Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomically precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Nucleon Form Factors from BLAST

The BLAST (Bates Large Acceptance Spectrometer Toroid) experiment has been carried out at the MIT-Bates Linear Accelerator Center to study spin-dependent electron scattering from protons and deuterons with small systematic uncertainties. The experiment used a longitudinally polarized, intense electron beam stored in the Bates South Hall Ring in combination with isotopically pure, highly-polarized internal targets of polarized hydrogen and vector- and tensor-polarized deuterium from an atomic beam source. The BLAST data have been used to extract precise results for the elastic form factor ratios G{sub E}/G{sub M} of the proton and the neutron at low momentum transfer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FOHI-D: An iterative Hirshfeld procedure including atomic dipoles

In this work, a new partitioning method based on the FOHI method (fractional occupation Hirshfeld-I method) will be discussed. The new FOHI-D method uses an iterative scheme in which both the atomic charge and atomic dipole are calculated self-consistently. In order to induce the dipole moment on the atom, an electric field is applied during the atomic SCF calculations. Based on two sets of molecules, the atomic charge and intrinsic atomic dipole moment of hydrogen and chlorine atoms are compared using the iterative Hirshfeld (HI) method, the iterative Stockholder atoms (ISA) method, the FOHI method, and the FOHI-D method. The results obtained are further analyzed as a function of the group electronegativity of Boyd et al. [J. Am. Chem. Soc. 110, 4182 (1988); Boyd et al., J. Am. Chem. Soc. 114, 1652 (1992)] and De Proft et al. [J. Phys. Chem. 97, 1826 (1993)]. The molecular electrostatic potential (ESP) based on the HI, ISA, FOHI, and FOHI-D charges is compared with the ab initio ESP. Finally, the effect of adding HI, ISA, FOHI, and FOHI-D atomic dipoles to the multipole expansion as a function of the precision of the ESP is analyzed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of the spatial resolution in two-photon absorption spectroscopy applied to plasma diagnosis

We report a detailed characterization of the spatial resolution provided by two-photon absorption spectroscopy suited for plasma diagnosis via the 1S-2S transition of atomic hydrogen for optogalvanic detection and laser induced fluorescence (LIF). A precise knowledge of the spatial resolution is crucial for a correct interpretation of measurements, if the plasma parameters to be analysed undergo strong spatial variations. The present study is based on a novel approach which provides a reliable and realistic determination of the spatial resolution. Measured irradiance distribution of laser beam waists in the overlap volume, provided by a high resolution UV camera, are employed to resolve coupled rate equations accounting for two-photon excitation, fluorescence decay and ionization. The resulting three-dimensional yield distributions reveal in detail the spatial resolution for optogalvanic and LIF detection and related saturation due to depletion. Two-photon absorption profiles broader than the Fourier transform-limited laser bandwidth are also incorporated in the calculations. The approach allows an accurate analysis of the spatial resolution present in recent and future measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reconstruction-stabilized epitaxy of LaCoO 3 /SrTiO 3 (111) heterostructures by pulsed laser deposition

Unlike widely explored complex oxide heterostructures grown along [001], the study of [111]-oriented heterointerfaces is very limited thus far. One of the main challenges is to overcome the polar discontinuity that hinders the epitaxy of atomically sharp interfaces. Here, by taking LaCoO 3 /SrTiO 3 (111) as a prototype, we show that the reconstruction, which effectively compensates the surface polarity, can stabilize the epitaxy of the heterostructure with polar discontinuity. A reconstructed substrate surface is prepared, while the growth is controlled to form reconstruction on the film surface. To suppress the chemical diffusion across the interface, the growth is interrupted between each unit cell layer to allow the lattice relaxation at a lowered temperature. In this way, high quality two-dimensional growth is realized and the heterointerfaces exhibit sharpness at the atomic scale. As a result, our work provides a path to precisely control the growth of complex oxide heterostructures along polar orientations that exhibit emergent quantum phenomena.

