Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this report. The Cr oxidation front (depth to which soluble Cr was detected) for the Cast Stone sample exposed for 68 days to ambient outdoor temperatures and humid air (total age of sample was 131 days) was determined to be about 35 mm below the top sample surface exposed. The Tc oxidation front, depth at which Tc was insoluble, was not determined. Interpretation of the results indicates that the oxidation front is at least 38 mm below the exposed surface. The sample used for this measurement was exposed to ambient laboratory conditions and humid air for 50 days. The total age of the sample was 98 days. Technetium appears to be more easily oxidized than Cr in the Cast Stone matrix. The oxidized forms of Tc and Cr are soluble and therefore leachable. Longer exposure times are required for both the Cr and Tc spiked samples to better interpret the rate of oxidation. Tc spiked subsamples need to be taken further from the exposed surface to better define and interpret the leachable Tc profile. Finally Tc(VII) reduction to Tc(IV) appears to occur relatively fast. Results demonstrated that about 95 percent of the Tc(VII) was reduced to Tc(IV) during the setting and very early stage setting for a Cast Stone sample cured 10 days. Additional testing at longer curing times is required to determine whether additional time is required to reduce 100 % of the Tc(VII) in Cast Stone or whether the Tc loading exceeded the ability of the waste form to reduce 100 % of the Tc(VII). Additional testing is required for samples cured for longer times. Depth discrete subsampling in a nitrogen glove box is also required to determine whether the 5 percent Tc extracted from the subsamples was the result of the sampling process which took place in air. Reduction capacity measurements (per the Angus-Glasser method) performed on depth discrete samples could not be correlated with the amount of chromium or technetium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium and technetium (i.e., effective Cr and Tc oxidation fronts). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) or Tc(VII) in the presence of oxygen. Depth discrete sampling and leaching is a useful for evaluating Cast Stone and other chemically reducing waste forms containing ground granulated blast furnace slag (GGBFS) or other reduction / sequestration reagents to control redox sensitive contaminant chemistry and leachability in the near surface disposal environment. Based on results presented in this report, reduction capacity measured by the Angus-Glasser Ce(IV) method is not an appropriate or meaningful parameter for determining or predicting Tc and Cr oxidation / retentions, speciation, or solubilities in cementitious materials such as Cast Stone. A model for predicting Tc(IV) oxidation to soluble Tc(VII) should consider the waste form porosity (pathway for oxygen ingress), oxygen source, and the contaminant specific oxidation rates and oxidation fronts. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance. This information can be used to support conceptual model development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-47: A Monte Carlo Model of a Spot Scanning Proton Beam Based On a Synchrotron Proton Therapy Accelerator

Purpose: To build the model of a spot scanning proton beam for the dose calculation of a synchrotron proton therapy accelerator, which is capable of accelerating protons from 50 up to 221 MeV. Methods: The spot scanning beam nozzle is modeled using TOPAS code, a simulation tool based on Geant4.9.6. The model contained a beam pipe vacuum window, a beam profile monitor, a drift chamber, two plane-parallel ionization chambers, and a spot-position monitor consisted of a multiwire ionization chamber. A water phantom is located with its upstream surface at the isocenter plane. The initial proton beam energy and anglar deflection are modeled using a Gaussian distribution with FWHM (Full Widths at Half Maximum) deponding on its beam energy. The phase space file (PSF) on a virtual surface located at the center between the two magnets is recorded. PSF is used to analyze the pencil beam features and offset the pencil beam position. The source model parameters are verificated by fitting the simulated Result to the measurement. Results: The simulated percentage depth dose (PDD) and lateral profiles of scanning pencil beams of various incident proton energies are verificated to the measurement. Generally the distance to agreement (DTA) of Bragg peaks is less than 0.2cm. The FWHM of Gaussian anglar distribution was adjusted to fit the lateral profile difference between the simulation and the measurement to less than 2∼3cm. Conclusion: A Monte Carlo model of a spot scanning proton beam was bullt based on a synchrotron proton therapy accelerator. This scanning pencil beam model will be as a block to build the broad proton beam as a proton TPS dose verification tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-sky aerosol direct radiative effects at the ARM SGP site

