Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Dynamic Leaching Method for Intact Salt-stone Samples - 18495

At the Savannah River Site (SRS) low activity salt solution is stabilized via encapsulation within a grout termed salt-stone. Salt-stone is emplaced into large (multi-million liter) concrete storage containers referred to as Salt-stone Disposal Units (SDUs). Technetium-99 (Tc-99) and iodine-129 (I-129) are long-lived radionuclides contained in the low activity salt waste and subsequently incorporated into the grout waste form: both radionuclides are contributors to the potential long-term radiation exposure of the public and environment surrounding the SDUs. With respect to Tc-99, in the reducing, high pH environment within the grout, Tc-99 is expected to be relatively immobile since it exists in a reduced Tc(IV) oxidation state in the form of sparingly soluble hydrated oxides (TcO{sub 2}.xH{sub 2}O) or sulfides (TcS{sub x}). However, in the presence of O{sub 2} (associated with the future infiltration of air or oxygenated ground waters into the salt-stone monolith) it is possible for redox-sensitive Tc(IV) to transition into highly soluble (and mobile) Tc(VII) species, such as pertechnetate (TcO{sub 4}{sup -}), which are more readily transported to the surrounding environment. In contrast, I-129 is highly soluble and its leaching behavior is not anticipated to be significantly impacted by potential changes in redox environment or pH within salt-stone. Traditional approaches to quantifying the leaching behavior of Tc-99 and I-29 from cementitious matrices have involved partitioning experiments using size-reduced (crushed/ground) samples, and determination of the radionuclide fraction immobilized by the cementitious solids. Such experiments create artificially high solid-liquid contact areas that likely result in higher Tc-99 and I-129 leachate concentrations than would be expected for intact, monolithic samples. In the current study a new technique, termed the Dynamic Leaching Method (DLM), is being used to initially investigate the Tc-99 leaching behavior from monolithic salt-stone samples; the system will be used at a later date to evaluate the leaching characteristics of I-129. The data derived using this technique is intended to inform the SRS Salt-stone Disposal Facility (SDF) Performance Assessment (PA) which models the long-term transport of radionuclides from the SDUs to the environment. The DLM utilizes a flexible-wall permeameter to achieve saturated leaching under an elevated hydraulic gradient to simulate and accelerate the future transport of groundwater through salt-stone. Leachates are regularly analyzed with respect to radionuclide concentrations, key constituent concentrations (e.g., Al, Ca, Mg, Na, Si, CO{sub 3}{sup 2-}, NO{sub 2}{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup 2-}), pH, and reduction potential (E{sub h}) in order to develop an understanding of how chemical changes associated with the pore solution influence grout weathering and radionuclide leaching behavior. This paper provides a brief update with respect to data derived from preliminary Tc-99 leaching evaluations as the DLM was being developed, but the paper is predominantly focused on new sample data in which the DLM technique, pre- and post-DLM salt-stone sample characterization, and leachate analysis protocols have been optimized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI

Objective: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Methods: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ({sup 13}N-NH{sub 3}: 813 ± 86 MBq) and metabolism ({sup 18}F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Results: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Conclusion: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-Depth Analysis of Subject Functional Performance and Subjective Feedback Data for Evaluating Argos Simulation Quality

Mechanical offloading systems such as the Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) are used to simulate various partial gravity environments. ARGOS offloads pressurized suited subjects through a gimbaling pivot point system attached to a volumetric Portable Life Support System (PLSS). The pivot point can be configured to multiple locations with respect to the human-suit system center of gravity (CG). Previous work has tested and documented the interaction between different pivot point locations and measured CG. Observations indicated that small changes in pivot point location substantially affect the stability and functional performance (simulation quality) of a subject. This led to the development of a standardized gimbal assessment protocol to assess the functional performance of a pressurized suited subject as a function of the pivot point location, using the data obtained from a variety of planetary suit mobility tasks. As a result, an expansive repository of CG-related task metrics was generated from numerous ARGOS spacesuit test events, for different gimbal configurations and different test subjects. Based on the evaluation metrics and observed trends, several pivot point locations were iteratively identified to determine an “appropriate/optimal” configuration. This study thus describes the in-depth analysis of the CG evaluation metrics to better quantify trends and determine if specific factors are strongly associated with appropriate/optimal configurations. Quantitative and qualitative variables relating to subject task performance, subjective feedback, and anthropometry will be evaluated via probabilistic methods. The results from this study are expected to improve our understanding of optimal ARGOS gimbal settings, which will better inform the gimbal configuration identification process and improve simulation quality for extravehicular activity (EVA) training.

