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. Determining the rate at which these effects accumulate in the grains during their space exposure is critical to studies of the surface evolution of airless bodies. Solar flare energetic particles (mainly Fe-group nuclei) have a penetration depth of a few millimeters and leave a trail of ionization damage in insulating materials that is readily observable by transmission electron microscope (TEM) imaging. The density of solar flare particle tracks is used to infer the length of time an object was at or near the regolith surface (i.e., its exposure age). Track measurements by TEM methods are routine, yet track production rate calibrations have only been determined using chemical etching techniques [e.g., 1, and references therein]. We used focused ion beam-scanning electron microscope (FIB-SEM) sample preparation techniques combined with TEM imaging to determine the track density/exposure age relations for lunar rock 64455. The 64455 sample was used earlier by [2] to determine a track production rate by chemical etching of tracks in anorthite. Here, we show that combined FIB/TEM techniques provide a more accurate determination of a track production rate and also allow us to extend the calibration to solar flare tracks in olivine.

Berger, Eve L.↗

Enhancing Global Change Experiments Through Integration of Remote‐Sensing Techniques

Global change experiments are often spatially and temporally limited because they are time‐ and labor‐intensive, and expensive to carry out. We describe how the incorporation of remote‐sensing techniques into global change experiments can complement traditional methods and provide additional information about system processes. We describe five emerging near‐surface remote‐sensing techniques: spectroscopy, thermal and fluorescence imaging, terrestrial laser scanning, digital repeat photography, and unmanned aerial systems. The addition of such techniques can reduce cost and effort, provide novel information, and expand existing observations by improving their context, accuracy, and completeness. In addition, we contend that use of airborne and satellite remote‐sensing data during site selection can improve the ecological representativeness of future experiments. We conclude by recommending a high level of communication and collaboration between remote‐sensing scientists and ecologists at all stages of global change experimentation.

Alexey N Shiklomanov↗

Physics Discovery in Nanoplasmonic Systems via Autonomous Experiments in Scanning Transmission Electron Microscopy

Abstract Physics‐driven discovery in an autonomous experiment has emerged as a dream application of machine learning in physical sciences. Here, this work develops and experimentally implements a deep kernel learning (DKL) workflow combining the correlative prediction of the target functional response and its uncertainty from the structure, and physics‐based selection of acquisition function, which autonomously guides the navigation of the image space. Compared to classical Bayesian optimization (BO) methods, this approach allows to capture the complex spatial features present in the images of realistic materials, and dynamically learn structure–property relationships. In combination with the flexible scalarizer function that allows to ascribe the degree of physical interest to predicted spectra, this enables physical discovery in automated experiment. Here, this approach is illustrated for nanoplasmonic studies of nanoparticles and experimentally implemented in a truly autonomous fashion for bulk‐ and edge plasmon discovery in MnPS 3 , a lesser‐known beam‐sensitive layered 2D material. This approach is universal, can be directly used as‐is with any specimen, and is expected to be applicable to any probe‐based microscopic techniques including other STEM modalities, scanning probe microscopies, chemical, and optical imaging.

42 ENGINEERING↗

Structural, Microstructural, Magnetic, and Ferroelectric Properties of Ba{sup 2+}-Doped BiFeO{sub 3} Nanocrystalline Multifferroic Material

