Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

In-vivo Raman microspectroscopy reveals differential nitrate concentration in different developmental zones in Arabidopsis roots

Abstract Background Nitrate (NO 3 − ) is one of the two major forms of inorganic nitrogen absorbed by plant roots, and the tissue nitrate concentration in roots is considered important for optimizing developmental programs. Technologies to quantify the expression levels of nitrate transporters and assimilating enzymes at the cellular level have improved drastically in the past decade. However, a technological gap remains for detecting nitrate at a high spatial resolution. Using extraction-based methods, it is challenging to reliably estimate nitrate concentration from a small volume of cells (i.e., with high spatial resolution), since targeting a small or specific group of cells is physically difficult. Alternatively, nitrate detection with microelectrodes offers subcellular resolution with high cell specificity, but this method has some limitations on cell accessibility and detection speed. Finally, optical nitrate biosensors have very good ( in-vivo ) sensitivity (below 1 mM) and cellular-level spatial resolution, but require plant transformation, limiting their applicability. In this work, we apply Raman microspectroscopy for high-dynamic range in-vivo mapping of nitrate in different developmental zones of Arabidopsis thaliana roots in-situ . Results As a proof of concept, we have used Raman microspectroscopy for in-vivo mapping of nitrate content in roots of Arabidopsis seedlings grown on agar media with different nitrate concentrations. Our results revealed that the root nitrate concentration increases gradually from the meristematic zone (~ 250 µm from the root cap) to the maturation zone (~ 3 mm from the root cap) in roots grown under typical growth conditions used for Arabidopsis, a trend that has not been previously reported. This trend was observed for plants grown in agar media with different nitrate concentrations (0.5–10 mM). These results were validated through destructive measurement of nitrate concentration. Conclusions We present a methodology based on Raman microspectroscopy for in-vivo label-free mapping of nitrate within small root tissue volumes in Arabidopsis. Measurements are done in-situ without additional sample preparation. Our measurements revealed nitrate concentration changes from lower to higher concentration from tip to mature root tissue. Accumulation of nitrate in the maturation zone tissue shows a saturation behavior. The presented Raman-based approach allows for in-situ non-destructive measurements of Raman-active compounds.

Fernández González, Alma↗

Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade

Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of pyrometry and thermography for thermal analysis of thermite reactions

This article examines the thermal behavior of a laser ignited thermite composed of aluminum and bismuth trioxide. Temperature data were collected during the reaction using a four-color pyrometer and a high-speed color camera modified for thermography. The two diagnostics were arranged to collect data simultaneously, with similar fields of view and with similar data acquisition rates, so that the two techniques could be directly compared. Results show that at initial and final stages of the reaction, a lower signal-to-noise ratio affects the accuracy of the measured temperatures. Both diagnostics captured the same trends in transient thermal behavior, but the average temperatures measured with thermography were about 750 K higher than those from the pyrometer. This difference was attributed to the lower dynamic range of the thermography camera’s image sensor, which was unable to resolve cooler temperatures in the field of view as well as the photomultiplier tube sensors in the pyrometer. Overall, while the camera could not accurately capture the average temperature of a scene, its ability to capture peak temperatures and spatial data make it the preferred method for tracking thermal behavior in thermite reactions.

36 MATERIALS SCIENCE↗

Paired circularly polarized heterodyne ellipsometer

We develop a paired circularly polarized heterodyne ellipsometer (PCPHE), in which a heterodyne interferometer based on a two-frequency circularly polarized laser beam is set up. It belongs to an amplitude-sensitive ellipsometer that is able to provide not only a wider dynamic range of polarization modulation frequency but also a higher detection sensitivity than that of a conventional photometric ellipsometer. A real-time and precise measurement of ellipsometric parameters, which demonstrated an accuracy of less than 1 nm on thickness measurement of SiO2 thin film deposited on silicon substrate, can be applied with the PCPHE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous analog and photon counting detection for Raman lidar

The Atmospheric Radiation Measurement program Raman Lidar was upgraded in 2004 with a new data system that provides simultaneous measurements of both the photomultiplier analog output voltage and photon counts. This paper describes recent improvements to the algorithm used to merge these two signals into a single signal with improved dynamic range. The impact of modifications to the algorithm are evaluated by comparing profiles of water vapor mixing ratio from the lidar with sonde measurements. The modifications that were implemented resulted in a reduction of the mean bias in the daytime mixing ratio from a 4% dry bias to well within 1%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Propagation-based phase-contrast enhancement of nanostructure images using a debris-free femtosecond-laser-driven cluster-based plasma soft x-ray source and an LiF crystal detector

We demonstrate in-line phase-contrast imaging of nanothickness foils by using a relatively large, polychromatic, debris-free femtosecond-laser-driven cluster-based plasma soft x-ray source, and a high-resolution, large dynamic range LiF crystal detector. The spatial coherence length of radiation in our setup reached a value of 5 {mu}m on the sample plane, which is enough to observe phase-contrast enhancement in the images registered by the detector placed only a few hundred micrometers behind the object. We have developed a tabletop soft x-ray emission source, which emits radiation within a 4{pi} sr solid angle, and which allows one to obtain contact and propagation-based phase-contrast imaging of nanostructures with 700 nm spatial resolutions. This advance could be of utility for metrology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incorrect support and missing center tolerances of phasing algorithms

