Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

A study of differentiation errors in large-eddy simulations based on the EDQNM theory

This paper is concerned with the investigation of numerical errors in large-eddy simulations by means of two-point turbulence modeling. Based on the eddy-damped quasi-normal Markovian (EDQNM) theory, a stochastic model is developed in order to predict the time evolution of the kinetic energy spectrum obtained by a large-eddy simulation (LES), including the effects of the numerics. Using this framework, the influence of the accuracy of the approximate space differencing schemes on LES quality is studied, for decaying homogeneous isotropic incompressible turbulence, with Reynolds numbers Re{sub {lambda}} based on the transverse Taylor scale equal to 780, 2500 and 8000. The results show that the discretization of the filtered Navier-Stokes equations leads to differentiation and aliasing errors. Error spectra are also presented, and indicate that the numerical errors are mainly originating from the approximate differentiation. In addition, increasing the order of accuracy of the differencing schemes or using algorithms optimized in the Fourier space is found to widen the range of well-resolved scales. Unfortunately, for all the schemes, the smaller scales with wavenumbers close to the grid cut-off wavenumber, are badly calculated and generate differentiation errors over the whole energy spectrum. The eventual use of explicit filtering to remove spurious motions with short wavelength is finally shown to significantly improve LES accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Principled halftoning based on human vision models

When models of human vision adequately measure the relative quality of candidate halftonings of an image, the problem of halftoning the image becomes equivalent to the search problem of finding a halftone that optimizes the quality metric. Because of the vast number of possible halftones, and the complexity of image quality measures, this principled approach has usually been put aside in favor of fast algorithms that seem to perform well. We find that the principled approach can lead to a range of useful halftoning algorithms, as we trade off speed for quality by varying the complexity of the quality measure and the thoroughness of the search. High quality halftones can be obtained reasonably quickly, for example, by using as a measure the vector length of the error image filtered by a contrast sensitivity function, and, as the search procedure, the sequential adjustment of individual pixels to improve the quality measure. If computational resources permit, simulated annealing can find nearly optimal solutions.

Mulligan, Jeffrey B.↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Actuation of atomic force microscopy microcantilevers using contact acoustic nonlinearities

A new method of actuating atomic force microscopy (AFM) cantilevers is proposed in which a high frequency (>5 MHz) wave modulated by a lower frequency (∼300 kHz) wave passes through a contact acoustic nonlinearity at the contact interface between the actuator and the cantilever chip. The nonlinearity converts the high frequency, modulated signal to a low frequency drive signal suitable for actuation of tapping-mode AFM probes. The higher harmonic content of this signal is filtered out mechanically by the cantilever transfer function, providing for clean output. A custom probe holder was designed and constructed using rapid prototyping technologies and off-the-shelf components and was interfaced with an Asylum Research MFP-3D AFM, which was then used to evaluate the performance characteristics with respect to standard hardware and linear actuation techniques. Using a carrier frequency of 14.19 MHz, it was observed that the cantilever output was cleaner with this actuation technique and added no significant noise to the system. This setup, without any optimization, was determined to have an actuation bandwidth on the order of 10 MHz, suitable for high speed imaging applications. Using this method, an image was taken that demonstrates the viability of the technique and is compared favorably to images taken with a standard AFM setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Knot Selection for Least-squares Fitting of Noisy Data with Spline Functions

An automatic data-smoothing algorithm for data from digital oscilloscopes is described. The algorithm adjusts the bandwidth of the filtering as a function of time to provide minimum mean squared error at each time. It produces an estimate of the root-mean-square error as a function of time and does so without any statistical assumptions about the unknown signal. The algorithm is based on least-squares fitting to the data of cubic spline functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Arc Delivery for Stereotactic Body Radiotherapy of Vertebral and Lung Tumors

