Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Elevating SolTrace's Capabilities for the Next Generation of Concentrating Solar Analysis

SolTrace is an open-source Monte Carlo ray tracing software developed at NREL. SolTrace can characterize concentrating solar thermal (CST) collector optical performance and is CST technology agnostic. Shown in Fig. 1, SolTrace is a foundational tool in NREL's CST system and component modeling suite. SolTrace's generic surface elements can flexibly model novel collector and receiver designs to predict spatial and temporal flux distributions - critical to understand for CST component design, performance prediction, and system integration. Since its initial development, SolTrace has over 1,650 references on Google Scholar, over 9,800 downloads since 2017, and has served the CST research and development community as a benchmark of 3rd party verification. SolTrace provides users with many options for defining surface shape and boundaries. However, SolTrace provides limited documentation which can result in a steep learning curve for new users. Additionally, SolTrace lacks the computational performance required to evaluate optical performance of a CST system over the course of a year and/or iteratively over design parameters in a timely manner. To address this, we are working towards a new release of SolTrace that enables increased computational throughput by implementing ray tracing acceleration structures and enabling GPU parallelization. Additionally, we are working to improve SolTrace's usability, accessibility, and maintainability by (1) automating solar position time-dependent simulation processes, (2) creating general CST collector templates of grouped elements, (3) updating the user interface to better visualize model inputs and outputs, and (4) creating a user support network through forums, "how to" videos, and documentation.

14 SOLAR ENERGY↗

Program Development Tools and Infrastructures: Activities by ASC CSSE/CCE and Partners

Exascale class machines will exhibit a new level of complexity: they will feature an unprecedented number of cores and threads, will most likely be heterogeneous and deeply hierarchical, and offer a range of new hardware techniques (such as speculative threading, transactional memory, programmable prefetching, and programmable accelerators), which all have to be utilized for an application to realize the full potential of the machine. Additionally, users will be faced with less memory per core, fixed total power budgets, and sharply reduced MTBFs. At the same time, it is expected that the complexity of applications will rise sharply for exascale systems, both to implement new science possible at exascale and to exploit the new hardware features necessary to achieve exascale performance. This is particularly true for many of the NNSA codes, which are large and often highly complex integrated simulation codes that push the limits of everything in the system including language features. To overcome these limitations and to enable users to reach exascale performance, users will expect a new generation of tools that address the bottlenecks of exascale machines, that work seamlessly with the (set of) programming models on the target machines, that scale with the machine, that provide automatic analysis capabilities, and that are flexible and modular enough to overcome the complexities and changing demands of the exascale architectures. Further, any tool must be robust enough to handle the complexity of large integrated codes while keeping the user's learning curve low. With the ASC program, in particular the CSSE (Computational Systems and Software Engineering) and CCE (Common Compute Environment) projects, we are working towards a new generation of tools that fulfill these requirements and that provide our users as well as the larger HPC community with the necessary tools, techniques, and methodologies required to make exascale performance a reality.

43 PARTICLE ACCELERATORS↗

UNNT: A novel Utility for comparing Neural Net and Tree-based models

The use of deep learning (DL) is steadily gaining traction in scientific challenges such as cancer research. Advances in enhanced data generation, machine learning algorithms, and compute infrastructure have led to an acceleration in the use of deep learning in various domains of cancer research such as drug response problems. In our study, we explored tree-based models to improve the accuracy of a single drug response model and demonstrate that tree-based models such as XGBoost (eXtreme Gradient Boosting) have advantages over deep learning models, such as a convolutional neural network (CNN), for single drug response problems. However, comparing models is not a trivial task. To make training and comparing CNNs and XGBoost more accessible to users, we developed an open-source library called UNNT (A novel Utility for comparing Neural Net and Tree-based models). The case studies, in this manuscript, focus on cancer drug response datasets however the application can be used on datasets from other domains, such as chemistry.

