Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis workflow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Self-driving thin film laboratory: autonomous epitaxial atomic-layer synthesis via real-time computer vision analysis of electron diffraction

Emerging materials science platforms with the ability to make autonomous decisions on the fly are fundamentally changing the outlook and protocols for materials optimization and discovery. Because AI-driven self-navigating schemes can effectively reduce the total number of iterations needed to arrive at the "answer" (i.e. the best stochiometric composition for a desired physical property, optimum materials processing parameters, etc.) by significant margins, they have the potential to revolutionize materials and chemical manufacturing processes at large in research laboratory settings as well as in industrial plants. Here, we demonstrate a successful implementation of real-time closed-loop autonomous navigation of a multi-dimensional materials synthesis parameter space for fabricating phase-pure epitaxial films of a metastable phase of a functional oxide in a combinatorial pulsed laser deposition chamber. Sequential epitaxial growth iterations in search of the optimized recipe to stabilize the desired crystal phase were performed using frame-by-frame quantitative computer vision analysis of reflection high-energy electron diffraction (RHEED) images of the unit-cell level film being deposited. The autonomous scheme regularly resulted in > 30-fold reduction in the number of required experiments compared to a comprehensive mapping of the parameter space. The real-time workflow developed here can be readily extended to a variety of thin film synthesis platforms opening the door for self-driving atomic-level materials design as well as autonomous optimization of semiconductor manufacturing.

36 MATERIALS SCIENCE↗

MOOSE framework enhancements for meshing reactor geometries

MOOSE is an open-source, parallel finite element framework designed to permit rapid development of robust multi-physics modeling capabilities. Under the DOE-NEAMS program, numerous solvers have been developed utilizing the open-source MOOSE framework for multiphysics reactor analysis. These solvers require input finite element meshes representing the discretized geometry. Typically, reactor analysts turn to licensed external tools for creation of reactor geometry meshes. Recently, enhancements have been added to the MOOSE framework to mesh common reactor geometries and improve MOOSE-based application user workflows. Support for hexagonal pins, assemblies, and cores has been added, and Cartesian support has been extended. Options for modeling static and rotating control drums within a hexagonal assembly are now available. Pin, assembly, and plane regions can be identified through automatically applied tags on the mesh called 'reporting IDs' for easier post- processing of physics results. An external open-source triangle routine has been leveraged within MOOSE to mesh core periphery zones. A set of reactor geometry builder routines further streamline the construction of hexagonal and Cartesian cores and include the ability to assign materials to regions during mesh generation. The new meshing routines are available through the MOOSE framework in the open-source 'Reactor' module, and the resulting directly within MOOSE-based applications or exported as Exodus II files for use in other finite element solvers. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assembly and Analysis of Cell-Scale Membrane Envelopes

The march toward exascale computing will enable routine molecular simulation of larger and more complex systems, for example, simulation of entire viral particles, on the scale of approximately billions of atoms-a simulation size commensurate with a small bacterial cell. Anticipating the future hardware capabilities that will enable this type of research and paralleling advances in experimental structural biology, efforts are currently underway to develop software tools, procedures, and workflows for constructing cell-scale structures. Herein, we describe our efforts in developing and implementing an efficient and robust workflow for construction of cell-scale membrane envelopes and embedding membrane proteins into them. A new approach for construction of massive membrane structures that are stable during the simulations is built on implementing a subtractive assembly technique coupled with the development of a structure concatenation tool (fastmerge), which eliminates overlapping elements based on volumetric criteria rather than adding successive molecules to the simulation system. Using this approach, we have constructed two "protocells" consisting of MARTINI coarse-grained beads to represent cellular membranes, one the size of a cellular organelle and another the size of a small bacterial cell. The membrane envelopes constructed here remain whole during the molecular dynamics simulations performed and exhibit water flux only through specific proteins, demonstrating the success of our methodology in creating tight cell-like membrane compartments. Extended simulations of these cell-scale structures highlight the propensity for nonspecific interactions between adjacent membrane proteins leading to the formation of protein microclusters on the cell surface, an insight uniquely enabled by the scale of the simulations. We anticipate that the experiences and best practices presented here will form the basis for the next generation of cell-scale models, which will begin to address the addition of soluble proteins, nucleic acids, and small molecules essential to the function of a cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing EDL-driven reduction mechanisms in binary, ternary, and quaternary fluorinated electrolytes via an integrated MD–DFT–ML framework

