Developing Low-Conductance Window Frames: Capabilities and Limitations of Current Window Heat Transfer Design Tools

While window frames typically represent 20-30% of the overall window area, their impact on the total window heat transfer rates may be much larger. This effect is even greater in low-conductance (highly insulating) windows that incorporate very low-conductance glazing. Developing low-conductance window frames requires accurate simulation tools for product research and development. Based on a literature review and an evaluation of current methods of modeling heat transfer through window frames, we conclude that current procedures specified in ISO standards are not sufficiently adequate for accurately evaluating heat transfer through the low-conductance frames. We conclude that the near-term priorities for improving the modeling of heat transfer through low-conductance frames are: (1) Add 2D view-factor radiation to standard modeling and examine the current practice of averaging surface emissivity based on area weighting and the process of making an equivalent rectangular frame cavity. (2) Asses 3D radiation effects in frame cavities and develop recommendation for inclusion into the design fenestration tools. (3) Assess existing correlations for convection in vertical cavities using CFD. (4) Study 2D and 3D natural convection heat transfer in frame cavities for cavities that are proven to be deficient from item 3 above. Recommend improved correlations or full CFD modeling into ISO standards and design fenestration tools, if appropriate. (5) Study 3D hardware short-circuits and propose methods to ensure that these effects are incorporated into ratings. (6) Study the heat transfer effects of ventilated frame cavities and propose updated correlations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructural evolution of type 304 and 316 stainless steels under neutron irradiation at LWR relevant conditions

Extension of light water reactors' useful life will expose austenitic internal core components to irradiation damage levels beyond 100 displacements per atom (dpa), which will lead to profound microstructural evolution and consequent degradation of macroscopic properties. Microstructural evolution, including Frank loops, cavities, precipitates, and segregation at boundaries and the resultant radiation hardening in type 304 and 316 stainless steel (SS) variants, were studied in this work via experimental characterization and multiple simulation methods. Experimental data for up to 40 heats of type 304SS and 316SS variants irradiated in different reactors to 0.6–120 dpa at 275–375°C were either generated from this work or collected from literature reports. These experimental data were then combined with models of Frank loop and cavity evolution, computational thermodynamics and precipitation, and ab initio and rate theory integrated radiation-induced segregation models to provide insights into microstructural evolution and degradation at higher radiation doses.

36 MATERIALS SCIENCE↗

Dose-Volume Relationships for Acute Bowel Toxicity in Patients Treated With Pelvic Nodal Irradiation for Prostate Cancer

Purpose: To find correlation between dose-volume histograms (DVHs) of the intestinal cavity (IC) and moderate-severe acute bowel toxicity in men with prostate cancer treated with pelvic nodal irradiation. Methods and Materials: The study group consisted of 191 patients with localized prostate cancer who underwent whole-pelvis radiotherapy with radical or adjuvant/salvage intent during January 2004 to November 2007. Complete planning/clinical data were available in 175 of these men, 91 of whom were treated with a conventional four-field technique (50.4 Gy, 1.8 Gy/fraction) and 84 of whom were treated with IMRT using conventional Linac (n = 26, 50.4 Gy, 1.8 Gy/fraction) or Helical TomoTherapy (n = 58, 50-54 Gy, 1.8-2 Gy/fraction). The IC outside the planning target volume (PTV) was contoured and the DVH for the first 6 weeks of treatment was recovered in all patients. The correlation between a number of clinical and DVH (V10-V55) variables and toxicity was investigated in univariate and multivariate analyses. The correlation between DVHs for the IC outside the PTV and DVHs for the whole IC was also assessed. Results: Twenty-two patients experienced toxicity (3/22 in the IMRT/tomotherapy group). Univariate analyses showed a significant correlation between V20-V50 and toxicity (p = 0.0002-0.001), with a higher predictive value observed for V40-V50. Previous prostatectomy (p = 0.066) and abdominal/pelvic surgery (p = 0.12) also correlated with toxicity. Multivariate analysis that included V45, abdominal/pelvic surgery, and prostatectomy showed that the most predictive parameters were V45 (p = 0.002) and abdominal/pelvic surgery (p = 0.05, HR = 2.4) Conclusions: Our avoidance IMRT approach drastically reduces the incidence of acute bowel toxicity. V40-V50 of IC and, secondarily, previous abdominal/pelvic surgery were the main predictors of acute bowel toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the Definition of Tumor Bed Boost With the Use of Surgical Clips and Image Registration in Breast Cancer Patients

