Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sheaths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

Ultraviolet Radiation

The lunar surface has a complex plasma environment due to incoming solar wind flux and charged micron-sized dust particles and the presence of solar ultraviolet (UV) radiation. UV resonance fluorescence of solar radiation provides a sensitive detection of major elemental constituents, such as H, H2, O, C, N, and noble gases in the tenuous daytime lunar atmosphere. Photoemission due to the solar UV radiation is the dominating process in the charging environment, creating a photoelectron “sheath.” Such detections were observed by LADEE UV spectrometer and the Apollo 17 UV spectrometer.

Caitlin Ahrens↗

The Chain-link Actuator: Exploiting the Bending Stiffness of McKibben Artificial Muscles to Achieve Larger Contraction Ratios

McKibben artificial muscles, comprised of an ex-pandable bladder wrapped in a double-helix-braided sheath,have the ability to generate forces without restricting motion tooccur exclusively along the direction of actuation. This makesthem attractive for a variety of applications including soft,wearable, and biomimetic robots. Despite their advantages, thetheoretical maximum contraction ratio of McKibben muscles isonly 36.3%, which restricts the range of motion of the systemsthey actuate. This work introduces a novel ‘chain-link actuator’that exploits the bending stiffness of McKibben muscles toachieve contraction ratios of more than 50%. A static modelthat captures the relationship between pressure, displacement,and force is presented and validated on several real chain-linkactuator systems.

Daniel Bruder↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

Effect of salinity on the preservation of biomarkers in hypersaline microbial mat kerogens

Kerogen is the residue that remains after the minerals and organic compounds have been extracted from a rock using acid and organic solvents, respectively [1]. It is not only the largest organic carbon sink in the geological record but the best-preserved fraction due to its recalcitrance and ability to retain syngenetic source information during deposition [2]. Due to the complex, macromolecular, cross-linked polymeric structure of kerogen, it is difficult to analyse intact, often requiring breakdown into smaller subunits through thermal (pyrolysis) or chemical treatment (chemolysis) [3]. Saline and hypersaline environments host diverse microbial communities, which can trap and bind organic matrices such as cellular components (e.g., extracellular polymeric substances, cell wall, peptidoglycan, sheath material, etc.) with sediments, forming layered, laminated structures called microbial mats. Here we present depth profiles of two hypersaline cores through a microbial mat with differing total salinities. We looked at the composition of organic compounds released from kerogen during high temperature, hydrogen-assisted, pyrolysis to understand the effect of salinity on the composition and timing of their incorporation [4]. Field Site: The Exportadora del Sal S. A. (ESSA) saltern of Guerrero Negro (Baja California Sur, Mexico) lies within a typical sabhka environment adjacent to Laguna Ojo de Liebre. Note the spatial extent of the 13 major ponds of the ESSA system. The GN ponds thrive under well-monitored and stable conditions with steady state accretion and degradation of mat layers (around 0.5–1.4 cm per year). Organic mats typically attain up to 10 cm in thickness, depending on the location, which represents about 60 years of growth since these ponds were established. Sedimentation rate is rapid in these non-lithifying and non-mineralising mats, 1–1.5 cm per year. This environment is ideal for investigating in situ lipid preservation and diagenesis without the influence of constantly changing physical parameters. Methods: P4n5 and P5AB cores were collected as ~9 cm and 6.5 cm fresh cores, respectively, in June 2001 and September 2010, respectively from the ESSA saltern. The P4n5 core (9-9.1% salinity) was taken from Pond 4 near 5 and sub-divided into 10 layers. The P5AB core (11.2% salinity) was taken from Pond 5A near 5B and sub-divided into 8 layers. Lyophilised microbial mat powders were solvent-extracted using a modified Bligh-Dyer method and analysed by gas chromatography-mass spectrometry (GC-MS). Additionally, a subset of layers—layer 4 and layer 7—which represented active biomass and sediment-processed, respectively, were subjected to mild-acid methanolysis. The respective residues from conventional solvent extraction and acid methanolysis were loaded with a molybdenum sulfide catalyst and placed into a stainless-steel reactor. Samples were run on the hydropyrolysis set up (heated to 500 °C with 13-15 MPa of H2 pressure), extracted, and analysed by GC-MS. Results: Molecular profiles from the two ponds were significantly different and reflect the contributions of different photosynthetic and respiratory microbial communities to preserved organic matter. For example, the higher salinity P5AB core showed evidence of greater archaeal inputs (similarly observed in lab culture experiments [5]) as well as potential kerogen-bound carotenoids/carotenoid rearranged products or fragments. A hydrophobic emulsion formed during the acid methanolysis processing of layer 4 from both P4n5 and P5AB and layer 7 of P5AB. Hydropyrolysis of this hydrophobic residues released a greater abundance of polycyclic lipids relative to the pre-extracted control. Implications and Future Work: Catalytic hydropyrolysis of kerogen can rapidly generate abundant saturated pyrolysate products from the bound biomarker pool without altering the structures or stereochemistries of the products [6]. Chemical processing of solvent-extractable residues indicated that cellular matrices such as extracellular polymeric substances (EPS) may play a role in the sequestration of polycyclic lipid biomarkers such as steranes and hopanes. Their higher relative abundance compared to the pre-extracted control in the higher salinity layers and cores preliminarily aligns with this hypothesis, although further experiments are required to confirm this. It has been well-documented that EPS plays an important role in mineralisation, specifically carbonate formation, in microbial ecosystems. EPS can enhance calcium carbonate precipitation by providing diffusion-limited sites that create alkalinity gradients in response to microbial processes [7]. It has been experimentally demonstrated that salinity influences the total amount of EPS (both loosely- and tightly-bound) which increases with increasing salinity [8]. The higher salinity at Guerrero Negro switches the microbial population from filamentous Microcoleus to being dominated by Phormidium, Oscillatoria, and unicellular cyanobacteria. We demonstrated that lipid binding into kerogen via strong covalent linkages occurs at the very earliest stages of sedimentary diagenesis. We are currently investigating the influence of salinity on organic preservation through experimental and modelling approaches. Understanding how key biomarkers transform into preserved organic matter (i.e., from precursor biolipids to bound geolipids) in brine ecosystems will aid the search for organic biosignatures on other planetary bodies, especially Icy Moons and modern Mars.

