Search NASA⌕ Search

SEARCH · Search NASA

Results for “dimensional analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

SU-E-T-313: The Accuracy of the Acuros XB Advanced Dose Calculation Algorithm for IMRT Dose Distributions in Head and Neck

Purpose: To investigate the accuracy of the Acuros XB version 11 (AXB11) advanced dose calculation algorithm by comparing with Monte Caro (MC) calculations. The comparisons were performed with dose distributions for a virtual inhomogeneity phantom and intensity-modulated radiotherapy (IMRT) in head and neck. Methods: Recently, AXB based on Linear Boltzmann Transport Equation has been installed in the Eclipse treatment planning system (Varian Medical Oncology System, USA). The dose calculation accuracy of AXB11 was tested by the EGSnrc-MC calculations. In additions, AXB version 10 (AXB10) and Analytical Anisotropic Algorithm (AAA) were also used. First the accuracy of an inhomogeneity correction for AXB and AAA algorithms was evaluated by comparing with MC-calculated dose distributions for a virtual inhomogeneity phantom that includes water, bone, air, adipose, muscle, and aluminum. Next the IMRT dose distributions for head and neck were compared with the AXB and AAA algorithms and MC by means of dose volume histograms and three dimensional gamma analysis for each structure (CTV, OAR, etc.). Results: For dose distributions with the virtual inhomogeneity phantom, AXB was in good agreement with those of MC, except the dose in air region. The dose in air region decreased in order of MC<AXB11<AXB10. This may be caused by the difference of the electron cut-off energy for algorithms, ie: 0.700 MeV for MC, 0.711 MeV for AXB11, and 1.011 MeV for AXB 10. Since the AAA algorithm is based on the dose kernel of water, the doses in regions for air, bone, and aluminum considerably became higher than those of AXB and MC. The pass rates of the gamma analysis for IMRT dose distributions in head and neck were similar to those of MC in order of AXB11<AXB10<AAA. Conclusion: The dose calculation accuracy of AXB11 was almost equivalent to the MC dose calculation.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle{sup 3}), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA verification.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 62: A Retrospective Assessment of the Prevalence and Dosimetric Effect of Lateral Electron Disequilibrium in a Population of Lung Cancer Patients Treated by Stereotactic Body Radiation Therapy

Stereotactic Body Radiation Therapy (SBRT) is a treatment option for early stage non-small cell lung cancer (NSCLC). SBRT uses tightly conformed megavoltage (MV) x-ray beams to ablate the tumour. However, small MV x-ray fields may produce lateral electron disequilibrium (LED) within lung tissue, which can reduce the dose to tumour. The goal of this work is to estimate the prevalence of LED in NSCLC patients treated with SBRT, and determine dose effects for patients prone or averse to LED. Thirty NSCLC patients were randomly selected for analysis. 4-dimensional CT lung images were segmented into the right and left upper and lower lobes (RUL, RLL, LUL, LLL), and the right middle lobe. Dose calculations were performed using volume-modulated arc therapy in the Pinnacle{sup 3} TPS. Most tumours were located in the upper lobes (RUL 53%, LUL 27%) where density was significantly lower (RUL −808±46 HU vs. RLL −743±71 HU; LUL −808 ±56 HU vs. LLL −746±70 HU; p<0.001). In general, the prevalence of LED increased with higher beam energy. Using 6MV photons, patients with a RUL tumour experienced moderate (81 %), and mild (19%) levels of LED. At 18MV, LED became more prominent with severe (50%) and moderate (50%) LED exhibited. Dosimetrically, for patients prone to LED, poorer target coverage (i.e. increased R100 by 20%) and improved lung sparing (i.e. reduced V20 by −46%) was observed. The common location of lung cancers in the upper lobes, coupled with lower lung density, results in the potential occurrence of LED, which may underdose the tumour.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-15: Verifications of Absolute and Relative Dosimetry of a Novel Stereotactic Breast Device: GammaPodTM