Multiferroic barium-substituted nanocrystalline samples having the general formula Bi{sub 1−x}Ba{sub x}FeO{sub 3} (where x = 0.00, 0.05, 0.10, 0.15, 0.20, 0.25) were prepared by cost-effective sol–gel method using metal nitrates as oxidants. The prepared samples were annealed at 650 {sup ∘}C for 4 h using a muffle furnace. The influence of Ba{sup 2+} doping on the structural, microstructural, magnetic, and ferroelectric properties of bismuth ferrite (BFO) was studied systematically by standard techniques. All the samples were characterized by X-ray diffraction (XRD) technique, and the average crystallite size was calculated using Scherrer’s formula. The surface morphology of the prepared nanocrystalline samples was studied using field emission scanning electron microscopy (FE-SEM) technique. FTIR spectra were obtained to confirm the formation of the perovskite structures. The elemental compositional details obtained were confirmed by energy dispersive spectrum (EDS) analysis. Room temperature magnetic measurements were carried out up to a field of 15 kOe, and the parent sample (BFO) shows weak ferromagnetism. Further on, Ba{sup 2+} substitution in BFO shows an increase in magnetization. P–E loops were obtained to study the ferroelectric properties of all the samples. Obtained enhancement in magnetic and ferroelectric properties at room temperature is of great interest within the research community due to its wide range of applications in memory storage, spintronics, sensors, and multi-functional devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Cloud Interior Structure Using a Tomographic Technique Based on Radon Transform. Application to the Measurements Made by the Research Scanning Polarimeter During CAMP2Ex

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP's uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid-water cloud droplet sizes using the rainbow structure observed in the polarized reflectance measurements. The RSP observations also provide for derivation of 2D field of extinction coefficient inside the cloud using a tomographic technique. This technique utilizes the family of cloud shapes derived using "cutout" technique and corresponding to a number of thresholds in total reflectance (separating bright cloud from its darker background). These shapes can be interpreted as level curves of an abstract "reflectance density", which is then used for derivation of the directional cloud optical thickness (dCOT) tomogram. The latter is a collection of dCOTs parameterized by the angles and offsets of the corresponding view rays (chords) relative to the cloud center. After this, the inverse Radon Transform (the mathematical basis of the X-ray com-puter tomography) is applied to the dCOT tomogram yielding 2D spatial distribution of the extinction coefficient. The later can be converted into droplet number concentration using the droplet size profiles derived from the RSP's polarized reflectance measurements. After tests on synthetic data this technique was applied to real RSP measurements from NASA's Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) conducted in the vicinity of the Philippines during the Southwest Monsoon (August–September 2019). We have investigated the interiors of a number of clouds observed during CAMP2Ex focusing on Cu and CuCg (Tcu) cases. Our retrievals were routinely compared with the correlative measurements by lidar (HSRL-2) and cloud radar (APR-3) that were deployed on the same airborne platform (NASA P-3B) during this field experiment.

Research Scanning Polarimeter↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

An insight into microscopy and analytical techniques for morphological, structural, chemical, and thermal characterization of cellulose

Cellulose obtained from plants is a bio-polysaccharide and the most abundant organic polymer on earth that has immense household and industrial applications. Hence, the characterization of cellulose is important for determining its appropriate applications. In this article, we review the characterization of cellulose morphology, surface topography using microscopic techniques including optical microscopy, transmission electron microscopy, scanning electron microscopy, and atomic force microscopy. Additionally, other physicochemical characteristics like crystallinity, chemical composition, and thermal properties are studied using techniques including X-ray diffraction, Fourier transform infrared, Raman spectroscopy, nuclear magnetic resonance, differential scanning calorimetry, and thermogravimetric analysis. This review may contribute to the development of using cellulose as a low-cost raw material with anticipated physicochemical properties.

59 BASIC BIOLOGICAL SCIENCES↗

An analysis of short pulse and dual frequency radar techniques for measuring ocean wave spectra from satellites

Scanning beam microwave radars were used to measure ocean wave directional spectra from satellites. In principle, surface wave spectral resolution in wave number can be obtained using either short pulse (SP) or dual frequency (DF) techniques; in either case, directional resolution obtains naturally as a consequence of a Bragg-like wave front matching. A four frequency moment characterization of backscatter from the near vertical using physical optics in the high frequency limit was applied to an analysis of the SP and DF measurement techniques. The intrinsic electromagnetic modulation spectrum was to the first order in wave steepness proportional to the large wave directional slope spectrum. Harmonic distortion was small and was a minimum near 10 deg incidence. NonGaussian wave statistics can have an effect comparable to that in the second order of scattering from a normally distributed sea surface. The SP technique is superior to the DF technique in terms of measurement signal to noise ratio and contrast ratio.