hypersaline↗

Optimizing Single Nuclei Sequencing of Brain Samples From Space Flown Mice Across Age and Strain

The NASA GeneLab Sample Processing Laboratory offers high-throughput sequencing services to NASA-funded space biology researchers. Space biology studies have specific challenges such as low sample numbers, introducing susceptibility to batch effects from sample handling. These issues are compounded by complex protocols such as single-nuclei isolation and sequencing, which has recently become an attractive methodology for assessing the cellular diversity within spaceflight samples. High quality single-nuclei sequencing requires reproducible protocols to dissociate tissue and generate clean suspension of intact single nuclei. Producing single-nuclei suspension from brain tissue is particularly challenging due to cell type heterogeneity and the myelin sheath that carries over into the nuclei suspension as debris. Current procedures tend to be time consuming and sometimes include steps that can alter gene expression and create cell-type bias. Commercially available nuclei isolation kits, such as the 10X Genomics nuclei isolation kit, offers a streamlined way to process samples for nuclei isolation, thereby minimizing batch effects and enabling reproducibility. In this study, we report on the performance of the 10X Genomics nuclei isolation kit and Chromium Next GEM Single Cell Multiome ATAC + Gene Expression kit to generate sequencing libraries from space-flown mouse brain samples. Single nuclei sequencing was performed on frozen mouse brain tissue from two spaceflight missions, Rodent Research-10 (RR-10) and RR Reference Mission-2 (RRRM-2). RR-10 mice were female B6129SF2/J, euthanized at 18-19 weeks whereas RRRM-2 mice were female C57BL/6NTac, euthanized at 20 or 37 weeks. Sequencing data was processed using standard GeneLab data processing pipelines. We report evaluation of the performance of the 10X Genomics nuclei isolation kit for spaceflight samples from mouse brain, and evaluation of reproducibility across different mouse strains and age groups. We also report preliminary scientific results including cell type inference, cell clustering, and differentially expressed genes and pathways between spaceflight and ground control samples.