Purpose: A dedicated stereotactic breast radiotherapy device, GammaPod, was developed to treat early stage breast cancer. The first clinical unit was installed and commissioned at University of Maryland. We report our methodology of absolute dosimetry in multiple calibration conditions and dosimetric verifications of treatment plans produced by the system. Methods: GammaPod unit is comprised of a rotating hemi-spherical source carrier containing 36 Co-60 sources and a concentric tungsten collimator providing beams of 15 and 25 mm. Absolute dose calibration formalism was developed with modifications to AAPM protocols for unique geometry and different calibration medium (acrylic, polyethylene or liquid water). Breast cup-size specific and collimator output factors were measured and verified with respect to Monte-Carlo simulations for single isocenter plans. Multiple isocenter plans were generated for various target size, location and cup-sizes in phantoms and 20 breast cancer patients images. Stereotactic mini-farmer chamber, OSL and TLD detectors as well as radio-chromic films were used for dosimetric measurements. Results: At the time of calibration (1/14/2016), absolute dose rate of the GammaPod was established to be 2.10 Gy/min in acrylic for 25 mm for sources installed in March 2011. Output factor for 15 mm collimator was measured to be 0.950. Absolute dose calibration was independently verified by IROC-Houston with a TLD/Institution ratio of 0.99. Cup size specific output measurements in liquid water for single isocenter were found to be within 3.0% of MC simulations. Point-dose measurements of multiple isocenter treatment plans were found to be within −1.0 ± 1.2 % of treatment planning system while 2-dimensional gamma analysis yielded a pass rate of 97.9 ± 2.2 % using gamma criteria of 3% and 2mm. Conclusion: The first GammaPod treatment unit for breast stereotactic radiotherapy was successfully installed, calibrated and commissioned for patient treatments. An absolute dosimetry and dosimetric verification protocols were successfully created.

60 APPLIED LIFE SCIENCES↗

In silico analysis of the three-dimensional structures of the homodimer of uridine phosphorylase from Yersinia Pseudotuberculosis in the ligand-free state and in a complex with 5-fluorouracil

Pseudotuberculosis is an acute infectious disease characterized by a lesion of the gastrointestinal tract. A positive therapeutic effect can be achieved by selectively suppressing the activity of uridine phosphorylase from the causative agent of the disease Yersinia pseudotuberculosis. The synergistic effect of a combination of the chemotherapeutic agent 5-fluorouracil and antimicrobial drugs, which block the synthesis of pyrimidine bases, on the cells of pathogenic protozoa and bacteria is described in the literature. The three-dimensional structures of uridine phosphorylase from Yersinia pseudotuberculosis (YptUPh) both in the ligand-free state and in complexes with pharmacological agents are unknown, which hinders the search for and design of selective inhibitors of YptUPh. The three-dimensional structure of the ligand-free homodimer of YptUPh was determined by homology-based molecular modeling. The three-dimensional structure of the subunit of the YptUPh molecule belongs to {alpha}/{beta} proteins, and its topology is a three-layer {alpha}/{beta}/{alpha} sandwich. The subunit monomer of the YptUPh molecule consists of 38% helices and 24% {beta} strands. A model of the homodimer structure of YptUPh in a complex with 5-FU was obtained by the molecular docking. The position of 5-FU in the active site of the molecule is very consistent with the known data on the X-ray diffraction structures of other bacterial uridine phosphorylases (the complex of uridine phosphorylase from Salmonella typhimurium (StUPh) with 5-FU, ID PDB: 4E1V and the complex of uridine phosphorylase from Escherichia coli (EcUPh) with 5-FU and ribose 1-phosphate, ID PDB: 1RXC).

36 MATERIALS SCIENCE↗

NDDAV

Web-based Interface for the N-Dimensional Data Analysis and Visualization System.

