Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Multiple speed expandable bit synchronizer

A multiple speed bit synchronizer was designed for installation in an inertial navigation system data decoder to extract non-return-to-zero level data and clock signal from biphase level data. The circuit automatically senses one of four pre-determined biphase data rates and synchronizes the proper clock rate to the data. Through a simple expansion of the basic design, synchronization of more than four binarily related data rates can be accomplished. The design provides an easily adaptable, low cost, low power alternative to external bit synchronizers with additional savings in size and weight.

Bundinger, J. M.↗

Critique of a Hughes shuttle Ku-band data sampler/bit synchronizer

An alternative bit synchronizer proposed for shuttle was analyzed in a noise-free environment by considering the basic operation of the loop via timing diagrams and by linearizing the bit synchronizer as an equivalent, continuous, phased-lock loop (PLL). The loop is composed of a high-frequency phase-frequency detector which is capable of detecting both phase and frequency errors and is used to track the clock, and a bit transition detector which attempts to track the transitions of the data bits. It was determined that the basic approach was a good design which, with proper implementation of the accumulator, up/down counter and logic should provide accurate mid-bit sampling with symmetric bits. However, when bit asymmetry occurs, the bit synchronizer can lock up with a large timing error, yet be quasi-stable (timing will not change unless the clock and bit sequence drift). This will result in incorrectly detecting some bits.

Holmes, J. K.↗

Shuttle orbiter Ku-band radar/communications system design evaluation. Ku band bent-pipe channel performance evaluation

Because of difficulties with the bit detector of the SPA mode 1 channel 3 input port, a new bit synchronizer was required. The two prime candidate designs are described and analyzed. The selected design is a modification of one which utilizes a phase frequency detector to track the received data clock frequency and a mid-bit transition point sample detector to generate a bit timing error (phase error) signal to control the relative phase between the local clock and the local data stream. The model used to calculate the effects of cable attenuation and rise time degradation is discussed.

Holmes, J. K.↗

Precise time and Time Interval (PTTI) measurements from the navigation technology satellites and the GPS NAVSTAR-4 satellite

A time domain estimate for the NAVSTAR-4 SV clock offset was obtained for each SV pass over the GPS monitor sites, using a smoothed reference ephemeris, with corrections for ionospheric delay, tropospheric delay, earth rotation and relativistic effects. Conversion from the time domain to the frequency domain was made using the two sample Allan Variance; sigma-tau plots used to identify the noise processes. Estimates of flicker and white frequency noise for the NAVSTAR-4 rubidium frequency standard were obtained. The contribution of the reference ground clocks and other error sources to the frequency stability estimates were also considered.

Buisson, J. A.↗

Geodetic positioning using a global positioning system of satellites

Geodetic positioning using range, integrated Doppler, and interferometric observations from a constellation of twenty-four Global Positioning System satellites is analyzed. A summary of the proposals for geodetic positioning and baseline determination is given which includes a description of measurement techniques and comments on rank deficiency and error sources. An analysis of variance comparison of range, Doppler, and interferometric time delay to determine their relative geometric strength for baseline determination is included. An analytic examination to the effect of a priori constraints on positioning using simultaneous observations from two stations is presented. Dynamic point positioning and baseline determination using range and Doppler is examined in detail. Models for the error sources influencing dynamic positioning are developed. Included is a discussion of atomic clock stability, and range and Doppler observation error statistics based on random correlated atomic clock error are derived.

Fell, P. J.↗

Digital numerically controlled oscillator

The frequency and phase of an output signal from an oscillator circuit are controlled with accuracy by a digital input word. Positive and negative alterations in output frequency are both provided for by translating all values of input words so that they are positive. The oscillator reference frequency is corrected only in one direction, by adding phase to the output frequency of the oscillator. The input control word is translated to a single algebraic sign and the digital 1 is added thereto. The translated input control word is then accumulated. A reference clock signal having a frequency at an integer multiple of the desired frequency of the output signal is generated. The accumulated control word is then compared with a threshold level. The output signal is adjusted in a single direction by dividing the frequency of the reference clock signal by a first integer or by an integer different from the first integer.

Cellier, A.↗

Innovation and reliability of atomic standards for PTTI applications

Innovation and reliability in hyperfine frequency standards and clock systems are discussed. Hyperfine standards are defined as those precision frequency sources and clocks which use a hyperfine atomic transition for frequency control and which have realized significant commercial production and acceptance (cesium, hydrogen, and rubidium atoms). References to other systems such as thallium and ammonia are excluded since these atomic standards have not been commercially exploited in this country.

Kern, R.↗

PTTI applications at Hydro-Quebec

As a power utility, Hydro-Quebec used the PTTI techniques. The time dissemination system in the Hydro-Quebec Network (11th PTTI) is now installed in several points. A portable clock was built using a rubidium standard and associated circuitry which are necessary for the measurements. The apparatus and the experimental results obtained are described. The use of GOES synchronized clocks for making precise voltage angle measurement on the Hydro-Quebec Network is discussed. Some modifications were made on a commercial unit. Applications and results are presented.

Missout, G.↗

The operational performance of hydrogen masers in the deep space network: The performance of laboratory reference frequency standards in an operational environment

Hydrogen masers used as aids in meeting the routine frequency and time operational requirements within the 64 m antenna Deep Space Network. Both the operational syntonation (frequency synchronization) and the the clock (epoch) synchronization requirements were established through the use of specifically calibrated H-P E215061A flying clock. The sync/synt to UTC was maintained using LORAN and TV in simultaneous reception mode. The sync/synt within the 64 m net was maintained through the use of very long base interferometry. Results indicate that the hydrogen masers perform well within the required specifications.