Purpose: To evaluate the accuracy of a boost technique. Methods and Materials: Twenty-two patients underwent tumorectomy with placement of two or more clips in the surgical cavity before breast remodeling. Preoperative and postoperative computed tomography scans, with match-point registration, were performed on all patients. The relationship between the location of the gross tumor volume (GTV), defined on the preoperative scan, and clip clinical target volume (CTV) (clips with a 5-mm margin on the postoperative scan) was then studied, by use of commercial volume analysis software. Results: Of the patients, 4 had two clips, 2 had three clips, 8 had four clips, and 8 had five clips. The median GTV was 1.06 mL (range, 0.2-5.3 mL); clip CTV ranged from 2.4 to 21.5 mL. Volumetric analysis showed that in 7 cases (32%), there was no intersection between the GTV and the clip CTV, with the following distribution: 4 patients with two clips, 1 patient with three clips, 1 patient with four clips, and 1 patient with five clips. The common contoured volume was defined as the percent ratio between the intersection of the GTV and clip CTV and the GTV. It was found to be significantly increased if three or more clips were used vs. only two clips (common contoured volume, 35.45% vs. 0.73%; p = 0.028). Finally, the GTV and clip CTV volume relationship can be presented as follows: 12.5% to 33% overlap in 8 patients (36.4%), 50% to 75% in 5 patients (22.7%), and greater than 90% in 2 patients (9%). Conclusions: The use of three or more clips during tumorectomy increases the accuracy of tumor bed delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental study of the hydrodynamic trajectory of an x-ray-heated gold plasma

Hydrodynamic processes of radiation-ablated high-Z plasmas have great influence on the x-ray radiation transport both in a high-Z tube with low-Z foam filling and in a low-Z filling indirect drive cavity. Using the intense x-ray radiation to heat a low-Z foam-tamped high-Z gold plate from a half cavity, the hydrodynamic moving process of the x-ray-ablated gold plasma has been studied by an imaging method with Ti He-alpha line emission as the backlighter source. The hydrodynamic trajectory of the x-ray-heated gold plasma was obtained and the average trajectory velocity of (36.5+-1.2) km/s was derived. The experimental trajectory was compared with the simulations using the one-dimensional (1D) RDMG [P. Gu et al., Sci. China, Ser. G 48, 345 (2005)] and two-dimensional (2D) LARED-R [K. Lan et al., Laser Part. Beams 23, 275 (2005)] codes separately. It is shown that the 2D LARED-R code simulated the measured plasma trajectory much better than the 1D RDMG code due to the fact that the lateral x-ray radiation loss was taken into account in the 2D LARED-R but not in the 1D RDMG simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cavitation in a metallic liquid: Homogeneous nucleation and growth of nanovoids

Large-scale molecular dynamics (MD) simulations are performed to investigate homogeneous nucleation and growth of nanovoids during cavitation in liquid Cu. We characterize in detail the atomistic cavitation processes by following the temporal evolution of cavities or voids, analyze the nucleation behavior with the mean first-passage time (MFPT) and survival probability (SP) methods, and discuss the results against classical nucleation theory (CNT), the Tolman equation for surface energy, independent calculation of surface tension via integrating the stress profiles, the Johnson-Mehl-Avrami (JMA) growth law, and the power law for nucleus size distributions. Cavitation in this representative metallic liquid is a high energy barrier Poisson processes, and the steady-state nucleation rates obtained from statistical runs with the MFPT and SP methods are in agreement. The MFPT method also yields the critical nucleus size and the Zeldovich factor. Fitting with the Tolman's equation to the MD simulations yields the surface energy of a planar interface (∼0.9 J m{sup −2}) and the Tolman length (0.4–0.5 Å), and those values are in accord with those from integrating the stress profiles of a planar interface. Independent CNT predictions of the nucleation rate (10{sup 33−34} s{sup −1} m{sup −3}) and critical size (3–4 Å in radius) are in agreement with the MFPT and SP results. The JMA law can reasonably describe the nucleation and growth process. The size distribution of subcritical nuclei appears to follow a power law with an exponent decreasing with increasing tension owing to coupled nucleation and growth, and that of the supercritical nuclei becomes flattened during further stress relaxation due to void coalescence.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type. Conclusions: It is concluded that gadolinium based contrast agents, iron oxide particles, and single walled carbon nanotubes have little intrinsic merit as thermoacoustic contrast agents. Simple electrolytes such as saline which yield high contrast based on ionic conductivity provide much higher dielectric contrast per unit solute concentration and are likely to be significantly more effective as contrast agents.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-537: Prone Breast Accelerated Partial Breast Irradiation Using Non-Coplanar Volumetric Arc Therapy