Accurately predicting solid electrolyte interphase (SEI) formation requires explicitly resolving the electric double layer (EDL) structure, which deviates significantly from that of the bulk electrolyte. Although an established molecular dynamics (MD) and Density Functional Theory (DFT) framework can model SEI formation by evaluating reduction reactions of local clusters in the EDL, it suffers from a combinatorial computational bottleneck. To overcome this limitation, we introduce a machine-learning-accelerated simulation workflow (MD–DFT–ML), integrating a gradient-boosted regression model trained on EDL composition data to efficiently predict reduction potentials. We apply this framework to seven fluorinated electrolytes comprising fluorinated anions, a fluorinated ester solvent, two types of diluent (ion-solvating ester vs. non-solvating ether), and an FEC additive. The analysis shows that the EDL selectively accumulates cation-binding species; consequently, the non–cation-binding ether diluent rarely enters the EDL and makes minimal contributions to SEI formation. DFT calculations on statistically representative EDL clusters provide reduction potentials and fluorine-release pathways, while the ML model, which substantially reduces the DFT workload, predicts cluster reduction energies with a mean absolute error of 0.1 eV. The combined MD–DFT–ML approach also quantifies contributions from different sources to LiF formation in the SEI. This methodology establishes a generalizable route for multiscale modeling electrolyte and interphase design for next-generation electrochemical energy-storage systems.

DFT-MD-ML workflow↗

WE-G-BRA-07: Analyzing the Safety Implications of a Brachytherapy Process Improvement Project Utilizing a Novel System-Theory-Based Hazard-Analysis Technique

Purpose: To investigate the hazards in cervical-cancer HDR brachytherapy using a novel hazard-analysis technique, System Theoretic Process Analysis (STPA). The applicability and benefit of STPA to the field of radiation oncology is demonstrated. Methods: We analyzed the tandem and ring HDR procedure through observations, discussions with physicists and physicians, and the use of a previously developed process map. Controllers and their respective control actions were identified and arranged into a hierarchical control model of the system, modeling the workflow from applicator insertion through initiating treatment delivery. We then used the STPA process to identify potentially unsafe control actions. Scenarios were then generated from the identified unsafe control actions and used to develop recommendations for system safety constraints. Results: 10 controllers were identified and included in the final model. From these controllers 32 potentially unsafe control actions were identified, leading to more than 120 potential accident scenarios, including both clinical errors (e.g., using outdated imaging studies for planning), and managerial-based incidents (e.g., unsafe equipment, budget, or staffing decisions). Constraints identified from those scenarios include common themes, such as the need for appropriate feedback to give the controllers an adequate mental model to maintain safe boundaries of operations. As an example, one finding was that the likelihood of the potential accident scenario of the applicator breaking during insertion might be reduced by establishing a feedback loop of equipment-usage metrics and equipment-failure reports to the management controller. Conclusion: The utility of STPA in analyzing system hazards in a clinical brachytherapy system was demonstrated. This technique, rooted in system theory, identified scenarios both technical/clinical and managerial in nature. These results suggest that STPA can be successfully used to analyze safety in brachytherapy and may prove to be an alternative to other hazard analysis techniques.

60 APPLIED LIFE SCIENCES↗

High-throughput and high-efficiency sample preparation for single-cell proteomics using a nested nanowell chip

Abstract Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.

59 BASIC BIOLOGICAL SCIENCES↗

A national facility for biological cryo-electron microscopy

This review provides a brief update on the use of cryo-electron microscopy for integrated structural biology, along with an overview of the plans for the UK national facility for electron microscopy being built at the Diamond synchrotron. Three-dimensional electron microscopy is an enormously powerful tool for structural biologists. It is now able to provide an understanding of the molecular machinery of cells, disease processes and the actions of pathogenic organisms from atomic detail through to the cellular context. However, cutting-edge research in this field requires very substantial resources for equipment, infrastructure and expertise. Here, a brief overview is provided of the plans for a UK national three-dimensional electron-microscopy facility for integrated structural biology to enable internationally leading research on the machinery of life. State-of-the-art equipment operated with expert support will be provided, optimized for both atomic-level single-particle analysis of purified macromolecules and complexes and for tomography of cell sections. The access to and organization of the facility will be modelled on the highly successful macromolecular crystallography (MX) synchrotron beamlines, and will be embedded at the Diamond Light Source, facilitating the development of user-friendly workflows providing near-real-time experimental feedback.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring Uncertainty in Moment Estimation for Small Earthquakes in Southern Nevada Using the Coda Envelope Method