59 BASIC BIOLOGICAL SCIENCES↗

Scaling Wind Power Innovation Assessment for Rapid Energy Transition with Artificial Intelligence

Planning for energy system decarbonization requires new insights into the potential of renewable technologies, deployed at unprecedented scale, to meet urgent sustainability goals. However, limited scalability of current wind energy research tools restricts characterization of innovation impacts to isolated reference sites, challenging investment and decision making under rapid growth. We demonstrate the transformative potential of artificial intelligence (AI) to inform future technology advancement and energy systems design by leveraging a state-of-the-art surrogate model to conduct a series of fleet-wide wind plant layout optimizations for greater than 6,800 projected U.S. onshore buildout locations. We show how innovative wake steering technology can address an array of barriers to large-scale deployment and integration of wind power. Specifically, wake steering reduces required plant area by an average of 18% and could preserve upwards of 13,000 km2 for future greenfield deployment, potentially easing siting challenges associated with wind energy infrastructure. Further, by enabling reduced turbine spacing and increased energy production, flexible operations of wake steering improve levelized cost of energy, particularly for large plants and in land-constrained settings. Finally, optimizations that consider dynamic energy prices can deliver increased power production and revenue capture during high-value (often low-wind) periods, further bolstering plant economics. Our computationally efficient approach offers a pathway to accelerate nationwide geographic evaluation of innovative technologies.

graph neural networks↗

SU-E-T-81: A Study On Correlation Between Gamma Analysis for Midline and Lateralized Tumors Using VMAT

Purpose: To evaluate the fluence for the midline and lateralized tumors for VMAT technique using 2D seven29 detector array combined with the Octavius phantom. Methods: 60 cases that are already being treated with volumetric modulated arc therapy (VMAT) have selected for this study. This includes tumors situated at the medial and lateral. Medial refers to the tumor situated at the midline of the body and lateral means toward the side or away from the midline of the body. Verification plans were created for each treatment plan in Varian Eclipse treatment planning system (version10, Varian medical systems, Palo Alto,CA) with the 2D Seven29 detector array and the Octavius phantom(PTW, Freiburg, Germany). Measurements were performed on a Varian Clinac 2100 iX, linear accelerator equipped with a millennium 120 leaf collimator. Analysis was done by comparing the fluence measured for the tumors situated on the midline and tumors situated laterally. Results: Fluence measured for all the delivered plans were analyzed using Verisoft software (PTW, Freiburg, Germany). The gamma pass percentage for midline tumors were found to be higher compared with the lateralized ones. The standard deviation between gamma values for midline and lateralized tumors is 2.18 and 3.5 respectively. Also the standard deviation between the point doses for midline and lateralized tumors is 0.38 and 0.29 respectively. The average gamma passing rate for midline tumors is 96.55% and for lateralized tumors are 94.94% for 3%DD and 3mm DTA criteria. From the T test, it was found that there is no significant difference between the gamma pass percentage between midline and lateralized tumors with p value of 0.28. Conclusion: There is no particular correlation found in the gamma pass criteria for midline and lateralized tumors.

60 APPLIED LIFE SCIENCES↗

Phase II Final Report Computer Optimization of Electron Guns

This program implemented advanced computer optimization into an adaptive mesh, finite element, 3D, charged particle code. The routines can optimize electron gun performance to achieve a specified current, beam size, and perveance. It can also minimize beam ripple and electric field gradients. The magnetics optimization capability allows design of coil geometries and magnetic material configurations to achieve a specified axial magnetic field profile. The optimization control program, built into the charged particle code Beam Optics Analyzer (BOA) utilizes a 3D solid modeling package to modify geometry using design tables. Parameters within the graphical user interface (currents, voltages, etc.) can be directly modified within BOA. The program implemented advanced post processing capability for the optimization routines as well as the user. A Graphical User Interface allows the user to set up goal functions, select variables, establish ranges of variation, and define performance criteria. The optimization capability allowed development of a doubly convergent multiple beam gun that could not be designed using previous techniques.