Purpose: To demonstrate that Volumetric Modulated Arc Therapy (VMAT) can be an alternative technique to Brachytherapy Accelerated Partial Breast Irradiation (APBI) for treating large breasted women. The non-coplanar VMAT technique uses a commercially available couch and a small number of angles. This technique with the patient in the prone position can reduce high skin and critical structure doses in large breasted women, which are usually associated with Brachytherapy APBI. Methods: Philips Pinnacle treatment planning system with Smart Arc was used to plan a left sided laterally located excision cavity on a standard prone breast patient setup. Three thirty-degree arcs entered from the lateral side at respective couch angles of 345, 0, and 15 degrees. A fourth thirty degree arc beam entered from the medial side at a couch angle of 0 degrees. The arcs were selected to avoid critical structures as much as possible. A test run was then performed to verify that the beams did not collide with the patient nor support structures. NSABP B-39/RTOG 0413 protocol guidelines were used for dose prescription, normal tissue, and target definition. Results: Dose Volume Histogram analysis indicated that all parameters were equal or better than RTOG recommendations. Of particular note regarding the plan quality:1.(a) For a prescribed dose of 3850cGy the PTV-EVAL target volume receiving 100 percent of the dose(V100) was 93; protocol recommendation is V90 > 90 percent. (b) Maximum dose was 110 percent versus the allowed 120 percent .2. Uninvolved percentage of normal breast V100 and V50 were 17 and 47 versus allowed 35 and 60 percent respectively.3. For the skin, V100 was 5.7cc and the max dose to 0.1 cc was 4190cGy. Conclusion: Prone Breast non-coplanar VMAT APBI can achieve better skin cosmesis and lower critical structure doses than Brachytherapy APBI.

60 APPLIED LIFE SCIENCES↗

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.↗

Electrostatic disturbance forces on a 3-axis drag-free sensor

The electrostatic analysis of a multiple-capacitance 3-axis drag-free sensor is presented in this paper. The instrument consists of a proof-mass (a dense metallic ball) floating freely inside a spherical cavity enclosed by the sensor plates and the shield. Since the ball and the cavity are not necessarily concentric, the problem in three-dimensional potential theory for electrostatics is solved by the method of boundary perturbations and specifically in terms of spherical harmonics. The capacitance outputs of the instrument and the electrostatic forces acting on the system are derived as non-linear functions of the ball position, ball charge and the sensor plate potentials. The instrument sensitivity and cross-coupling effects are discussed. The analysis may also be useful for electrostatic gyros and suspensions.

Hagstrom, T.↗

Velocity-pressure integrated versus penalty finite element methods for high Reynolds number flows

Velocity-pressure integrated and consistent penalty finite element computations of high Reynolds number, laminar flows are presented. In both of the methods, the pressure has been interpolated using linear shape functions for a triangular element. The triangular element is contained inside the bi-quadratic isoparametric element. It has been reported previously that the pressure interpolation method, when used in the velocity-pressure integrated method, yielded accurate computational results for high Reynolds number flows. It is shown that use of the same pressure interpolation method in the consistent penalty finite element method yielded accurate velocity and pressure fields which were comparable to those obtained using the velocity-pressure integrated method. Accuracy of the two finite element methods has been demonstrated by comparing the computational results with available experimental data and/or fine-grid finite difference computational results. Advantages and disadvantages of the two methods are discussed on the basis of accuracy and convergence nature. Example problems considered include a lid-driven cavity flow for Reynolds number of 10,000, a laminar backward-facing step flow, a laminar flow through a nest of cylinders, and a channel flow with an internal blockage. A finite element computer program (NSFLOW/P) for the 2-D, incompressible Navier-Stokes equations is also presented.