All-sky aerosol direct radiative effect (DRE) was estimated for the first time at the Atmospheric Radiation Measurement Southern Great Plains site using multi-year ground-based observations. The NASA Langley Fu-Liou radiation model was employed. Observed inputs for the radiation model include aerosol and cloud vertical extinction profile from Raman lidar; spectral aerosol optical depth, single-scattering albedo, and asymmetry factor from Aerosol Robotic Network; cloud water content profiles from radars; temperature and water vapor profiles from radiosondes; and surface shortwave spectral albedo from radiometers. A cloudy-sky radiative closure experiment was performed. The relative mean differences between modeled and observed surface downwelling shortwave total fluxes were 6% (7%) for transparent (opaque) cloudy-skies. The estimated annual mean all-sky aerosol DRE is -2.13±0.54W m -2 at the top of atmosphere (TOA) and -5.95±0.87 W m -2 at the surface, compared to -3.00±0.58 W m -2 AND -6.85±1.00 W m -2 , respectively, under clear-sky conditions. The seasonal cycle of all-sky aerosol DRE is similar to that of the clear-sky, except with secondary influences of the clouds: The cloud radiative effect is strongest (most negative) in the spring, which reduces the all-sky aerosol DRE. The relative uncertainties in all-sky aerosol DRE due to measurement errors are generally comparable to those in clear-sky conditions except for the aerosol single-scattering albedo. Finally, the TOA all-sky aerosol DRE relative uncertainty due to aerosol single-scattering albedo uncertainty is larger than that in clear-sky, leading to a larger total relative uncertainty. The measurement errors in cloud properties have small effects on the all-sky aerosol DRE.

54 ENVIRONMENTAL SCIENCES↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Utah FORGE: Fiber Optic Cumulative Strain Change and Strain Change Rate Data From Well 16A Stimulation at Well 16B

This dataset includes Rayleigh Frequency Shift (RFS) Distributed Strain Sensing (DSS) cumulative strain change and change rate data. The data was acquired during the stimulation of Utah FORGE Well 16A(78)-32 in April 2024 via fiber installed in Well 16B(78)-32. The fiber optic data was acquired using Neubrex SR7000 RFS DSS Distributed Strain sensing instruments and is saved here in the format of HDF5 files (.h5 extension). The spatial sampling on the full wellbore profiles is 0.20 centimeters. The data is the far field strain change response from a baseline profile made down the 16B well on April 3, 2024, so each strain value represents the strain change or strain change rate at each depth relative to the baseline reference profile. The data arrays for each type share the same dimensions (number of channels and time stamps).

15 GEOTHERMAL ENERGY↗

SU-E-T-239: Monte Carlo Modelling of SMC Proton Nozzles Using TOPAS

Purpose: To expedite and cross-check the commissioning of the proton therapy nozzles at Samsung Medical Center using TOPAS. Methods: We have two different types of nozzles at Samsung Medical Center (SMC), a multi-purpose nozzle and a pencil beam scanning dedicated nozzle. Both nozzles have been modelled in Monte Carlo simulation by using TOPAS based on the vendor-provided geometry. The multi-purpose nozzle is mainly composed of wobbling magnets, scatterers, ridge filters and multi-leaf collimators (MLC). Including patient specific apertures and compensators, all the parts of the nozzle have been implemented in TOPAS following the geometry information from the vendor.The dedicated scanning nozzle has a simpler structure than the multi-purpose nozzle with a vacuum pipe at the down stream of the nozzle.A simple water tank volume has been implemented to measure the dosimetric characteristics of proton beams from the nozzles. Results: We have simulated the two proton beam nozzles at SMC. Two different ridge filters have been tested for the spread-out Bragg peak (SOBP) generation of wobbling mode in the multi-purpose nozzle. The spot sizes and lateral penumbra in two nozzles have been simulated and analyzed using a double Gaussian model. Using parallel geometry, both the depth dose curve and dose profile have been measured simultaneously. Conclusion: The proton therapy nozzles at SMC have been successfully modelled in Monte Carlo simulation using TOPAS. We will perform a validation with measured base data and then use the MC simulation to interpolate/extrapolate the measured data. We believe it will expedite the commissioning process of the proton therapy nozzles at SMC.