Purpose: Flattening filter-free (FFF) beams with higher dose rates and faster delivery are now clinically available. The purpose of this planning study was to compare optimized non-FFF and FFF RapidArc plans for stereotactic body radiotherapy (SBRT) and to validate the accuracy of fast arc delivery. Methods and Material: Ten patients with peripheral lung tumors and 10 with vertebral metastases were planned using RapidArc with a flattened 6-MV photon beam and a 10-MV FFF beam for fraction doses of 7.5-18 Gy. Dosimetry of the target and organs at risk (OAR), number of monitor units (MU), and beam delivery times were assessed. GafChromic EBT2 film measurements of FFF plans were performed to compare calculated and delivered dose distributions. Results: No major dosimetric differences were seen between the two delivery techniques. For lung SBRT plans, conformity indices and OAR doses were similar, although the average MU required were higher with FFF plans. For vertebral SBRT, FFF plans provided comparable PTV coverage, with no significant differences in OAR doses. Average beam delivery times were reduced by a factor of up to 2.5, with all FFF fractions deliverable within 4 min. Measured FFF plans showed high agreement with calculated plans, with more than 99% of the area within the region of interest fulfilling the acceptance criterion. Conclusion: The higher dose rate of FFF RapidArc reduces delivery times significantly, without compromising plan quality or accuracy of dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of eccentricity on searches for gravitational waves from coalescing compact binaries in ground-based detectors

Inspiralling compact binaries are expected to circularize before their gravitational-wave signals reach the sensitive frequency band of ground-based detectors. Current searches for gravitational waves from compact binaries using the LIGO and Virgo detectors therefore use circular templates to construct matched filters. Binary formation models have been proposed which suggest that some systems detectable by the LIGO-Virgo network may have non-negligible eccentricity. We investigate the ability of the restricted 3.5 post-Newtonian order TaylorF2 template bank, used by LIGO and Virgo to search for gravitational waves from compact binaries with masses M{<=}35M{sub {center_dot},} to detect binaries with nonzero eccentricity. We model the gravitational waves from eccentric binaries using the x-model post-Newtonian formalism proposed by Hinder et al.[I. Hinder, F. Hermann, P. Laguna, and D. Shoemaker, arXiv:0806.1037v1]. We find that small residual eccentricities (e{sub 0} < or approx. 0.05 at 40 Hz) do not significantly affect the ability of current LIGO searches to detect gravitational waves from coalescing compact binaries with total mass 2M{sub {center_dot}<}M<15M{sub {center_dot}.} For eccentricities e{sub 0} > or approx. 0.1, the loss in matched filter signal-to-noise ratio due to eccentricity can be significant and so templates which include eccentric effects will be required to perform optimal searches for such systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techniques to improve the accuracy of noise power spectrum measurements in digital x-ray imaging based on background trends removal

Purpose: Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems. Methods: In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression. Results: Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system. Conclusions: As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

Analysis of signal to noise enhancement using a highly selective modulation tracking filter

Experiments are reported which utilize photodielectric effects in semiconductor loaded superconducting resonant circuits for suppressing noise in RF communication systems. The superconducting tunable cavity acts as a narrow band tracking filter for detecting conventional RF signals. Analytical techniques were developed which lead to prediction of signal-to-noise improvements. Progress is reported in optimization of the experimental variables. These include improved Q, new semiconductors, improved optics, and simplification of the electronics. Information bearing signals were passed through the system, and noise was introduced into the computer model.

Haden, C. R.↗

Reduced-dynamic technique for precise orbit determination of low earth satellites

A reduced-dynamic technique for precise orbit determination of low earth satellites is described. This technique optimally combines the conventional dynamic technique with the nondynamic technique which uses differential GPS continuous carrier phase to define the state transition. A Kalman filter formulation for this reduced-dynamic technique is given. A covariance analysis shows that when neither the dynamic nor the nondynamic technique is clearly superior, the reduced-dynamic technique appreciably improves the orbit accuracy. Guidelines for selecting a near-optimum weighting for the combination are given. Sensitivity to suboptimal weighting is assessed.

