Search NASA⌕ Search

SEARCH · Search NASA

Results for “device simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

CCD/CID Processors Would Offer Greater Precision

Charge-coupled-device/charge-injection-device (CCD/CID) data processors of proposed type offer advantages of massively parallel computational architecture and high computational speed typical of older CCD/CID data processors, but with increased precision. Useful in performing matrix vector multiplications in variety of applications, including solving partial differential equations, processing signal and image data, control computations, and neural-network simulations. Greater precision of proposed devices help to ensure accuracy in CCD/CID implementations of pseudospectral neural networks - particular class of artificial neural networks especially suited to solving nonlinear differential equations.

Barhen, Jacob↗

A laser gyro with a four-mirror square resonator: formulas for simulating the dynamics of the synchronisation zone parameters of the frequencies of counterpropagating waves during the device operation in the self-heating regime

For a laser gyro with a four-mirror square resonator we have developed a mathematical model, which allows one to simulate the temporal behaviour of the synchronisation zone parameters of the frequencies of counterpropagating waves in a situation when the device operates in the self-heating regime and is switched-on at different initial temperatures. (laser gyroscopes)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

14 SOLAR ENERGY↗

Comparative study of InGaP/GaAs high electron mobility transistors with upper and lower delta-doped supplied layers

Influence corresponding to the position of {delta}-doped supplied layer on InGaP/GaAs high electron mobility transistors is comparatively studied by two-dimensional simulation analysis. The simulated results exhibit that the device with lower {delta}-doped supplied layer shows a higher gate potential barrier height, a higher saturation output current, a larger magnitude of negative threshold voltage, and broader gate voltage swing, as compared to the device with upper {delta}-doped supplied layer. Nevertheless, it has smaller transconductance and inferior high-frequency characteristics in the device with lower {delta}-doped supplied layer. Furthermore, a knee effect in current-voltage curves is observed at low drain-to-source voltage in the two devices, which is investigated in this article.

36 MATERIALS SCIENCE↗

Density and potential profiles of non-neutral electron plasmas in a magnetic mirror field

Low-energy non-neutral electron plasmas were confined with an electrostatic potential and a magnetic mirror field of the mirror ratio up to 5. Using a conventional phosphor screen and the unique multiring trap, both radial and axial density profiles of plasmas were measured. With the present experimental parameters, it was confirmed that a plasma density increased at higher field with an electrostatic confinement and that it decreased at higher field with a magnetic mirror confinement. The electrostatic potentials along the magnetic field were estimated with computer simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabricated devices for performing bacterial-fungal interaction experiments across scales

Diverse and complex microbiomes are found in virtually every environment on Earth. Bacteria and fungi often co-dominate environmental microbiomes, and there is growing recognition that bacterial-fungal interactions (BFI) have significant impacts on the functioning of their associated microbiomes, environments, and hosts. Investigating BFI in vitro remains a challenge, particularly when attempting to examine interactions at multiple scales of system complexity. Fabricated devices can provide control over both biotic composition and abiotic factors within an experiment to enable the characterization of diverse BFI phenotypes such as modulation of growth rate, production of biomolecules, and alterations to physical movements. Engineered devices ranging from microfluidic chips to simulated rhizosphere systems have been and will continue to be invaluable to BFI research, and it is anticipated that such devices will continue to be developed for diverse applications in the field. This will allow researchers to address specific questions regarding the nature of BFI and how they impact larger microbiome and environmental processes such as biogeochemical cycles, plant productivity, and overall ecosystem resilience. Devices that are currently used for experimental investigations of bacteria, fungi, and BFI are discussed herein along with some of the associated challenges and several recommendations for future device design and applications.

59 BASIC BIOLOGICAL SCIENCES↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim (Wave Energy Converter SIMulator) is an open-source code for simulating wave energy converters, which has been actively developed and applied to simulate a wide variety of device archetypes and has become a popular tool since its initial release in 2014. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) within the MATLAB/SIMULINK environment. Figure 1 illustrates a general wave-to-wire model which begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of a single WEC (or array), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modelling the entire wave-to-wire is difficult and encompass multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM) based-frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Table 1 lists additional WEC-Sim functionalities, which are created using prebuilt Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems.

hydrodynamics modeling↗

Lower hybrid current drive in a high density diverted tokamak

Experimental observations of LHCD at high density (n-bar{sub e}>10{sup 20}m{approx}{sup 3}) on the Alcator C-Mod tokamak are presented in this paper. Bremsstrahlung emission from relativistic fast electrons in the core plasma drops sharply in single null discharges well below the density limit previously observed on limited tokamaks ({omega}/{omega}{sub LH}{approx}2). Modeling and experimental evidence suggest that the absence of LH driven fast electrons at high density may be due to collisional absorption in the scrape off layer. Experiments show that the expected current drive density dependence is recovered for inner wall limited discharges across the range of densities scanned (0.5x10{sup 20} m{sup -3}<n-bar{sub e}<1.5x10{sup 20} m{sup -3}). Increasing T{sub e} in the periphery of the plasma (0.8<r/a<1.0) also results in a modest increase in non-thermal electron emission at high n-bar{sub e}. Ray tracing/Fokker-Planck simulations of these discharges predict the observed sensitivity to plasma position when the effects of collisional absorption in the SOL are included in the model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terahertz oscillations in an In{sub 0.53}Ga{sub 0.47}As submicron planar Gunn diode

