Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Verification and Validation of the New MCNP6.3 Criticality Features [Slides]

This presentation touches on a separate MCNP6.3 V&V document reports on all the default calculations for all test suites. Here, we look at new optional features of the MCNP6.3 code with Fission-matrix-based options, Convergence and population testing, and Automated acceleration of the fission source additionally Doppler Broadening Resonance Correction. Also touched on are validation benchmarks: criticality, crit_expanded, and Rossi-α. All the new MCNP6.3 options give statistically equivalent results and either provide a reduction or no change in computational cost. We consider giving these new features a try and using them for all criticality calculations.

97 MATHEMATICS AND COMPUTING↗

Alternative Source Verification for the NB5 Beamline

This report details the calculation and comparison of secondary neutron sources for the purpose of performing NB5 velocity selector shielding calculations without relying on the primary HB4 source and the use of a modified MCNP code to run the full model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resilience Through Data-Driven, Intelligent Designed Control: A Formal Methods Approach

The PNNL and GTRI team developed a strategy to integrate temporal logic rule specification for detection of cyber-intrusion in the source code and control algorithms of CPS using advanced cyber-data. The GTRI team utilized its capabilities in rule synthesis and temporal logic specifications for software assurance and verification to detect and predict impact of cyber-intrusions and malware in the computational and control algorithms of cyber-physical systems. The team also developed a testing and verification approach that could be used to validate the suggested approach against a realistic use-case CPS showcasing improvements in system impact prediction performance. Temporal logic offers a compact expression of events in absolute and relative time and has a formalized translation to state machines. As such, temporal logic rules can feasibly be synthesized to any system as a rule engine, with the process being formally verified to be correct. The goal here is to utilize temporal logic rules to detect cyber-attacks and manipulations in the computational algorithms and provide real-time software assurance and verification guarantees.

97 MATHEMATICS AND COMPUTING↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗

Setup and verification of a SCALE/KENO platform for generic FHR benchmark calculations

The work presented in this article is preliminary to downstream analysis of a generic fluoride salt-cooled high-temperature reactor (gFHR) core performed by the University of Tennessee in collaboration with Kairos Power (KP). A Monte Carlo transport model of the publicly available gFHR equilibrium core is developed in SCALE/KENO with multigroup energy treatment. Several output quantities of interest are used to verify the simulations against a benchmark model developed by KP using the continuous energy Monte Carlo code Serpent 2. Good agreement is seen in flux and fission rate profiles with a maximum relative difference of 1.4% and 2.8% respectively. Furthermore, an effective multiplication factor bias of 44 pcm was observed between the two simulations. The fuel temperature reactivity coefficient calculated with SCALE is within uncertainty to the reference model. This verification acts as a publicly reproducible benchmark for the gFHR in SCALE/KENO. A simplified depletion model is also presented where a single fuel pebble is depleted to discharge burnup through the equilibrium core while the equilibrium core is assumed to be invariant. This method produces results that intercept the equilibrium core concentrations in every case, however, an interesting artifact of this particular depletion model is uncovered. The phenomenon is shown to be a fundamental feature of the differential rate equations and inspires questions about how this system behaves when the time evolution of the equilibrium core is considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Paving the Way for Net Zero Energy Codes through Performance Based Approaches

The prescriptive path is the most widely used approach for commercial code compliance in the United States. However, to achieve near-term net zero energy performance that many stakeholders in the buildings industry desire, it is clear that energy codes will need to transition from prescriptive to performance-based approaches. However, that transition is not without potential pitfalls. Among the concerns expressed by stakeholders are added complexity and cost, lack of confidence in energy modeling results, gamesmanship on the part of applicants, lack or qualified reviewers, challenges in promoting de-carbonization, and the inequity of trading long lived envelope efficiency for short lived measures such as building controls. This paper will discuss multiple approaches being evaluated and implemented by Pacific Northwest National Laboratory to improve the usability of the performance-based approach for both code compliance and beyond code programs to meet aggressive energy savings targets. A 'system performance' approach provides a simpler approach compared to whole building performance, while keeping tradeoffs limited to specific building systems. A simplified whole-building performance-based approach for small commercial buildings can cost effectively achieve deeper savings for buildings that typically follow the prescriptive compliance approach. Improved reporting and verification processes applied to the traditional performance path can provide greater confidence in simulation results and facilitate adoption of performance-based approaches. Prescriptive packages provide prescriptive solutions while targeting specific performance thresholds. This paper discusses the progress being made with each of these approaches and provides examples of their implementation in energy codes and beyond code programs.

