Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Chemical Signatures of and Precursors to Fractures Using Fluid Inclusion Stratigraphy

Enhanced Geothermal Systems (EGS) are designed to recover heat from the subsurface by mechanically creating fractures in subsurface rocks. Open or recently closed fractures would be more susceptible to enhancing the permeability of the system. Identifying dense fracture areas as well as large open fractures from small fracture systems will assist in fracture stimulation site selection. Geothermal systems are constantly generating fractures (Moore, Morrow et al. 1987), and fluids and gases passing through rocks in these systems leave small fluid and gas samples trapped in healed microfractures. These fluid inclusions are faithful records of pore fluid chemistry. Fluid inclusions trapped in minerals as the fractures heal are characteristic of the fluids that formed them, and this signature can be seen in fluid inclusion gas analysis. This report presents the results of the project to determine fracture locations by the chemical signatures from gas analysis of fluid inclusions. With this project we hope to test our assumptions that gas chemistry can distinguish if the fractures are open and bearing production fluids or represent prior active fractures and whether there are chemical signs of open fracture systems in the wall rock above the fracture. Fluid Inclusion Stratigraphy (FIS) is a method developed for the geothermal industry which applies the mass quantification of fluid inclusion gas data from drill cuttings and applying known gas ratios and compositions to determine depth profiles of fluid barriers in a modern geothermal system (Dilley, 2009; Dilley et al., 2005; Norman et al., 2005). Identifying key gas signatures associated with fractures for isolating geothermal fluid production is the latest advancement in the application of FIS to geothermal systems (Dilley and Norman, 2005; Dilley and Norman, 2007). Our hypothesis is that peaks in FIS data are related to location of fractures. Previous work (DOE Grant DE-FG36-06GO16057) has indicated differences in the chemical signature of fluid inclusions between open and closed fractures as well as differences in the chemical signature of open fractures between geothermal systems. Our hypothesis is that open fracture systems can be identified by their FIS chemical signature; that there are differences based on the mineral assemblages and geology of the system; and that there are chemical precursors in the wall rock above open, large fractures. Specific goals for this project are: (1) To build on the preliminary results which indicate that there are differences in the FIS signatures between open and closed fractures by identifying which chemical species indicate open fractures in both active geothermal systems and in hot, dry rock; (2) To evaluate the FIS signatures based on the geology of the fields; (3) To evaluate the FIS signatures based on the mineral assemblages in the fracture; and (4) To determine if there are specific chemical signatures in the wall rock above open, large fractures. This method promises to lower the cost of geothermal energy production in several ways. Knowledge of productive fractures in the boreholes will allow engineers to optimize well production. This information can aid in well testing decisions, well completion strategies, and in resource calculations. It will assist in determining the areas for future fracture enhancement. This will develop into one of the techniques in the 'tool bag' for creating and managing Enhanced Geothermal Systems.

15 GEOTHERMAL ENERGY↗

Accelerating Multivariate Functional Approximation Computation with Domain Decomposition Techniques⋆

Modeling large datasets through Multivariate Functional Approximations (MFA) provide an elegant way to handle many visualization and scientific analysis workflows. The process necessitates scalable data partitioning methods to compute MFA representations efficiently without compromising the accuracy or continuity of the reconstructed solution. We propose a domain -decomposed method for computing the MFA with B -spline bases, which reduces the total work per task and uses a restricted Additive Schwarz (RAS) method to converge the control point data degrees -of -freedom along subdomain boundaries. We provide an in-depth analysis of the parallel approach with domain decomposition solvers, aiming to minimize local subdomain error residuals and recover high -order continuity at subdomain interfaces with appropriate choices of knot overlaps. The communication cost, determined by the overlap regions in the RAS implementation, is optimized to recover the numerical error profile of the single subdomain case. Our proposed method stands in contrast to previous methods, which typically only recover either C 0 or at best C 1 continuity for arbitrary B -spline degree expansions, or those that require post -processing to blend discontinuities in the reconstructed data. We demonstrate the effectiveness of our approach using analytical and real -world datasets in 1D, 2D, and 3D through both strong and weak scaling studies. The performance results indicate that the overall cost of computing the approximation is directly proportional to the underlying nearest -neighbor communication implementation, and is only weakly dependent on the overlap region size that determines the size of the messages. This finding underscores the efficiency and scalability of our proposed method, making it a promising solution for handling large datasets in scientific workflows.