Liu, Shusen↗

Role of Surface Friction on Shallow Nonprecipitating Convection

The role of surface friction on shallow nonprecipitating convection is investigated using a series of large-eddy simulations with varying surface friction velocity and with a cloud identification algorithm. As surface friction intensifies, convective rolls dominate over convective cells and secondary overturning circulation becomes stronger in the subcloud layer, thus transporting more moisture upward and more heat downward between the subcloud and cloud layers. Identifying individual clouds, using the identification algorithm based on a three-dimensional topological analysis, reveals that intensified surface friction increases the number of clouds and the degree of tilting in the downstream direction. Highly intensified surface friction increases wind shear across the cloud base and induces cloud tilting, which leads to a vertically parabolic profile of liquid water mixing ratio instead of the classical two-layer structure (conditionally unstable and trade inversion layers). Furthermore, cloud tilting induces more cloud cover and more cloud mass flux much above the cloud base (e.g., 0.8 < z < 1.2 km), but less cloud cover and less cloud mass flux in the upper cloud layer (e.g., z > 1.2 km) because of increased lateral entrainment rate. Similarly, profiles of directly measured entrainment and detrainment rates show that detrainment in the lower cloud layer becomes smaller with stronger surface friction.

54 ENVIRONMENTAL SCIENCES↗

Diffusion Acceleration Schemes for Self-Adjoint Angular Flux Formulation with a Void Treatment

A Galerkin weak form for the monoenergetic neutron transport equation with a continuous finite element method and discrete ordinate method is developed based on self-adjoint angular flux formulation. This weak form is modified for treating void regions. A consistent diffusion scheme is developed with projection. Correction terms of the diffusion scheme are derived to reproduce the transport scalar flux. A source iteration that decouples the solution of all directions with both linear and nonlinear diffusion accelerations is developed and demonstrated. One-dimensional Fourier analysis is conducted to demonstrate the stability of the linear and nonlinear diffusion accelerations. Numerical results of these schemes are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Two-Dimensional Correlation Method for Polymer Analysis

Since its introduction by Noda in 1986 two-dimension correlation spectroscopy has been offering polymer scientists an opportunity to look more deeply into collected spectroscopic data. When the spectra are recorded in response to an external perturbation, it is possible to correlate the spectra and expand the information over a separate spectra axis allow for enhancement of spectral resolution, the ability to determine synchronous change, and a unique way to organize observed changes in the spectra into sequential order following a set of three simple rules. By organizing the 2D spectra into synchronous change plots and asynchronous change plots it is possible to correlate change between spectral regions and develop their temporal relationships to one another. With the introduction of moving-window correlation-spectroscopy by Thomas and Richardson in 2000, a method of binning and processing data, it became possible to directly correlate relationships generated in the spectra from the change in the perturbation variable. This method takes advantage of the added resolution of two-dimension spectroscopy and has been applied to study very week transitions found in polymer materials. Appling both of these techniques we are beginning to develop an understanding of how polymers decay under radiolytic aging, to develop a stronger understanding of changes in mechanical properties and the service capabilities of materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Report: Quantification of Uncertainty in Extreme Scale Computations (QUEST)

