Search NASA⌕ Search

SEARCH · Search NASA

Results for “harmonic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Response of a rigid aircraft to nonstationary atmospheric turbulence.

The plunging response of an aircraft to a type of nonstationary turbulent excitation is considered. The latter consists of stationary Gaussian noise modulated by a well-defined envelope function. The intent of the investigation is to model the excitation experienced by an airplane flying through turbulence of varying intensity and to examine the influence of intensity variations on exceedance frequencies of the gust velocity and the airplane's plunging velocity and acceleration. One analytical advantage of the proposed model is that the Gaussian assumption for the gust excitation is retained. The analysis described herein is developed in terms of an envelope function of arbitrary form; however, numerical calculations are limited to the case of harmonic modulation.

Verdon, J. M.↗

Identification of limit cycles in multi-nonlinearity, multiple path systems

A method of analysis which identifies limit cycles in autonomous systems with multiple nonlinearities and multiple forward paths is presented. The FORTRAN code for implementing the Harmonic Balance Algorithm is reported. The FORTRAN code is used to identify limit cycles in multiple path and nonlinearity systems while retaining the effects of several harmonic components.

Mitchell, J. R.↗

Spontaneous synchrotron emission from a plasma with an energetic runaway electron tail

The emissivity of spontaneous synchrotron radiation is computed for a plasma consisting of a background thermal plasma in addition to an energetic runaway electron component. The analysis is performed for both the ordinary and extraordinary modes, for frequencies in the vicinity of the electron plasma frequency and the higher harmonics of the electron gyrofrequency, and for the case when the electron plasma frequency is approximately the same as or smaller than the cyclotron frequency. The relativistic gyroresonance with the runaway electrons is found to result in a level of spontaneous emission which, for frequencies in the neighborhood of the electron plasma frequency, is significantly enhanced over the thermal radiation.

Freund, H. P.↗

An analysis of short pulse and dual frequency radar techniques for measuring ocean wave spectra from satellites

A four frequency moment characterization of backscatter from the near-vertical is applied to an analysis of the short pulse and dual frequency microwave techniques. The range reflectivity modulation spectrum closely approximates the directional wave slope spectrum, while harmonic distortion is small and is a minimum near 10 deg incidence. The short pulse measurement signal-to-noise ratio (SNR) is typically greater than the narrowband dual frequency SNR, with the difference being the ratio of the range beam extent to pulse length, minus the ratio of beam-limited to pulse-limited Doppler spreads. It is concluded that dual frequency measurements are basically impractical, although short pulse measurements are useful and can employ existing space-qualified microwave hardware.

Jackson, F. C.↗

Large-scale variations in observed Antarctic Sea ice extent and associated atmospheric circulation

The 1974 Antarctic large scale sea ice extent is studied from data from Nimbus 2 and 5 and temperature and sea level pressure fields from the Australian Meteorological Data Set. Electrically Scanning Microwave Radiometer data were three-day averaged and compared with 1000 mbar atmospheric pressure and sea level pressure data, also in three-day averages. Each three-day period was subjected to a Fourier analysis and included the mean latitude of the ice extent and the phases and percent variances in terms of the first six Fourier harmonics. Centers of low pressure were found to be generally east of regions which displayed rapid ice growth, and winds acted to extend the ice equatorward. An atmospheric response was also noted as caused by the changing ice cover.

Cavalieri, D. J.↗

Interplanetary radio storms. II - Emission levels and solar wind speed in the range 0.05-0.8 AU

Storms of interplanetary type III radio bursts (IP storms) are commonly observed in the interplanetary medium by the ISEE-3 radio instrument. This instrument has the capability of accurately determining the arrival direction of the radio emission. At each observing frequency, the storm radio sources are tracked as they cross the line-of-sight to the sun. Using a simple model, the emission levels are determined at a number of radio frequencies for four separate storms. The IP storm radiation is found to occur in regions of enhanced density at levels of 0.05 to 0.8 AU. The density in these enhancements falls off faster than R(-2). The solar wind speed in the storm region is also measured. The analysis is consistent with steady conditions in the storm region during a few days around the III storm burst radio emission at the harmonic of the local plasma frequency.