additive Schwarz solvers↗

AN ANALYTIC PARAMETERIZATION OF SELF-GRAVITY WAKES IN SATURN'S RINGS, WITH APPLICATION TO OCCULTATIONS AND PROPELLERS

We have developed a semianalytic method of parameterizing N-body simulations of self-gravity wakes in Saturn's rings, describing their photometric properties by means of only six numbers: three optical depths and three weighting factors. These numbers are obtained by fitting a sum of three Gaussians to the results of a density-estimation procedure that finds the frequencies of various values of local density within a simulated ring patch. Application of our parameterization to a suite of N-body simulations implies that rings dominated by self-gravity wakes appear to be mostly empty space, with more than half of their surface area taken up by local optical depths around 0.01. Such regions will be photometrically inactive for all viewing geometries. While this result might be affected by our use of identically sized particles, we believe the general result that the distribution of local optical depths is trimodal, rather than bimodal as previous authors have assumed, is robust. The implications of this result for the analysis of occultation data are more conceptual than practical, as we find that occultations can only distinguish between bimodal and trimodal models at very low opening angles. Thus, the only adjustment needed in existing analyses of occultation data is that the model parameter {tau}{sub gap} should be interpreted as representing the area-weighted average optical depth within the gaps (or inter-wake regions), keeping in mind the possibility that the optical depth within those inter-wake regions may vary significantly. The most significant consequence of our results applies to the question of why 'propeller' structures observed in the mid-A ring are seen as relative-bright features, even though the most prominent features of simulated propellers are regions of relatively low density. Our parameterization of self-gravity wakes lends preliminary quantitative support to the hypothesis that propellers would be bright if they involve a local and temporary disruption of self-gravity wakes. Even though the overall local density is lower within the propeller-shaped structure surrounding an embedded central moonlet, disruption of the wakes would flood these same regions with more 'photometrically active' material (i.e., material that can contribute to the rings' local optical depth), raising their apparent brightnesses in agreement with observations. We find for a wide range of input parameters that this mechanism indeed can plausibly make propellers brighter than the wake-dominated background, though it is also possible for propellers to blend in with the background or even to remain dark. We suggest that this mechanism be tested by future detailed numerical models.

79 ASTRONOMY AND ASTROPHYSICS↗

PylotDB - A Database Management, Graphing, and Analysis Tool Written in Python

PylotDB, written completely in Python, provides a user interface (UI) with which to interact with, analyze, graph data from, and manage open source databases such as MySQL. The UI mitigates the user having to know in-depth knowledge of the database application programming interface (API). PylotDB allows the user to generate various kinds of plots from user-selected data; generate statistical information on text as well as numerical fields; backup and restore databases; compare database tables across different databases as well as across different servers; extract information from any field to create new fields; generate, edit, and delete databases, tables, and fields; generate or read into a table CSV data; and similar operations. Since much of the database information is brought under control of the Python computer language, PylotDB is not intended for huge databases for which MySQL and Oracle, for example, are better suited. PylotDB is better suited for smaller databases that might be typically needed in a small research group situation. PylotDB can also be used as a learning tool for database applications in general.

Barnette, DanielW.↗

SEVEN-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE (WMAP ) OBSERVATIONS: POWER SPECTRA AND WMAP-DERIVED PARAMETERS

