Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Integrated optical components in thin films of polymers

The results will be reported on the study of integrated optical components based on nonlinear optical polymeric films. Polymers poly(methyl methacrylate) (PMMA) and polyimide (PI) doped with organic laser dyes 4-dicyanomethylene-2-methyl-6-p dimethylaminostyryl-4H pyran (DCM) and 1, 3, 5, 7, 8 - pentamethyl-2,6 -diethyl-pyrromethene -BF2-complex (Pyrommethene 567, PM-567) were selected as materials for light guiding films. Additionally, UV polymerized polydiacetylene (PDA) on glass substrate was used as a waveguide material. Optical waveguides were fabricated using spin coating of preoxidized silicon wafers (1.5 micrometer silicon oxide layer) with organic dye/polymer solution followed by soft baking. the modes in slab waveguides were studied using prism coupling techniques. Measured values of mode coupling angles in multimode waveguides were used to calculate film thickness and refractive index for different polarizations. Refractive index anisotropy was found in PDA waveguide. The optimal conditions of spin coating for single mode waveguide fabrication were estimated. Propagation losses were measured by collecting the light scattered from the trace of a propagating mode either by scanning photo detector or by CCD camera. Different types of light coupling techniques were used including end-dire coupling, prism and grating coupling. Mechanical printing technique was developed for coupling grating fabrication resulting in gratings with 4% diffraction efficiency. The gratings demonstrated good stability with diffraction efficiency relaxation rate 2.4 dB/hour at a temperature approximately 15-20 C below glass transition point. Dye doped waveguides were transversally pumped with frequency doubled Nd:YAG Q-switched laser producing intensive light emission with apparent 6 kW/sq cm pump threshold and spectrum narrowing near 617 nm peak in the case of DCM doped waveguide. PM-567 doped waveguide pumped with CW Ar(+) laser (514 nm wavelength) far below threshold (0.1 W/sq.cm pump power) demonstrated emission spectrum narrowing near 616 nm peak with 18% power conversion slope efficiency. In this case emission spectrum modification was caused by the enhanced light absorption along the direction of propagating waveguide modes. Changing length, thickness, and other morphlogical waveguide parameters one can modify emission spectrum in predictable direction. The results show that polymeric waveguides, especially based on high temperature polymers such as Pl, can be used to produce a varietiy of active and passive silicon compatible integrated optical components for aerospace applications.

Sarkisov, Sergey↗

SEP Forecasting from the Lunar Gateway

The European Radiation Sensor Array (ERSA) planned to fly onboard the Gateway lunar space station will include a Standard Radiation Environment Monitor (SREM) energetic particle detector. The SREM detector has a long heritage and has flown aboard the Earth-orbiting INTEGRAL and PROBA-1 satellites, the L2 experiments Herschel and Planck, and the inner solar system mission Rosetta. SREM measures energetic protons between 11 – 250 MeV, enabling it to detect proton and electron enhancements due to solar energetic particle (SEP) events, which are potentially hazardous for humans and hardware in space. The UMASEP model, developed by Marlon Nuñez at the University of Malaga, ingests energetic particle measurements to produce forecasts of time to threshold crossing and the maximum flux expected within a certain time window. UMASEP is a mature model that has been running in real time for many years and has demonstrated forecasting skill. We plan to develop a UMASEP-Gateway >30 MeV forecast module using historical INTEGRAL/SREM data so that the model may begin forecasting as soon as ERSA begins returning real time data. UMASEP-Gateway will use the environment at the habitat to produce forecasts. This work will enable forecasting using the in situ environment at the spacecraft and will additionally act as a first step towards producing SEP forecasts directly at the vehicle where humans reside, a key capability that will be needed for exploration missions beyond the Moon.