RR-10↗

Discovery of X-Ray Polarization Angle Rotation in the Jet From Blazar Mrk 421

The magnetic-field conditions in astrophysical relativistic jets can be probed by multiwavelength polarimetry, which has been recently extended to X-rays. For example, one can track how the magnetic field changes in the flow of the radiating particles by observing rotations of the electric vector position angle Ψ. Here we report the discovery of a ΨX rotation in the X-ray band in the blazar Markarian 421 at an average flux state. Across the 5 days of Imaging X-ray Polarimetry Explorer observations on 4–6 and 7–9 June 2022, ΨX rotated in total by ≥360°. Over the two respective date ranges, we find constant, within uncertainties, rotation rates (80 ± 9° per day and 91 ± 8° per day) and polarization degrees (ΠX = 10% ± 1%). Simulations of a random walk of the polarization vector indicate that it is unlikely that such rotation(s) are produced by a stochastic process. The X-ray-emitting site does not completely overlap the radio, infrared and optical emission sites, as no similar rotation of Ψ was observed in quasi-simultaneous data at longer wavelengths. We propose that the observed rotation was caused by a helical magnetic structure in the jet, illuminated in the X-rays by a localized shock propagating along this helix. The optically emitting region probably lies in a sheath surrounding an inner spine where the X-ray radiation is released.

Makarian 421↗

ISS Technology Demonstrations for Future Spaceflight Medical Systems

Throughout the history of human spaceflight, crewmembers have experienced various in-flight medical conditions including illness and injury. Planned missions to the Moon and Mars will require capabilities to maintain the health of future space travelers. Mass, power, and volume available in the vehicles and habitats for these missions will be severely constrained; resupply of resources will be limited or non-existent, as will opportunities for evacuation to Earth. Furthermore, ground-based support will be hampered by communication latencies and blackouts. These vehicle and mission constraints will necessitate a medical system that has been efficiently planned, providing on-board procedural guidance in addition to a variety of medical devices and consumable resources. Medical capabilities required for the diagnosis and treatment of potential medical conditions during future spaceflight missions may include real-time health monitoring, medical imaging, and biomarker analyses ( e.g., blood or urine). Terrestrial medicine shares these needs, thus many of these medical capabilities could likely be satisfied by Commercial-Off-The-Shelf (COTS) devices and methodologies; however, in some cases the unique space environment and increased mission duration will drive the need to modify technologies and the way care is provided. NASA’s Human Research Program (HRP) Exploration Medical Capability (ExMC) Element and Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) are working together to decrease medical risk during exploration missions. Flight-tested medical diagnostic and treatment technologies are necessary to effectively manage medical conditions relevant to exploration missions while meeting vehicle constraints, integrating with medical decision-support tools, and enabling increasingly Earth-independent operations. Several projects have leveraged the ISS as a testbed for exploration, including 1) i n- situ blood analysis, 2) medical inventory, 3) intravenous fluid generation, and 4) autonomous medical procedure guidance. Management of several in-flight medical conditions, such as bacterial and viral infections and acute radiation syndrome, is dramatically improved with ability to assess blood cell populations, electrolytes, and metabolites. I n December 2020 and January 2021 ExMC performed an ISS technology demonstration (Tech Demo) of the HemoCue® WBC DIFF analyzer (HemoCue, Brea, CA), a COTS device that was modified to enable functionality in a spaceflight environment. This Tech Demo marked the first time that hematology measurements were successfully performed real-time in microgravity. Also modified and demonstrated was the reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH) ONE analyzer (rHEALTH, Bedford, MA), which uses flow cytometry and sheath-based hydrodynamic focusing methodologies. The rHEALTH ONE ISS Tech Demo in May 2022 demonstrated test results obtained in-flight matched those on the ground. NASA currently relies on crew self-reporting to manage and maintain medical inventory on ISS.The ability to maintain an accurate inventory becomes more critical during long duration missions since the crew will need to be increasingly autonomous in finding and utilizing medical items, including those scenarios when alternative treatments need to be considered due to limited or no resupply. HRP’s Medical Consumables Tracking (MCT) project was developed by ZIN Technologies, Inc. (Cleveland, OH), and demonstrated real-time tracking of medical supplies aboard the ISS between December 2016 and July 2018. The MCT system design utilized Radio Frequency Identification Device (RFID) technology to perform automated inventory and was installed in the Crew Health Care System (CHeCS) Resupply Stowage Rack (RSR). The challenge of limited shelf life, exacerbated by the lack of resupply opportunities, affects a plethora of medical system components including consumables, pharmaceuticals, and intravenous (IV) fluid. In 2010, ExMC funded ZIN Technologies, Inc. (Cleveland, OH), to develop the Intravenous Fluid Generation (IVGEN) system. IV fluids were successfully generated with IVGEN using the potable water supply on ISS during ISS Expedition 23. The XMIPT is in the process of developing a miniaturized version of the original IVGEN hardware for a future Tech Demo aboard the ISS. Current ISS medical operations rely heavily on preflight training and real-time remote guidance, both of which become impractical or impossible for exploration missions. The primary goal of the Autonomous Medical Officer Support (AMOS) Software Tech Demos on ISS was to confirm telemedical proof-of-concept for autonomous medical imaging in an operational setting. This novel software tool shifts emphasis from preflight training and real-time remote guidance to in-flight just-in-time instruction, a new and necessary paradigm for crew medical autonomy. AMOS introduces a novel, streamlined skill management concept for exploration missions featuring comprehensive training and guidance modules for ultrasound examinations using the ISS Ultrasound 2 (a modified GE Vivid-q™; General Electric HealthCare, Chicago, IL). With no prior crew training or remote guidance, two Tech Demos on the ISS (April 2020 and June 2022) resulted in high quality, clinically useful image sets. We will provide a review of historical, current, and planned medical devices and technologies considered for inclusion within future spaceflight medical systems and summarize hardware development activities and medical device tech demos conducted on the ISS.