The length of the transit region of a Gunn diode determines the natural frequency at which it operates in fundamental mode—the shorter the device, the higher the frequency of operation. The long-held view on Gunn diode design is that for a functioning device the minimum length of the transit region is about 1.5 μm, limiting the devices to fundamental mode operation at frequencies of roughly 60 GHz. Study of these devices by more advanced Monte Carlo techniques that simulate the ballistic transport and electron-phonon interactions that govern device behaviour, offers a new lower bound of 0.5 μm, which is already being approached by the experimental evidence that has shown planar and vertical devices exhibiting Gunn operation at 600 nm and 700 nm, respectively. The paper presents results of the first ever THz submicron planar Gunn diode fabricated in In{sub 0.53}Ga{sub 0.47}As on an InP substrate, operating at a fundamental frequency above 300 GHz. Experimentally measured rf power of 28 μW was obtained from a 600 nm long × 120 μm wide device. At this new length, operation in fundamental mode at much higher frequencies becomes possible—the Monte Carlo model used predicts power output at frequencies over 300 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The visual standards for the selection and retention of astronauts, part 2

In preparation for the various studies planned for assessing visual capabilities and tasks in order to set vision standards for astronauts, the following pieces of equipment have been assembled and tested: a spectacle obstruction measuring device, a biometric glare susceptibility tester, a variable vergence amplitude testing device, an eye movement recorder, a lunar illumination simulation chamber, a night myopia testing apparatus, and retinal adaption measuring devices.

Allen, M. J.↗

Fabrication and single-electron-transfer operation of a triple-dot single-electron transistor

A triple-dot single-electron transistor was fabricated on silicon-on-insulator wafer using pattern-dependent oxidation. A specially designed one-dimensional silicon wire having small constrictions at both ends was converted to a triple-dot single-electron transistor by means of pattern-dependent oxidation. The fabrication of the center dot involved quantum size effects and stress-induced band gap reduction, whereas that of the two side dots involved thickness modulation because of the complex edge structure of two-dimensional silicon. Single-electron turnstile operation was confirmed at 8 K when a 100-mV, 1-MHz square wave was applied. Monte Carlo simulations indicated that such a device with inhomogeneous tunnel and gate capacitances can exhibit single-electron transfer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation program of nonlinearities applied to telecommunication systems

In any satellite communication system, the problems of distorsion created by nonlinear devices or systems must be considered. The subject of this paper is the use of the Fast Fourier Transform (F.F.T.) in the prediction of the intermodulation performance of amplifiers, mixers, filters. A nonlinear memory-less model is chosen to simulate amplitude and phase nonlinearities of the device in the simulation program written in FORTRAN 4. The experimentally observed nonlinearity parameters of a low noise 3.7-4.2 GHz amplifier are related to the gain and phase coefficients of Fourier Service Series. The measured results are compared with those calculated from the simulation in the cases where the input signal is composed of two, three carriers and noise power density.

Thomas, C.↗

MULTI-PHASE CFD MODELING OF A SOLID SORBENT CARBON CAPTURE SYSTEM

Post-combustion solid sorbent carbon capture systems are being studied via computational modeling as part of the U.S. Department of Energy’s Carbon Capture Simulation Initiative (CCSI). The work focuses on computational modeling of device-scale multi-phase computational fluid dynamics (CFD) simulations for given carbon capture reactor configurations to predict flow properties, outlet compositions, temperature and pressure. The detailed outputs of the device-scale models provide valuable insight into the operation of new carbon capture devices and will help in the design and optimization of carbon capture systems. As a first step in this project we have focused on modeling a 1 kWe solid sorbent carbon capture system using the commercial CFD software ANSYS FLUENT®. Using the multi-phase models available in ANSYS FLUENT®, we are investigating the use of Eulerian-Eulerian and Eulerian-Lagrangian methods for modeling a fluidized bed carbon capture design. The applicability of the dense discrete phase method (DDPM) is being considered along with the more traditional Eulerian-Eulerian multi-phase model. In this paper we will discuss the design of the 1 kWe solid sorbent system and the setup of the DDPM and Eulerian-Eulerian models used to simulate the system. The results of the hydrodynamics in the system will be discussed and the predictions of the DDPM and Eulerian-Eulerian simulations will be compared. A discussion of the sensitivity of the model to boundary and initial conditions, computational meshing, granular pressure, and drag sub-models will also be presented.