Wu, Sien-Chong↗

3-D Surface Depression Profiling Using High Frequency Focused Air-Coupled Ultrasonic Pulses

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. This article shows quantitative surface topography profiles as obtained using only high-frequency focused air-coupled ultrasonic pulses. The profiles were obtained using a profiling system developed by NASA Glenn Research Center and Sonix, Inc (via a formal cooperative agreement). (The air transducers are available as off-the-shelf items from several companies.) The method is simple and reproducible because it relies mainly on knowledge and constancy of the sound velocity through the air. The air transducer is scanned across the surface and sends pulses to the sample surface where they are reflected back from the surface along the same path as the incident wave. Time-of-flight images of the sample surface are acquired and converted to depth/surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in air (V). The system has the ability to resolve surface depression variations as small as 25 microns, is useable over a 1.4 mm vertical depth range, and can profile large areas only limited by the scan limits of the particular ultrasonic system. (Best-case depth resolution is 0.25 microns which may be achievable with improved isolation from vibration and air currents.) The method using an optimized configuration is reasonably rapid and has all quantitative analysis facilities on-line including 2-D and 3-D visualization capability, extreme value filtering (for faulty data), and leveling capability. Air-coupled surface profilometry is applicable to plate-like and curved samples. In this article, results are shown for several proof-of-concept samples, plastic samples burned in microgravity on the STS-54 space shuttle mission, and a partially-coated cylindrical ceramic composite sample. Impressive results were obtained for all samples when compared with diamond-tip profiles and measurements from micrometers. The method is completely nondestructive, noninvasive, non-contact and does not require light-reflective surfaces.

Roth, Don J.↗

The Short-Term Prediction of Universal Time and Length-Of-Day Using Atmospheric Angular Momemtum

Methods to combine the diverse set of geodetic measurements of Earth orientation that are currently available, and to interpolate and extrapolate these data to generate an optimal estimate of Earth orientation, have been under development at JPL for a number of years. The strategy currently in use is a Kalman filtering scheme based on Earth orentation parameters and their excitation functions that incorporates stochastic models of the important physical processes and takes into account the variable form, quality, and temporal density of the data provided by diffent measurement services.

Universal Time↗

Methodology and Results of the Near-Earth Object (NEO) Human Space Flight (HSF) Accessible Targets Study (NHATS)