43 PARTICLE ACCELERATORS↗

AI Applications to Physics Experiments at Jefferson Lab

We survey how AI/ML is being deployed across Jefferson Lab's experimental and accelerator programs. In EPSCI, Hydra applies computer vision to automate real-time data-quality monitoring across all four experimental halls, replacing manual inspection of hundreds to thousands of histograms per shift. AIEC (AI Experiment Controls) uses ML to stabilize drift chamber gains and is now part of standard CEBAF production running, while AI Optimized Polarization (AIOP) targets autonomous control of polarized targets and photon beam angular alignment. In CASA, cavity fault classification models identify faulted cavities and trip types from waveform data with ~85% and ~78% agreement to labeled data, respectively, and are deployed in production; a separate effort applies LLMs and hybrid search to make the CEBAF operations logbook AI-ready. QCD-focused work includes transformer- and GAN-based generative models for particle-level event simulation, with distributed GAN training scaling studies on Polaris. Additional efforts span ML-on-FPGA for the EIC and a new Data Science Department coordinating anomaly detection, uncertainty quantification, and HPC-scalable ML lab-wide. Collectively, these projects illustrate AI's growing role in improving efficiency across JLab's nuclear physics mission.

Mei, Xinxin [Thomas Jefferson National Accelerator↗

Prime factorization using quantum variational imaginary time evolution

The road to computing on quantum devices has been accelerated by the promises that come from using Shor’s algorithm to reduce the complexity of prime factorization. However, this promise hast not yet been realized due to noisy qubits and lack of robust error correction schemes. Here we explore a promising, alternative method for prime factorization that uses well-established techniques from variational imaginary time evolution. We create a Hamiltonian whose ground state encodes the solution to the problem and use variational techniques to evolve a state iteratively towards these prime factors. We show that the number of circuits evaluated in each iteration scales as \(O(n^{5}d)\) , where n is the bit-length of the number to be factorized and d is the depth of the circuit. We use a single layer of entangling gates to factorize 36 numbers represented using 7, 8, and 9-qubit Hamiltonians. We also verify the method’s performance by implementing it on the IBMQ Lima hardware to factorize 55, 65, 77 and 91 which are greater than the largest number (21) to have been factorized on IBMQ hardware.

97 MATHEMATICS AND COMPUTING↗

Impact Report: Quantum Systems Accelerator

The Quantum Systems Accelerator (QSA) is a U.S. National Quantum Information Science Research Center established in August 2020 and funded by the Department of Energy (DOE) Office of Science. QSA is composed of 15 partner institutions— universities and national laboratories—bringing together pioneers of many of today’s unique quantum information science (QIS) and engineering capabilities. Led by Lawrence Berkeley National Laboratory (Berkeley Lab), with Sandia National Laboratories (Sandia Labs) as the lead partner, 250+ QSA researchers are catalyzing U.S. leadership in a fast-growing field that seeks solutions to the Nation’s and the world’s most pressing problems by harnessing the laws of quantum mechanics.

97 MATHEMATICS AND COMPUTING↗

Effect of Strain on the Resistivity and Thermal Conductivity of High Purity Niobium

High purity niobium (Nb) is a technologically important material for large-scale accelerator and nano-scale quantum computing applications in microwave frequency range. The high thermal conductivity and low resistivity of Nb are critical to the high performance at temperature range of 0.01–4.0 K. The presence of interstitials such as O, N, H, and C act as scattering centers and alter the mean free path, reducing resistivity and thermal conductivity, and contributing significantly to Nb's thermal performance for temperatures of 2.0 K and above. The residual resistivity ratio (RRR), defined as the ratio of the normal state resistivity at 300 K to that at 4.2 K (Nb, T c = 9.2 K), is an accepted direct estimate of the impurity content of fully recrystallized Nb. Complete re-crystallization of Nb is challenging unless very high temperatures are employed, which is often impractical, hence, in practice, dislocation and dislocation structures impact the thermal performance of Nb due to strong phonon scattering contributions. Furthermore, this paper reports on the degradation of thermal conductivity and RRR of high purity Nb large grain, single crystal with fixed impurity, varying strain, and dislocation content levels. Experimental thermal conductivity data fits the Boltzmann transport equation incorporating dislocation density.