36 MATERIALS SCIENCE↗

Precision frequency measurements with interferometric weak values

We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 {+-} 7 kHz/{radical}(Hz) with only 2 mW of continuous-wave, single-mode input power. We describe the measurement of a weak value and show how even higher-frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Q Value of {sup 115}In->{sup 115}Sn(3/2{sup +}): The Lowest Known Energy beta Decay

Using precision, cryogenic, Penning-trap mass spectrometry we have measured the atomic mass difference M[{sup 115}In]-M[{sup 115}Sn] to be 497.489(10) keV/c{sup 2}. Combined with the energy of the 3/2{sup +} first excited state of {sup 115}Sn[J. Blachot, Nuclear Data Sheets 104, 967 (2005)], the Q value of the {sup 115}In(9/2{sup +})->{sup 115}Sn(3/2{sup +}) beta decay is determined to be 155(24) eV. This confirms the inference of Cattadori et al.[Nucl. Phys. A 748, 333 (2005)] that this small branching-ratio beta decay has the lowest-known Q value. We also report improved values of the individual atomic masses: M[{sup 115}In]=114.903 878 774(16) u and M[{sup 115}Sn]=114.903 344 697(17) u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Franck-Condon Tuning of Optical Cycling Centers by Organic Functionalization

Laser induced electronic excitations that spontaneously emit photons and decay directly to the initial ground state (“optical cycling transitions”) are used in quantum information and precision measurement for state initialization and readout. To extend this primarily atomic technique to large, organic compounds, we theoretically investigate optical cycling of alkaline earth phenoxides and their functionalized derivatives. We find that optical cycle leakage due to wave function mismatch is low in these species, and can be further suppressed by using chemical substitution to boost the electron-withdrawing strength of the aromatic molecular ligand through resonance and induction effects. This provides a straightforward way to use chemical functional groups to construct optical cycling moieties for laser cooling, state preparation, and quantum measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

Study of Multilayer Thin Film Structures by Rutherford Backscattering Spectrometry

We have evaluated possibilities of using the method of Rutherford backscattering spectrometry (RBS) for depth profiling of multilayer thin-film structures containing nanodmensional layers of elements with close atomic masses. It is established that RBS measurements can ensure high precision determination of the composition of these multilayer structures, total film thickness, and thicknesses of separate layers. This ability can be used for the input quality control of multilayer structures used in micro- and nanotechnologies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Polarization Measurements of p ↑ and 3 He ↑ Beams at RHIC and Future EIC Using the Polarized Atomic Hydrogen Gas Jet Target

At the Relativistic Heavy Ion Collider (RHIC), the Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is employed for the precise measurement of the absolute transverse (vertical) polarization of proton beams, achieving low systematic uncertainties of approximately σ$^{syst}_P$/P≤0.5% . The acquired experimental data not only facilitated the determination of single A N (t) and double A NN (t) spin analyzing powers for 100 and 255 GeV proton beams, but also revealed a non-zero Pomeron spin-flip contribution through a Regge fit. Preliminary results obtained for forward inelastic p ↑ p and elastic p ↑ A analyzing powers will be discussed. The success of the HJET at RHIC suggests its potential application for proton beam polarimetry at the upcoming Electron–Ion Collider (EIC), aiming for an accuracy of 1%. Moreover, the provided analysis indicates that the RHIC HJET target can serve as a tool for the precision calibration, with the required accuracy, of the 3 He beam polarization at the EIC.

3He beam breakup↗

Optical and infrared masers

Ongoing research progress in the following areas is described: (1) tunable infrared light sources and applications; (2) precision frequency and wavelength measurements in the infrared with applications to atomic clocks; (3) zero-degree pulse propagation in resonant medium; (4) observation of Dicke superradiance in optically pumped HF gas; (5) unidirectional laser amplifier with built-in isolator; and (6) progress in infrared metal-to-metal point contact tunneling diodes.

