Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Monocrystalline silicon gradiometer for gravity experiments in space

A very important research effort has been made in the last decade in the field of high precision measurement with laser instrumentation. The development of a space borne gradiometer operating at a high sensitivity level using laser measurement of the distance between proof mass over a short base line of order one meter is discussed. Two aspects of laser technology make it a promising tool for gradiometry measurements: quantum limited accuracy and absolute distance measurements. The quantum limit associated with laser instrumentation was formulated. The relevant quantum and classical sources of errors in laser measurements were reviewed and corresponding laser performance requirements for gradient measurements were evaluated. Some mechanical quality factor measurements were made on simple resonant monocrystalline silicon suspensions. It was discovered that the use of zero derivative restoring forces to position the gradiometer test masses will dramatically reduce the gradiometer temperature control requirements. A laser beam side injection scheme was discovered which permits rejection of common mode accelerations. These concepts are briefly discussed.

Richard, Jean-Paul↗

Food production and gas exchange system using blue-green alga (spirulina) for CELSS

In order to reduce the cultivation area required for the growth of higher plants in space adoption of algae, which have a higher photosynthetic ability, seems very suitable for obtaining oxygen and food as a useful source of high quality protein. The preliminary cultivation experiment for determining optimum cultivation conditions and for obtaining the critical design parameters of the cultivator itself was conducted. Spirulina was cultivated in the 6 liter medium containing a sodium hydrogen carbonate solution and a cultivation temperature controlled using a thermostat. Generated oxygen gas was separated using a polypropyrene porous hollow fiber membrane module. Through this experiment, oxygen gas (at a concentration of more than 46 percent) at a rate of 100 to approx. 150 ml per minute could be obtained.

Oguchi, Mitsuo↗

Nucleate pool boiling: High gravity to reduced gravity; liquid metals to cryogens

Requirements for the proper functioning of equipment and personnel in reduced gravity associated with space platforms and future space station modules introduce unique problems in temperature control; power generation; energy dissipation; the storage, transfer, control and conditioning of fluids; and liquid-vapor separation. The phase change of boiling is significant in all of these. Although both pool and flow boiling would be involved, research results to date include only pool boiling because buoyancy effects are maximized for this case. The effective application of forced convection boiling heat transfer in the microgravity of space will require a well grounded and cogent understanding of the mechanisms involved. Experimental results are presented for pool boiling from a single geometrical configuration, a flat surface, covering a wide range of body forces from a/g = 20 to 1 to a/g = 0 to -1 for a cryogenic liquid, and from a/g = 20 to 1 for water and a liquid metal. Similarities in behavior are noted for these three fluids at the higher gravity levels, and may reasonably be expected to continue at reduced gravity levels.

Merte, Herman, Jr.↗

Dendritic solidification under microgravity conditions

The Isothermal Dendritic Growth Experiment is undergoing development in cooperation with NASA-Lewis in order to test dendritic growth theory at small supercoolings in low earth orbit. The apparatus encompasses four major subsystems: a temperature-controlled thermostatic bath capable of millikelvin stability, a photographic data collection system, a crystal-growth chamber, and a start-detection system which initiates data collection. Comparisons are made with ground-based study methods for dendritic growth.

Glicksman, M. E.↗

Collisional properties of ice spheres at low impact velocities

The results of experimental studies on the impact properties of water ice are discussed. Stable temperatures of 85 K and pressures as low as 10 to the -5th Torr were achieved using a new apparatus consisting of a compound disk pendulum and a stainless steel, temperature-controlled cryostat. The coefficient of restitution as a function of velocity was obtained for ice spheres with four different radii of curvature and with a variety of surface conditions. These data can be well fitted by an exponetial law epsilon of given form for most measurements. Surface conditions can drastically alter the resulting value of epsilon, however. In particular, the presence of frost or a roughened contact surface can lower epsilon at a given velocity by 10-30 percent from that of a smooth sphere. It is shown how the presence of frost can change the velocity behavior of epsilon from an exponential to a power-law form. The applications of the results to the dynamics of Saturn's rings are discussed.