In x-ray diffraction microscopy, iterative algorithms retrieve reciprocal space phase information, and a real space image, from an object's coherent diffraction intensities through the use of a priori information such as a finite support constraint. In many experiments, the object's shape or support is not well known, and the diffraction pattern is incompletely measured. We describe here computer simulations to look at the effects of both of these possible errors when using several common reconstruction algorithms. Overly tight object supports prevent successful convergence; however, we show that this can often be recognized through pathological behavior of the phase retrieval transfer function. Dynamic range limitations often make it difficult to record the central speckles of the diffraction pattern. We show that this leads to increasing artifacts in the image when the number of missing central speckles exceeds about 10, and that the removal of unconstrained modes from the reconstructed image is helpful only when the number of missing central speckles is less than about 50. In conclusion, this simulation study helps in judging the reconstructability of experimentally recorded coherent diffraction patterns.

36 MATERIALS SCIENCE↗

Frequency-domain terahertz spectroscopy using long-carrier-lifetime photoconductive antennas

We present a telecommunication-compatible frequency-domain terahertz spectroscopy system realized by novel photoconductive antennas without using short-carrier-lifetime photoconductors. Built on a high-mobility InGaAs photoactive layer, these photoconductive antennas are designed with plasmonics-enhanced contact electrodes to achieve highly confined optical generation near the metal/semiconductor surface, which offers ultrafast photocarrier transport and, hence, efficient continuous-wave terahertz operation including both generation and detection. Consequently, using two plasmonic photoconductive antennas as a terahertz source and a terahertz detector, we successfully demonstrate frequency-domain spectroscopy with a dynamic range more than 95 dB and an operation bandwidth of 2.5 THz. Moreover, this novel approach to terahertz antenna design opens up a wide range of new possibilities for many different semiconductors and optical excitation wavelengths to be utilized, therefore bypassing short-carrier-lifetime photoconductors with limited availability.

36 MATERIALS SCIENCE↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗

Distributed Brillouin fiber laser sensor

Brillouin fiber sensors can provide distributed strain and temperature measurements over long distances in standard off-the-shelf fiber by measuring the Brillouin frequency shift as a function of position along a fiber. The primary drawback of these systems is their limited sensitivity, which results from the challenge in identifying the Brillouin frequency shift to within a small fraction of the Brillouin linewidth. In this work, we introduce a technique that overcomes this fundamental limitation by establishing a series of lasing modes that experience Brillouin amplification at discrete spatial locations in the test fiber. The linewidth narrowing and high intensity associated with the lasing transition enable precise measurements of this lasing frequency. As an initial demonstration, we present a sensor that simultaneously excites 40 lasing modes in a 400 m fiber, providing a measurement of the strain at 40 discrete locations with a spatial resolution of 4 m. Each sensor exhibits a minimum detectable strain as low as 4 nε/Hz 1/2 with a dynamic range of >5 mε and a bandwidth of ~10 kHz. As the first demonstration that Brillouin lasing can be used for distributed fiber sensing, this work establishes an approach that could enable ultra-high strain sensitivity using off-the-shelf fiber.

47 OTHER INSTRUMENTATION↗

Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.

60 APPLIED LIFE SCIENCES↗

Mass spectrometry in biomarker applications: from untargeted discovery to targeted verification, and implications for platform convergence and clinical application

It is really only in the last ten years that mass spectrometry (MS) has had a truly significant (but still small) impact on biomedical research. Much of this impact can be attributed to proteomics and its more basic applications. Early biomedical applications have included a number of efforts aimed at developing new biomarkers; however, the success of these endeavors to date have been quite modest - essentially confined to preclinical applications - and have often suffered from combinations of immature technology and hubris. Now that MS-based proteomics is reaching adolescence, it is appropriate to ask if and when biomarker-related applications will extend to the clinical realm, and what developments will be essential for this transition. Biomarker development can be described as a multistage process consisting of discovery, qualification, verification, research assay optimization, validation, and commercialization (1). From a MS perspective, it is possible to 'bin' measurements into 1 of 2 categories - those aimed at discovering potential protein biomarkers and those seeking to verify and validate biomarkers. Approaches in both categories generally involve digesting proteins (e.g., with trypsin) as a first step to yield peptides that can be effectively detected and identified with MS. Discovery-based approaches use broad 'unbiased' or 'undirected' measurements that attempt to cover as many proteins as possible in the hope of revealing promising biomarker candidates. A key challenge with this approach stems from the extremely large dynamic range (i.e., relative stoichiometry) of proteins of potential interest in biofluids such as plasma and the expectation that biomarker proteins of the greatest clinical value for many diseases may very well be present at low relative abundances (2). Protein concentrations in plasma extend from approximately 10{sup 10} pg/mL for albumin to approximately 10 pg/mL and below for interleukins and other cytokines.