Bougeret, J.-L.↗

Optimizing tuning masses for helicopter rotor blade vibration reduction including computed airloads and comparison with test data

The development and validation of an optimization procedure to systematically place tuning masses along a rotor blade span to minimize vibratory loads are described. The masses and their corresponding locations are the design variables that are manipulated to reduce the harmonics of hub shear for a four-bladed rotor system without adding a large mass penalty. The procedure incorporates a comprehensive helicopter analysis to calculate the airloads. Predicting changes in airloads due to changes in design variables is an important feature of this research. The procedure was applied to a one-sixth, Mach-scaled rotor blade model to place three masses and then again to place six masses. In both cases the added mass was able to achieve significant reductions in the hub shear. In addition, the procedure was applied to place a single mass of fixed value on a blade model to reduce the hub shear for three flight conditions. The analytical results were compared to experimental data from a wind tunnel test performed in the Langley Transonic Dynamics Tunnel. The correlation of the mass location was good and the trend of the mass location with respect to flight speed was predicted fairly well. However, it was noted that the analysis was not entirely successful at predicting the absolute magnitudes of the fixed system loads.

Pritchard, Jocelyn I.↗

Theory and operation of a three-gate time-of-flight velocity analyzer

Theoretical considerations and test results are presented for a new-type velocity analyzer for incident fast neutral particles, positive ions, and negative ions. Velocity analysis is carried out by means of a pulsed, three-gate time-of-flight (TOF) technique capable of eliminating alias velocities (harmonics) to sixth order. In addition the design and operation are presented of a four-element ion lens system, with small spherical and chromatic aberrations, suitable for interfacing a large-diameter ion beam from the TOF section with a subsequent mass analyzer.

Martus, K. E.↗

An Accurate Quartic Force Field and Vibrational Frequencies for HNO and DNO

An accurate ab initio quartic force field for HNO has been determined using the singles and doubles coupled-cluster method that includes a perturbational estimate of the effects of connected triple excitations, CCSD(T), in conjunction with the correlation consistent polarized valence triple zeta (cc-pVTZ) basis set. Improved harmonic frequencies were determined with the cc-pVQZ basis set. Fundamental vibrational frequencies were determined using a second-order perturbation theory analysis and also using variational calculations. The N-0 stretch and bending fundamentals are determined well from both vibrational analyses. The H-N stretch, however, is shown to have an unusually large anharmonic correction, and is not well determined using second-order perturbation theory. The H-N fundamental is well determined from the variational calculations, demonstrating the quality of the ab initio quartic force field. The zero-point energy of HNO that should be used in isodesmic reactions is also discussed.

Dateo, Christopher E.↗

High Frequency Acoustic Response Characterization and Analysis of the Deep Throttling Common Extensible Cryogenic Engine

The Common Extensive Cryogenic Engine program demonstrated the operation of a deep throttling engine design. The program, spanning five years from August 2005 to July 2010, funded testing through four separate engine demonstration test series. Along with successful completion of multiple objectives, a discrete response of approximately 4000 Hz was discovered and explored throughout the program. The typical low-amplitude acoustic response was evident in the chamber measurement through almost every operating condition; however, at certain off-nominal operating conditions, the response became discrete with higher amplitude. This paper summarizes the data reduction, characterization, and analysis of the 4,000 Hz response for the entire program duration, using the large amount of data collected. Upon first encountering the response, new objectives and instrumentation were incorporated in future test series to specifically collect 4,000 Hz data. The 4,000 Hz response was identified as being related to the first tangential acoustic mode by means of frequency estimation and spatial decomposition. The latter approach showed that the effective node line of the mode was aligned with the manifold propellant inlets with standing waves and quasi-standing waves present at various times. Contour maps that contain instantaneous frequency and amplitude trackings of the response were generated as a significant improvement to historical manual approaches of data reduction presentation. Signal analysis and dynamic data reduction also uncovered several other features of the response including a stable limit cycle, the progressive engagement of subsequent harmonics, the U-shaped time history, an intermittent response near the test-based neutral stability region, other acoustic modes, and indications of modulation with a separate subsynchronous response. Although no engine damage related to the acoustic mode was noted, the peak-to-peak fluctuating pressure amplitude achieved 12.1% of the mean chamber pressure at its highest. The identification of this response in terms of an instability is also discussed.