Compiling source parameter estimates for small earthquakes is important both for our understanding of earthquake physics and for accurately assessing earthquake hazard. Reliable source parameter estimates are difficult to achieve for small earthquakes, in part due to our inability to accurately model the relevant physical processes at high frequencies. The coda envelope methodology developed by Mayeda and Walter (1996) and Mayeda et al. (2003) can mitigate this concern and estimate the moment of small earthquakes by determining the parameters that control the shape of the S-wave coda envelope while eliminating path effects by minimizing the scatter between seismic stations. Here, we use an open-source implementation of this technique called the Coda Calibration Tool (CCT; Barno, 2017) to calculate CCT-based moment magnitude estimates of small earthquakes (M L 0–3) in the Rock Valley, Nevada, region within the Nevada National Security Site. The Rock Valley data set is of particular interest because it allows us to explore the changes in uncertainties of the coda calibration method with earthquake size and depth. We found that a consistent linear relationship exists between the local magnitude M L and our coda-derived M w estimates for earthquakes as small as M L 0–3, but that current CCT workflows do not accurately characterize very shallow events. We also demonstrate that the epistemic uncertainty in the apparent stress value assumed by the CCT algorithm can influence magnitude estimates of small earthquakes. In conclusion, these results provide valuable insight into the seismicity of this region, and inform future analysis and modeling efforts for nuclear monitoring and seismic hazard.

58 GEOSCIENCES↗

Bloodhound 0.8: A Python package for infrasound data analysis

This report provides details of the algorithms in the Bloodhound package for infrasound data analysis. The report provides a detailed description of the algorithms, general instructions on tuning Bloodhound for different signal types, and a complete listing of all input parameters and the complete output schema. Several Jupyter notebooks are provided with the distribution for illustrating how to use Bloodhound for different workflows.

97 MATHEMATICS AND COMPUTING↗

Corrosion Testing Of Additively Manufactured Stainless Steel 316H In Molten Salt Environments

The development of a new ASTM standard for evaluating the corrosion resistance of additive manufactured (AM) stainless steel (SS) 316H in chloride molten salts is critical for the use of these materials in extreme environments such as molten salt reactors (MSRs). This report pertains to a work package of the Advaned Materials and Manufacturing Technologies (AMMT) developing a systematic methodology to link changes in AM fabrication parameters, namely surface finishing, porosity, microstructure, and chemical heterogeneity, to corrosion performance in NaCl-MgCl2 salt, a proposed secondary coolant for MSRs. During Fiscal Year 2024, Idaho National Laboratory investigators in the AMMT program, utilized SS316H bars, fabricated with laser bed powder fusion at Los Alamos National Laboratory, to establish and optimize the workflow for evaluating these process-to-performance relationships. Standard practices for specimen preparation were established using these specimens, with particular focus on descaling and sectioning methods that align with ASTM guidelines. A comprehensive experimental design for static corrosion testing was developed, with pre- and post-exposure analysis utilizing optical microscopy and scanning electron microscopy. So far standard descaling techniques were optimized, one static corrosion test was conducted on the LANL AM SS316H specimens, and pre- and post-corrosion practices were established. In addition, the work package yielded a review paper on corrosion testing gaps for AM materials in nuclear applications and submitted a proposal for a rapid-turnaround experiment to the Nuclear Science User Facilities Program to investigate the combined effects of proton irradiation and corrosion on AM SS316H. This work package establishes a foundation for evaluating processing-to-performance relationships for AM SS316H in harsh conditions, contributing to the safe and efficient design of components for next-generation nuclear reactors. The creation of a standardized methodology and the generation of relevant publications and future research pathways represent significant strides towards integrating AM materials into critical applications where corrosion resistance is paramount.