The WMAP mission has produced sky maps from seven years of observations at L2. We present the angular power spectra derived from the seven-year maps and discuss the cosmological conclusions that can be inferred from WMAP data alone. With the seven-year data, the temperature (TT) spectrum measurement has a signal-to-noise ratio per multipole that exceeds unity for l < 919; and in band powers of width {Delta}l = 10, the signal-to-noise ratio exceeds unity up to l = 1060. The third acoustic peak in the TT spectrum is now well measured by WMAP. In the context of a flat {Lambda}CDM model, this improvement allows us to place tighter constraints on the matter density from WMAP data alone, {Omega}{sub m} h {sup 2} = 0.1334{sup +0.0056}{sub -0.0055}, and on the epoch of matter-radiation equality, z{sub eq} = 3196{sup +134}{sub -133}. The temperature-polarization (TE) spectrum is detected in the seven-year data with a significance of 20{sigma}, compared to 13{sigma} with the five-year data. We now detect the second dip in the TE spectrum near l {approx} 450 with high confidence. The TB and EB spectra remain consistent with zero, thus demonstrating low systematic errors and foreground residuals in the data. The low-l EE spectrum, a measure of the optical depth due to reionization, is detected at 5.5{sigma} significance when averaged over l = 2-7: l(l + 1)C {sup EE}{sub l}/(2{pi}) = 0.074{sup +0.034}{sub -0.025} {mu}K{sup 2} (68% CL). We now detect the high-l, 24 {<=} l {<=} 800, EE spectrum at over 8{sigma}. The BB spectrum, an important probe of gravitational waves from inflation, remains consistent with zero; when averaged over l = 2-7, l(l + 1)C {sup BB}{sub l}/(2{pi}) < 0.055 {mu}K{sup 2} (95% CL). The upper limit on tensor modes from polarization data alone is a factor of two lower with the seven-year data than it was using the five-year data. The data remain consistent with the simple {Lambda}CDM model: the best-fit TT spectrum has an effective {chi}{sup 2} of 1227 for 1170 degrees of freedom, with a probability to exceed of 9.6%. The allowable volume in the six-dimensional space of {Lambda}CDM parameters has been reduced by a factor of 1.5 relative to the five-year volume, while the {Lambda}CDM model that allows for tensor modes and a running scalar spectral index has a factor of three lower volume when fit to the seven-year data. We test the parameter recovery process for bias and find that the scalar spectral index, n{sub s} , is biased high, but only by 0.09{sigma}, while the remaining parameters are biased by <0.15{sigma}. The improvement in the third peak measurement leads to tighter lower limits from WMAP on the number of relativistic degrees of freedom (e.g., neutrinos) in the early universe: N{sub eff}>2.7(95%CL). Also, using WMAP data alone, the primordial helium mass fraction is found to be Y{sub He} = 0.28{sup +0.14}{sub -0.15}, and with data from higher-resolution cosmic microwave background experiments included, we now establish the existence of pre-stellar helium at >3{sigma}. These new WMAP measurements provide important tests of big bang cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Replacement correction factors for cylindrical ion chambers in electron beams

Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P{sub repl} (or the product p{sub dis}p{sub cav} in the IAEA's notation), was conceptually separated into two components: the gradient correction (P{sub gr}) accounting for the effective point of measurement and the fluence correction (P{sub fl}) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d{sub max}), P{sub gr} is taken as 1. There are experimental data available at d{sub max} for the values of P{sub fl} (or P{sub repl}). In the TG-51 dosimetry protocol, the calibration is at the reference depth d{sub ref}=0.6R{sub 50}-0.1 (cm) where P{sub gr} is required for cylindrical chambers and P{sub fl} is unknown and so the measured values at d{sub max} are used with the corresponding mean electron energy at d{sub ref}. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} and P{sub fl} are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P{sub gr} as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P{sub fl} are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P{sub fl} for cylindrical chambers at d{sub ref} in electron beams is derived as a function of the chamber radius and the beam quality specifier R{sub 50}. Conclusions: The mean electron energy at depth is a good beam quality specifier for P{sub fl}. Thus TG-51's adoption of P{sub fl} at d{sub max} with the same mean electron energy for use at d{sub ref} is proven to be accurate. The values of P{sub gr} for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cloud Shortwave Optical Properties

The data set consists of calibrated zenith shortwave spectral radiances (400-950 nm and 940-1665 nm) and cloud optical depth (COD) retrievals every 2 seconds. The field of view is 0.5 degree. Retrievals of cloud droplet effective radius and thermodynamic phase are currently experimental and done offline. Effective radius and phase are not in this data set.

54 ENVIRONMENTAL SCIENCES↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗

Monitoring spatiotemporal evolution of fractures during hydraulic stimulations at the first EGS collab testbed using anisotropic elastic-waveform inversion

The EGS Collab project acquired continuous active-source seismic monitoring (CASSM) data before, during, and after hydraulic stimulations at the first testbed at the depth of 4850 ft (1478 m) at the Sanford Underground Research Facility in Lead, South Dakota, for monitoring fracture creation and evolution. CASSM acquisition was conducted using 24 hydrophones, 18 accelerometers, and 17 piezoelectric sources within four fracture-parallel wells and two orthogonal wells. 3D anisotropic traveltime tomography and anisotropic elastic-waveform inversion of the campaign cross-borehole seismic data show that the rock within the stimulation region is a heterogeneous horizontal transverse isotropic medium. Here we use these inversion results as the initial models and apply 3D anisotropic first-arrival traveltime tomography and 3D anisotropic elastic-waveform inversion to the CASSM data acquired after each stimulation in May, 2018 and December, 2018. We observe the spatiotemporal evolution of seismic velocities and anisotropic parameters caused by hydraulic fracture stimulations, showing the regions of rock alternation caused by hydraulic fracture stimulation.