Performance Based Codes, Appendix G, PRM, TSPR, Sy↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Photometric redshift analysis in the Dark Energy Survey Science Verification data

In this study, we present results from a study of the photometric redshift performance of the Dark Energy Survey (DES), using the early data from a Science Verification period of observations in late 2012 and early 2013 that provided science-quality images for almost 200 sq. deg. at the nominal depth of the survey. We assess the photometric redshift (photo-z) performance using about 15 000 galaxies with spectroscopic redshifts available from other surveys. These galaxies are used, in different configurations, as a calibration sample, and photo-z's are obtained and studied using most of the existing photo-z codes. A weighting method in a multidimensional colour–magnitude space is applied to the spectroscopic sample in order to evaluate the photo-z performance with sets that mimic the full DES photometric sample, which is on average significantly deeper than the calibration sample due to the limited depth of spectroscopic surveys. In addition, empirical photo-z methods using, for instance, artificial neural networks or random forests, yield the best performance in the tests, achieving core photo-z resolutions σ68 ~ 0.08. Moreover, the results from most of the codes, including template-fitting methods, comfortably meet the DES requirements on photo-z performance, therefore, providing an excellent precedent for future DES data sets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-49: A Multi-Institutional Study of Independent Dose Verification for IMRT

Purpose: AAPM TG114 does not cover the independent verification for IMRT. We conducted a study of independent dose verification for IMRT in seven institutes to show the feasibility. Methods: 384 IMRT plans in the sites of prostate and head and neck (HN) were collected from the institutes, where the planning was performed using Eclipse and Pinnacle3 with the two techniques of step and shoot (S&S) and sliding window (SW). All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. An ion-chamber measurement in a water-equivalent slab phantom was performed to compare the doses computed using the TPS and an independent dose verification program. Additionally, the agreement in dose computed in patient CT images between using the TPS and using the SMU was assessed. The dose of the composite beams in the plan was evaluated. Results: The agreement between the measurement and the SMU were −2.3±1.9 % and −5.6±3.6 % for prostate and HN sites, respectively. The agreement between the TPSs and the SMU were −2.1±1.9 % and −3.0±3.7 for prostate and HN sites, respectively. There was a negative systematic difference with similar standard deviation and the difference was larger in the HN site. The S&S technique showed a statistically significant difference between the SW. Because the Clarkson-based method in the independent program underestimated (cannot consider) the dose under the MLC. Conclusion: The accuracy would be improved when the Clarkson-based algorithm should be modified for IMRT and the tolerance level would be within 5%.

60 APPLIED LIFE SCIENCES↗

MOCUM Verification with a Heterogeneous MOX Whole Core C5G7 Benchmark Problem

Recent advancements in computer technology has allowed for the possibility to solve complex reactor problems without homogenization, but the present benchmark problems are all limited to small scale with few fuel assemblies and homogeneity at the core level. Therefore, to verify the capabilities of the advanced neutronics codes, heterogeneous full core model shall be developed. Recently several whole-core benchmark problems such as BEAVRS and VERA are developed with measured data to which computational codes can be compared. With a particular research interest on the MOX fuel, this study develops a two-dimensional (2-D) whole core MOX neutronics benchmark based on the C5G7 benchmark concept. The developed MOX core benchmark will then be used to verify the accuracy of the MOCUM code, which is developed using the method of characteristic (MOC) as the flux solver with an advanced geometry processor designed for arbitrary core geometries. MOCUM results will be compared against MCNP5 results as the reference solutions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Economic Model for Estimation of GDP Losses in the MACCS Offsite Consequence Analysis Code