Hatzes, Artie P.↗

Nucleation and particle coagulation experiments in microgravity

Measurements of the conditions under which carbon, aluminum oxide, and silicon carbide smokes condense and of the morphology and crystal structure of the resulting grains are essential if the nature of the materials ejected into the interstellar medium and the nature of the grains which eventually became part of the proto solar nebular are to be understood. Little information is currently available on the vapor-solid phase transitions of refractory metals and solids. What little experimental data do exist are, however, not in agreement with currently accepted models of the nucleation process for more volatile materials. The major obstacle to performing such experiments in earth-based laboratories is the susceptibility of these systems to convection. Evaporation of refractory materials into a low-pressure environment with a carefully controlled temperature gradient will produce refractory smokes when the critical supersaturation of the system is exceeded. Measurement of the point at which nucleation occurs, via light scattering or extinction, can not only yield nucleation data but also, information on the chemical composition and crystal structure of the condensate. Experimental requirements are presented.

Nuth, J.↗

High capacity demonstration of honeycomb panel heat pipes

The feasibility of performance enhancing the sandwich panel heat pipe was investigated for moderate temperature range heat rejection radiators on future-high-power spacecraft. The hardware development program consisted of performance prediction modeling, fabrication, ground test, and data correlation. Using available sandwich panel materials, a series of subscale test panels were augumented with high-capacity sideflow and temperature control variable conductance features, and test evaluated for correlation with performance prediction codes. Using the correlated prediction model, a 50-kW full size radiator was defined using methanol working fluid and closely spaced sideflows. A new concept called the hybrid radiator individually optimizes heat pipe components. A 2.44-m long hybrid test vehicle demonstrated proof-of-principle performance.

Tanzer, H. J.↗

Flight hardware and tele-operations supporting the Isothermal Dendritic Growth Experiment aboard the Space Shuttle

The Isothermal Dendritic Growth Experiment, which is expected to fly on the Space Shuttle to study dendritic solidification of molten metals such as iron and aluminum, is examined. Succinonitrile and pivalic acid are substitued for metals to permit visualiztion of dendritic growth. The technical features of the apparatus are described, including temperature control, the photographic system, and slow scan television. The teleoperations techniques for the experiment are discussed in detail.

Winsa, E.↗

A nonventing cooling system for space environment extravehicular activity, using radiation and regenerable thermal storage

This paper outlines the selection, design, and testing of a prototype nonventing regenerable astronaut cooling system for extravehicular activity space suit applications, for mission durations of four hours or greater. The selected system consists of the following key elements: a radiator assembly which serves as the exterior shell of the portable life support subsystem backpack; a layer of phase change thermal storage material, n-hexadecane paraffin, which acts as a regenerable thermal capacitor; a thermoelectric heat pump; and an automatic temperature control system. The capability for regeneration of thermal storage capacity with and without the aid of electric power is provided.

Bayes, Stephen A.↗

Method of preparing radially homogeneous mercury cadmium telluride crystals

Hg(1-x)Cd(x)Te is prepared in an improved directional solidification method in which a precast alloy sample containing predetermined amounts of Hg, Cd, and Te is disposed in a sealed ampule and a furnace providing two controlled temperature zones is translated upward past the ampule to provide melting and resolidification. The present improvement is directed to maintaining the zones at temperatures determined in accordance with a prescribed formula providing a thermal barrier between the zones with a maximum thickness and translating the furnace past the zones at a rate less the 0.31 micron/sec.

Lehoczky, Sandor L.↗

Protein crystal growth in low gravity

The effect of low gravity on the growth of protein crystals and those parameters which will affect growth and crystal quality was studied. The proper design of the flight hardware and experimental protocols are highly dependent on understanding the factors which influence the nucleation and growth of crystals of biological macromolecules. Thus, those factors are investigated and the body of knowledge which has been built up for small molecule crystallization. These data also provide a basis of comparison for the results obtained from low-g experiments. The flows around growing crystals are detailed. The preliminary study of the growth of isocitrate lyase, the crystal morphologies found and the preliminary x ray results are discussed. The design of two apparatus for protein crystal growth by temperature control are presented along with preliminary results.