36 MATERIALS SCIENCE↗

SU-E-J-53: Dosimetric Evaluation at Volumetric Modulated Arc Therapy for Treatment of Prostate Cancer Using Single Or Double Arcs

Purpose: Evaluate and compare retrospective prostate treatment plan using Volumetric Modulated Arc Therapy (RapidArc™ - Varian) technique with single or double arcs at COI Group. Methods: Ten patients with present prostate and seminal vesicle neoplasia were replanned as a target treatment volume and a prescribed dose of 78 Gy. A baseline planning, using single arc, was developed for each case reaching for the best result on PTV, in order to minimize the dose on organs at risk (OAR). Maintaining the same optimization objectives used on baseline plan, two copies for optimizing single and double arcs, have been developed. The plans were performed with 10 MV photon beam energy on Eclipse software, version 11.0, making use of Trilogy linear accelerator with Millenium HD120 multileaf collimator. Comparisons on PTV have been performed, such as: maximum, minimum and mean dose, gradient dose, as well as the quantity of monitor units, treatment time and homogeneity and conformity index. OARs constrains dose have been evaluated, comparing both optimizations. Results: Regarding PTV coverage, the difference of the minimum, maximum and mean dose were 1.28%, 0.7% and 0.2% respectively higher for single arc. When analyzed the index of homogeneity found a difference of 0.99% higher when compared with double arcs. However homogeneity index was 0.97% lower on average by using single arc. The doses on the OARs, in both cases, were in compliance to the recommended limits RTOG 0415. With the use of single arc, the quantity of monitor units was 10,1% lower, as well as the Beam-On time, 41,78%, when comparing double arcs, respectively. Conclusion: Concerning the optimization of patients with present prostate and seminal vesicle neoplasia, the use of single arc reaches similar objectives, when compared to double arcs, in order to decrease the treatment time and the quantity of monitor units.

60 APPLIED LIFE SCIENCES↗

SU-E-T-348: Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were imported by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.

07 ISOTOPE AND RADIATION SOURCES↗

MemHC: An Optimized GPU Memory Management Framework for Accelerating Many-body Correlation

The many-body correlation function is a fundamental computation kernel in modern physics computing applications, e.g., Hadron Contractions in Lattice quantum chromodynamics (QCD). This kernel is both computation and memory intensive, involving a series of tensor contractions, and thus usually runs on accelerators like GPUs. Existing optimizations on many-body correlation mainly focus on individual tensor contractions (e.g., cuBLAS libraries and others). In contrast, this work discovers a new optimization dimension for many-body correlation by exploring the optimization opportunities among tensor contractions. More specifically, it targets general GPU architectures (both NVIDIA and AMD) and optimizes many-body correlation’s memory management by exploiting a set of memory allocation and communication redundancy elimination opportunities: first, GPU memory allocation redundancy: the intermediate output frequently occurs as input in the subsequent calculations; second, CPU-GPU communication redundancy: although all tensors are allocated on both CPU and GPU, many of them are used (and reused) on the GPU side only, and thus, many CPU/GPU communications (like that in existing Unified Memory designs) are unnecessary; third, GPU oversubscription: limited GPU memory size causes oversubscription issues, and existing memory management usually results in near-reuse data eviction, thus incurring extra CPU/GPU memory communications.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-96: An Analysis of VMAT SBRT Lung Treatment Plans

Purpose: To present an analysis of 218 lung sbrt treatment plans delivered using Varian Eclipse RapidArc software and delivered with Varian linear accelerators. Methods: A retrospective analysis of treatment plans generated using the Varian Eclipse PRO RapidArc VMAT optimization and AAA photon beam calculation algorithms was done for 218 plans delivered using Varian Trilogy and TrueBeam linear accelerators. Some of the patients were enrolled in the RTOG 0813 and RTOG 0915 lung protocols. All of the patients’ plans were optimized using the guidelines outlined by these protocols. The plans presented were normalized so that 95% of the PTV volume received 100% of the prescribed dose. Results: The dose co formality constraints from the RTOG protocols and the number of plans within those constraints were:Tumor dose between 60% of maximum dose and 90% of maximum: 218/218 = 100%.Volume of 105% tumor dose outside put less than 15% of the PTV volume: 218/218 = 100%.Maximum dose 2 cm away from PTV within protocol table guidelines: No minor deviation: 188/218 = 86.2%. No major deviation: 216/218 = 99.1%.Ratio of 50% dose volume to PTV volume less than R50 in protocol table: No minor deviation 148/218 = 67.9%. No major deviation: 213/218 = 97.7%.Percent of lung receiving 20 Gy less than 10% (no minor violation): 218/218 = 100%.99% of PTV receiving at least 90% of the tumor dose: 214/218 = 98.2%. Conclusion: Varian RapidArc VMAT can successfully deliver lung SBRT treatments as outlined in the RTOG 0813 and 0915 protocols. The largest deviations were seen in the R50 constraints for the larger PTV volumes.