Joseph Yao↗

Chemoradiation With Paclitaxel and Carboplatin in High-Risk Cervical Cancer Patients After Radical Hysterectomy: A Korean Gynecologic Oncology Group Study

Purpose: To evaluate the efficacy and toxicity of concurrent chemoradiation with paclitaxel and carboplatin in patients with high-risk cervical cancer. Methods and Materials: Patients after radical hysterectomy for cervical cancer, with at least 1 high-risk characteristic, were administered paclitaxel 135 mg/m{sup 2}, carboplatin area under the curve = 5 every 3 weeks for 3 cycles concomitant with radiation therapy as adjuvant treatment. Results: This prospective study enrolled 71 consecutive patients. Sixty-six patients (93%) completed the planned treatment. The majority of grade 3/4 neutropenia or nonhematologic toxicities were usually self-limited. Diarrhea grades 3/4 were observed in 4 patients (5.6%). One patient developed anaphylactic shock after infusion of paclitaxel. With a median follow-up of 57 months, recurrences occurred in 16 patients. Multivariable analysis indicated that common iliac lymph node involvement is an independent risk factor for disease recurrence (odds ratio 13.48; 95% confidence interval 2.93-62.03). In the intent-to-treat population (n=71), the estimated 5-year disease-free survival and overall survival rates were 77.3% and 80.3% respectively. In the per-protocol population (n=62), disease-free survival was 78.9% and overall survival was 83.9%. Conclusions: Concurrent chemoradiation with paclitaxel/carboplatin is well tolerated and seems to be effective for patients who undergo radical hysterectomy. Therefore, a prospective, randomized controlled study should be designed to evaluate efficacy of this approach for patients with high-risk cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating Physiological Response with a Passive Sensor Manikin and an Adaptive Thermal Manikin to Predict Thermal Sensation and Comfort

Reliable assessment of occupant thermal comfort can be difficult to obtain within automotive environments, especially under transient and asymmetric heating and cooling scenarios. Evaluation of HVAC system performance in terms of comfort commonly requires human subject testing, which may involve multiple repetitions, as well as multiple test subjects. Instrumentation (typically comprised of an array of temperature sensors) is usually only sparsely applied across the human body, significantly reducing the spatial resolution of available test data. Further, since comfort is highly subjective in nature, a single test protocol can yield a wide variation in results which can only be overcome by increasing the number of test replications and subjects. In light of these difficulties, various types of manikins are finding use in automotive testing scenarios. These manikins can act as human surrogates from which local skin and core temperatures can be obtained, which are necessary for accurately predicting local and whole body thermal sensation and comfort using a physiology-based comfort model (e.g., the Berkeley Comfort Model). This paper evaluates two different types of manikins, i) an adaptive sweating thermal manikin, which is coupled with a human thermoregulation model, running in real-time, to obtain realistic skin temperatures; and, ii) a passive sensor manikin, which is used to measure boundary conditions as they would act on a human, from which skin and core temperatures can be predicted using a thermophysiological model. The simulated physiological responses and comfort obtained from both of these manikin-model coupling schemes are compared to those of a human subject within a vehicle cabin compartment transient heat-up scenario.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Automated Software Program for the Analysis of Alzheimer's Disease Scans: Evaluation of PET imaging with PBR-111 in HV and AD subjects