Near-Earth Asteroids (NEAs) have been identified by the current administration as potential destinations for human explorers during the mid-2020s. While the close proximity of these objects' orbits to Earth's orbit creates a risk of highly damaging or catastrophic impacts, it also makes some of these objects particularly accessible to spacecraft departing Earth, and this presents unique opportunities for solar system science and humanity's first ventures beyond cislunar space. Planning such ambitious missions first requires the selection of potentially accessible targets from the growing population of nearly 7,800 NEAs. To accomplish this, NASA is conducting the Near-Earth Object (NEO) Human Space Flight (HSF) Accessible Targets Study (NHATS). Phase I of the NHATS was executed during September of 2010, and Phase II was completed by early March of 2011. The study is ongoing because previously undetected NEAs are being discovered constantly, which has motivated an effort to automate the analysis algorithms in order to provide continuous monitoring of NEA accessibility. The NHATS analysis process consists of a trajectory filter and a minimum maximum estimated size criterion. The trajectory filter employs the method of embedded trajectory grids to compute all possible ballistic round-trip mission trajectories to every NEA in the Jet Propulsion Laboratory (JPL) Small-Body Database (SBDB) and stores all solutions that satisfy the trajectory filter criteria. An NEA must offer at least one qualifying trajectory solution to pass the trajectory filter. The Phase II NHATS filter criteria were purposely chosen to be highly inclusive, requiring Earth departure date between January 1st, 2015 and December 31st, 2040, total round-trip flight time <= 450 days, stay time at the NEA >= 8 days, Earth departure C(sub 3) energy <= 60 km(exp 2)/s(exp 2), total mission delta-v <= 12 km/s (including an Earth departure maneuver from a 400 km altitude circular parking orbit), and a maximum atmospheric re-entry speed of 12 km/s. After determining which NEAs offer at least one trajectory solution meeting the criteria, the estimated size constraint is then imposed whereby those NEAs may only be considered NHATS- qualifying NEAs if their maximum estimated size is >= 30 m. This corresponds to an absolute magnitude H <= 26.5 with an assumed albedo p = 0:05. The following is a brief high-level summary of the Phase II study results. Of the 7,665 NEAs in the SBDB as of February 3rd, 2011, 765 NEAs passed the trajectory filter and yielded a total of 79,157,604 trajectory solutions. The trajectory solutions for each NEA are post-processed into Pork Chop Contour (PCC) plots which show total mission delta-v as a function of Earth departure date and total mission duration. Although the PCC plots necessarily compress a very multi-dimensional design space into a two-dimensional plot, they permit rapid assessment of the breadth and quality of an NEA's available Earth departure season and clearly indicate the regions of the trajectory design space which warrant further analysis and optimization. The PCC plot for the NEA with the greatest number of NHATS-qualifying trajectory solutions, 2000 SG-344, is shown. Of the 765 NEAs which passed the Phase II trajectory filter, a total of 590 NEAs also satisfied the further constraint of maximum estimated size >= 30 m. The distributions of osculating heliocentric orbital semi-major axis (a), eccentricity (e), and inclination (i), for those 590 NEAs are shown. Note that the semi-latus rectum used is equal to alpha (1-e(exp 2)). To further our understanding of round-trip trajectory accessibility dynamics, it is instructive to examine the distribution of the NHATS-Qualifying NEAs according to orbit classification. NEAs are grouped into four orbit families: Atiras (aphelion < 0.983 AU), Atens (aphelion > 0.983 AU, alpha < 1.0 AU), Apollos (perihelion < 1.017 AU, alpha > 1.0 AU), and Amors (1.017 < perihelion < 1.3 AU). Of the 765 NEAhich satisfied the NHATS trajectory criteria, none are Atiras, 193 are Atens (31% of known Atens), 456 are Apollos (11% of known Apollos), and 116 are Amors (4% of known Amors). While Apollos comprise 60% of the NEAs which pass the NHATS trajectory filter and Atens comprise only 25%, the percentages according to orbit family are perhaps more relevant. Note that only 11% of known Apollos passed the trajectory filter while 31% of known Atens passed. These simple statistics alone strongly suggest that Aten orbits possess features which tend to enhance their round-trip trajectory accessibility as compared to Apollos or Amors. This is significant because Atens' orbits cause them to spend considerable time in Earth's daytime sky, making them difficult to discover and track using ground-based observing assets. In this paper we will detail the NHATS analysis algorithms, present and analyze all NHATS results to date, and discuss aspects of HSF mission architecture design for future NEA missions.

Barbee, Brent↗

Machine-Learned Manifold-Based Models for Large Eddy Simulation of Turbulent Combustion

Reduced-order manifold combustion models are commonly used to lower the cost of reacting Large Eddy Simulations (LES) and may be derived either from physical principles as in flamelet models or from data-driven methods like Principal Component Analysis (PCA). In either case, neural networks are increasingly used as part of these models to provide a nonlinear mapping between a small set of pre-defined variables that parameterize the manifold and outputs of interest, such as reaction rates. In this work, we propose a new manifold-based modeling approach that combines the definition of the manifold-parameterizing variables (linear combinations of species), the nonlinear mapping to the outputs, and closure of filtered quantities for LES into the structure of a single neural network. This allows the process used to train the neural network to simultaneously optimize both the functional form of the model and the identities of the inputs to the model. The new approach can flexibly incorporate thermochemical data from any combustion system; if trained on data from 1D flames it can be interpreted as an optimized flamelet model, but it can also be used to learn models from data from more complex configurations. This work presents a priori evaluations of the new approach in both contexts. Evaluation using data from 1D premixed flames demonstrates the physical interpretability of the manifold variables generated by the new approach. Evaluation using data from direct numerical simulations of turbulent flames shows improved predictions relative to either flamelet or PCA-based models in a more complex configuration.