36 MATERIALS SCIENCE↗

SU-E-T-421: Failure Mode and Effects Analysis (FMEA) of Xoft Electronic Brachytherapy for the Treatment of Superficial Skin Cancers

Purpose: To perform a failure mode and effects analysis (FMEA) of the process for treating superficial skin cancers with the Xoft Axxent electronic brachytherapy (eBx) system, given the recent introduction of expanded quality control (QC) initiatives at our institution. Methods: A process map was developed listing all steps in superficial treatments with Xoft eBx, from the initial patient consult to the completion of the treatment course. The process map guided the FMEA to identify the failure modes for each step in the treatment workflow and assign Risk Priority Numbers (RPN), calculated as the product of the failure mode’s probability of occurrence (O), severity (S) and lack of detectability (D). FMEA was done with and without the inclusion of recent QC initiatives such as increased staffing, physics oversight, standardized source calibration, treatment planning and documentation. The failure modes with the highest RPNs were identified and contrasted before and after introduction of the QC initiatives. Results: Based on the FMEA, the failure modes with the highest RPN were related to source calibration, treatment planning, and patient setup/treatment delivery (Fig. 1). The introduction of additional physics oversight, standardized planning and safety initiatives such as checklists and time-outs reduced the RPNs of these failure modes. High-risk failure modes that could be mitigated with improved hardware and software interlocks were identified. Conclusion: The FMEA analysis identified the steps in the treatment process presenting the highest risk. The introduction of enhanced QC initiatives mitigated the risk of some of these failure modes by decreasing their probability of occurrence and increasing their detectability. This analysis demonstrates the importance of well-designed QC policies, procedures and oversight in a Xoft eBx programme for treatment of superficial skin cancers. Unresolved high risk failure modes highlight the need for non-procedural quality initiatives such as improved planning software and more robust hardware interlock systems.

60 APPLIED LIFE SCIENCES↗

Reverse engineering environmental metatranscriptomes clarifies best practices for eukaryotic assembly

Abstract Background Diverse communities of microbial eukaryotes in the global ocean provide a variety of essential ecosystem services, from primary production and carbon flow through trophic transfer to cooperation via symbioses. Increasingly, these communities are being understood through the lens of omics tools, which enable high-throughput processing of diverse communities. Metatranscriptomics offers an understanding of near real-time gene expression in microbial eukaryotic communities, providing a window into community metabolic activity. Results Here we present a workflow for eukaryotic metatranscriptome assembly, and validate the ability of the pipeline to recapitulate real and manufactured eukaryotic community-level expression data. We also include an open-source tool for simulating environmental metatranscriptomes for testing and validation purposes. We reanalyze previously published metatranscriptomic datasets using our metatranscriptome analysis approach. Conclusion We determined that a multi-assembler approach improves eukaryotic metatranscriptome assembly based on recapitulated taxonomic and functional annotations from an in-silico mock community. The systematic validation of metatranscriptome assembly and annotation methods provided here is a necessary step to assess the fidelity of our community composition measurements and functional content assignments from eukaryotic metatranscriptomes.

Krinos, Arianna I. (ORCID:0000000197678392)↗

SU-E-T-183: Clinical Quality Assurance Workflow for Dynamic Tumor Tracking Radiation Dose Delivery

Purpose: One of the most important aspects of implementation of new treatment modalities is an ‘end-to-end’ verification of the treatment process. Radiation treatment based on dynamic tracking of a tumor is highly patient-specific, therefore, special attention should be paid to quality assurance of the treatment delivery. Our goal was to design the clinical workflow that ensures accurate delivery of the planned dose using the Dynamic Target Tracking option of VeroTM (BrainLab,MHI) linac. Methods: A patient simulation is designed to include a pre-treatment session to verify whether the system can reliably track the motion of the implanted marker and build the 4D model of the target motion. The external surrogate and target motion patterns are recorded in the ExactracTM log files. In this work, a spectrum of custom marker and external surrogate motion trajectories closely resembling the patient specific motion patterns was used. 1mm thick/11mm long VisicoilTM marker was placed 15 and 20mm from the center of the spherical tissue equivalent target (centroid to centroid distance) in the 4D motion phantom (CIRSTM). 3D conformal (3 mm block margin) SBRT plans were delivered to 2 moving targets in the phantom: 1) 20mm diameter target that allows ion chamber dose measurement and 2) 25mm target that allows using film to measure CAX dose (GafchromicTM EBT3 used). The measured dose was compared to the iPlanTM TPS results using MonteCarlo algorithm (1% variance, Dose-to-water). Results: On average, film shows 98.9% pass using gamma criterion for 2% and 2mm DTA, 94.3% match for 2% and 1 mm DTA, 98% pass for 1% and 2 mm DTA however only 88% points passing for 1% and 1 mm DTA. Ion chamber measurements agreed with the calculation within 1.5%. Conclusion: The clinical QA workflow was designed for SBRT delivery using real-time tumor tracking on VeroTM linac.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 51: An analysis of the effectiveness of automated pre-, post- and intra-treatment auditing of electronic health records