space weather↗

Polarization and Centre-of-mass Energy Calibration at FCC-ee

The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm) measurements of the W and Z masses and widths, as well as forward-backward asymmetries. To this effect the centre-of-mass energy distribution should be determined with the high precision. This document describes the capacity offered by FCC-ee, starting with transverse polarization of the beams around the Z pole and the W pair threshold. A running scheme based on regular measurements of the beam energy by resonant depolarization of pilot bunches, during physics data taking, is proposed. The design for polarization wigglers, polarimeter and depolarizer is outlined. The $e^\pm$ beam energies will be monitored with a relative precision of $10^{-6}$. The centre-of-mass energy is derived subject to further corrections, related to the beam acceleration, synchrotron radiation and beamstrahlung; these effects are identified and evaluated. Dimuon events $e^+e^- \to \mu^+ \mu^-$, recorded in the detectors, provide with great precision the beam crossing angle, the centre-of-mass energy spread, and the $e^+$ and $e^-$ energy difference. Monitoring methods to minimize absolute error and relative uncertainties are discussed. The impact on the physics measurements is given. A programme of further simulations, design, monitoring and R&D is outlined.

43 PARTICLE ACCELERATORS↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Spectroscopy Detector Candidates and Radioisotope Identification Algorithms for Use in National Security Applications

In 2006, the United States Congress mandated for the Department of Homeland Security (DHS) to screen all cargo containers to protect against terrorist acts and ensure the safety and security of the nation. Containers are screened by gamma and neutron detectors to ensure threat material is not smuggled into the country. However, because commerce is radioactive, detecting the presence of radioactive materials is not sufficient in ensuring the safety and security of the nation. Radioactive materials must also be identified in real time, thus distinguishing threat sources (Uranium-235 and Plutonium-230) from non-threat sources (kitty litter, pot ash, medical isotopes). Screening cargo containers can be considered a two-step process (1) alerting to the presence of radioactive material when gamma counts exceed a threshold setting, and (2) once alerted, identifying the type of radioactive material, which is done by collecting a gamma spectra and analyzing it with an analysis tool/algorithm. For this reason, it is important to evaluate not only emerging technology in neutron and gamma detection, but also investigate new advances in algorithm development for radioisotope identification (RIID). New candidates in detection and on-board algorithm analysis might offer opportunities to make the scanning, detection, and identification process more efficient while still ensuring the health and safety of the public. This research will investigate emerging technology in radiation detection focused on gamma spectroscopy capabilities and RIID algorithms for DHS applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental study of frequency multipliers based on a GaAs/AlAs semiconductor superlattices in the terahertz frequency range

Frequency multipliers based on a GaAs/AlAs semiconductor quantum superlattice have been experimentally studied. The power spectrum of the harmonics in the output signal from a multiplier with an input-signal frequency of 140-160 GHz has been measured. Planar diodes with a small active region (an area of 1-2 {mu}m{sup 2}) have been used in this study. For fabrication of the diodes, structures of heavily doped superlattices with the miniband width 24 meV have been used, these structures were grown by the molecular-beam epitaxy method. Measurements have been conducted using a BOMEM DA3.36 Fourier spectrometer equipped with a detector based on a bolometer cooled to the temperature of liquid helium. The results of the measurements have been used to plot the dependences of the power of the harmonics on the frequency in the range from 0.4 to 8.1 THz. It has been found that the character of the microwave-power distribution over the number of harmonics is close to the spectrum of a sequence of sign-alternating pulses which appear in the diode circuit when the applied voltage of the input signal exceeds the threshold of the diode. The minimal time of establishment of the pulse front and pulse duration are equal to 123 and 667 fs, respectively.