The MACCS (MELCOR Accident Consequence Code System) code is the U.S. Nuclear Regulatory Commission (NRC) tool used to perform probabilistic health and economic consequence assessments for atmospheric releases of radionuclides. It is also used by international organizations, both reactor owners and regulators. It is intended and most commonly used for hypothetical accidents that could potentially occur in the future rather than to evaluate past accidents or to provide emergency response during an ongoing accident. It is designed to support probabilistic risk and consequence analyses and is used by the NRC, U.S. nuclear licensees, the Department of Energy, and international vendors, licensees, and regulators. This report describes the modeling framework, implementation, verification, and benchmarking of a GDP-based model for economic losses that has recently been developed as an alternative to the original cost-based economic loss model in MACCS. The GDP-based model has its roots in a code developed by Sandia National Laboratories for the Department of Homeland Security to estimate short-term losses from natural and manmade accidents, called the Regional Economic Accounting analysis tool (REAcct). This model was adapted and modified for MACCS and is now called the Regional Disruption Economic Impact Model (RDEIM). It is based on input-output theory, which is widely used in economic modeling. It accounts for direct losses to a disrupted region affected by an accident, indirect losses to the national economy due to disruption of the supply chain, and induced losses from reduced spending by displaced workers. RDEIM differs from REAcct in its treatment and estimation of indirect loss multipliers, elimination of double counting associated with inter-industry trade in the affected area, and that it is designed to be used to estimate impacts for extended periods that can occur from a major nuclear reactor accident, such as the one that occurred at the Fukushima Daiichi site in Japan. Most input-output models do not account for economic adaptation and recovery, and in this regard RDEIM differs from its parent, REAcct, because it allows for a user-definable national recovery period. Implementation of a recovery period was one of several recommendations made by an independent peer review panel to ensure that RDEIM is state-of-practice. For this and several other reasons, RDEIM differs from REAcct. Both the original and the RDEIM economic loss models account for costs from evacuation and relocation, decontamination, depreciation, and condemnation. Where the original model accounts for an expected rate of return, based on the value of property, that is lost during interdiction, the RDEIM model instead accounts for losses of GDP based on the industrial sectors located within a county. The original model includes costs for disposal of crops and milk that the RDEIM model currently does not, but these costs tend to contribute insignificantly to the overall losses. This document discusses three verification exercises to demonstrate that the RDEIM model is implemented correctly in MACCS. It also describes a benchmark study at five nuclear power plants chosen to represent the spectrum of U.S. commercial sites. The benchmarks provide perspective on the expected differences between the RDEIM and the original cost-based economic loss models. The RDEIM model is shown to consistently predict larger losses than the original model, probably in part because it accounts for national losses by including indirect and induced losses; whereas, the original model only accounts for regional losses. Nonetheless, the RDEIM model predicts losses that are remarkably consistent with the original cost-based model, differing by 16% at most for the five sites combined with three source terms considered in this benchmark.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MCNP6™ Release 1.0: Creating and Testing the Code Distribution

This report documents the preparations for and testing of the production release of MCNP6™ through RSICC at ORNL. It addresses tests on supported operating systems (Linux, MacOSX, Windows) with the supported compilers (Intel, Portland Group International, PathsScale and gfortran). Verification and Validation test results are documented elsewhere. This report does not address in detail the overall packaging of the distribution. Specifically, it does not address the nuclear and atomic data collection, the other included software packages (MCNP5 and MCNPX) and the collection of reference documents.