47 OTHER INSTRUMENTATION↗

Motion Cueing Algorithm Modification for Improved Turbulence Simulation

Atmospheric turbulence cueing produced by flight simulator motion systems has been less than satisfactory because the turbulence profiles have been attenuated by the motion cueing algorithms. Cardullo and Ellor initially addressed this problem by directly porting the turbulence model output to the motion system. Reid and Robinson addressed the problem by employing a parallel aircraft model, which is only stimulated by the turbulence inputs and adding a filter specially designed to pass the higher turbulence frequencies. There have been advances in motion cueing algorithm development at the Man-Machine Systems Laboratory, at SUNY Binghamton. In particular, the system used to generate turbulence cues has been studied. The Reid approach, implemented by Telban and Cardullo, was employed to augment the optimal motion cueing algorithm installed at the NASA LaRC Simulation Laboratory, driving the Visual Motion Simulator. In this implementation, the output of the primary flight channel was added to the output of the turbulence channel and then sent through a non-linear cueing filter. The cueing filter is an adaptive filter; therefore, it is not desirable for the output of the turbulence channel to be augmented by this type of filter. The likelihood of the signal becoming divergent was also an issue in this design. After testing on-site it became apparent that the architecture of the turbulence algorithm was generating unacceptable cues. As mentioned above, this cueing algorithm comprised a filter that was designed to operate at low bandwidth. Therefore, the turbulence was also filtered, augmenting the cues generated by the model. If any filtering is to be done to the turbulence, it will utilize a filter with a much higher bandwidth, above the frequencies produced by the aircraft response to turbulence. The authors have developed an implementation wherein only the signal from the primary flight channel passes through the nonlinear cueing filter. This paper discusses three new algorithms. Testing shows that the new methods provide the pilot with a more realistic sensation of turbulence; the cues are not attenuated by algorithm. Results of offline testing show the credibility of the models. Offline test verification was based primarily on the evaluation of the power spectral density of the outputs and the time response.

Ercole, Anthony V.↗

Silicon Micromachining for Terahertz Component Development

Waveguide component technology at terahertz frequencies has come of age in recent years. Essential components such as ortho-mode transducers (OMT), quadrature hybrids, filters, and others for high performance system development were either impossible to build or too difficult to fabricate with traditional machining techniques. With micromachining of silicon wafers coated with sputtered gold it is now possible to fabricate and test these waveguide components. Using a highly optimized Deep Reactive Ion Etching (DRIE) process, we are now able to fabricate silicon micromachined waveguide structures working beyond 1 THz. In this paper, we describe in detail our approach of design, fabrication, and measurement of silicon micromachined waveguide components and report the results of a 1 THz canonical E-plane filter.

Filter↗

Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly increased with increasing kVp while for post-contrast imaging 90 kVp or lower yielded higher CNR images, depending on the differential iodine concentration of each tissue. Similar trends were seen in DE blended CNR and those from SE protocols. In the presence of differential iodine concentration (i.e., post-contrast), the CNR curves maximize at lower kVps (80–120), with the peak shifted rightward for larger patients. The combined pre- and post-contrast composite CNR study demonstrated that an optimal SE protocol has better performance than blended DE images, and the optimal tube potential for SE scan is around 90 kVp for a medium size patients and between 90 and 120 kVp for large size patients (although low kVp imaging requires high x-ray tube power to avoid photon starvation). Also, a tin filter added to the high kVp beam is not only beneficial for material decomposition but it improves the CNR of the DE blended images as well. The dose adjusted CNR of the clinical images also showed the same trend and radiologists favored the SE scans over blended DE images. Conclusions: Our simulation showed that an optimized SE protocol produces up to 5% higher CNR for a range of clinical tasks. The clinical study also suggested 120 kVp SE scans have better image quality than blended DE images. Hence, blended DE images do not have a fundamental CNR advantage over optimized SE images.

60 APPLIED LIFE SCIENCES↗