36 MATERIALS SCIENCE↗

Solar Neutrino Observations at the Sudbury Neutrino Observatory

The Sudbury Neutrino Observatory (SNO) is a 1000-tonne heavy water Cherenkov detector. Its usage of \dto as target allows the simultaneous measurements of the $\nu_e$ flux from $^8$B decay in the Sun and the total flux of all active neutrino species through the charged-current and the neutral-current interactions on the deuterons. Assuming the standard $^{8}$B shape, the $\nu_e$ component of the $^{8}$B solar neutrino flux is measured to be $\phi_e = 1.76^{+0.05}_{-0.05}{(stat.)}^{+0.09}_{-0.09} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$ for a kinetic energy threshold of 5 MeV. The non-\nue component is found to be Φ μτ $\= 3.41^{+0.45}_{-0.45}{(stat.)}^{+0.48}_{-0.45} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$. This $5.3\sigma$ difference provides strong evidence for $\nu_{e}$ flavor transformation in the solar neutrino sector. The total active neutrino flux is measured with the neutral-current reaction at a neutrino energy threshold of 2.2 MeV. This flux is determined to be $\phi_{NC} = 5.09^{+0.44}_{-0.43}{(stat.)}^{+0.46}_{-0.43} {(syst.)} x 10^6 {\rm cm}^{-2} {\rm s}^{-1}$, and is consistent with solar model predictions. Assuming an undistorted $^8$B spectrum, the night minus day rate is 14.0$\pm$6.3(stat.)$^{+1.5}_{-1.4}$(sys.)\% of the average rate in the charged-current channel. If the total active neutrino flux is constrained to have no asymmetry, the night-day asymmetry in the $\nu_e$ flux is found to be 7.0$\pm$4.9(stat.)$^{+1.3}_{1.2}$(sys.)\%. A global analysis of all the available solar neutrino data in terms of matter-enhanced oscillations of two active flavors strongly favors the Large Mixing Angle (LMA) solution.

Poon, A. W. P.↗

Gamma Bang Time/Reaction History Diagnostics for the National Ignition Facility (NIF) Using 90-degree Off-axis Parabolic Mirrors

Gas Cherenkov detectors (GCD) have been used to convert fusion gamma into photons to achieve gamma bang time (GBT) and reaction history measurements. The GCD designed for Omega used Cassegrain reflector optics in order to fit inside a ten-inch manipulator. A novel design for the National Ignition Facility (NIF) using 90º Off-Axis Parabolic (OAP) mirrors will increase light collection efficiency from fusion gammas and achieve minimum time dispersion. The broadband Cherenkov light (from 200 to 800 nm) is relayed into a high-speed detector using three parabolic mirrors. Because light is collected from many source planes throughout the CO2 gas volume, the detector is positioned at the stop position rather than an image position. The stop diameter and its position are independent of the light-generation location along the gas cell. The current design collects light from a 100-mm diameter by 500-mm-long gas volume. Optical ray tracings demonstrate how light can be collected from different angled trajectories of the Compton electrons as they fly through the CO2 gas volume. A cluster of four channels will allow for increased dynamic range as well as different gamma energy threshold sensitivities. 52.70.La, 29.40.Ka, 42.15.Eq, 07.60.-j, 07.85.-m

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Bang Time/Reaction History Diagnostics for the National Ignition Facility (NIF) Using 90-degree Off-axis Parabolic Mirrors

Gas Cherenkov detectors (GCD) have been used to convert fusion gamma into photons to achieve gamma bang time (GBT) and reaction history measurements. The GCD designed for Omega used Cassegrain reflector optics in order to fit inside a 10-inch manipulator. A novel design for the National Ignition Facility (NIF) using 90º off-axis parabolic (OAP) mirrors will increase light collection efficiency from fusion gammas and achieve minimum time dispersion. The broadband Cherenkov light (from 200 to 800 nm) is relayed into a high-speed detector using three parabolic mirrors. Because light is collected from many source planes throughout the CO2 gas volume, the detector is positioned at the stop position rather than an image position. The stop diameter and its position are independent of the light-generation location along the gas cell. The current design collects light from a 100-mm-diameter by 500-mm-long gas volume. Optical ray tracings demonstrate how light can be collected from different angled trajectories of the Compton electrons as they fly through the CO2 gas volume. A cluster of four channels will allow for increased dynamic range, as well as different gamma energy threshold sensitivities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermion WIMPless dark matter at DeepCore and IceCube