Ryan, Emily M.↗

Creation of Speed-of-Sound Inject Data for Technical Nuclear Forensics

Technical Nuclear Forensics (TNF) exercises simulate a detonation of a nuclear device within the United States, usually in a city. Speed-of-sound (SOS) phenomenology are the atmospheric overpressure and ground shock mechanical motions that are observed at over-pressure (air-blast and infrasound) and seismic sensors, respectively (Figure 1). Amplitudes of SOS data are related to the explosive yield (Kinney and Graham, 1985; Koper et al., 2002; Bonner et al., 2013ab; Ford et al., 2014, 2021; Templeton et al., 2018; Schnurr et al., 2020). Within the country, the United States Prompt Diagnostics System (USPDS) includes a network of geophysical sensors to capture such SOS signals. During the TNF exercise, the event data will be analyzed by the players who know nothing about the technical details of the source (e.g. location, yield, explosive). Specifically, they will use the Integrated Yield Determination Tool (IYDT) to estimate the yield and height-of-burst or depth-of-burial (HOB/DOB). The IYDT allows the user to measure features on the overpressure and seismic channels, evaluate the consistency of features and jointly estimate yield and HOB/DOB. For these exercises, SOS data are simulated for the location, emplacement and yield of the device and signals are propagated to the observing stations. This document describes the steps undertaken in the simulation, validation, preparation and verification of SOS signals for TNF exercises.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electron transport in unipolar InGaN/GaN multiple quantum well structures grown by NH{sub 3} molecular beam epitaxy

Unipolar-light emitting diode like structures were grown by NH{sub 3} molecular beam epitaxy on c plane (0001) GaN on sapphire templates. Studies were performed to experimentally examine the effect of random alloy fluctuations on electron transport through quantum well active regions. These unipolar structures served as a test vehicle to test our 2D model of the effect of compositional fluctuations on polarization-induced barriers. Variables that were systematically studied included varying quantum well number from 0 to 5, well thickness of 1.5 nm, 3 nm, and 4.5 nm, and well compositions of In{sub 0.14}Ga{sub 0.86}N and In{sub 0.19}Ga{sub 0.81}N. Diode-like current voltage behavior was clearly observed due to the polarization-induced conduction band barrier in the quantum well region. Increasing quantum well width and number were shown to have a significant impact on increasing the turn-on voltage of each device. Temperature dependent IV measurements clearly revealed the dominant effect of thermionic behavior for temperatures from room temperature and above. Atom probe tomography was used to directly analyze parameters of the alloy fluctuations in the quantum wells including amplitude and length scale of compositional variation. A drift diffusion Schrödinger Poisson method accounting for two dimensional indium fluctuations (both in the growth direction and within the wells) was used to correctly model the turn-on voltages of the devices as compared to traditional 1D simulation models.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Solution methods for very highly integrated circuits.

While advances in manufacturing enable the fabrication of integrated circuits containing tens-to-hundreds of millions of devices, the time-sensitive modeling and simulation necessary to design these circuits poses a significant computational challenge. This is especially true for mixed-signal integrated circuits where detailed performance analyses are necessary for the individual analog/digital circuit components as well as the full system. When the integrated circuit has millions of devices, performing a full system simulation is practically infeasible using currently available Electrical Design Automation (EDA) tools. The principal reason for this is the time required for the nonlinear solver to compute the solutions of large linearized systems during the simulation of these circuits. The research presented in this report aims to address the computational difficulties introduced by these large linearized systems by using Model Order Reduction (MOR) to (i) generate specialized preconditioners that accelerate the computation of the linear system solution and (ii) reduce the overall dynamical system size. MOR techniques attempt to produce macromodels that capture the desired input-output behavior of larger dynamical systems and enable substantial speedups in simulation time. Several MOR techniques that have been developed under the LDRD on 'Solution Methods for Very Highly Integrated Circuits' will be presented in this report. Among those presented are techniques for linear time-invariant dynamical systems that either extend current approaches or improve the time-domain performance of the reduced model using novel error bounds and a new approach for linear time-varying dynamical systems that guarantees dimension reduction, which has not been proven before. Progress on preconditioning power grid systems using multi-grid techniques will be presented as well as a framework for delivering MOR techniques to the user community using Trilinos and the Xyce circuit simulator, both prominent world-class software tools.

99 GENERAL AND MISCELLANEOUS↗

Global gyrokinetic particle simulations of microturbulence in W7-X and LHD stellarators

Global gyrokinetic particle simulations of electrostatic ion temperature gradient (ITG) instability show that the most unstable eigenmode is localized to some magnetic fieldlines or discrete locations on the poloidal plane in the Wendelstein 7-X (W7-X) stellarator due to its mirror-like magnetic fields, which vary strongly in the toroidal direction and induce coupling of more toroidal harmonics (n) to form the linear eigenmode than in the Large Helical Device (LHD) stellarator. Nonlinear electrostatic simulation results show that self-generated zonal flows are the dominant saturation mechanism for the ITG instabilities in both the LHD and W7-X. Additionally, radial widths of the fluctuation intensity in both the LHD and W7-X are significantly broadened from the linear phase to the nonlinear phase due to turbulence spreading. Finally, nonlinear spectra in the W7-X are dominated by low-n harmonics, which can be generated both by nonlinear toroidal coupling of high-n harmonics and by linear toroidal coupling with large amplitude zonal flows due to the 3D equilibrium magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