Astronaut health and performance↗

Unveiling the Journey of A Highly Inclined CME: Insights from the March 13, 2012, Event With 110° Longitudinal Separation

Context. A fast (∼2000 km s -1 ) and wide (>110°) coronal mass ejection (CME) erupted from the Sun on March 13, 2012. Its interplanetary counterpart was detected in situ two days later by STEREO-A and near-Earth spacecraft, such as ACE, Wind, and Cluster. We suggest that at 1 au the CME extended at least 110° in longitude, with Earth crossing its east flank and STEREO-A crossing its- west flank. Despite their separation, measurements from both positions showed very similar in situ CME signatures. The solar source region where the CME erupted was surrounded by three coronal holes (CHs). Their locations with respect to the CME launch site were east (negative polarity), southwest (positive polarity) and west (positive polarity). The solar magnetic field polarity of the area covered by each CH matches that observed at 1 au in situ. Suprathermal electrons at each location showed mixed signatures with only some intervals presenting clear counter streaming flows as the CME transits both locations. The strahl population coming from the shortest magnetic connection of the structure to the Sun showed more intensity. Aims. The aim of this work is to understand the propagation and evolution of the CME and its interaction with the surrounding CHs, to explain the similarities and differences between the observations at each spacecraft, and report what one of the most longitudinal expanded CME structures measured in situ would be. Methods. Known properties of the large-scale structures from a variety of catalogues and previous studies were used to have a better overview of this particular event. In addition, multipoint observations were used to reconstruct the 3D geometry of the CME and determine the context of the solar and heliospheric conditions before the CME eruption and during its propagation. The graduated cylindrical shell model (GCS) was used to reproduce the orientation, size and speed of the structure with a simple geometry. Also, the Drag-Based Model (DBM) was utilised to understand the conditions of the interplanetary medium better in terms of the drag undergone by the structure while propagating in different directions. Finally, a comparative analysis of the different regions of the structure through the different observatories was carried out in order to directly compare the in situ plasma and magnetic field properties at each location. Results. The study presents important findings regarding the in situ measured CME on March 15, 2012, detected at a longitudinal separation of 110° in the ecliptic plane despite its initial inclination being around 45° when erupted (March 13). This suggests that the CME may have deformed and/or rotated, allowing it to be observed near its legs with spacecraft at a separation angle greater than 100°. The CME structure interacted with high-speed streams generated by the surrounding CHs. The piled-up plasma in the sheath region exhibited an unexpected correlation in magnetic field strength despite the large separation in longitude. In situ observations reveal that at both locations there was a flank encounter – where the spacecraft crossed the first part of the CME – then encountered ambient solar wind, and finally passed near the legs of the structure. Conclusions. A scenario covering all evidence is proposed for both locations with a general view of the whole structure and solar wind conditions. Also, the study shows the necessity of having multipoint observations of large-scale structures in the heliosphere.