07 ISOTOPE AND RADIATION SOURCES↗

Identification and Characterization of Persistent Cold Pool Events from Temperature and Wind Profilers in the Columbia River Basin

Cold pool events occur when deep layers of stable, cold air remain trapped in a valley or basin for multiple days, without mixing out from daytime heating. With large impacts on air quality, freezing events, and es-pecially on wind energy production, they are often poorly forecast by modern mesoscale numerical weather prediction (NWP) models. Understanding the characteristics of cold pools is, therefore, important to provide more accurate forecasts. This study analyzes cold pool characteristics with data collected during the Second Wind Forecast Improvement Project (WFIP2), which took place in the Columbia River basin and Gorge of Oregon and Washington from fall 2015 until spring 2017. A subset of the instrumentation included three microwave radiometer pro?lers, six radar wind pro?lers with radio acoustic sounding systems, and seven sodars, which together provided seven sites with collocated vertical pro?les of temperature, humidity, wind speed, and wind direction. Using these collocated observations, we developed a set of criteria to determine if a cold pool was present based on stability, wind speed, direction, and temporal continuity, and then developed an automated algorithm based on these criteria to identify all cold pool events over the 18 months of the ?eld project. Characteristics of these events are described, including statistics of the wind speed distributions and pro?les, stability conditions, cold pool depths, and descent rates of the cold pool top. The goal of this study is a better understanding of these characteristics and their processes to ultimately lead to improved physical parameterizations in NWP models, and consequently improve forecasts of cold pool events in the study region as well at other locations that experiences similar events.

McCaffrey, Katherine L.↗

SU-E-T-384: Experimental Verification of a Monte Carlo Linear Accelerator Model Using a Radiochromic Film Stack Dosimeter

Purpose: To experimentally verify a Monte Carlo (MC) linear accelerator model for the simulation of intensity-modulated radiation therapy (IMRT) treatments of moving targets. Methods: A Varian Clinac™ 21EX linear accelerator was modeled using the EGSnrc user code BEAMnrc. The mean energy, radial-intensity distribution, and divergence of the electron beam incident on the bremsstrahlung target were adjusted to achieve agreement between simulated and measured percentage-depth-dose and transverse field profiles for a 6 MV beam. A seven-field step-and-shoot IMRT lung procedure was prepared using Varian Eclipse™ treatment planning software. The plan was delivered using a Clinac™ 21EX linear accelerator and measured with a Gafchromic™ EBT2 film stack dosimeter (FSD) in two separate static geometries: within a cylindrical water-equivalent-plastic phantom and within an anthropomorphic chest phantom. Two measurements were completed in each setup. The dose distribution for each geometry was simulated using the EGSnrc user code DOSXYZnrc. MC geometries of the treatment couch, cylindrical phantom, and chest phantom were developed by thresholding CT data sets using MATLAB™. The FSD was modeled as water. The measured and simulated dose distributions were normalized to the median dose within the FSD. Results: Using an electron beam with a mean energy of 6.05 MeV, a Gaussian radial-intensity distribution with a full width at half maximum of 1.5 mm, and a divergence of 0°, the measured and simulated dose profiles agree within 1.75% and 1 mm. Measured and simulated dose distributions within both the cylindrical and chest phantoms agree within 3% over 94% of the FSD volume. The overall uncertainty in the FSD measurements is 3.1% (k=1). Conclusion: MC simulations agree with FSD measurements within measurement uncertainty, thereby verifying the accuracy of the linear accelerator model for the simulation of IMRT treatments of static geometries. The experimental verification will be extended to treatments of targets undergoing three-dimensional motion.

