Search NASA⌕ Search

SEARCH · Search NASA

Results for “control methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Method for the control of NOx emissions in long-range space travel

The wheat straw, an inedible biomass that can be continuously produced in a space vehicle has been used to produce activated carbon for effective control of NOx emissions from the incineration of wastes. The optimal carbonization temperature of wheat straw was found to be around 600 degrees C when a burnoff of 67% was observed. The BET surface area of the activated carbon produced from the wheat straw reached as high as 300 m2/g. The presence of oxygen in flue gas is essential for effective adsorption of NO by activated carbon. On the contrary, water vapor inhibits the adsorption efficiency of NO. Consequently, water vapor in flue gas should be removed by drying agents before adsorption to ensure high NO adsorption efficiency. All of the NO in the flue gas was removed for more than 2 h by the activated carbons when 10% oxygen was present and the ratio of carbon weight to the flue gas flow rate (W/F) was 30 g min/L, with a contact time of 10.2 s. All of NO was reduced to N2 by the activated carbon at 450 degrees C with a W/F ratio of 15 g min/L and a contact time of 5.1 s. Reduction of the adsorbed NO also regenerated the activated carbon, and the regenerated activated carbon exhibited an improved NO adsorption efficiency. However, the reduction of the adsorbed NO resulted in a loss of carbon which was determined to be about 0.99% of the activated carbon per cycle of regeneration. The sufficiency of the amount of wheat straw in providing the activated carbon based on a six-person crew, such as the mission planned for Mars, has been determined. This novel approach for the control of NOx emissions is sustainable in a closed system such as the case in space travel. It is simple to operate and is functional under microgravity environment.

NASA Discipline Life Support Systems↗

Progress Towards Computational Method for Circulation Control Airfoils

The compressible Reynolds-averaged Navier-Stokes equations are solved for circulation control airfoil flows. Numerical solutions are computed with both structured and unstructured grid solvers. Several turbulence models are considered, including the Spalart-Allmaras model with and without curvature corrections, the shear stress transport model of Menter, and the k-enstrophy model. Circulation control flows with jet momentum coefficients of 0.03, 0.10, and 0.226 are considered. Comparisons are made between computed and experimental pressure distributions, velocity profiles, Reynolds stress profiles, and streamline patterns. Including curvature effects yields the closest agreement with the measured data.

Swanson, R. C.↗

Model-Based Self-Tuning Multiscale Method for Combustion Control

A multi-scale representation of the combustor dynamics was used to create a self-tuning, scalable controller to suppress multiple instability modes in a liquid-fueled aero engine-derived combustor operating at engine-like conditions. Its self-tuning features designed to handle the uncertainties in the combustor dynamics and time-delays are essential for control performance and robustness. The controller was implemented to modulate a high-frequency fuel valve with feedback from dynamic pressure sensors. This scalable algorithm suppressed pressure oscillations of different instability modes by as much as 90 percent without the peak-splitting effect. The self-tuning logic guided the adjustment of controller parameters and converged quickly toward phase-lock for optimal suppression of the instabilities. The forced-response characteristics of the control model compare well with those of the test rig on both the frequency-domain and the time-domain.

Le, Dzu, K.↗

Robust Gain-Scheduled Fault Tolerant Control for a Transport Aircraft

This paper presents an application of robust gain-scheduled control concepts using a linear parameter-varying (LPV) control synthesis method to design fault tolerant controllers for a civil transport aircraft. To apply the robust LPV control synthesis method, the nonlinear dynamics must be represented by an LPV model, which is developed using the function substitution method over the entire flight envelope. The developed LPV model associated with the aerodynamic coefficient uncertainties represents nonlinear dynamics including those outside the equilibrium manifold. Passive and active fault tolerant controllers (FTC) are designed for the longitudinal dynamics of the Boeing 747-100/200 aircraft in the presence of elevator failure. Both FTC laws are evaluated in the full nonlinear aircraft simulation in the presence of the elevator fault and the results are compared to show pros and cons of each control law.

Shin, Jong-Yeob↗

Gas turbine engine control system

A control system and method of controlling a gas turbine engine. The control system receives an error signal and processes the error signal to form a primary fuel control signal. The control system also receives at least one anticipatory demand signal and processes the signal to form an anticipatory fuel control signal. The control system adjusts the value of the anticipatory fuel control signal based on the value of the error signal to form an adjusted anticipatory signal and then the adjusted anticipatory fuel control signal and the primary fuel control signal are combined to form a fuel command signal.

Idelchik, Michael S.↗

Apparatus and methods for humidity control

Apparatus is provided which controls humidity in a gas. The apparatus employs a porous interface that is preferably a manifolded array of stainless steel tubes through whose porous surface water vapor can pass. One side of the porous interface is in contact with water and the opposing side is in contact with gas whose humidity is being controlled. Water vapor is emitted from the porous surface of the tubing into the gas when the gas is being humidified, and water vapor is removed from the gas through the porous surfaces when the gas is being dehumidified. The temperature of the porous interface relative to the gas temperature determines whether humidification or dehumidification is being carried out. The humidity in the gas is sensed and compared to the set point humidity. The water temperature, and consequently the porous interface temperature, are automatically controlled in response to changes in the gas humidity level above or below the set point. Any deviation from the set point humidity is thus corrected.

