Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

A Fundamental Study of Nucleate Pool Boiling Under Microgravity

An experimental study of incipient boiling in short-term microgravity and with a/g = +/- 1 for pool boiling was performed. Calibrated thin gold films sputtered on a smoothly polished quartz surface were used simultaneously for thermal-resistance measurements and heating of the boiling surface. The gold films were used for both transient and quasi-steady heating surface temperature measurements. Two test vessels were constructed for precise measurement and control of fluid temperature and pressure: a laboratory pool boiling vessel for the a/g = +/- 1 experiments and a pool boiling vessel designed for the 131 m free-fall in the NASA Lewis Research Center Microgravity Research Facility for the microgravity tests. Measurements included the heater surface temperature, the pressure near the heating surface, the bulk liquid temperatures. High speed photography (up to 1,000 frames per second) was used in the experiments. With high quality microgravity and the measured initial temperature of the quiescent test fluid, R113, the temperature distribution in the liquid at the moment of boiling inception resulting from an imposed step in heat flux is known with a certainty not possible previously. The types of boiling propagation across the large flat heating surface, some observed here for the first time, are categorized; the conditions necessary for their occurrence are described. Explosive boiling propagation with a striking pattern of small scale protuberances over the entire vapor mass periphery not observed previously at low heat flux levels (on the order of 5 W/cm(exp 2)) is described. For the heater surface with a/g = -1, a step in the heater surface temperature of short duration was imposed. The resulting liquid temperature distribution at the moment of boiling inception was different from that obtained with a step in heat flux.

Ervin, Jamie S.↗

Methods of Viscosity Measurements in Sealed Ampoules

Viscosity of semiconductor and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviated. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution (0.05 arc.sec) angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and non intrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield the viscosity of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods (oscillating cup, transient torque, and resonance) is presented along with the initial test results of the constructed apparatus. Advantages of each of the method are discussed.

Mazuruk, Konstantin↗

Thermally Induced Vibrations of the Hubble Space Telescope's Solar Array 3 in a Test Simulated Space Environment

NASA Goddard Space Flight Center and the European Space Agency (ESA) conducted a disturbance verification test on a flight Solar Array 3 (SA3) for the Hubble Space Telescope using the ESA Large Space Simulator (LSS) in Noordwijk, the Netherlands. The LSS cyclically illuminated the SA3 to simulate orbital temperature changes in a vacuum environment. Data acquisition systems measured signals from force transducers and accelerometers resulting from thermally induced vibrations of the SAI The LSS with its seismic mass boundary provided an excellent background environment for this test. This paper discusses the analysis performed on the measured transient SA3 responses and provides a summary of the results.

Early, Derrick A.↗

An Experimental Study of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

This paper presents a comprehensive experimental study of the loop operating temperature in a loop heat pipe (LHP) which has two parallel evaporators and two parallel condensers. In a single evaporator LHP, it is well known that the loop operating temperature is a function of the heat load, the sink temperature and the ambient temperature. The objective of the present study emphasizes on the stability of the loop operating temperature and parameters that affects the loop operation. Tests results show that the loop operating temperature is a function of the total system heat load, sink temperature, ambient temperature, and beat load distribution between the two evaporators. Under most conditions, only one compensation chamber (CC) contains two-phase fluid and controls the loop operating temperature, and the other CC is completely filled with liquid. Moreover, as the test condition changes, control of the loop operating temperature often shifted from one CC to another. In spite of complex interactions between various components, the test loop has demonstrated very robust operation even during fast transients.

Ku, Jentung↗

Design of a Microgravity Spray Cooling Experiment

An analytical and experimental study was conducted for the application of spray cooling in a microgravity and high-g environment. Experiments were carried out aboard the NASA KC-135 reduced gravity aircraft, which provided the microgravity and high-g environments. In reduced gravity, surface tension flow was observed around the spray nozzle, due to unconstrained liquid in the test chamber and flow reversal at the heat source. A transient analytical model was developed to predict the temperature and the spray heat transfer coefficient within the heated region. Comparison of the experimental transient temperature variation with analytical results showed good agreement for low heat input values. The transient analysis also verified that thermal equilibrium within the heated region could be reached during the 20-25s reduced gravity portion of the flight profile.