60 APPLIED LIFE SCIENCES↗

The Interaction of Relativistic Spacecrafts with the Interstellar Medium

The Breakthrough Starshot initiative aims to launch a gram-scale spacecraft to a speed of v ∼ 0.2c, capable of reaching the nearest star system, α Centauri, in about 20 years. However, a critical challenge for the initiative is the damage to the spacecraft by interstellar gas and dust during the journey. In this paper, we quantify the interaction of a relativistic spacecraft with gas and dust in the interstellar medium (ISM). For gas bombardment, we find that damage by track formation due to heavy elements is an important effect. We find that gas bombardment can potentially damage the surface of the spacecraft to a depth of ∼0.1 mm for quartz material after traversing a gas column of N{sub H}∼2×10{sup 18} cm{sup −2} along the path to α Centauri, whereas the effect is much weaker for graphite material. The effect of dust bombardment erodes the spacecraft surface and produces numerous craters due to explosive evaporation of surface atoms. For a spacecraft speed v=0.2c, we find that dust bombardment can erode a surface layer of ∼0.5 mm thickness after the spacecraft has swept a column density of N{sub H}∼3×10{sup 17} cm{sup −2}, assuming the standard gas-to-dust ratio of the ISM. Dust bombardment also damages the spacecraft surface by modifying the material structure through melting. We calculate the equilibrium surface temperature due to collisional heating by gas atoms as well as the temperature profile as a function of depth into the spacecraft. Our quantitative results suggest methods for damage control, and we highlight possibilities for shielding strategies and protection of the spacecraft.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-390: Evaluation of Heterogeneity Corrections Made by RayStation Treatment Planning

Purpose: To examine the agreement between absorbed doses calculated by RayStation treatment planning algorithm to those measured with gafchromic film and ion chamber when the photon beam is perturbed by attenuation or lateral scatter of lung material. Methods: A gafchromic EBT2 film was placed in the center of a 30×30×20 cm{sup 3} solid water phantom with a 5 cm lung slab placed at 10 cm depth. The film was irradiated at SSD = 100 cm with a 6 MV photon beam, 10×10 and 5×5 cm{sup 2} field sizes and with the beam parallel to the film and lung slab. A CT was performed to the phantom arrangement for RayStation dose calculation. The films were scanned in an Epson 10000X flatbed scanner and analyzed using the red channel, 16 bits, 76 dpi. PDD curves at the central axis and profiles at dmax were also measured in water using a CC13 (0.13 CC) ion chamber. Measurements and calculation of PDD curves at the central axis and profiles at dmax and 20 cm depth were compared using the criteria suggested by the AAPM Task Group # 53. Results: The PDD curves measured with gafchromic film and those measured in water with ion chamber agree with the ones calculated by RayStation within the uncertainty of the measurements which is within 3%. The passing rate values of the measured and calculated profiles for the 2 field sizes are within 94% for both at dmax and at 20 cm depth. Conclusion: Raystation dose calculation engine models inhomogeneity corrections. Differences between the calculated PDD curves and profiles and those measured with gafchromic film are within the uncertainty of the measurements and inside of the agreement tolerance suggested by TG53. Therefore, RayStation treatment planning has an acceptable algorithm to correct dose delivered by photon beams perturbed by lung tissue.

60 APPLIED LIFE SCIENCES↗

Blodgett Forest CA Warming Experiment phospholipid fatty acid and branched glycerol dialkyl glycerol tetraethers data 2018 from: "Whole-soil warming decreases abundance and modifies the community structure of microorganisms in the subsoil but not in surface soil".

This data package contains phospholipid fatty acid and branched glycerol dialkyl glycerol tetraethers data used for the paper: “Whole-soil warming decreases abundance and modifies the community structure of microorganisms in the subsoil but not in surface soil”. SOIL, https://doi.org/10.5194/soil-2021-14.On April 2018 (after 4.5 years of warming), we collected soil cores down to 90 cm depth from the whole soil profile warming experiment at the University of California Blodgett Forest Research Station, in the Sierra Nevada foothills near Georgetown, CA at 1370 m above sea level. Cores were collected from 6 experimental plots (three replicated blocks); samples were collected in 10 cm increments from 0 to 90 cm depth.This data package includes a file in .csv format and a file in .xlsx format, which can be accessed and processed using MS Excel or R. Phospholipid fatty acid and branched glycerol dialkyl glycerol tetraethers concentrations are provided as processed data files.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-190: Commissioning An Elekta VersaHD Linear Accelerator