Dinauer, William R.↗

Multibeam optical apparatus and method for tracking control for an optical disk having a set of tracks

A multitrack optical disk has two or more circular or spiral tracks, which are recorded or played back in simultaneous sets for high data rates. Tracking is accomplished by sets of first and second tracking pads, which lie partially on and partially off the track paths. The amount of inter-track space required to accommodate the track pads is reduced by placing the overlap of the tracking pads in the same inter-track space, and by tracking any additional simultaneous tracks in excess of two by mechanical coupling with the first two.

Reno, Charles W.↗

Hybrid architecture active wavefront sensing and control system, and method

According to various embodiments, provided herein is an optical system and method that can be configured to perform image analysis. The optical system can comprise a telescope assembly and one or more hybrid instruments. The one or more hybrid instruments can be configured to receive image data from the telescope assembly and perform a fine guidance operation and a wavefront sensing operation, simultaneously, on the image data received from the telescope assembly.

Feinberg, Lee D.↗

Robust Operation of Tendon-Driven Robot Fingers Using Force and Position-Based Control Laws

A robotic system includes a tendon-driven finger and a control system. The system controls the finger via a force-based control law when a tension sensor is available, and via a position-based control law when a sensor is not available. Multiple tendons may each have a corresponding sensor. The system selectively injects a compliance value into the position-based control law when only some sensors are available. A control system includes a host machine and a non-transitory computer-readable medium having a control process, which is executed by the host machine to control the finger via the force- or position-based control law. A method for controlling the finger includes determining the availability of a tension sensor(s), and selectively controlling the finger, using the control system, via the force or position-based control law. The position control law allows the control system to resist disturbances while nominally maintaining the initial state of internal tendon tensions.

Abdallah, Muhammad E↗

Systems and Methods for Collaboratively Controlling at Least One Aircraft

An unmanned vehicle management system includes an unmanned aircraft system (UAS) control station controlling one or more unmanned vehicles (UV), a collaborative routing system, and a communication network connecting the UAS and the collaborative routing system. The collaborative routing system being configured to receive flight parameters from an operator of the UAS control station and, based on the received flight parameters, automatically present the UAS control station with flight plan options to enable the operator to operate the UV in a defined airspace.

Estkowski, Regina I.↗

Survey of Methods to Predict Controller Workload for Real-Time Monitoring of Airspace Safety

The Real Time Safety Monitoring (RTSM) approach allows for assessment and prediction of the safety margin in the National Airspace System (NAS) to help preempt incidents and accidents, rather than having to reactively mitigate them. In RTSM, the NAS is modeled using state variables, and safety metrics are defined in terms of these state variables. The safety metrics have been classified as weather-related, airspace-related, and human-related. Many of the formulated human-related safety metrics need an estimate of the controller workload for their computation. However, this computation is not trivial. Hence, in this report, we perform a literature survey to identify the different factors that enable the computation of controller workload and categorize these factors. Next, we describe studies undertaken to determine a minimal set of factors that pro- vide a correct assessment of controller workload. Lastly, we survey approaches for evaluating how well the selected factors correlate with the controllers' subjective assessment of their workload. Based on this survey, we present factors beneficial to computing and predicting controller workload in real time, and discuss the status of data sources necessary for these computations.

National Airspace System↗

Apparatus and method for deterministic control of surface figure during full aperture pad polishing

A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. The first and second radial directions may be opposite directions.

42 ENGINEERING↗

Load power device, system and method of load control and management employing load identification

A load power device includes a power input, at least one power output for at least one load, a plurality of sensors structured to sense voltage and current at the at least one power output, and a processor. The processor provides: (a) load identification based upon the sensed voltage and current, and (b) load control and management based upon the load identification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for quality control of a periodic structure

Quality control of a periodic structure is performed using the damping rate of acoustic waves generated in the periodic structure. In this technique, an excitation light beam illuminates the first layer in the periodic structure to excite an acoustic wave. Possible irregularities in the periodic structure can scatter the acoustic wave, thereby increasing the damping rate of the acoustic wave. A sequence of probe light beams illuminates the periodic structure to measure the acoustic wave as a function of time to generated a temporal signal representing the damping rate of the acoustic signal. The acquired damping rate is employed to evaluate the quality of the periodic structure.

Maznev, Alexei↗

Method for dynamic control of light emission from phosphors with heat excitations

An optically emissive material and, in particular, materials for use in single photon generation technologies, have multiple excited energy states that have different decay rates and can emit photons with different properties. A primary excitation radiation source is configured to apply primary radiation to an optically emissive material to excite the optically emissive material into a primary excited state. A secondary excitation radiation source is configured to apply secondary radiation to a thermal contribution material to generate thermal energy in the thermal contribution material. The thermal contribution material is physically configured to transfer thermal energy to the optically emissive material and excite the optically emissive material from the primary excited state to a secondary excited state for dynamic control of the emission rate, or emitted photon properties, of the optically emissive material.

36 MATERIALS SCIENCE↗

System and method for plasmonic control of short pulses in optical fibers

The present disclosure relates to an optical waveguide system. The system may include a first waveguide having a core-guide and a material portion surrounding and encasing the core-guide. The core-guide enables a core-guide mode for an optical signal travelling through the core-guide. A second waveguide forms a lossy waveguide on an outer surface of the first waveguide. The construction of the second waveguide is such as to achieve a desired coupling between the core-guide mode and the lossy waveguide to control an energy level of the optical signal travelling through the core-guide.

42 ENGINEERING↗