15 GEOTHERMAL ENERGY↗

MO-F-16A-01: Implementation of MPPG TPS Verification Tests On Various Accelerators

Purpose: To demonstrate the implementation of the Medical Physics Practice Guideline (MPPG) for dose calculation and beam parameters verification of treatment planning systems (TPS). Methods: We implemented the draft TPS MPPG for three linacs: Varian Trilogy, TomoHDA and Elekta Infinity. Static and modulated test plans were created. The static fields are different than used in commissioning. Data was collected using ion chambers and diodes in a scanning water tank, Delta4 phantom and a custom phantom. MatLab and Microsoft Excel were used to create analysis tools to compare reference DICOM dose with scan data. This custom code allowed for the interpolation, registration and gamma analysis of arbitrary dose profiles. It will be provided as open source code. IMRT fields were validated with Delta4 registration and comparison tools. The time for each task was recorded. Results: The tests confirmed the strengths, and revealed some limitations, of our TPS. The agreement between calculated and measured dose was reported for all beams. For static fields, percent depth dose and profiles were analyzed with criteria in the draft MPPG. The results reveal areas of slight mismatch with the model (MLC leaf penumbra, buildup region.) For TomoTherapy, the IMRT plan 2%/2 mm gamma analysis revealed poorest agreement in the low dose regions. For one static test plan for all 10MV Trilogy photon beams, the plan generation, scan queue creation, data collection, data analysis and report took 2 hours, excluding tank setup. Conclusions: We have demonstrated the implementation feasibility of the TPS MPPG. This exercise generated an open source tool for dose comparisons between scan data and DICOM dose data. An easily reproducible and efficient infrastructure with streamlined data collection was created for repeatable robust testing of the TPS. The tests revealed minor discrepancies in our models and areas for improvement that are being investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Groundwater elevation data for monitoring wells within the East and Taylor River basins, Colorado (USA)

This dataset is comprised of temporal variations in groundwater elevation data for the 24 monitoring wells located throughout the East River watershed. Seasonal to annual variations in groundwater elevations are a critical property of mountainous watersheds needed to understand both hydrological and below ground biogeochemical processes. Such data serve as a critical constraint for numerical models describing coupled groundwater-surface water behavior within the watershed. Additionally, the offset between the maximum and minimum groundwater elevations defines the extent of the bedrock weathering zone, with annual excursions in the groundwater hydrographic (i.e., the rising and falling hydrographic limbs) imposing primary controls on bedrock saturation state and redox conditions that govern biogeochemical reactions impacting nitrogen, carbon, and metals cycling. Manufacturer-specific software is used to download pressure data from each transducer, with broadly available spreadsheet software (e.g. Microsoft Excel) used to convert temporal variations in water pressure to elevations in units of meters above mean sea level. As additional monitoring wells are installed within the East River watershed and new groundwater monitoring wells are installed in the Taylor River watershed, temporal groundwater elevation data will be included as a part of this master dataset. Details regarding the metadata associated with each monitoring well location, including well depths, screened intervals, well location coordinates, and bedrock type, are included, as is a standard operating procedure for generating groundwater elevation data from water pressure values recorded by the pressure transducers. This dataset includes: (1) a zip file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.zip), containing (a) PNG of groundwater hydrographs, (b) a CSV file with groundwater elevation data, and (c) CSV file containing metadata organized by location; (2) an Excel file (East_River_Watershed_Compiled_Groundwater_Elevation_Data_Plots.xlsx) with the groundwater elevation data, groundwater hydrographs, and metadata organized by location; (3) a Word file (Groundwater_elevation_data_protocols.docx) and a PDF file version (Groundwater_elevation_data_protocols.pdf) containing field protocols and methods; (4) a location metadata (locations.csv) file; (5) a file level metadata (flmd.csv); and (6) data dictionary (dd.csv) file.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Characterization of unconventional electron fields for the treatment of mycosis fungoides using the total skin irradiation technique