methods: data analysis↗

On the Mesoscale Structure of Coronal Mass Ejections at Mercury’s Orbit: BepiColombo and Parker Solar Probe Observations

On 2022 February 15, an impressive filament eruption was observed off the solar eastern limb from three remote-sensing viewpoints, namely, Earth, STEREO-A, and Solar Orbiter. In addition to representing the most-distant observed filament at extreme ultraviolet wavelengths—captured by Solar Orbiter's field of view extending to above 6 R ⊙ —this event was also associated with the release of a fast (∼2200 km s −1 ) coronal mass ejection (CME) that was directed toward BepiColombo and Parker Solar Probe. These two probes were separated by 2° in latitude, 4° in longitude, and 0.03 au in radial distance around the time of the CME-driven shock arrival in situ. The relative proximity of the two probes to each other and the Sun (∼0.35 au) allows us to study the mesoscale structure of CMEs at Mercury's orbit for the first time. We analyze similarities and differences in the main CME-related structures measured at the two locations, namely, the interplanetary shock, the sheath region, and the magnetic ejecta. We find that, despite the separation between the two spacecraft being well within the typical uncertainties associated with determination of CME geometric parameters from remote-sensing observations, the two sets of in situ measurements display some profound differences that make understanding the overall 3D CME structure particularly challenging. Finally, we discuss our findings within the context of space weather at Mercury's distance and in terms of the need to investigate solar transients via spacecraft constellations with small separations, which has been gaining significant attention during recent years.

Erika Palmerio↗

Evaluation of High-Temperature Fabrics for Improved Performance of Seals and Thermal Barriers

Hypersonic and space flight applications continue to push material demands of component-level technologies such as high-temperature seals and thermal barriers. NASA Glenn Research Center continues to develop and evaluate materials and coatings as well as thermal barrier designs for these applications. Experimental test data is presented for two different sheath fabrics that were evaluated in full thermal barrier assemblies through compression and wear testing at elevated temperatures, as well as flow testing at ambient temperature.

Seals↗

NASA Talks: Harsh Lunar Environments

NASA Talks - Exploration drives technology, and as NASA works toward sustained operations on the lunar surface for a permanent moonbase, it is critical to understand how the location drives what’s needed to accomplish these goals. This is especially important as we land on the lunar South Pole, which will be different and riskier than the previous Apollo landing sites. The thermal conditions will be much colder, the lighting environment is challenged with low sun angles, the regolith holds a charge in the plasma sheath, and the radiation is significantly higher than in low Earth orbit (LEO). Stephanie Sipila, Deputy Manager of Extravehicular Activity and Human Surface Mobility Program (EHP) Technology, Integration and Partnerships Office, provided knowledge and insight into the game-changing technologies NASA is exploring to mitigate these risks.