Study goal: A Phase 1 evaluation of the kinetics, clearance and cerebral distribution of one novel peripheral benzodiazepine receptors(PBR)positron emission tomography (PET) imaging agent, 18F-PBR-111 following intravenous administration in healthy volunteers and Alzheimer's disease (AD) patients. Short title: Evaluation of PET imaging with PBR-111 in HV and AD subjects Proof of Mechanism. Primary Objective: To evaluate the cerebral distribution of PBR-111 positron emission tomography (PET) for detection/exclusion of microglial activation in patients with Alzheimer's disease subjects compared to healthy volunteers. Secondary objectives: - To assess the dynamic uptake and washout of [18F]PBR-111, a potential imaging bio-marker for inflammatory changes in brain, using positron emission tomography in subjects with Alzheimer's disease (AD) and healthy volunteers (HV). - To perform blood metabolite characterization of [18F]PBR-111 in subjects with AD and HV to determine the nature of metabolites in assessment of [18F]-PBR-111 as a PET brain imaging agent. Name of radioactive drug substance: PBR-111 Dose(s): The applied PBR-111 radioactive dose will be up to 5.0 mCi, diluted in a maximum of 10 ml of saline. The radioligand will be administered as a slow intravenous bolus injection (i.e., 6 sec/ml) into a large vein (e.g., antecubital vein). Route of administration: Intravenous injection Duration of treatment: Single administration of a diagnostic agent Indication: PBR-111 positron emission tomography (PET) imaging has the potential to detect microglial activation. In the presence of PBR-111 uptake (representative of microglial activation), inflammation in the brain can be detected. Diagnosis and main criteria for inclusion: Study participants will be HVs and patients diagnosed with probable AD. HVs must be 18 years of age (at least four subjects 50 years of age) and have no evidence of cognitive impairment or other neurologic disease by medical history. The lack of cognitive impairment will also be based on a Clinical Dementia Rating (CDR) of 0. Patients with probable AD must be 50 years of age and must fulfill the National Institute of Neurological and Communicative Disorders and Stroke, Alzheimer's Disease and Related Disorders Association [NINCDS-ADRDA] criteria for probable AD. The CDR score must be 1.0 and 2.0 and have a modified Hachinski of 4. All HVs and all patients with probable AD must be able to comply with all study procedures. Study design: This is a Phase 1, open-label, single-center, non-randomized single dose study to assess the kinetics, clearance and cerebral distribution of PBR-111 PET imaging in detecting microglial activation in the brain in patients with probable AD compared to HVs. All aspects related to image acquisition, processing, and visual as well as quantitative evaluation will be developed, optimized, and validated (where required). Each subject will be required to visit the study center during the screening phase and on the PBR-111 PET imaging day (baseline). A telephone follow-up visit will be performed 7 days (± 3 days) after PBR-111 PET administration. At the screening visit, each subject (or caregiver in the case of AD subjects) will be asked to provide written informed consent or assent. During the screening phase (maximum duration of 60 days) subject medical, neurological, and surgical history, clinical assessments, and a neuro-psychiatric evaluation will be performed on all eligible subjects. Subjects will be allowed to leave the center after all evaluations have been completed. During this period an MRI of the brain will be performed during the screening period. If an MRI of the brain has been performed within six months of the imaging visit using the methods described in the protocol, and there has been no medically significant events in the interim, the previous MRI may be used. During the PBR-111 PET imaging day, all subjects will receive a single intravenous injection of PBR-111 and scanning will be performed over a 3.5 hour period. Each subject will have a telephone follow-up 7 days (± 3 days) thereafter to assess for adverse events. Methodology: - Assessments to provide clinical characterization of the AD subjects will be performed. - After administration of PBR-111, images will be generated with state-of-the-art PET imaging. Images will be assessed quantitatively for the presence of microglial activation by a nuclear physician blinded to clinical data. - Total radioactivity and estimation of the fraction of radioactivity associated to the un-metabolized tracer will be determined. In addition, the metabolite patterns of PBR-111 are determined in venous plasma and arterial samples based on high-performance liquid chromatography (HPLC) analyses. - Arterial sampling will be acquired in the initial two AD and two HV subjects and modeling will be assessed to determine if additional arterial sampling is necessary.