Purpose: The purpose of this study is to report the dosimetric aspects of commissioning performed on an Elekta VersaHD linear accelerator with high dose rate flattening-filter-free (FFF) photon modes and electron modes. Methods: Acceptance and commissioning was performed on an Elekta VersaHD linac with 5 photon energies (6MV, 10MV, 18MV, 6FFF, 10FFF), 4 electron energies (6MeV, 9MeV, 12MeV, 15MeV) and 160 leaf (5mm wide) multi-leaf collimators (MLCs). Mechanical and dosimetric data was measured and evaluated. The measurements include percent depth doses (PDDs), inplane and crossplane profiles, head scatter factor (Sc), relative photon output factors (Scp), universal wedge transmission factor, MLC transmission factors, and electron cone factors. Results: Gantry, collimator, couch isocentricity measurements were within 1mm, 0.7mm and 0.7mm diameter respectively. The PDDs of 6FFF and 10FFF beams show deeper dmax and steeper fall-off with depth than the corresponding flattened beams. While flatness values of 6FFF and 10FFF normalized profiles were higher than the corresponding flattened beams, the symmetry values were almost identical. The crossplane penumbra values were higher than the inplane penumbra values for all the energies. The MLC transmission values were 0.5%, 0.6% and 0.6% for 6MV, 10MV, and 18MV photon beams. The electron PDDs, profiles and cone factors is validated by literature. Conclusion: The outcome of radiation treatment is directly related to the accuracy in the dose modeled in the treatment planning system which is based on the commissioned data. Commissioning data provided us a valuable insight into the dosimetric characteristics of the beam. This set of commissioning data can provide comparison data to others performing VersaHD commissioning thus improving patient safety.

60 APPLIED LIFE SCIENCES↗

SU-F-T-495: Method for Simultaneous Commissioning of Multiple Truebeam (TB) Linacs: Small Field Data and the Choice of Dosimetric Lead Gap (DLG)

Purpose: Many times a set of multiple Varian-Truebeam (TB) linacs are acquired by an institution. Since “beam matching” is an important requirement for many facilities, we developed a strategy to perform a “simultaneous” commissioning between multiple linacs.Methods and Materials: We first commissioned the required photon beam data for eclipse on the 1st TB for all the energy modalities with a beam scanning system, while integrated measurements for output factors, of all field sizes (from 1×1 to 40×40cm{sup 2}) were conducted on the 2nd TB. Care was exercised during small field dosimetry so the appropriate detectors were used with data taken between two detectors be “linked” to a larger field size (4×4cm{sup 2}) with the “daisy-chaining” technique via: OF=[M-PTW(fs)×(M-PTW(4×4))-1]×[MA12s(4×4)×(M-A12S(10×10))−1]. For all energy modalities, data that span the entire range of field size, was repeated on the next TB linac, for verification. The primarily energy-dependent dosimetric leaf gap (DLG) which was measured separately on each TB. The modeled data was validated with special measurements conducted on both linacs during commissioning. Results: Our data agreed with the “TB representative beam data” to within 0.5% for all energy modalities and field sizes ≥3×3cm2. Sample depth-doses and cross-profiles of a 3×3cm2 between the linacs agreeing to within 1% between linacs. The measured DLGs were quite different with a uniform difference of 1.3% between the two linacs. The measured DLG values are independent of the average dose rate and medium used for the measurements. Conclusion: A comprehensive method of commissioning identical Varian-TB linacs, outlining the critical issues, especially small field dosimetry and DLG. The dosimetric effect of different DLG values, when it comes to, dynamic delivery and data comparisons will be presented. The dependence of DLG value on the measurement medium (in-air vs. water) or dose rate used will also be discussed. This work was supported by CAMC Cancer Center and Alliance Oncology.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of parasound data for sediment study on methane seep site at Simeulue basin

The Parasound data presents sea depth and sub-bottom profiler. In terms of geological terminology, parasound data represents significant recent surface sedimentary structures that valuable for the selection of subsequent sampling site such as sampling at methane seep site. Therefore, Parasound is used to detailing methane seep at surface sediment following seismic data interpretation. In this study, parasound is used to focus observe area especially for sediment study on methane seep site. The Parasound systems works both as narrow beam sounder use high frequency and as sediment echosounder use low frequency. Parasound acquisition applies parametric effect. It produces additional frequency by nonlinear acoustic interaction of finite amplitude waves. Parasound transducers have 128 elements on 1 m2 and need transmission power up to 70 kW. The results of this study are discovered large seep carbonate with porous surface which means there are gas expulsions passing through that rock.