Mycosis fungoides is a cutaneous lymphoma that accounts for 2–3% of all lymphomas. Several clinical studies have demonstrated the effectiveness of TSEBT (Total Skin Electron Beam Therapy) in patients with mycosis fungoides. It is important to develop this technique and make it available to a larger number of patients in Mexico. Because large fields for electron TSEBT are required in order to cover the entire body of the patient, beam characterization at conventional treatment distances is not sufficient and a calibration distance of 500cm or higher is required. Materials and methods: Calibration of radiochromic Gafchromic® EBT2 film (RCF) for electrons was performed in a solid water phantom (Scanditronix Wellhöfer) at a depth of 1.4cm and a Source Axis Distance (SAD) of 100cm. A polynomial fit was applied to the calibration curve, in order to obtain the equation relating dose response with optical density. The spatial distribution is obtained in terms of percentage of the dose, placing 3×3cm samples of RCF on the acrylic screen, which is placed in front of the patient in order to obtain maximum absorbed dose on the skin, covering an area of 200×100cm{sup 2}. The Percentage Depth Dose (PDD) curve was obtained placing RCF samples at depths of 0, 1, 1.2, 1.4, 1.5, 2, 3, 4, 5, 6, 7, 8 and 9cm in the solid water phantom, irradiated with an ELEKTA SINERGY Linear Accelerator electron beam, with an energy of 6 MeV, at a Source Skin Distance (SSD) of 500cm, with 1000MU = 100Gy, with a cone of 40×40cm and gantry angle of 90°. The RCFs were scanned on a flatbed scanner (EPSON EXPRESSION 10000 XL) and the images were processed with the ImageJ program using a region of interest (ROI) of 1×1cm{sup 2}. Results: The relative spatial dose distribution and the percentage depth dose for a SSD of 500±0.5cm, over an area of 200×100cm{sup 2} was obtained, resulting to an effective maximum dose depth (Z{sub ref}) for electrons of 1.4±0.05cm. Using the same experimental data, horizontal and vertical beam profiles were also graphed, showing a horizontal symmetry of ±035%, horizontal flatness of ±3.62%, vertical symmetry of ±2.1% and vertical flatness of ±14.2%. Conclusions: The electron beam was characterized and the data obtained were useful to determine the spatial dose distribution to a SSD of 500±0.5cm, in an area of 200×100cm{sup 2}. Dose profiles were obtained both horizontally and vertically, thus allowing to assess electron beam symmetry and flatness. PDD analysis up to a depth of 9±0.05cm, has made possible to establish the depth of electron penetration, assuring an only skin irradiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changuinola peat soil characteristics and gas emission raw data October 2019

This dataset comprises radiocarbon and geochemical measurements from peat and porewater samples collected across various depths at a site in Bocas del Toro, Panama. The study focuses on carbon cycling dynamics in tropical peatlands by examining carbon isotopic signatures (¹⁴C and ¹³C) and elemental compositions of bulk peat, dissolved organic carbon (DOC), carbon dioxide (CO₂), and methane (CH₄). Key parameters include radiocarbon ages and isotopic ratios (δ¹³C) of bulk peat, concentrations of carbon (%C) and nitrogen (%N), and radiocarbon content of porewater gases and dissolved organic carbon (DOC). The data provide insights into the vertical and spatial distribution of carbon sources and possible preservation and decomposition processes within tropical peat profiles, offering critical information for understanding carbon storage and greenhouse gas emissions in these ecosystems.This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) carbon isotopic signatures (¹⁴C and ¹³C); (5) concentrations of carbon (%C) and nitrogen (%N); (6) radiocarbon content of porewater carbon dioxide (CO₂), and methane (CH₄) ; (7) porewater DOC; (8) bulk peat sampling protocol; (9) porewater sampling protocol; (10) porewater gas collection methods; and (11) gas extraction methods. All files are in .csv format and can be opened with any software that supports this file types.