Stephanie Sipila↗

Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) Field Campaign Report

The Southern Ocean (SO) is the stormiest place on earth, buffeted by winds and waves that circle the ice of Antarctica, sheathed in clouds that mantle a dynamic ocean with rich ecosystems. The remote and usually pristine environment, typically removed from anthropogenic and natural continental aerosol sources, makes the SO unique for examining cloud-aerosol interactions for liquid and ice clouds, and the role of primary and secondary marine biogenic aerosols and sea salt. There is strong seasonality in aerosol sources and sinks over the SO that are poorly understood. Weather and climate models are challenged by uncertainties and biases in the simulation of SO clouds, aerosols, precipitation, and radiative transfer that trace to poor physical understanding of these processes, and by cloud feedbacks (e.g., phase changes) in response to warming. Models almost universally underestimate sunlight reflected by near-surface cloud, particularly in the cold sector of cyclonic storm systems, and this may be due to difficulties in representing pervasive supercooled and mixed-phase boundary-layer (BL) clouds. The Southern Ocean Clouds Radiation Transport Aerosol Transport Experimental Study (SOCRATES) white paper (Marchand et al. 2014) describes the motivation, scientific themes, and testable hypotheses that led to a multi-agency and international measurement campaign to study clouds, aerosols, and the air-sea interface over the SO. As a separate project within this international umbrella, the Measurement of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field program was conducted between 29 October 2017 and 25 March 2018. During MARCUS, instruments from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s second Mobile Facility (AMF2) were installed on the Australian icebreaker Aurora Australis as it made resupply missions from Hobart, Tasmania to the Australian Antarctic stations of Casey, Mawson, and Davis, as well as Macquarie Island. Figure 1 shows the voyages conducted during MARCUS. The MARCUS data are unique in that they are the only set of data in the broader international effort that a) acquired comprehensive observations of clouds, aerosols, and radiation south of 60&deg;S, and b) acquired measurements across the full SO latitudinal range in the spring and fall seasons.

atmospheric emitted radiance interferometer↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Diode assembly and method of forming a diode assembly for pulsed fusion events

A diode assembly for producing a pulsed fusion event in a z-pinch driver. The diode assembly includes an inner core formed of a fusionable fuel source material including a lithium compound formed of one or more lithium isotopes and one or more hydrogen isotopes. A lithium metal outer sheath is integrally formed around the inner core by decomposing a surface of the fusionable fuel source material.

Brown, Sam W.↗

Expandable implant and implant system

An embodiment of the invention includes an expandable implant to endovascularly embolize an anatomical void or malformation, such as an aneurysm. An embodiment is comprised of a chain or linked sequence of expandable polymer foam elements. Another embodiment includes an elongated length of expandable polymer foam coupled to a backbone. Another embodiment includes a system for endovascular delivery of an expandable implant (e.g., shape memory polymer) to embolize an aneurysm. The system may include a microcatheter, a lumen-reducing collar coupled to the distal tip of the microcatheter, a flexible pushing element detachably coupled to an expandable implant, and a flexible tubular sheath inside of which the compressed implant and pushing element are pre-loaded. Other embodiments are described herein.

Wilson, Thomas S.↗

Quantifying microbial roles in environmental iron oxidation via an integrated kinetics, `omics and metabolic modeling study (Final Report)