58 GEOSCIENCES↗

Inflow Characterization for Marine and Hydrokinetic Energy Devices. FY-2010 Annual Progress Report

Marine and Hydro Kinetic devices (MHK) are being widely studied as a source of renewable energy. The Marrowstone Island site is a potential location for installing MHK devices because the tidal currents observed that are sufficient for power generation. In order to quantify the effects of turbulence on MHK devices and the surrounding environment at this site, a prelimi- nary fluid flow field study was conducted here by the Pacific Northwest National Lab (PNNL) in collaboration with the Applied Physics Lab at the University of Washington (APL-UW). This study entailed continuous The Acoustic Doppler Velocimetry (ADV), Acoustic Doppler Current Profiler (ADCP) and Conductivity, Temperature and Depth (CTD) measurements from May 4, 2010 to May 22, 2010, in order to obtain information about turbulence effects during different tidal conditions. The instruments used for collecting the above measurements were deployed at the Marrowstone site using a R/V Jack Robertson provided by the University of Washington (APL-UW). All the measurements were taken at the site with an average depth of 22 m below the sea surface. ADV acquired velocity data at 32 Hz sampling frequency at 4.6 m above the seabed, and ADCP acquired velocity profile data at a sampling frequency of 2 Hz, from a height of 2.6 m above the seabed to the surface with a bin resolution of 0.5 m. The ADV and ADCP measurements showed that the horizontal velocity had a turbulence intensity of 10%. Further- more, the spectral analysis from ADV measurements showed that the flow is fully turbulent with -5/3 slope in the inertial sub-range of the spectra. Moreover, the temporal-frequency analysis showed presence of ”eddies” at high frequencies. These preliminary studies provided initial flow field and site characteristics, showed the limitations of the instruments used and highlighted changes that need to be made in the experimental setup for deployment in FY-2011 studies.

13 HYDRO ENERGY↗

ARCHER{sub RT} – A GPU-based and photon-electron coupled Monte Carlo dose computing engine for radiation therapy: Software development and application to helical tomotherapy

Purpose: Using the graphical processing units (GPU) hardware technology, an extremely fast Monte Carlo (MC) code ARCHER{sub RT} is developed for radiation dose calculations in radiation therapy. This paper describes the detailed software development and testing for three clinical TomoTherapy® cases: the prostate, lung, and head and neck. Methods: To obtain clinically relevant dose distributions, phase space files (PSFs) created from optimized radiation therapy treatment plan fluence maps were used as the input to ARCHER{sub RT}. Patient-specific phantoms were constructed from patient CT images. Batch simulations were employed to facilitate the time-consuming task of loading large PSFs, and to improve the estimation of statistical uncertainty. Furthermore, two different Woodcock tracking algorithms were implemented and their relative performance was compared. The dose curves of an Elekta accelerator PSF incident on a homogeneous water phantom were benchmarked against DOSXYZnrc. For each of the treatment cases, dose volume histograms and isodose maps were produced from ARCHER{sub RT} and the general-purpose code, GEANT4. The gamma index analysis was performed to evaluate the similarity of voxel doses obtained from these two codes. The hardware accelerators used in this study are one NVIDIA K20 GPU, one NVIDIA K40 GPU, and six NVIDIA M2090 GPUs. In addition, to make a fairer comparison of the CPU and GPU performance, a multithreaded CPU code was developed using OpenMP and tested on an Intel E5-2620 CPU. Results: For the water phantom, the depth dose curve and dose profiles from ARCHER{sub RT} agree well with DOSXYZnrc. For clinical cases, results from ARCHER{sub RT} are compared with those from GEANT4 and good agreement is observed. Gamma index test is performed for voxels whose dose is greater than 10% of maximum dose. For 2%/2mm criteria, the passing rates for the prostate, lung case, and head and neck cases are 99.7%, 98.5%, and 97.2%, respectively. Due to specific architecture of GPU, modified Woodcock tracking algorithm performed inferior to the original one. ARCHER{sub RT} achieves a fast speed for PSF-based dose calculations. With a single M2090 card, the simulations cost about 60, 50, 80 s for three cases, respectively, with the 1% statistical error in the PTV. Using the latest K40 card, the simulations are 1.7–1.8 times faster. More impressively, six M2090 cards could finish the simulations in 8.9–13.4 s. For comparison, the same simulations on Intel E5-2620 (12 hyperthreading) cost about 500–800 s. Conclusions: ARCHER{sub RT} was developed successfully to perform fast and accurate MC dose calculation for radiotherapy using PSFs and patient CT phantoms.