Baysinger, Kerri M.↗

Dynamic Response of Control Servo System Installed in NAES-Equipped SB2C-5 Airplane (BuAer No. 83135)

Dynamic--response measurements for various conditions of displacement and rate signal input, sensitivity setting, and simulated hinge moment were made of the three control-surface servo systems of an NAES-equipped remote-controlled airplane while on the ground. The basic components of the servo systems are those of the General Electric Company type G-1 autopilot using electrical signal. sources, solenoid-operated valves, and hydraulic pistons. The test procedures and difficulties are discussed, Both frequency and transient-response data, are presented and comparisons are made. The constants describing the servo system, the undamped natural frequency, and the damping ratio, are determined by several methods. The response of the system with the addition of airframe rate signal is calculated. The transfer function of the elevator surface, linkage, and cable system is obtained. The agreement between various methods of measurement and calculation is considered very good. The data are complete enough and in such form that they may be used directly with the frequency-response data of an airplane to predict the stability of the autopilot-airplane combination.

Smaus, Louis H.↗

Thermal Vacuum Test of Ice as a Phase Change Material Integrated with a Radiator

Water may be used as radiation shielding for Solar Particle Events (SPE) to protect crewmembers in the Lunar Electric Rover (LER). Because the water is already present for radiation protection, it could also provide a mass efficient solution to the vehicle's thermal control system. This water can be frozen by heat rejection from a radiator and used as a Phase Change Material (PCM) for thermal storage. Use of this water as a PCM can eliminate the need for a pumped fluid loop thermal control system as well as reduce the required size of the radiator. This paper describes the testing and analysis performed for the Rover Engineering Development Unit (REDU), a scaled-down version of a water PCM heat sink for the LER. The REDU was tested in a thermal-vacuum chamber at environmental temperatures similar to those of a horizontal radiator panel on the lunar surface. Testing included complete freeze and melt cycles along with scaled transient heat load profiles simulating a 24-hour day for the rover.

Lee, Steve↗

Thermal Vacuum Test of Ice as a Phase Change Material Integrated with a Radiator

Water may be used as radiation shielding for Solar Particle Events (SPE) to protect crewmembers in the Lunar Electric Rover (LER). Because the water is already present for radiation protection, it could also provide a mass efficient solution to the vehicle's thermal control system. This water can be frozen by heat rejection from a radiator and used as a Phase Change Material (PC1V1) for thermal storage. Use of this water as a PCM can eliminate the need for a pumped fluid loop thermal control system as well as reduce the required size of the radiator. This paper describes the testing and analysis performed for the Rover Engineering Development Unit (REDU), a scaled-down version of a water PCM heat sink for the LER. The REDU was tested in a thermal-vacuum chamber at environmental temperatures similar to those of a horizontal radiator panel on the lunar surface. Testing included complete freeze and melt cycles along with scaled transient heat load profiles simulating a 24-hour day for the rover.

Lee, Steve A.↗

Flight-Tested Prototype of BEAM Software

Researchers at JPL have completed a software prototype of BEAM (Beacon-based Exception Analysis for Multi-missions) and successfully tested its operation in flight onboard a NASA research aircraft. BEAM (see NASA Tech Briefs, Vol. 26, No. 9; and Vol. 27, No. 3) is an ISHM (Integrated Systems Health Management) technology that automatically analyzes sensor data and classifies system behavior as either nominal or anomalous, and further characterizes anomalies according to strength, duration, and affected signals. BEAM (see figure) can be used to monitor a wide variety of physical systems and sensor types in real time. In this series of tests, BEAM monitored the engines of a Dryden Flight Research Center F-18 aircraft, and performed onboard, unattended analysis of 26 engine sensors from engine startup to shutdown. The BEAM algorithm can detect anomalies based solely on the sensor data, which includes but is not limited to sensor failure, performance degradation, incorrect operation such as unplanned engine shutdown or flameout in this example, and major system faults. BEAM was tested on an F-18 simulator, static engine tests, and 25 individual flights totaling approximately 60 hours of flight time. During these tests, BEAM successfully identified planned anomalies (in-flight shutdowns of one engine) as well as minor unplanned anomalies (e.g., transient oil- and fuel-pressure drops), with no false alarms or suspected false-negative results for the period tested. BEAM also detected previously unknown behavior in the F- 18 compressor section during several flights. This result, confirmed by direct analysis of the raw data, serves as a significant test of BEAM's capability.