07 ISOTOPE AND RADIATION SOURCES↗

MCNP(TM) Release 6.1.1 beta: Creating and Testing the Code Distribution

This report documents the preparations for and testing of the production release of MCNP6™1.1 beta through RSICC at ORNL. It addresses tests on supported operating systems (Linux, MacOSX, Windows) with the supported compilers (Intel, Portland Group and gfortran). Verification and Validation test results are documented elsewhere. This report does not address in detail the overall packaging of the distribution. Specifically, it does not address the nuclear and atomic data collection, the other included software packages (MCNP5, MCNPX and MCNP6) and the collection of reference documents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of ORIGEN for VVER-440 Spent Fuel with Application to Fork Detector Safeguards Measurements

The US Department of Energy National Nuclear Security Administration and the European Atomic Energy Community (Euratom) are collaborating with the Radiation and Nuclear Safety Authority in Finland to assess spent fuel verification methods for potential application to measurements at the planned spent fuel encapsulation plant and geological repository prior to final disposal in Finland. The fork detector (FDET) used to measure the neutron and gamma radiation from a given spent fuel assembly is an existing technology widely used by the International Atomic Energy Agency (IAEA) and Euratom for the safeguards verification of spent fuel operator declaration. Recently, an FDET data analysis software, referred to as the ORIGEN module, was developed and incorporated into the IAEA/Euratom Integrated Review and Analysis Program. This module uses the ORIGEN burnup code to calculate the nuclide concentrations and the neutron and gamma source terms in the spent fuel based on operator declarations. Then, to predict the expected FDET signals for a given fuel assembly, the module combines the source terms calculated by ORIGEN with FDET response functions that were pre-generated using MCNP models. The inspector can compare the calculated signals to the measured values in real time to identify possible anomalies in fuel assembly’s operator declaration, integrity, or measurement. In this work, the capability of the ORIGEN module was extended from application to typical light water reactor fuels to use for VVER-440 assembly types. The accuracy of ORIGEN for this type of fuel assembly calculations was assessed by comparing calculated nuclide concentrations against destructive assay measurements for VVER-440 spent fuel. The performance of the ORIGEN module for FDET safeguards verification in routine inspections was assessed using FDET measurement data for 13 spent VVER-440 assemblies that were measured at the Loviisa Nuclear Power Plant in Finland, by comparing the calculated signals to the measured quantities. The results show that the calculated FDET neutron and gamma detector signals are generally within 12% of the measurements except for one assembly. Thus, these results are applicable to future safeguards verification in the planned Finland encapsulation plant, such as for passive neutron albedo reactivity safeguards measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-E-T-36: A GPU-Accelerated Monte-Carlo Dose Calculation Platform and Its Application Toward Validating a ViewRay Beam Model

Purpose: To build a fast, accurate and easily-deployable research platform for Monte-Carlo dose calculations. We port the dose calculation engine PENELOPE to C++, and accelerate calculations using GPU acceleration. Simulations of a Co-60 beam model provided by ViewRay demonstrate the capabilities of the platform. Methods: We built software that incorporates a beam model interface, CT-phantom model, GPU-accelerated PENELOPE engine, and GUI front-end. We rewrote the PENELOPE kernel in C++ (from Fortran) and accelerated the code on a GPU. We seamlessly integrated a Co-60 beam model (obtained from ViewRay) into our platform. Simulations of various field sizes and SSDs using a homogeneous water phantom generated PDDs, dose profiles, and output factors that were compared to experiment data. Results: With GPU acceleration using a dated graphics card (Nvidia Tesla C2050), a highly accurate simulation – including 100*100*100 grid, 3×3×3 mm3 voxels, <1% uncertainty, and 4.2×4.2 cm2 field size – runs 24 times faster (20 minutes versus 8 hours) than when parallelizing on 8 threads across a new CPU (Intel i7-4770). Simulated PDDs, profiles and output ratios for the commercial system agree well with experiment data measured using radiographic film or ionization chamber. Based on our analysis, this beam model is precise enough for general applications. Conclusions: Using a beam model for a Co-60 system provided by ViewRay, we evaluate a dose calculation platform that we developed. Comparison to measurements demonstrates the promise of our software for use as a research platform for dose calculations, with applications including quality assurance and treatment plan verification.