60 APPLIED LIFE SCIENCES↗

Using Directional Diffusion Coefficients for Nonlinear Diffusion Acceleration of the First Order SN Equations in Near-Void Regions

The common definition of the diffusion coeffcient as the inverse of three times the transport cross section is not compat- ible with voids. Morel introduced a non-local tensor diffusion coeffcient that remains finite in voids[1]. It can be obtained by solving an auxiliary transport problem without scattering or fission. Larsen and Trahan successfully applied this diffusion coeffcient for enhancing the accuracy of diffusion solutions of very high temperature reactor (VHTR) problems that feature large, optically thin channels in the z-direction [2]. It is demonstrated that a significant reduction of error can be achieved in particular in the optically thin region. Along the same line of thought, non-local diffusion tensors are applied modeling the TREAT reactor confirming the findings of Larsen and Trahan [3]. Previous work of the authors have introduced a flexible Nonlinear-Diffusion Acceleration (NDA) method for the first order S N equations discretized with the discontinuous finite element method (DFEM), [4], [5], [6]. This NDA method uses a scalar diffusion coeffcient in the low-order system that is obtained as the flux weighted average of the inverse transport cross section. Hence, it su?ers from very large and potentially unbounded diffusion coeffcients in the low order problem. However, it was noted that the choice of the diffusion coeffcient does not influence consistency of the method at convergence and hence the di?usion coeffcient is essentially a free parameter. The choice of the di?usion coeffcient does, however, affect the convergence behavior of the nonlinear di?usion iterations. Within this work we use Morel’s non-local di?usion coef- ficient in the aforementioned NDA formulation in lieu of the flux weighted inverse of three times the transport cross section. The goal of this paper is to demonstrate that significant en- hancement of the spectral properties of NDA can be achieved in near void regions. For testing the spectral properties of the NDA with non-local diffusion coeffcients, the periodical horizontal interface problem is used [7]. This problem consists of alternating stripes of optically thin and thick materials both of which feature scattering ratios close to unity.

97 MATHEMATICS AND COMPUTING↗

High-reliability computing for the smarter planet

The geometric rate of improvement of transistor size and integrated circuit performance, known as Moore's Law, has been an engine of growth for our economy, enabling new products and services, creating new value and wealth, increasing safety, and removing menial tasks from our daily lives. Affordable, highly integrated components have enabled both life-saving technologies and rich entertainment applications. Anti-lock brakes, insulin monitors, and GPS-enabled emergency response systems save lives. Cell phones, internet appliances, virtual worlds, realistic video games, and mp3 players enrich our lives and connect us together. Over the past 40 years of silicon scaling, the increasing capabilities of inexpensive computation have transformed our society through automation and ubiquitous communications. In this paper, we will present the concept of the smarter planet, how reliability failures affect current systems, and methods that can be used to increase the reliable adoption of new automation in the future. We will illustrate these issues using a number of different electronic devices in a couple of different scenarios. Recently IBM has been presenting the idea of a 'smarter planet.' In smarter planet documents, IBM discusses increased computer automation of roadways, banking, healthcare, and infrastructure, as automation could create more efficient systems. A necessary component of the smarter planet concept is to ensure that these new systems have very high reliability. Even extremely rare reliability problems can easily escalate to problematic scenarios when implemented at very large scales. For life-critical systems, such as automobiles, infrastructure, medical implantables, and avionic systems, unmitigated failures could be dangerous. As more automation moves into these types of critical systems, reliability failures will need to be managed. As computer automation continues to increase in our society, the need for greater radiation reliability is necessary. Already critical infrastructure is failing too frequently. In this paper, we will introduce the Cross-Layer Reliability concept for designing more reliable computer systems.

43 PARTICLE ACCELERATORS↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