Mackey, Ryan↗

Damage Based Analysis (DBA): Theory, Derivation and Practical Application - Using Both an Acceleration and Pseudo-Velocity Approach

The objective of this presentation is to give a brief overview of the theory behind the (DBA) method, an overview of the derivation and a practical application of the theory using the Python computer language. The Theory and Derivation will use both Acceleration and Pseudo Velocity methods to derive a series of equations for processing by Python. We will take the results and compare both Acceleration and Pseudo Velocity methods and discuss implementation of the Python functions. Also, we will discuss the efficiency of the methods and the amount of computer time required for the solution. In conclusion, (DBA) offers a powerful method to evaluate the amount of energy imparted into a system in the form of both Amplitude and Duration during qualification testing and flight environments. Many forms of steady state and transient vibratory motion can be characterized using this technique. (DBA) provides a more robust alternative to traditional methods such Power Spectral Density (PSD) using a Maximax approach.

Pseudo Velocity↗

Damage Based Analysis (DBA) - Theory, Derivation and Practical Application Using Both an Acceleration and Pseudo Velocity Approach

The objective of this presentation is to give a brief overview of the theory behind the (DBA) method, an overview of the derivation and a practical application of the theory using the Python computer language. The Theory and Derivation will use both Acceleration and Pseudo Velocity methods to derive a series of equations for processing by Python. We will take the results and compare both Acceleration and Pseudo Velocity methods and discuss implementation of the Python functions. Also, we will discuss the efficiency of the methods and the amount of computer time required for the solution. In conclusion, (DBA) offers a powerful method to evaluate the amount of energy imparted into a system in the form of both Amplitude and Duration during qualification testing and flight environments. Many forms of steady state and transient vibratory motion can be characterized using this technique. (DBA) provides a more robust alternative to traditional methods such Power Spectral Density (PSD) using a maximax approach.

Structural Dynamics↗

Autogenous Pressurization of a Cryogenic Tank Using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems.

Cryogenics↗

Autogenous Pressurization of a Cryogenic Tank using Computational Fluid Dynamics

Well-validated simulation tools can be used to predict long-term storage and transfer of cryogenic propellants, which are essential to NASA’s mission plan to return to the Moon and continue to Mars. Autogenous pressurization of propellant tanks is used to supply rocket engine turbopumps with pressurized liquid fuel and oxidizer, preventing cavitation. Additionally, autogenous pressurization can be used to pressurize propellant tanks to support on-orbit propellant transfer. In lieu of expensive tests conducted on-orbit, accurate predictive computational models of these processes can be used to reduce system and propellant mass as well as mission risk. Using simulation tools also reduces the cost of analyzing and developing this technology. This study presents a multiphase computational fluid dynamics model capable of simulating autogenous pressurization of a large cryogenic tank using the commercial code STAR-CCM+. Experimental data from a full-scale tank pressurization test under terrestrial gravity is compared to simulation results using transient error metrics. Comparisons show good agreement and give confidence in using these and other validated simulation tools to develop cryogenic pressurization systems. Note: There is no audio file included or available for this presentation.

cryogenics↗

Transient nucleate pool boiling in microgravity: Some initial results

Variable gravity provides an opportunity to test the understanding of phenomena which are considered to depend on buoyancy, such as nucleate pool boiling. The active fundamental research in nucleate boiling has sought to determine the mechanisms or physical processes responsible for its high effectiveness, manifested by the high heat flux levels possible with relatively low temperature differences. Earlier research on nucleate pool boiling at high gravity levels under steady conditions demonstrated quantitatively that the heat transfer is degraded as the buoyancy normal to the heater surfaced increases. Correspondingly, it was later shown, qualitatively for short periods of time only, that nucleate boiling heat transfer is enhanced as the buoyancy normal to the heater surface is reduced. It can be deduced that nucleate pool boiling can be sustained as a quasi-steady process provided that some means is available to remove the vapor generated from the immediate vicinity of the heater surface. One of the objectives of the research, the initial results of which are presented here, is to quantify the heat transfer associated with boiling in microgravity. Some quantitative results of nucleate pool boiling in high quality microgravity (a/g approximately 10(exp -5)) of 5s duration, obtained in an evacuated drop tower, are presented here. These experiments were conducted as precursors of longer term space experiments. A transient heating technique is used, in which the heater surface is a transparent gold film sputtered on a qua rtz substrate, simultaneously providing the mean surface temperature from resistance thermometry and viewing of the boiling process both from beneath and across the surface. The measurement of the transient mean heater surface temperature permits the computation, by numerical means, of the transient mean heat transfer coefficient. The preliminary data obtained demonstrates that a quasi-steady boiling process can occur in microgravity if the bulk liquid subcooling is sufficiently high and if the imposed heat flux is sufficiently low. This is attributed to suface tension effects at the liquid-vapor-solid junction causing rewetting to take place, sustaining the nucleate boiling. Otherwise, dryout at the heater surface will occur, as observed.