We investigate the prospects for indirect detection of fermion WIMPless dark matter at the neutrino telescopes IceCube and DeepCore. The dark matter annihilating in the Sun is a hidden sector Majorana fermion that couples through Yukawa couplings to a connector particle and a visible sector particle, and it exhibits only spin-dependent scattering with nuclei via couplings to first generation quarks. We consider cases where the annihilation products are taus, staus, or sneutrinos of the three generations. To evaluate the muon fluxes incident at the detector, we propagate the neutrino spectra through the solar medium and to the Earth and account for the effects of neutrino oscillations, energy losses due to neutral- and charged-current interactions, and tau regeneration. We find that for the stau and sneutrino channels, a 5 yr 3{sigma} detection of dark matter lighter than about 300 GeV is possible at IceCube for large Yukawa couplings or for dark matter and connector particles with similar masses. The tau channel offers far better detection prospects. However, due to its lower energy threshold and better muon background rejection capability, DeepCore is able to detect signals in all annihilation channels and for a wider range of dark matter masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring numerical blow-up phenomena for the Keller–Segel–Navier–Stokes equations

The Keller–Segel–Navier–Stokes system governs chemotaxis in liquid environments. This system is to be solved for the organism and chemoattractant densities and for the fluid velocity and pressure. It is known that if the total initial organism density mass is below 2π there exist globally defined generalised solutions, but what is less understood is whether there are blow-up solutions beyond such a threshold and its optimality. Motivated by this issue, a numerical blow-up scenario is investigated. Approximate solutions computed via a stabilised finite element method founded on a shock capturing technique are such that they satisfy a priori bounds as well as lower and L 1 (Ω) bounds for the organism and chemoattractant densities. In particular, these latter properties are essential in detecting numerical blow-up configurations, since the non-satisfaction of these two requirements might trigger numerical oscillations leading to non-realistic finite-time collapses into persistent Dirac-type measures. Our findings show that the existence threshold value 2π encountered for the organism density mass may not be optimal and hence it is conjectured that the critical threshold value 4π may be inherited from the fluid-free Keller–Segel equations. Additionally it is observed that the formation of singular points can be neglected if the fluid flow is intensified.

97 MATHEMATICS AND COMPUTING↗

Search for an H -Dibaryon with a Mass near 2 m Λ in Υ ( 1 S ) and Υ ( 2 S ) Decays

We report the results of a high-statistics search for H-dibaryon production in inclusive Y(1S) and Y(2S) decays. No indication of an H-dibaryon with mass near the M H =2m Λ threshold is seen in either the H-> Λpπ - or ΛΛ decay channels and 90% confidence level branching-fraction upper limits are set that are between one and two orders of magnitude below the measured branching fractions for inclusive Y(1S) and Y(2S) decays to antideuterons. Since Y(1,2S) decays produce flavor-SU(3)-symmetric final states, these results put stringent constraints on H-dibaryon properties. The results are based on analyses of 102 million Y(1S) and 158 million Y(2S) events collected with the Belle detector at the KEKB electron-positron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation↗

SU-C-206-01: Impact of Charge Sharing Effect On Sub-Pitch Resolution for CZT-Based Photon Counting CT Systems

Purposes: Photon counting CT is a new imaging technology that can provide tissue composition information such as calcium/iodine content quantification. Cadmium zinc telluride CZT is considered a good candidate the photon counting CT due to its relatively high atomic number and band gap. One potential challenge is the degradation of both spatial and energy resolution as the fine electrode pitch is deployed (<50 µm). We investigated the extent of charge sharing effect as functions of gap width, bias voltage and depth-of-interaction (DOI). Methods: The initial electron cloud size and diffusion process were modeled analytically. The valid range of charge sharing effect refers to the range over which both signals of adjacent electrodes are above the triggering threshold (10% of the amplitude of 60keV X-ray photons). The intensity ratios of output in three regions (I1/I2/I3: left pixel, gap area and right pixel) were calculated. With Gaussian white noises modeled (a SNR of 5 based upon the preliminary experiments), the sub-pitch resolution as a function of the spatial position in-between two pixels was studied. Results: The valid range of charge sharing increases linearly with depth-of-interaction (DOI) but decreases with gap width and bias voltage. For a 1.5mm thickness CZT detector (pitch: 50µm, bias: 400 V), the range increase from ∼90µm up to ∼110µm. Such an increase can be attributed to a longer travel distance and the associated electron cloud broadening. The achievable sub-pitch resolution is in the range of ∼10–30µm. Conclusion: The preliminary results demonstrate that sub-pixel spatial resolution can be achieved using the ratio of amplitudes of two neighboring pixels. Such ratio may also be used to correct charge loss and help improve energy resolution of a CZT detector. The impact of characteristic X-rays hitting adjacent pixels (i.e., multiple interaction) on charge sharing is currently being investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature dependence of APD-based PET scanners

Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/°C , R = −0.96) temperature changes. Count rate evaluation showed that although the total count rate is consistently higher at 21 °C than at 24 °C for different source activity concentrations, this is mainly due to an increase in scattered and random coincidences. The peak total count rate is 400 kcps at both temperatures but is reached at lower activity at 21 °C. The peak true count rate is 138 kcps (at 100 MBq) at 21 °C and 180 kcps (at 125 MBq) at 24 °C. The peak noise equivalent count rate is also lower at 21 °C (70 kcps at 70 MBq) than at 24 °C (100 kcps at 100 MBq). At realistic activity levels, the scatter fraction is lower at higher temperatures, but at the cost of a strong decrease in true count rate.Conclusions: A model was proposed for the temperature dependence of APD-based PET scanners and evaluated using the LabPET small animal PET scanner. System sensitivity and count rate performance are strongly dependent on ambient temperature while system resolution is not. The authors’ results indicate that it is important to assure stable ambient temperature to obtain reproducible results in imaging studies with APD-based PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MicroBooNE Electron Neutrino Cross Sections without Visible Pions

MicroBooNE is an 85-tonne liquid argon time projection chamber (LArTPC) at Fermilab. It collected data from two different beam lines between 2015 and 2020 and has since released a large number of neutrino cross section results on argon. These inform neutrino interaction modelling in view of next generation LArTPCs such as the upcoming DUNE experiment. We present new measurements of the electron neutrino charged current pionless cross section on argon in the MicroBooNE detector. These measurements are essential to DUNE’s oscillation analysis as they impact the predicted interaction rate of the main flavor appearance signal. Two measurements are presented, one that leverages the full on-axis MicroBooNE Booster Neutrino Beam dataset while the other uses about 30% of the 8° off-axis Neutrino at the Main Injector beam dataset. Two channels can be considered: with or without a visible pion in the final state. Both measurements consider events with visible protons and the BNB measurement also measures electron neutrinos across the proton visibility threshold. Differential cross sections are extracted in proton and electron kinematics. The relationship between the hadronic and leptonic systems is explored through the angle between the proton and electron directions. The resulting cross sections are compared to a variety of generator predictions using different models of neutrino interactions. We find overall good agreement with most models, especially in lepton kinematics.

Mellet, Lucile [Michigan State U.]↗

Tracking performance and cycle slipping in the all-digital symbol synchronizer loop of the block 5 receiver

Computer simulated noise performance of the symbol synchronizer loop (SSL) in the Block 5 receiver is compared with the theoretical noise performance. Good agreement is seen at the higher loop SNR's (SNR(sub L)'s), with gradual degradation as the SNR(sub L) is decreased. For the different cases simulated, cycle slipping is observed (within the simulation time of 10(exp 4) seconds) at SNR(sub L)'s below different thresholds, ranging from 6 to 8.5 dB, comparable to that of a classical phase-locked loop. An important point, however, is that to achieve the desired loop SNR above the seemingly low threshold to avoid cycle slipping, a large data-to-loop-noise power ratio, P(sub D)/(N(sub 0)B(sub L)), is necessary (at least 13 dB larger than the desired SNR(sub L) in the optimum case and larger otherwise). This is due to the large squaring loss (greater than or equal to 13 dB) inherent in the SSL. For the special case of symbol rates approximately equaling the loop update rate, a more accurate equivalent model accounting for an extra loop update period delay (characteristic of the SSL phase detector design) is derived. This model results in a more accurate estimation of the noise-equivalent bandwidth of the loop.

Aung, M.↗