Casiano, M. J.↗

Frequency-dependent hydrodynamic inductance and the determination of the thermal and quantum noise of a superfluid gyroscope

We reexamine mass flow in a superfluid gyroscope containing a superfluid Josephson weak link. We introduce a frequency-dependent hydrodynamic inductance to account for an oscillatory flow of the normal fluid component in the sensing loop. With this hydrodynamic inductance, we derive the thermal phase noise, and hence the thermal rotational noise of the gyroscope. We examine the thermodynamic stability of the system based on an analysis of the free energy. We derive a quantum phase noise, which is analogous to the zero-point motion of a simple harmonic oscillator. The configuration of the studied gyroscope is analogous to a conventional superconducting RF SQUID. We show that the gyroscope has very low intrinsic noise (1.9x10(-13) rad s(-1)/root Hz), and it can potentially be applied to study general relativity, Earth science, and to improve global positioning systems (GPS).

Penanen, Konstantin↗

Implementation of hybrid finite element method based transport solver in GRIFFIN

A new transport solver option based on the hybrid FEM (HFEM) was implemented in GRIFFIN, the MOOSE-based reactor analysis code, as an effort to support routine core design calculations for advanced reactor applications. The HFEM formulation with P{sub N} (spherical harmonics expansion), akin to the variational nodal method, is effective for solving a spatially homogenized problem with strong transport effect. The residual and Jacobian evaluations of the HFEM weak form were derived and successfully implemented in GRIFFIN, having the diffusion and the PN options available in the new HFEM based transport solver. The performance was tested with the simplified ABTR benchmark problems. The results indicate that the HFEM-based transport solver is a feasible option for solving problems with spatially homogenized and strong streaming by providing superior accuracy with a proper p-refinement. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Lunar Crustal Thickness from Analysis of the Lunar Prospector Gravity and Clementine Topography Datasets

The Lunar Prospector spacecraft has mapped the gravity field of the Moon to a level of resolution never achieved before, and a spherical harmonic representation to degree and order 100 is available. When combined with the topography dataset produced by the Clementine mission, the resulting Bouguer anomaly map is interpreted to model the thickness of the lunar crust. Such models are crucial to understanding the lunar thermal history and the formation of geological features such as mascon basins, several more of which have been newly discovered from this dataset. A two-layer planetary model was used to compute the variations of the depth to the lunar Moho. The thickness values ranged from near 0 to 120 km. There is significant agreement with previous work using the Clementine gravitational field data with differences in specific locations such as South Pole-Aitken Basin, for example.