Ward, S. C.↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗

Transport Control for High-Density Digital Recorder

Tape capstan drive motor speed controlled by phase-locked loop to keep data rate off of tape compatible with demand clock rate preventing deskewbuffer overflow or underflow. Immunity to speed perturbations caused by data dropouts is obtained by switching to different data-channel reference signal whenever dropout is detected by frame synchronizer in channel currently in use. Desired tape speed is selected by changing frequency of demand rate clock and changing divisor N in programable divider.

Matlin, M. D.↗

Risetime distortion of Shuttle Ku-band payload 50 MBPS data due to coaxial cable skin effects

This paper discusses distortion of digital signals generated in the Space Shuttle Ku-band communications systems. Specifically, the degradation considered is due to coaxial cables which interface data and clock from a source located in the payload bay to the KuSPA (Ku-Band Signal Processor Assembly) located in the avionics bay of the Shuttle. Due to the length (nearly 100 feet) and relatively narrow bandwidth of the cable, the clock and data waveforms are significantly affected by this transmission medium. This paper presents a closed form model that closely approximates the distortion of the waveforms measured in laboratory tests.

Schadelbauer, S.↗

Open-loop nanosecond-synchronization for wideband satellite communications

A synchronization technique for use with an onboard processing satellite communication system is discussed. The satellite oscillator is used both as the system time reference and as the frequency source for all downlink carriers and data clocks. Downlink timing is established at each system earth terminal through a combination of carrier and data-clock tracking and a downlink timing epoch signal consisting of one bit per TDMA data burst. Uplink timing is established by an open-loop range prediction process using precision ephemerides calculated and distributed by the central control station. Overall timing accuracy of the uplink signal at the satellite receiver of + or - 7 nanoseconds permits unambiguous identification of each data bit position in a 128 Mbps TDMA burst. This is accomplished by means of simple, inexpensive terminal hardware using available crystal oscillators for time/frequency references and digital synthesis techniques that may be implemented in digital LSI chips.

Holmes, W. M., Jr.↗

NRZ Data Asymmetry Corrector and Convolutional Encoder

Circuit compensates for timing, amplitude and symmetry perturbations. Data asymmetry corrector and convolutional encoder regenerate data and clock signals in spite of signal variations such as data or clock asymmetry, phase errors, and amplitude variations, then encode data for transmission.

Pfiffner, H. J.↗

Flip-Flop Digital Modulator

Clock switched on and off in response to data signal. Flip-flop modulator generates square-wave carrier frequency that is half clock frequency and turns carrier on and off. Final demodulator output logical inverse of data input.

Eno, R. F.↗

Design of the stift time and frequency transfer microwave ground terminal

The Satellite Time and Frequency Transfer System is intended to provide, simultaneously, global time comparisons at the subnanosecond level and frequency comparisons to better than 1 part in 10 to the 14th power. It utilizes an orbiting hydrogen maser clock and frequency standard that communicates, via microwave links, time and frequency information to Earth terminals operated by hydrogen masers controlling local clocks. A two-way microwave link, to and from the space vehicle provides Doppler information used to cancel the Doppler shifts in a one-way link from the spaceborne oscillator. Pseudo-random noise (PRN) modulation in the two-way link also provides range information to cancel the range delay in the PRN time transfer between space and Earth. The pseudo-random noise modulation system for time difference measurement and its incorporation in the Doppler cancellation system for frequency comparison is explained. The particular PRN code sequence selected and an analysis of the system is discussed.

Penfield, H.↗

A compact hydrogen maser with exceptional long-term stability

A passive hydrogen maser employing a smaller microwave cavity than previous masers is described. The volume of the entire resonator package, including a conventional source, hexapole state selector, and four magnetic shields, is estimated at 20 liters. The techniques for constructing the ceramic cavity, coating it with FEP, and attaching the endcaps to achieve a stable container (to allow its use as a single vacuum system) are described in detail. Frequency stability measurements were made of four such masers, against an NBS-4 cesium primary standard, against each other, and against eight commercial cesium clocks; frequency stability level is reported as 1.7 x 10 to the -12th tau exp -1/2 from 1 to 100,000 sec, and no drift above 1 x 10 to the -15th/day was found. Pressure and temperature effects on frequency stability were found at the 1 x 10 to the -14th level. Noise behavior beyond 200,000 sec is characterized as random walk. The potential use of a compact stable maser as a clock is suggested.

Howe, D. A.↗

First Results of GPS Time Transfer to Australia

A global positioning system (GPS) time transfer unit was installed at Tidbinbilla Deep Space Communications Complex of the DSN in June 1983. It was used to estimate the relationship to UTC(USNO MC) of the Tidbinbilla frequency and time system TID(FTS) based on a hydrogen maser, and to estimate the performance of the Australian free-running time scale UTC(AUS). Data from the first 3 months were analyzed three ways: by two-hop common view using JPL as intermediary; by long-arc interpolation of measurements against space vehicle clocks; and by long arc interpolation of GPS-Time results. Residuals from a single quadratic fit through 3 months of UTC(USNO MC) -TID(FTS) results were white noise with standard error 15 ns, and a flying clock measurement gave 70 ns agreement. A straight line fit through results UTC(USNO MC) - UTC(AUS) gave 90 ns standard error and 120 ns agreement. It is proposed to use the GPS measurements to steer UTC(AUS) to UTC(BIH), and to rename the existing time scale TA(AUS).

Mck.luck, J.↗