Iron oxyhydroxides are extremely reactive components of environmental systems, and therefore exert a strong influence on biogeochemical cycles. These oxyhydroxides strongly adsorb many biologically-relevant elements, including organic carbon and phosphate, as well as a wide range of metals including uranium and actinide species. Thus, the formation mechanism of iron oxyhydroxides are key to understanding both nutrient and contaminant cycling. Microorganisms can catalyze iron oxidation and promote the formation of Fe biominerals and thus are increasingly recognized as important players in biogeochemical cycling. However, it is completely unknown how much of environmental iron oxidation is biologically mediated versus abiotic, and various challenges in studying microbial iron oxidation have hindered accurate incorporation into hydrobiogeochemical models. The overarching goal of our work was to quantify and constrain microbial iron oxidation rates and use ‘omics to gain insight into the controls on this process, while developing tools to enable integration of biotic iron oxidation into hydrobiogeochemical models. Our work focused on the Savannah River Site (SRS) in South Carolina, where extensive microbial iron oxidation has been observed. At Tims Branch, part of the Argonne National Laboratory Wetland Hydrobiogeochemistry Science Focus Area (Argonne SFA), where groundwater discharges into a stream, iron-oxidizing microbial mats form and appear to be a major sink of uranium. In the wetlands that surround Tims Branch, there are wide swaths of iron microbial mats and flocs (mobilized mat). We measured biotic and abiotic iron oxidation rates using mats and water sampled from these sites and found that iron oxidation is primarily carried out by chemolithotrophic microorganisms. The resulting rate constants can be incorporated into models. These mats were characterized by metagenomics and metatranscriptomics, which showed that aerobic chemolithotrophs were the dominant iron-oxidizing bacteria (FeOB), and these included Gallionellaceae and Leptothrix, and possibly Rhodoferax, which is known as an Fe-reducer but may also oxidize Fe(II). This demonstrated that diverse FeOB can coexist and suggests that there are a range of niches and therefore drivers of chemolithotrophic iron oxidation. Analysis of reconstructed genomes strongly suggests that a major factor in diversity is carbon source, as genomes contained varied pathways for autotrophy and heterotrophy. We performed an in-depth analysis of Leptothrix ochracea genomes, since this sheath-former is one of the primary mat builders, yet its physiology remained unresolved. A combination of genomics, transcriptomics, and metabolic modeling suggest that L. ochracea grows mixotrophically using a combination of Fe(II) and organics for energy and both inorganic and organic carbon to create biomass. This contrasts with the largely autotrophic Gallionellaceae (Gallionella, Sideroxydans, and Ferriphaselus) also present in the mats and flocs. Remarkably, multiple FeOB, both Leptothrix and Gallionellaceae, showed activity in response to Fe(II) in live mat incubations. We tracked the gene expression of individual MAGs to Fe(II) and found that various autotrophic and heterotrophic FeOB responded to Fe(II), increasing expression of both carbon fixation and organic utilization genes. The results of the integrated field, kinetics, and omics studies give detailed insight into 1) the taxa that oxidize Fe, and 2) how they connect Fe, C, and N cycles. Towards the goal of connecting omics data to hydrobiogeochemical models, we worked with the KBase team to create a template metabolic model for chemolithotrophic iron oxidation. We initially modeled the well-characterized isolate Gallionellaceae Sideroxydans lithotrophicus, and also applied the model to the mixotroph L. ochracea. In all, we have characterized diverse FeOB in a representative wetland system and solved key problems that enable better incorporation of iron-oxidizing microbes into hydrobiogeochemical models.

54 ENVIRONMENTAL SCIENCES↗

Influence of Joule Heating on the Stability of High Temperature Irradiation Resistant Thermocouples

Development of in-core instrumentation is driven by the pursuit of safer and more economic energy production from both existing nuclear reactors and Generation IV reactor designs. Idaho National Laboratory (INL) has developed high temperature irradiation resistant thermocouples (HTIR-TCs) for temperature sensing inside Generation IV nuclear reactors. These thermocouples are composed of phosphorus-doped niobium (Nb-P) and lanthana-doped molybdenum (Mo-LaO) thermoelements, an alumina (Al2O3) insulation, and a niobium sheath. HTIR-TCs require an initial heat treatment exceeding the maximum service temperature to stabilize the generated electromotive force (EMF) signal; however, the mechanism behind this stabilization is not well understood. This work evaluates the impact of Joule heating on the thermoelements' microstructures, chemical stability, and mechanical properties to determine the mechanisms by which the EMF signal stabilization occurs. Accordingly, during the Joule heat treatment, a secondary Nb3P phase coarsened along the length of the Nb-P thermoelement, along with the formation of an interaction region at the Al2O3/niobium interface. The interaction between the alumina insulation and the Nb-P thermoelement was also observed within the Mo-LaO thermoelement. Joule heating induced stability within the generated EMF signal of HTIR-TCs through the formation of secondary phases within the Nb-P and the interaction of the alumina insulation with the thermoelements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