Kim, Sang-Wook↗

Element-by-element and implicit-explicit finite element formulations for computational fluid dynamics

Preconditioner algorithms to reduce the computational effort in FEM analyses of large-scale fluid-dynamics problems are presented. A general model problem is constructed on the basis of the convection-diffusion equation and the two-dimensional vorticity/stream-function formulation of the Navier-Stokes equations; this problem is then analyzed using element-by-element, implicit-explicit, and adaptive implicit-explicit approximation schemes. Numerical results for the two-dimensional advection and rigid-body rotation of a cosine hill, flow past a circular cylinder, and driven cavity flow are presented in extensive graphs and shown to be in good agreement with those obtained using implicit methods.

Tezduyar, T. E.↗

Velocity-pressure integrated versus penalty finite element methods for high Reynolds number flows

Velocity-pressure integrated and consistent penalty finite element computations of high Reynolds number laminar flows are presented. In both methods the pressure has been interpolated using linear shape functions for a triangular element which is contained inside the biquadratic flow element. It has been shown previously that the pressure interpolation method, when used in conjunction with the velocity-pressure integrated method, yields accurate computational results for high-Reynolds-number flows. It is shown in this paper that use of the same pressure interpolation method in the consistent penalty finite element method yields computational results which are comparable to those of the velocity-pressure integrated method for both the velocity and the pressure fields. Accuracy of the two finite element methods has been demonstrated by comparing the computational results with available experimental data and/or fine grid finite difference computational results. Advantages and disadvantages of the two finite element methods are discussed on the basis of accuracy and convergence nature. Example problems considered include a lid-driven cavity flow of Reynolds number 10000, a laminar backward-facing step flow and a laminar flow through a nest of cylinders.

Kim, S.-W.↗

A least-squares finite element method for incompressible Navier-Stokes problems

A least-squares finite element method, based on the velocity-pressure-vorticity formulation, is developed for solving steady incompressible Navier-Stokes problems. This method leads to a minimization problem rather than to a saddle-point problem by the classic mixed method, and can thus accommodate equal-order interpolations. This method has no parameter to tune. The associated algebraic system is symmetric, and positive definite. Numerical results for the cavity flow at Reynolds number up to 10,000 and the backward-facing step flow at Reynolds number up to 900 are presented.

Jiang, Bo-Nan↗

A least-squares finite element method for incompressible Navier-Stokes problems

A least-squares finite element method, based on the velocity-pressure-vorticity formulation, is developed for solving steady incompressible Navier-Stokes problems. This method leads to a minimization problem rather than to a saddle-point problem by the classic mixed method and can thus accommodate equal-order interpolations. This method has no parameter to tune. The associated algebraic system is symmetric, and positive definite. Numerical results for the cavity flow at Reynolds number up to 10,000 and the backward-facing step flow at Reynolds number up to 900 are presented.

Jiang, Bo-Nan↗

Radiation and scattering from printed antennas on cylindrically conformal platforms

The goal was to develop suitable methods and software for the analysis of antennas on cylindrical coated and uncoated platforms. Specifically, the finite element boundary integral and finite element ABC methods were employed successfully and associated software were developed for the analysis and design of wraparound and discrete cavity-backed arrays situated on cylindrical platforms. This work led to the successful implementation of analysis software for such antennas. Developments which played a role in this respect are the efficient implementation of the 3D Green's function for a metallic cylinder, the incorporation of the fast Fourier transform in computing the matrix-vector products executed in the solver of the finite element-boundary integral system, and the development of a new absorbing boundary condition for terminating the finite element mesh on cylindrical surfaces.

Kempel, Leo C.↗

Modeling and Characterization of Cavity Backed Circular Aperture Antenna With Suspended Stripline Probe Feed

The paper presents the numerically simulated input impedance of a cavity backed circular aperture antenna with suspended substrate stripline probe feed. The simulation is based on the finite element method. The results show the input impedance or the return loss as a function of the frequency with the probe dimensions as parameters. The simulated results are validated by measurements at millimeter-wave frequencies.