Asmar, S.↗

Frequency–wavenumber spectral analysis of spatio-temporal flows

We propose a fully spatio-temporal approach for identifying spatially varying modes of oscillation in fluid dynamics simulation output by means of multitaper frequency–wavenumber spectral analysis. One-dimensional spectrum estimation has proven to be a valuable tool in the analysis of turbulence data applied spatially to determine the rate of energy transport between spatial scales, or temporally to determine frequencies of oscillatory flows. It also allows for the quantitative comparison of flow characteristics between two scenarios using a standard basis. It has the limitation, however, that it neglects coupling between spatial and temporal structures. Two-dimensional frequency–wavenumber spectral analysis allows one to decompose waveforms into standing or travelling variety. The extended higher-dimensional multitaper method proposed here is shown to have improved statistical properties over conventional non-parametric spectral estimators, and is accompanied by confidence intervals which estimate their uncertainty. Multitaper frequency–wavenumber analysis is applied to a canonical benchmark problem, namely, a direct numerical simulation of von Kármán vortex shedding off a square wall-mounted cylinder with two inflow scenarios with matching momentum-thickness Reynolds numbers $Re_{\unicode[STIX]{x1D703}}\approx 1000$ at the obstacle. Frequency–wavenumber analysis of a two-dimensional section of these data reveals that although both the laminar and turbulent inflow scenarios show a turbulent $-5/3$ cascade in wavenumber ( $\unicode[STIX]{x1D708}$ ) and frequency ( $f$ ), the flow characteristics differ in that there is a significantly more prominent discrete harmonic oscillation near $(f,\unicode[STIX]{x1D708})=(0.2,0.21)$ in wavenumber and frequency in the laminar inflow scenario than the turbulent scenario. This frequency–wavenumber pair corresponds to a travelling wave with velocity near one near the centre path of the vortex street.

Geoga, Christopher J. (ORCID:0000000250604799)↗

Search for the chiral magnetic effect with isobar collisions at $\sqrt{s_{NN}}$ = 200 GeV by the STAR Collaboration at the BNL Relativistic Heavy Ion Collider

The chiral magnetic effect (CME) is predicted to occur as a consequence of a local violation of P and CP symmetries of the strong interaction amidst a strong electro-magnetic field generated in relativistic heavy-ion collisions. Experimental manifestation of the CME involves a separation of positively and negatively charged hadrons along the direction of the magnetic field. Previous measurements of the CME-sensitive charge-separation observables remain inconclusive because of large background contributions. In order to better control the influence of signal and backgrounds, the STAR Collaboration performed a blind analysis of a large data sample of approximately 3.8 billion isobar collisions of $^{96}_{44}$Ru + $^{96}_{44}$Ru and $^{96}_{40}$Zr + $^{96}_{40}$Zr at $\sqrt{s_{NN}}$ = 200 GeV. Prior to the blind analysis, the CME signatures are predefined as a significant excess of the CME-sensitive observables in Ru + Ru collisions over those in Zr + Zr collisions, owing to a larger magnetic field in the former. Here, a precision down to 0.4% is achieved, as anticipated, in the relative magnitudes of the pertinent observables between the two isobar systems. Observed differences in the multiplicity and flow harmonics at the matching centrality indicate that the magnitude of the CME background is different between the two species. No CME signature that satisfies the predefined criteria has been observed in isobar collisions in this blind analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A detailed radiobiological and dosimetric analysis of biochemical outcomes in a case-control study of permanent prostate brachytherapy patients

The purpose of this study is to determine dosimetric and radiobiological predictors of biochemical control after recalculation of prostate implant dosimetry using updated AAPM Task Group 43 (TG-43) parameters and the radiobiological parameters recommended by TG-137. All biochemical failures among patients implanted with {sup 125}I or {sup 103}Pd sources between 1994 and March 2006 were matched 2:1 with nonfailure controls. The individual matching was by risk group, radionuclide, prescribed dose, and time of implant (one match before and one after the failed patient) resulting in a median follow-up of 10.9 years. Complete dose volume histogram (DVH) data were recalculated for all 55 cases and 110 controls after updating the original source strength by the retrospectively determined ratios of TG-43. Differential DVH data were acquired in 179 increments of prostate volume versus percentage prescribed dose. At each incremental dose level i, the biologically equivalent dose BED{sub i}, equivalent uniform dose EUD{sub i}, and tumor control probability TCP{sub i} were calculated from the implant dose plus any external beam delivered to the patient. Total BED, EUD, and TCP were then derived from the incremental values for comparison with single point dosimetric quality parameters and DVH-based averages. There was no significant difference between failures and controls in terms of total BED (143 vs 142 Gy), EUD (95 vs 94 Gy), or TCP (0.87 vs 0.89). Conditional logistic regression analysis factored out the matching variables and stratified the cohort into each case and its controls, but no radiobiological parameter was predictive of biochemical failure. However, there was a significant difference between radiobiological parameters of {sup 125}I and {sup 103}Pd due to less complete coverage of the target volume by the former isotope. The implant BED and TCP were highly correlated with the D{sub 90} and natural prescription doses and a series of mean DVH-based doses such as the harmonic mean and expressions of the generalized EUD. In this case-control study of prostate brachytherapy biochemical failures and nonfailures, there were no radiobiological parameters derived from detailed DVH-based analysis that predicted for biochemical control. This may indicate that in our approach, implant dosimetry is at or near the limits of clinically effective dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature dependences of the ferroelectric and dielectric properties of high curie temperature PbTiO{sub 3}–BiScO{sub 3}–Bi(Zn{sub 1/2}Zr{sub 1/2})O{sub 3}