Feigelson, Robert S.↗

Accuracy analysis of the space shuttle solid rocket motor profile measuring device

The Profile Measuring Device (PMD) was developed at the George C. Marshall Space Flight Center following the loss of the Space Shuttle Challenger. It is a rotating gauge used to measure the absolute diameters of mating features of redesigned Solid Rocket Motor field joints. Diameter tolerance of these features are typically + or - 0.005 inches and it is required that the PMD absolute measurement uncertainty be within this tolerance. In this analysis, the absolute accuracy of these measurements were found to be + or - 0.00375 inches, worst case, with a potential accuracy of + or - 0.0021 inches achievable by improved temperature control.

Estler, W. Tyler↗

High resolution solar spectrometer system for measuring atmospheric constituents

A mid-IR Michelson interferometer capable of obtaining 0.002/cm resolution solar spectra has been developed for balloon use. The interferometer is based on the Bomem self-aligning instrument, and is equipped with a solar tracking system, telemetry, and recording systems, as well as temperature control and gondola orientation. The interferometer has made two successful flights in the 7-14-micron interval up to 40 km. The basic systems are described and sample spectra are presented.

Murcray, Frank J.↗

Advanced air revitalization system modeling and testing

To support manned lunar and Martian exploration, an extensive evaluation of air revitalization subsystems (ARS) is being conducted. The major operations under study include carbon dioxide removal and reduction; oxygen and nitrogen production, storage, and distribution; humidity and temperature control; and trace contaminant control. A comprehensive analysis program based on a generalized block flow model was developed to facilitate the evaluation of various processes and their interaction. ASPEN PLUS was used in modelling carbon dioxide removal and reduction. Several life support test stands were developed to test new and existing technologies for their potential applicability in space. The goal was to identify processes which use compact, lightweight equipment and maximize the recovery of oxygen and water. The carbon dioxide removal test stands include solid amine/vacuum desorption (SAVD), regenerative silver oxide chemisorption, and electrochemical carbon dioxide concentration (EDC). Membrane-based carbon dioxide removal and humidity control, catalytic reduction of carbon dioxide, and catalytic oxidation of trace contaminants were also investigated.

Dall-Baumann, Liese↗

Effects Of Moisture On Zinc Orthotitanate Paint

Report presents results of tests of electrical conductivity and resistance to corrosion of zinc orthotitanate (ZOT) paint. Measured effects of temperature, humidity, and vacuum on ceramic paint. Used as temperature-control coating designed to have low and stable ratio of absorptance to emittance for heat radiation. Helps to prevent buildup of static electric charge and helps to protect electronic circuitry from potentially damaging static discharges.

Mon, Gordon R.↗

Complete the development and construction of a spaceborne hydrogen maser clock

The objective, to complete the development of an engineering model of a spaceborne hydrogen maser, was successfully achieved. A layout of the maser and detail drawings of the physics package was completed during the first 7 months of the contract. A computer model was made for the maser's thermal design. Using numerical computations, heater resistances were established for 7 temperature controlled zones. The physics package includes: a vacuum manifold that houses four sorption pumps capable of scavenging hydrogen for 4 years, a titanium vacuum tank housing the cavity, metallic seals for all vacuum joints, an RF dissociator within the vacuum envelope, a two-layer printed circuit solenoid and four layers of moly-permalloy magnetic shields. Problems were encountered and overcome in the procurements of the PC solenoid and the magnetic shields. After completion of the fabrication of the maser's components, the maser was assembled using these parts and other components made available by SAO, NRL, and NASA from earlier development work. In March, 1990, the vacuum system was assembled, and by May the maser assembly was completed. The magnetic shielding was poor and the shields were removed, reannealed by a local vendor, and the maser was reassembled. The maser began tests in early June and has been oscillating since that time. The test results of the maser are very good and a life test of the maser is being conducted. It is anticipated that the development and construction of a maser to be tested in space under a new contract from NASA's Marshall Space Flight Center will continue.

Vessot, Robert F. C.↗

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.↗

Long-term propellant/material compatibility

More than 400 test capsules containing liquid propellants in contact with metallic and nonmetallic specimens are now approaching twenty years in JPL's temperature controlled storage facility. A testing program is being established for the systematic analysis of at least half of those capsules. In addition, the results are reported of about 40 recent analyses.

Clifford M. Moran↗