We describe development of automated, web-based, electronic health record (EHR) auditing software for use within our paperless radiation oncology clinic. By facilitating access to multiple databases within the clinic, each patient's EHR is audited prior to treatment, regularly during treatment, and post treatment. Anomalies such as missing documentation, non-compliant workflow and treatment parameters that differ significantly from the norm may be monitored, flagged and brought to the attention of clinicians. By determining historical trends using existing patient data and by comparing new patient data with the historical, we expect our software to provide a measurable improvement in the quality of radiotherapy at our centre.

60 APPLIED LIFE SCIENCES↗

The role of above-code labeling programs in reducing CO 2 e emissions in residential buildings

Residential buildings account for 15 % of total U.S. carbon dioxide (CO 2 ) emissions. Voluntary, above-code labeling programs, such as the ENERGY STAR and Zero Energy Ready Home programs, can play a crucial role in reducing the carbon footprint of the new construction residential building sector by encouraging adoption of more energy-efficient and lower emissions building practices and technologies. It's important for the industry to understand the carbon dioxide equivalent (CO 2 e) and energy cost savings potential of these programs. Here, to estimate the potential CO 2 e emissions savings for homes built to above-code labeling program levels, it is imperative to have reliable and accurate tools for estimating emissions from buildings. The open-source OpenStudio-ERI workflow employs detailed physics-based building energy modeling (BEM) to estimate energy usage and operational CO 2 e emissions. In this study we use the OpenStudio-ERI workflow and regional, time-varying emissions factors from the Cambium database to compare the CO 2 e emissions and energy costs of homes built to performance levels required by these above-code labeling programs relative to homes built to model energy codes. We present the results of our analysis and provide a range of emissions and annual energy cost savings for the above-code labeling programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Open-Source Frequency-Domain Model for Floating Wind Turbine Design Optimization

A new frequency-domain dynamics model has been developed that uses open-source components to efficiently represent a complete floating wind turbine system. The model, called RAFT (Response Amplitudes of Floating Turbines), incorporates quasi-static mooring reactions, strip-theory and potential-flow hydrodynamics, blade-element-momentum aerodynamics, and linear turbine control. The formulation is compatible with a wide variety of support structure configurations and no manual or time-domain preprocessing steps are required, making RAFT very practical in design and optimization workflows. The model is applied to three reference floating wind turbine designs and its predictions are compared with results from time-domain OpenFAST simulations. There is good agreement in mean offsets as well the statistics and spectra of the dynamic response, verifying RAFT’s general suitability for floating wind analysis. Follow-on work will include verification of potential-flow and turbine-control features and application to optimization problems.

17 WIND ENERGY↗

Accelerated Probabilistic Marching Cubes by Deep Learning for Time-Varying Scalar Ensembles

Visualizing the uncertainty of ensemble simulations is challenging due to the large size and multivariate and temporal features of en-semble data sets. One popular approach to studying the uncertainty of ensembles is analyzing the positional uncertainty of the level sets. Probabilistic marching cubes is a technique that performs Monte Carlo sampling of multivariate Gaussian noise distributions for positional uncertainty visualization of level sets. However, the technique suffers from high computational time, making interactive visualization and analysis impossible to achieve. This paper introduces a deep-learning-based approach to learning the level-set uncertainty for two-dimensional ensemble data with a multivariate Gaussian noise assumption. We train the model using the first few time steps from time-varying ensemble data in our workflow. We demonstrate that our trained model accurately infers uncertainty in level sets for new time steps and is up to 170X faster than that of the original probabilistic model with serial computation and 10X faster than that of the original parallel computation.

Han, Mengjiao↗