QUEST (\url{www.quest-scidac.org}) is a SciDAC Institute that is focused on uncertainty quantification (UQ) in large-scale scientific computations. Our goals are to (1) advance the state of the art in UQ mathematics, algorithms, and software; and (2) provide modeling, algorithmic, and general UQ expertise, together with software tools, to other SciDAC projects, thereby enabling and guiding a broad range of UQ activities in their respective contexts. QUEST is a collaboration among six institutions (Sandia National Laboratories, Los Alamos National Laboratory, the University of Southern California, Massachusetts Institute of Technology, the University of Texas at Austin, and Duke University) with a history of joint UQ research. Our vision encompasses all aspects of UQ in leadership-class computing. This includes the well-founded setup of UQ problems; characterization of the input space given available data/information; local and global sensitivity analysis; adaptive dimensionality and order reduction; forward and inverse propagation of uncertainty; handling of application code failures, missing data, and hardware/software fault tolerance; and model inadequacy, comparison, validation, selection, and averaging. The nature of the UQ problem requires the seamless combination of data, models, and information across this landscape in a manner that provides a self-consistent quantification of requisite uncertainties in predictions from computational models. Accordingly, our UQ methods and tools span an interdisciplinary space across applied math, information theory, and statistics. The MIT QUEST effort centers on statistical inference and methods for surrogate or reduced-order modeling. MIT personnel have been responsible for the development of adaptive sampling methods, methods for approximating computationally intensive models, and software for both forward uncertainty propagation and statistical inverse problems. A key software product of the MIT QUEST effort is the MIT Uncertainty Quantification library, called MUQ (\url{muq.mit.edu}).

97 MATHEMATICS AND COMPUTING↗

Materials Dynamics

The Materials Dynamics area of leadership focuses on understanding process-structure-properties-performance (PSPP) relationships for the extreme conditions of dynamic loading. This research encompasses controlled synthesis of materials to meet dynamic performance requirements and entails computational coupling across length and time scales for three-dimensional microstructure modeling. For this leadership area, we define dynamic loading as strain rates ≥ 10 3 /s and often, high pressures. A key grand challenge of this area is to predict and measure the evolution of microstructural phases, defect structures, and electronic structure under dynamic conditions while also measuring local temperature to understand transition states. Solving this challenge will require agile, multi-dimensional data analysis and interpretation capability.

36 MATERIALS SCIENCE↗

Poisson-response Tensor-on-Tensor Regression and Applications

We introduce Poisson-response tensor-on-tensor regression (PToTR), a novel regression framework designed to handle tensor responses composed element-wise of random Poisson-distributed counts. Tensors, or multi-dimensional arrays, composed of counts are common data in fields such as inter national relations, social networks, epidemiology, and medical imaging, where events occur across multiple dimensions like time, location, and dyads. PToTR accommodates such tensor responses alongside tensor covariates, providing a versatile tool for multi dimensional data analysis. We propose algorithms for maximum likelihood estimation under a canonical polyadic (CP) structure on the regression coefficient tensor that satisfy the positivity of Poisson parameters and then provide an initial theoretical error analysis for PToTR estimators. We also demonstrate the utility of PToTR through three concrete applications: longitudinal data analysis of the Integrated Crisis Early Warning System database, positron emission tomography (PET) image reconstruction, and change-point detection of communication patterns in longitudinal dyadic data. These applications highlight the versatility of PToTR in addressing complex, structured count data across various domains.

97 MATHEMATICS AND COMPUTING↗

A One-Dimensional Stack Model for Redox Flow Battery Analysis and Operation

Current redox flow battery (RFB) stack models are not particularly conducive to accurate yet high-throughput studies of stack operation and design. To facilitate system-level analysis, we have developed a one-dimensional RFB stack model through the combination of a one-dimensional Newman-type cell model and a resistor-network to evaluate contributions from shunt currents within the stack. Inclusion of hydraulic losses and membrane crossover enables constrained optimization of system performance and allows users to make recommendations for operating flow rate, current densities, and cell design given a subset of electrolyte and electrode properties. Over the range of experimental conditions explored, shunt current losses remain small, but mass-transfer losses quickly become prohibitive at high current densities. Attempting to offset mass-transfer losses with high flow rates reduces system efficiency due to the increase in pressure drop through the porous electrode. The development of this stack model application, along with the availability of the source MATLAB code, allows for facile approximation of the upper limits of performance with limited empiricism. This work primarily presents a readily adaptable tool to enable researchers to perform either front-end performance estimates based on fundamental material properties or to benchmark their experimental results.

Barton, John L. (ORCID:0000000225729127)↗