60 APPLIED LIFE SCIENCES↗

Cable SGEMP Code Validation Study

This report compared data taken on the Modular Bremsstrahlung Simulator using copper jacketed (cujac) cables with calculations using the RHSD-RA Cable SGEMP analysis tool. The tool relies on CEPXS/ONBFP to perform radiation transport in a series of 1D slices through the cable, and then uses a Green function technique to evaluate the expected current drive on the center conductor. The data were obtained in 2003 as part of a Cabana verification and validation experiment using 1-D geometries, but were not evaluated until now. The agreement between data and model is not adequate unless gaps between the dielectric and outer conductor (ground) are assumed, and these gaps are large compared with what is believed to be in the actual cable.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Generative diffusion model surrogates for mechanistic agent-based biological models

Mechanistic, multicellular, agent-based models are commonly used to investigate tissue, organ, and organism-scale biology at single-cell resolution. The Cellular-Potts Model (CPM) is a powerful and popular framework for developing and interrogating these models. CPMs become computationally expensive at large space- and time- scales making application and investigation of developed models difficult. Surrogate models may allow for the accelerated evaluation of CPMs of complex biological systems. However, the stochastic nature of these models means each set of parameters may give rise to different model configurations, complicating surrogate model development. In this work, we leverage denoising diffusion probabilistic models (DDPMs) to train a generative AI surrogate of a CPM used to investigate in vitro vasculogenesis. We describe the use of an image classifier to learn the characteristics that define unique areas of a 2-dimensional parameter space. We then apply this classifier to aid in surrogate model selection and verification. Our CPM model surrogate generates model configurations 20,000 timesteps ahead of a reference configuration and demonstrates approximately a 22x reduction in computational time as compared to native code execution. Our work represents a step towards the implementation of DDPMs to develop digital twins of stochastic biological systems.

97 MATHEMATICS AND COMPUTING↗

SU-G-IeP2-04: Dosimetric Accuracy of a Monte Carlo-Based Tool for Cone-Beam CT Organ Dose Calculation: Validation Against OSL and XRQA2 Film Measurements

Purpose: The intensive use of Cone-Beam Computed Tomography (CBCT) during radiotherapy treatments raise some questions about the dose to healthy tissues delivered during image acquisitions. We hence developed a Monte Carlo (MC)-based tool to predict doses to organs delivered by the Elekta XVI kV-CBCT. This work aims at assessing the dosimetric accuracy of the MC tool, in all tissue types. Methods: The kV-CBCT MC model was developed using the PENELOPE code. The beam properties were validated against measured lateral and depth dose profiles in water, and energy spectra measured with a CdTe detector. The CBCT simulator accuracy then required verification in clinical conditions. For this, we compared calculated and experimental dose values obtained with OSL nanoDots and XRQA2 films inserted in CIRS anthropomorphic phantoms (male, female, and 5-year old child). Measurements were performed at different locations, including bone and lung structures, and for several acquisition protocols: lung, head-and-neck, and pelvis. OSLs and film measurements were corrected when possible for energy dependence, by taking into account for spectral variations between calibration and measurement conditions. Results: Comparisons between measured and MC dose values are summarized in table 1. A mean difference of 8.6% was achieved for OSLs when the energy correction was applied, and 89.3% of the 84 dose points were within uncertainty intervals, including those in bones and lungs. Results with XRQA2 are not as good, because incomplete information about electronic equilibrium in film layers hampered the application of a simple energy correction procedure. Furthermore, measured and calculated doses (Fig.1) are in agreement with the literature. Conclusion: The MC-based tool developed was validated with an extensive set of measurements, and enables the organ dose calculation with accuracy. It can now be used to compute and report doses to organs for clinical cases, and also to drive strategies to optimize imaging protocols.

60 APPLIED LIFE SCIENCES↗