97 MATHEMATICS AND COMPUTING↗

SU-E-I-33: Initial Evaluation of Model-Based Iterative CT Reconstruction Using Standard Image Quality Phantoms

Purpose: The purpose of this study was to compare a new model-based iterative reconstruction with existing reconstruction methods (filtered backprojection and basic iterative reconstruction) using quantitative analysis of standard image quality phantom images. Methods: An ACR accreditation phantom (Gammex 464) and a CATPHAN600 phantom were scanned using 3 routine clinical acquisition protocols (adult axial brain, adult abdomen, and pediatric abdomen) on a Philips iCT system. Each scan was acquired using default conditions and 75%, 50% and 25% dose levels. Images were reconstructed using standard filtered backprojection (FBP), conventional iterative reconstruction (iDose4) and a prototype model-based iterative reconstruction (IMR). Phantom measurements included CT number accuracy, contrast to noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD), and noise power spectrum (NPS). Results: The choice of reconstruction method had no effect on CT number accuracy, or MTF (p<0.01). The CNR of a 6 HU contrast target was improved by 1–67% with iDose4 relative to FBP, while IMR improved CNR by 145–367% across all protocols and dose levels. Within each scan protocol, the CNR improvement from IMR vs FBP showed a general trend of greater improvement at lower dose levels. NPS magnitude was greatest for FBP and lowest for IMR. The NPS of the IMR reconstruction showed a pronounced decrease with increasing spatial frequency, consistent with the unusual noise texture seen in IMR images. Conclusion: Iterative Model Reconstruction reduces noise and improves contrast-to-noise ratio without sacrificing spatial resolution in CT phantom images. This offers the possibility of radiation dose reduction and improved low contrast detectability compared with filtered backprojection or conventional iterative reconstruction.

60 APPLIED LIFE SCIENCES↗

Examining the Effects of Chronic Selenium Exposure on Traditionally Used Stress Parameters in Juvenile American Alligators ( Alligator mississippiensis )

Environmental contaminants, such as the trace element selenium (Se), are a continuing concern to species worldwide due to their potential pathophysiological effects, including their influence on the stress response mediated through glucocorticoids (GCs; stress hormones). Environmental concentrations of Se are increasing due to anthropogenic activities, including the incomplete combustion of coal and subsequent disposal of coal combustion wastes. However, most studies examining how Se affects GCs have been focused on lower trophic organisms. The objectives of this study were to investigate the effects of long-term Se exposure on traditionally used stress parameters and to identify which of these parameters best indicate Se accumulation in liver and kidney of the American alligator (Alligator mississippiensis), a top trophic carnivore found in the southeastern United States and known to inhabit Se-containing areas. Alligators were divided into three dietary treatments and fed prey spiked with 1000 or 2000 ppm selenomethionine (SeMet) or deionized water (control treatment) for 7 weeks. Following the 7-week treatment protocol, blood and tissue samples were obtained to measure plasma corticosterone (CORT; the main crocodilian GC), tail scute CORT, the ratio of peripheral blood heterophils (H) to lymphocytes (L) as H/L ratio, and body condition. To evaluate which parameter best indicated Se accumulation in the liver and kidney, principal component and discriminant analyses were performed. The only parameter significantly correlated with liver and kidney Se concentrations was scute CORT. Furthermore, our results suggest that measurement of CORT in tail scutes, when compared to plasma CORT, H/L ratios, and body condition, is the best indicator of Se-exposure and accumulation in crocodilians.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Frequency-Domain Intravascular Optical Coherence Tomography of the Femoropopliteal Artery