Merte, Herman, Jr.↗

Internal rotor friction instability

The analytical developments and experimental investigations performed in assessing the effect of internal friction on rotor systems dynamic performance are documented. Analytical component models for axial splines, Curvic splines, and interference fit joints commonly found in modern high speed turbomachinery were developed. Rotor systems operating above a bending critical speed were shown to exhibit unstable subsynchronous vibrations at the first natural frequency. The effect of speed, bearing stiffness, joint stiffness, external damping, torque, and coefficient of friction, was evaluated. Testing included material coefficient of friction evaluations, component joint quantity and form of damping determinations, and rotordynamic stability assessments. Under conditions similar to those in the SSME turbopumps, material interfaces experienced a coefficient of friction of approx. 0.2 for lubricated and 0.8 for unlubricated conditions. The damping observed in the component joints displayed nearly linear behavior with increasing amplitude. Thus, the measured damping, as a function of amplitude, is not represented by either linear or Coulomb friction damper models. Rotordynamic testing of an axial spline joint under 5000 in.-lb of static torque, demonstrated the presence of an extremely severe instability when the rotor was operated above its first flexible natural frequency. The presence of this instability was predicted by nonlinear rotordynamic time-transient analysis using the nonlinear component model developed under this program. Corresponding rotordynamic testing of a shaft with an interference fit joint demonstrated the presence of subsynchronous vibrations at the first natural frequency. While subsynchronous vibrations were observed, they were bounded and significantly lower in amplitude than the synchronous vibrations.

Walton, J.↗

Report on Design and Failure Limits of SiC/SiC and FeCrAl ATF Cladding Concepts under RIA

Pellet-cladding mechanical interaction (PCMI) is a possible failure scenario during a postulated reactivity-initiated accident (RIA). This report summarizes fiscal year 2018 research activities that were undertaken to evaluate the PCMI-like hoop strain–driven mechanical response of accident tolerant fuel cladding candidates of silicon carbide fiber/silicon carbide matrix composite (SiC/SiC) and iron–chromium–aluminum (FeCrAl) tube specimens. To achieve various RIA-like conditions, the modified-burst test device developed during fiscal years 2016 and 2017 was used. A heating capability was also added to the system for high-temperature testing of FeCrAl samples.The first section of this report assesses the accuracy of the two-dimensional digital image correlation calculated strain values for tube samples. The speckle patterns are computer generated in a two-dimensional plane, and the generated images were wrapped into a cylindrical surface for the validation using digital image correlation technique on curved geometries. Subsequent sections address the failure behavior of SiC/SiC composites and long-term heat treated and as-drawn FeCrAl alloy tubes at various strain rates relevant to the postulated RIA events. In the last part, the effect of possible design parameters of failure strain and the strain rate are discussed for SiC/SiC composites and FeCrAl alloys during the PCMI phase of RIA.Future work is planned to develop and design safety tests for accident tolerant fuel cladding candidates and the advanced fuel forms with respect to their transient responses. A broader perspective on the mechanical behavior of the unirradiated and irradiated accident tolerant fuel cladding candidates will be developed using the modified-burst test and other mechanical tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Liquid propellant rocket engine combustion simulation with a time-accurate CFD method

Time-accurate computational fluid dynamics (CFD) algorithms are among the basic requirements as an engineering or research tool for realistic simulations of transient combustion phenomena, such as combustion instability, transient start-up, etc., inside the rocket engine combustion chamber. A time-accurate pressure based method is employed in the FDNS code for combustion model development. This is in connection with other program development activities such as spray combustion model development and efficient finite-rate chemistry solution method implementation. In the present study, a second-order time-accurate time-marching scheme is employed. For better spatial resolutions near discontinuities (e.g., shocks, contact discontinuities), a 3rd-order accurate TVD scheme for modeling the convection terms is implemented in the FDNS code. Necessary modification to the predictor/multi-corrector solution algorithm in order to maintain time-accurate wave propagation is also investigated. Benchmark 1-D and multidimensional test cases, which include the classical shock tube wave propagation problems, resonant pipe test case, unsteady flow development of a blast tube test case, and H2/O2 rocket engine chamber combustion start-up transient simulation, etc., are investigated to validate and demonstrate the accuracy and robustness of the present numerical scheme and solution algorithm.

Chen, Y. S.↗