Jackson, F. C.↗

Managing age-related changes in device radiation-response.

Aging effects in silicon electronics are a concern for systems with prolonged service lives that contain electronics not easily accessible for testing and replacement. Such effects are especially difficult to assess for components that must be exposed to, and function in, transient radiation environments. A methodology has been developed that utilizes electrical parametric and non-destructive laser testing techniques, charge collection microscopy, and controlled-environment storage to permit periodic reassessment of the state of health of such electronics. The use of a scanned, focused laser, charge collection microscopy technique, developed to detect the onset of change and then track these changes in charge collection efficiency with micron resolution, will be described. These results are then used to direct subsequent failure analyses using high-sensitivity, high spatial resolution materials analysis techniques, (such as Time-of-Flight SIMS), in order to identify the underlying material driver of the aging. It will be shown how the results of this methodology are used to create finite-element, charge transport, device models of age-affected devices, and how the time-dependence of the underlying material change is incorporated into the device aging model, so as to predict the future rate, and end-state, of the identified device aging process. Lastly the model is validated using wavelength-dependent charge collection microscopy measurements of the device's response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contrast Mechanisms in Secondary Electron e-Beam-Induced Current (SEEBIC) Imaging

Abstract Over the last few years, a new mode for imaging in the scanning transmission electron microscope (STEM) has gained attention as it permits the direct visualization of sample conductivity and electrical connectivity. When the electron beam (e-beam) is focused on the sample in the STEM, secondary electrons (SEs) are generated. If the sample is conductive and electrically connected to an amplifier, the SE current can be measured as a function of the e-beam position. This scenario is similar to the better-known scanning electron microscopy-based technique, electron beam-induced current imaging, except that the signal in the STEM is generated by the emission of SEs, hence the name secondary electron e-beam-induced current (SEEBIC), and in this case, the current flows in the opposite direction. Here, we provide a brief review of recent work in this area, examine the various contrast generation mechanisms associated with SEEBIC, and illustrate its use for the characterization of graphene nanoribbon devices.

47 OTHER INSTRUMENTATION↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗

SU-E-T-337: Treatment Planning Study of Craniospinal Irradiation with Spot Scanning Proton Therapy

Purpose: To develop a treatment planning technique that achieves optimal robustness against systematic position and range uncertainties, and interfield position errors for craniospinal irradiation (CSI) using spot scanning proton radiotherapy. Methods: Eighteen CSI patients who had previously been treated using photon radiation were used for this study. Eight patients were less than 10 years old. The prescription dose was 23.4Gy in 1.8Gy fractions. Two different field arrangement types were investigated: 1 posterior field per isocenter and 2 posterior oblique fields per isocenter. For each field type, two delivery configurations were used: 5cm bolus attached to the treatment table and a 4.5cm range shifter located inside the nozzle. The target for each plan was the whole brain and thecal sac. For children under the age of 10, all plan types were repeated with an additional dose of 21Gy prescribed to the vertebral bodies. Treatment fields were matched by stepping down the dose in 10% increments over 9cm. Robustness against 3% and 3mm uncertainties, as well as a 3mm inter-field error was analyzed. Dose coverage of the target and critical structure sparing for each plan type will be considered. Ease of planning and treatment delivery was also considered for each plan type. Results: The mean dose volume histograms show that the bolus plan with posterior beams gave the best overall plan, and all proton plans were comparable to or better than the photon plans. The plan type that was the most robust against the imposed uncertainties was also the bolus plan with posterior beams. This is also the plan configuration that is the easiest to deliver and plan. Conclusion: The bolus plan with posterior beams achieved optimal robustness against systematic position and range uncertainties, as well as inter-field position errors.

60 APPLIED LIFE SCIENCES↗