60 APPLIED LIFE SCIENCES↗

Light-absorbing impurities accelerating glacial melting in southeastern Tibetan Plateau

Deposition of light-absorbing particles on glacier surfaces poses a series of adverse impacts on the cryospheric environment, climate and human health. Broad attention of the scientific community has been paid on insoluble light-absorbing impurities (ILAIs) in snow and ice on glaciers over the Tibetan Plateau (TP). However, systematic investigation of ILAIs in snowpack of glaciers on the TP is scarce. In this study, the properties and darkening effect of ILAIs in snowpack on glaciers are extensively investigated in the southeast of TP. Results show that ILAIs concentrations in multiple types of snow and ice samples were significantly different. Snowpit depths varied substantially from one profile to another during May and June 2016. The average concentrations of ILAIs in snowpits increase as snow melting progresses. Black carbon (BC) and dust cause snow albedo reduction more in snow with larger grain size Re. Based on a radiative transfer model calculation, the average albedo reduction induced by BC in the snowpack was 0.141 ± 0.02, and associated daily maximum radiative forcing (RF) was 72.97 ± 12.7 W m-2. BC is a controlling light-absorbing factor in snowpack and causes substantial albedo reduction and thus the associated daily maximum RF. The maximum reduction of snow cover duration was 4.56 ± 0.71 days caused by BC and dust in snowpack in southeastern TP. The average mass absorption cross-section (MAC) of BC from multiple snowpits was 3.26 ± 0.46 m2 g-1, which represents a typical value of MAC in snow on glaciers, but it is type-dependent of snow/ice samples. Tropospheric aerosols vertically extended up to 8 km over the TP and its surrounding areas, which indicates the transport of aerosols from remote sources through elevated pathways. A large amount of carbon stored in the brittle glaciers can be potentially released with meltwater runoff under a warming climate. This study provides a new insight for investigating carbonaceous and light-absorbing particles in glacierization areas.

Niu, Hewen↗

Elevated [CO2] changes soil organic matter composition and substrate diversity in an arid ecosystem

Little is known about how rising atmospheric [CO2] will impact long-term plant biomass or the dynamics of soil organic matter (SOM) in arid ecosystems. Evans et al. (1) reported higher soil organic carbon (SOC) and total nitrogen (N) concentrations following 10 years exposure to elevated atmospheric [CO2] at the Nevada Desert Free-Air-Carbon dioxide-Enrichment (FACE) Facility (NDFF). In this study, we investigated potential mechanisms that resulted in increased SOC and total N accumulation and SOM stabilization using high resolution mass spectrometry. Samples were collected from soil profiles to 1 m in depth with a 0.2 m increment under the dominant evergreen shrub Larrea tridentata. The differences in the molecular composition and diversity of SOM were more evident in surface soils and declined with depth, and were consistent with higher SOC and total N concentrations under elevated than ambient [CO2]. Our molecular analysis also suggested increased root exudation and/or microbial necromass from stabilization of labile C and N contributed to SOM and N stocks. Increased microbial activity and metabolism under elevated [CO2] compared to ambient treatments suggest that elevated [CO2] altered microbial carbon use patterns, reflecting changes in the quality and quantity of SOC inputs. We found that plant-derived compounds were primary substrates for microbial activity under elevated [CO2] and microbial products were the main constituents of stabilized SOM. Our results suggest that arid ecosystems are a potential large C sink under elevated [CO2], given the extensive coverage of the land surface, and that labile compounds are transformed to stable SOM via microbial processes. Arid systems are limited by water, and thus may have a different C storage potential under changing climates than other ecosystems that are limited by nitrogen or phosphorus.

Tfaily, Malak M.↗