Source record↗

The Rubidium-Crystal Oscillator Hybrid Development Program

The rubidium-crystal oscillator hybrid (RbXO) will make precise time available to systems that lack the power required by atomic frequency standards. The RbXO consists of two subassemblies in separate enclosures. One contains a small rubidium frequency standard (RFS) without its internal oven-controlled crystal oscillator (OCXO), plus interface circuits. The second contains a low-power OCXO, and additional interface circuits. The OCXO is on continuously. Periodically, e.g., once a week, the user system applies power to the RFS. After the few necessary for the warmup of the RFS, the interface circuits adjust the frequency of the OCXO to the RFS reference, then shut off the RFS. The OCXO enclosure is separable from the RFS enclosure so that manpacks will be able to operate with minimum size, weight, and power consumption, while having the accuracy of the RFS for the duration of a mission. A prototype RbXO's RFS has operated successfully for 4200 on-off cycles. Parallel efforts on a Phase 2 RbXO development are in progress. Two sources for the RbXO are scheduled to be available during 1986.

Vig, J. R.↗

Automatic Molecular Design using Evolutionary Techniques

Molecular nanotechnology is the precise, three-dimensional control of materials and devices at the atomic scale. An important part of nanotechnology is the design of molecules for specific purposes. This paper describes early results using genetic software techniques to automatically design molecules under the control of a fitness function. The fitness function must be capable of determining which of two arbitrary molecules is better for a specific task. The software begins by generating a population of random molecules. The population is then evolved towards greater fitness by randomly combining parts of the better individuals to create new molecules. These new molecules then replace some of the worst molecules in the population. The unique aspect of our approach is that we apply genetic crossover to molecules represented by graphs, i.e., sets of atoms and the bonds that connect them. We present evidence suggesting that crossover alone, operating on graphs, can evolve any possible molecule given an appropriate fitness function and a population containing both rings and chains. Prior work evolved strings or trees that were subsequently processed to generate molecular graphs. In principle, genetic graph software should be able to evolve other graph representable systems such as circuits, transportation networks, metabolic pathways, computer networks, etc.

Globus, Al↗

System using leo satellites for centimeter-level navigation

Disclosed herein is a system for rapidly resolving position with centimeter-level accuracy for a mobile or stationary receiver [4]. This is achieved by estimating a set of parameters that are related to the integer cycle ambiguities which arise in tracking the carrier phase of satellite downlinks [5,6]. In the preferred embodiment, the technique involves a navigation receiver [4] simultaneously tracking transmissions [6] from Low Earth Orbit Satellites (LEOS) [2] together with transmissions [5] from GPS navigation satellites [1]. The rapid change in the line-of-sight vectors from the receiver [4] to the LEO signal sources [2], due to the orbital motion of the LEOS, enables the resolution with integrity of the integer cycle ambiguities of the GPS signals [5] as well as parameters related to the integer cycle ambiguity on the LEOS signals [6]. These parameters, once identified, enable real-time centimeter-level positioning of the receiver [4]. In order to achieve high-precision position estimates without the use of specialized electronics such as atomic clocks, the technique accounts for instabilities in the crystal oscillators driving the satellite transmitters, as well as those in the reference [3] and user [4] receivers. In addition, the algorithm accommodates as well as to LEOS that receive signals from ground-based transmitters, then re-transmit frequency-converted signals to the ground.

Rabinowitz, Matthew↗

Optical Injection Locking of a VCSEL in an OEO

Optical injection locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface- emitting laser (VCSEL) that is an active element in the frequency-control loop of an opto-electronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency resonance. This particular optical-injection- locking scheme is expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. Inasmuch as the microwave power circulating in the frequency-control loop is a dynamic frequency-control variable (and, hence, cannot be stabilized), there arises a need for another means of stabilizing the wavelength. The present optical-injection-locking scheme satisfies the need for a means to stabilize the wavelength against microwave- power fluctuations. It is also expected to afford stabilization against temperature and current fluctuations. In an experiment performed to demonstrate this scheme, wavelength locking was observed when about 200 W of the output power of a commercial tunable diode laser was injected into a commercial VCSEL, designed to operate in the wavelength range of 795+/-3 nm, that was generating about 200 microW of optical power. (The use of relatively high injection power levels is a usual practice in injection locking of VCSELs.)