59 BASIC BIOLOGICAL SCIENCES↗

Temporal and spatial tuning of optical constants in praseodymium doped ceria by electrochemical means

Abstract Temporal and spatial tuning of the refractive index of optical thin films is desired for flat optics applications. The redistribution of mobile ions in mixed ionic-electronic conductors (MIEC) has been demonstrated to serve as a viable means for achieving optical tuning down to the nanoscale. Here we studied the dynamic range of the optical tuning achievable in the refractive index, in the MIEC oxide – Pr x Ce 1− x O 2− δ (PCO), for x = 0.1, 0.2 and 0.4, at 500 °C, by in-situ spectrophotometry. Significant increases in the modulation of both the imaginary and real optical constants in the visible and the adjacent spectra were obtained for increased doping levels. Device employing an electrochemical titration method was implemented to modulate the oxygen concentration, and thereby the optical transmission of PCO. Incorporation of a patterned top electrode allowed for the demonstration of spatial control of PCO thin film properties by in-situ video imaging of the optical switching process. The electrochemically induced optical state is shown to remain non-volatile upon quenching the device to room temperature under applied bias.

36 MATERIALS SCIENCE↗

Extraction of the electron excess temperature in terahertz quantum cascade lasers from laser characteristics

Abstract We propose a method to extract the upper laser level’s (ULL’s) excess electronic temperature from the analysis of the maximum light output power ( P max ) and current dynamic range Δ J d = ( J max − J th ) of terahertz quantum cascade lasers (THz QCLs). We validated this method, both through simulation and experiment, by applying it on THz QCLs supporting a clean three-level system. Detailed knowledge of electronic excess temperatures is of utmost importance in order to achieve high temperature performance of THz QCLs. Our method is simple and can be easily implemented, meaning an extraction of the excess electron temperature can be achieved without intensive experimental effort. This knowledge should pave the way toward improvement of the temperature performance of THz QCLs beyond the state-of-the-art.

47 OTHER INSTRUMENTATION↗

High pH reversed-phase chromatography with fraction concatenation for 2D proteomic analysis

Orthogonal high-resolution separations are critical for attaining improved analytical dynamic ranges of proteome measurements. Concatenated high pH reversed phase liquid chromatography affords better separations than the strong cation exchange conventionally applied for two-dimensional shotgun proteomic analysis. For example, concatenated high pH reversed phase liquid chromatography increased identification coverage for peptides (e.g., by 1.8-fold) and proteins (e.g., by 1.6-fold) in shotgun proteomics analyses of a digested human protein sample. Additional advantages of concatenated high pH RPLC include improved protein sequence coverage, simplified sample processing, and reduced sample losses, making this an attractive first dimension separation strategy for two-dimensional proteomics analyses.

59 BASIC BIOLOGICAL SCIENCES↗

Fiber-Optic Sensing for Earthquake Hazards Research, Monitoring, and Early Warning

The use of fiber‐optic sensing systems in seismology has exploded in the past decade. Despite an ever‐growing library of ground‐breaking studies, questions remain about the potential of fiber‐optic sensing technologies as tools for advancing if not revolutionizing earthquake‐hazards‐related research, monitoring, and early warning systems. A working group convened to explore these topics; we comprehensively examined the application of fiber optics in various aspects of earthquake hazards, encompassing earthquake source processes, crustal imaging, data archiving, and technological challenges. There is great potential for fiber‐optic systems to advance earthquake monitoring and understanding, but to fully unlock their capabilities requires continued progress in key areas of research and development, including instrument testing and validation, increased dynamic range for applications focused on larger earthquakes, and continued improvement in subsurface and source imaging methods. A key current stumbling block results from the lack of clear data archiving requirements, and we propose an initial strategy that balances data volume requirements with preserving key data for a broad range of future studies. In addition, we demonstrate the potential for fiber‐optic sensing to impact monitoring efforts by documenting the data completeness in a number of long‐term experiments. Finally, we outline the features of a instrument testing facility that would enable progress toward reliable and standardized distributed acoustic sensing data. Overcoming these current obstacles would facilitate progress in fiber‐optic sensing and unlock its potential application to a broad range of earthquake hazard problems.

58 GEOSCIENCES↗

Synchrotron Radiation Beam Diagnostics at IOTA - Commissioning Performance and Upgrade Efforts

The Integrable Optics Test Accelerator is a research electron and proton storage ring recently commissioned at the Fermilab Accelerator Science and Technology facility. A key part of its beam diagnostics suite are synchrotron radiation monitors, used for measuring transverse beam profile, position, and intensity. In this paper, we report on the performance and uses of this system during the year 1 run. We demonstrate sub-100nm statistical beam position uncertainty and high dynamic range from 10⁹ electrons down to a single electron. Commissioning challenges and operational issues are discussed. We conclude by outlining current upgrade efforts, including improved modularity, small emittance measurements, and a multi-anode photomultiplier system for turn-by-turn acquisition.

43 PARTICLE ACCELERATORS↗