54 ENVIRONMENTAL SCIENCES↗

The OME Framework for genome-scale systems biology

The life sciences are undergoing continuous and accelerating integration with computational and engineering sciences. The biology that many in the field have been trained on may be hardly recognizable in ten to twenty years. One of the major drivers for this transformation is the blistering pace of advancements in DNA sequencing and synthesis. These advances have resulted in unprecedented amounts of new data, information, and knowledge. Many software tools have been developed to deal with aspects of this transformation and each is sorely needed. However, few of these tools have been forced to deal with the full complexity of genome-scale models along with high throughput genome-scale data. This particular situation represents a unique challenge, as it is simultaneously necessary to deal with the vast breadth of genome-scale models and the dizzying depth of high-throughput datasets. It has been observed time and again that as the pace of data generation continues to accelerate, the pace of analysis significantly lags behind. It is also evident that, given the plethora of databases and software efforts, it is still a significant challenge to work with genome-scale metabolic models, let alone next-generation whole cell models. We work at the forefront of model creation and systems scale data generation. The OME Framework was borne out of a practical need to enable genome-scale modeling and data analysis under a unified framework to drive the next generation of genome-scale biological models. Here we present the OME Framework. It exists as a set of Python classes. However, we want to emphasize the importance of the underlying design as an addition to the discussions on specifications of a digital cell. A great deal of work and valuable progress has been made by a number of communities towards interchange formats and implementations designed to achieve similar goals. While many software tools exist for handling genome-scale metabolic models or for genome-scale data analysis, no implementations exist that explicitly handle data and models concurrently. The OME Framework structures data in a connected loop with models and the components those models are composed of. This results in the first full, practical implementation of a framework that can enable genome-scale design-build-test. Over the coming years many more software packages will be developed and tools will necessarily change. However, we hope that the underlying designs shared here can help to inform the design of future software.

59 BASIC BIOLOGICAL SCIENCES↗

THE INFRARED ARRAY CAMERA DARK FIELD: FAR-INFRARED TO X-RAY DATA

We present 20 band photometry from the far-IR to X-ray in the Spitzer Infrared Array Camera (IRAC) dark field. The bias for the near-IR camera on Spitzer is calibrated by observing a {approx}20' diameter 'dark' field near the north ecliptic pole roughly every two-to-three weeks throughout the mission duration of Spitzer. The field is unique for its extreme depth, low background, high quality imaging, time-series information, and accompanying photometry including data taken with Akari, Palomar, MMT, KPNO, Hubble, and Chandra. This serendipitous survey contains the deepest mid-IR data taken to date. This data set is well suited for studies of intermediate-redshift galaxy clusters, high-redshift galaxies, the first generation of stars, and the lowest mass brown dwarfs, among others. This paper provides a summary of the data characteristics and catalog generation from all bands collected to date as well as a discussion of photometric redshifts and initial and expected science results and goals. To illustrate the scientific potential of this unique data set, we also present here IRAC color-color diagrams.

79 ASTRONOMY AND ASTROPHYSICS↗

Basic Data Report for Well Plugging and Abandonment Activities for Fiscal Year 2009

The Waste Isolation Pilot Plant (WIPP) facility is a U.S. Department of Energy (DOE) facility for disposal of transuranic mixed waste under a permit issued by the New Mexico Environment Department. The WIPP facility is 26 miles southeast of Carlsbad, New Mexico, in eastern Eddy County. Disposal panels are mined in the Permian Salado Formation at a depth of 2,150 feet below ground surface (bgs). Field activities for this Basic Data Report were initiated in June 2009, and concluded in July 2009. The FY 2009 program included the plugging and abandonment (P&A) of two monitoring wells, which permanently removed them from the monitoring network. This Basic Data Report presents the summary of procedures followed for each well completion as documented by the Subcontract Technical Representative (STR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A mechanistic model for depth-dependent hardness of ion irradiated metals

A mechanistic model was developed for modeling the depth-dependent hardness in ion irradiated metallic materials. The model is capable of capturing the indentation size effect, ion irradiation induced damage gradient effect, and effect of unirradiated region acting as a soft substrate. A procedure was developed and described in detail to parametrize the model based on experimentally obtained hardness vs. indentation depth curves. Very good agreement was observed between our model predictions and experimental data of several different stainless steels subjected to various ion irradiation conditions. Additionally, two hardening mechanisms are revealed in the new model. One is the well-known indentation size effect arising from the creation of geometrically necessary dislocations as the indenter pierces into the materials. The other is the irradiation hardening due to the presence of irradiation-induced defects. As a function of indentation depth h, the hardening due to indentation size effect is described by $\bar{h}^*/h$, while the hardening due to irradiation first follows a power law form $ph^n$, then changes to Z/h - Q/h 3 , where $\bar{h}^*$, P, n, Z and Q > 0 are constants. This transition occurs at the indentation depth when the plastic zone reaches the end of the irradiated layer.

36 MATERIALS SCIENCE↗