Strekalov, Dmitry↗

Cloud Impacts on Photochemistry: Building a Climatology of Photolysis Rates from the Atmospheric Tomography Mission

Measurements from actinic flux spectroradiometers on board the NASA DC-8 during the Atmospheric Tomography (ATom) mission provide an extensive set of statistics on how clouds alter photolysis rates (J values) throughout the remote Pacific and Atlantic Ocean basins. J values control tropospheric ozone and methane abundances, and thus clouds have been included for more than three decades in tropospheric chemistry modeling. ATom made four profiling circumnavigations of the troposphere capturing each of the seasons during 2016–2018. This work examines J values from the Pacific Ocean flights of the first deployment, but publishes the complete Atom-1 data set (29 July to 23 August 2016). We compare the observed J values (every 3 s along flight track) with those calculated by nine global chemistry– climate/transport models (globally gridded, hourly, for a mid-August day). To compare these disparate data sets, we build a commensurate statistical picture of the impact of clouds on J values using the ratio of J -cloudy (standard, sometimes cloudy conditions) to J -clear (artificially cleared of clouds). The range of modeled cloud effects is inconsistently large but they fall into two distinct classes: (1) models with large cloud effects showing mostly enhanced J values aloft and or diminished at the surface and (2) models with small effects having nearly clear-sky J values much of the time. The ATom-1 measurements generally favor large cloud effects but are not precise or robust enough to point out the best cloud-modeling approach. The models here have resolutions of 50–200 km and thus reduce the occurrence of clear sky when averaging over grid cells. In situ measurements also average scattered sunlight over a mixed cloud field, but only out to scales of tens of kilometers. A primary uncertainty remains in the role of clouds in chemistry, in particular, how models average over cloud fields, and how such averages can simulate measurements.

actinic flux spectroradiometers↗

Applications of Atomic Layer Deposition in the Modification of Carbon Nanotubes

Atomic Layer Deposition (ALD) is a cost-effective nanoadditive-manufacturing technique that allows for conformal coating of substrates with atomic control in a benign temperature and pressure environment. Using paired precursor gases, thin films can be deposited on flat or textured surfaces ranging from glass, polymers, aerogels, and metals. Through atomic layer control, where single layers of atoms are deposited, fabrication of metal transparent films, nano-laminates, and coatings of nano-channels and pores is achievable. Reaction mechanisms in ALD are normally self-limiting, allowing for atomically accurate control of nanometer (nm) thicknesses. Therefore, high uniformity and precise thickness control make ALD an attractive process for the creation of novel nano-scale devices. Decreases in resistivity and density of electrical wire are needed to improve the function of electronics, electric motors and cables. Such improvements may be accomplished by adding ballistically conducting, metallic carbon nanotubes (CNT) to Cu. ALD was used to coat multiple substrates including CNT with Cu in an effort to make CNT-Cu composites which is more conductive and less dense than Cu. In addition, ALD can be used to as a method to deposit the catalyst layer seed layer for CNT growth using Ni. The ALD of copper metallic films can follow multiple reaction pathways depending on the ALD precursors used. For this work the reaction pathway was deposition of copper oxide and then post process annealing in a hydrogen environment. Copper(II) diacetylacetonate (Cu(acac)2) and ozone are used as precursors for copper oxide. As-deposited copper oxide films prepared at 180°C resulted in a growth per cycle of 1.0 A/cycle with low film resistivity.

Dwivedi, Vivek H.↗