Purpose: Optical coherence tomography (OCT) is a catheter-based imaging method that employs near-infrared light to produce high-resolution intravascular images. The authors report the safety and feasibility and illustrate common imaging findings of frequency-domain OCT (FD-OCT) imaging of the femoropopliteal artery in a series of 20 patients who underwent infrainguinal angioplasty. Methods: After crossing the lesion of interest, OCT was performed with a dextrose saline flush technique with simultaneous obstructive manual groin compression. An automatic pullback FD-OCT device was employed (each scan acquiring 54 mm of vessel lumen in 271 consecutive frames). OCT images were acquired before and after balloon dilatation and following provisional stenting if necessary and were evaluated for baseline characteristics of plaque or in-stent restenosis (ISR), vessel wall trauma after angioplasty, presence of thrombus, stent apposition, and tissue prolapse. Imaging follow-up was not included in this study's protocol. Results: Twenty-seven obstructive lesions (18 cases of de novo atherosclerosis and 9 of ISR) of the femoropopliteal artery were imaged and 148 acquisitions were analyzed in total. High-resolution intravascular OCT imaging with effective blood clearance was achieved in 93.9%. Failure was mainly attributed to preocclusive proximal lesions and/or collateral flow. Mixed features of lipid pool areas, calcium deposits, necrotic core, and fibrosis were identified in all of the imaged atherosclerotic lesions, whereas ISR was purely fibrotic. After balloon angioplasty, OCT identified extensive intimal tears in all cases and one case of severe dissection that biplane subtraction angiography failed to identify. Conclusions: Infrainguinal frequency-domain optical coherence tomography is safe and feasible and may provide intravascular high-resolution imaging of the femoropopliteal artery during infrainguinal angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How well do terrestrial biosphere models simulate coarse-scale runoff in the contiguous United States?

Significant changes in the water cycle are expected under current global environmental change. Robust assessment of present-day water cycle dynamics at continental to global scales is confounded by shortcomings in the observed record. Modeled assessments also yield conflicting results which are linked to differences in model structure and simulation protocol. Here we compare simulated gridded (1 spatial resolution) runoff from six terrestrial biosphere models (TBMs), seven reanalysis products, and one gridded surface station product in the contiguous United States (CONUS) from 2001 to 2005. We evaluate the consistency of these 14 estimates with stream gauge data, both as depleted flow and corrected for net withdrawals (2005 only), at the CONUS and water resource region scale, as well as examining similarity across TBMs and reanalysis products at the grid cell scale. Mean runoff across all simulated products and regions varies widely (range: 71 to 356 mm yr(-1)) relative to observed continental-scale runoff (209 or 280 mm yr(-1) when corrected for net withdrawals). Across all 14 products 8 exhibit Nash-Sutcliffe efficiency values in excess of 0.8 and three are within 10% of the observed value. Region-level mismatch exhibits a weak pattern of overestimation in western and underestimation in eastern regions although two products are systematically biased across all regions and largely scales with water use. Although gridded composite TBM and reanalysis runoff show some regional similarities, individual product values are highly variable. At the coarse scales used here we find that progress in better constraining simulated runoff requires standardized forcing data and the explicit incorporation of human effects (e.g., water withdrawals by source, fire, and land use change). (C) 2015 Elsevier B.V. All rights reserved.

54 ENVIRONMENTAL SCIENCES↗

Consistent production of chlorine-stressed bacteria from non-chlorinated secondary sewage effluents for use in the U.S. Environmental Protection Agency Alternate Test Procedure protocol

The U.S. Environmental Protection Agency Alternative Test Procedure protocol outlines a method to produce chlorine-stressed bacteria for water quality testing. Achieving consistent results is challenging due effluent variability. We describe methods for generating chlorine-stressed total coliforms from secondary effluent to evaluate detection technologies to demonstrate comparability to EPA reference methods

59 BASIC BIOLOGICAL SCIENCES↗

Electric field stimulated growth of Zn whiskers

We have investigated the impact of strong (∼10{sup 4} V/cm) electric fields on the development of Zn whiskers. The original samples, with considerable whisker infestation were cut from Zn-coated steel floors and then exposed to electric fields stresses for 10-20 hours at room temperature. We used various electric field sources, from charges accumulated in samples irradiated by: (1) the electron beam of a scanning electron microscope (SEM), (2) the electron beam of a medical linear accelerator, and (3) the ion beam of a linear accelerator; we also used (4) the electric field produced by a Van der Graaf generator. In all cases, the exposed samples exhibited a considerable (tens of percent) increase in whiskers concentration compared to the control sample. The acceleration factor defined as the ratio of the measured whisker growth rate over that in zero field, was estimated to approach several hundred. The statistics of lengths of e-beam induced whiskers was found to follow the log-normal distribution known previously for metal whiskers. The observed accelerated whisker growth is attributed to electrostatic effects. These results offer promise for establishing whisker-related accelerated life testing protocols.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel and/or related reactor fuel designs and constituency will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data includes, but is not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data includes, but is not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data includes, but is not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