Highlights: ► Ceramics exhibit enhanced ferroelectric properties with the increase of temperature. ► A strong second harmonic generation effect was observed. ► Transmission electron microscopy results confirm the existence of MPB. - Abstract: The piezoelectric ceramics (1 − x − y)PbTiO{sub 3}–xBiScO{sub 3}–yBi(Zn{sub 1/2}Zr{sub 1/2})O{sub 3} exhibit greatly enhanced ferroelectric properties above room temperature, between 100 and 200 °C. A strong second harmonic generation (SHG) effect was observed below 200 °C. The highest remanent polarization (∼40 μC/cm{sup 2}) and lowest coercive field (∼10 kV/cm) were obtained at 200 °C. X-ray diffraction (XRD) analysis was used to investigate the morphotropic phase boundary (MPB) structure of (1 − x − y)PbTiO{sub 3}–xBiScO{sub 3}–yBi(Zn{sub 1/2}Zr{sub 1/2})O{sub 3} ceramics. Transmission electron microscopy (TEM) results confirm the existence of MPB, where the rhombohedral and tetragonal phases coexist. The results of thermal expansion analysis show a low thermal expansion and stability of this material. The optimal high temperature piezoelectric ceramic is obtained by the composition of 0.05BZZ–0.34BS–0.61PT.

36 MATERIALS SCIENCE↗

WE-AB-204-05: Harmonizing PET/CT Quantification in Multicenter Studies: A Case Study

Purpose: To present the implementation of a strategy to harmonize FDG PET/CT quantification (SUV), performed with different scanner models and manufacturers. Methods: The strategy was based on Boellaard (2011) and EARL FDG-PET/CT accreditation program, that propose quality control measurements for harmonizing scanner performance. A NEMA IEC Body phantom study was performed using four different devices: PHP-1 (Gemini TF Base, Philips); PHP-2 (Gemini GXL, Philips); GEH (Discovery 600, General Electric); SMS (Biograph Hi-Rez 16, Siemens). The SUV Recovery Coefficient (RC) was calculated using the clinical protocol and other clinically relevant reconstruction parameters. The most appropriate reconstruction parameters (MARP) for SUV harmonization, in each scanner, are those which achieve EARL harmonizing standards. They were identified using the lowest root mean square errors (RMSE). To evaluate the strategy’s effectiveness, the Maximum Differences (MD) between the clinical and MARP RC values were calculated. Results: The reconstructions parameters that obtained the lowest RMSE are: FBP 5mm (PHP-1); LOR-RAMLA 2i0.008l (PHP-2); VuePointHD 2i32s10mm (GEH); and FORE+OSEM 4i8s6mm (SMS). Thus, to ensure that quantitative PET image measurements are interchangeable between these sites, images must be reconstructed with the above-mentioned parameters. Although, a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies was observed. The MD showed that the strategy was effective in reducing the variability of SUV quantification for small structures (<17mm). Conclusion: The harmonization strategy of the SUV quantification implemented with these devices was effective in reducing the variability of small structures quantification, minimizing the inter-scanner and inter-institution differences in quantification. However, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation must be maintained, in order to minimize the SUV variability due to biological factors. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