Search NASA⌕ Search

SEARCH · Search NASA

Results for “high level application”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Development of at-wavelength metrology for x-ray optics at the ALS

The comprehensive realization of the exciting advantages of new third- and forth-generation synchrotron radiation light sources requires concomitant development of reflecting and diffractive x-ray optics capable of micro- and nano-focusing, brightness preservation, and super high resolution. The fabrication, tuning, and alignment of the optics are impossible without adequate metrology instrumentation, methods, and techniques. While the accuracy of ex situ optical metrology at the Advanced Light Source (ALS) has reached a state-of-the-art level, wavefront control on beamlines is often limited by environmental and systematic alignment factors, and inadequate in situ feedback. At ALS beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of tests with increasing accuracy and sensitivity. Geometric Hartmann tests, performed with a scanning illuminated sub-aperture determine the wavefront slope across the full mirror aperture. Shearing interferometry techniques use coherent illumination and provide higher sensitivity wavefront measurements. Combining these techniques with high precision optical metrology and experimental methods will enable us to provide in situ setting and alignment of bendable x-ray optics to realize diffraction-limited, sub 50 nm focusing at beamlines. We describe here details of the metrology beamline endstation, the x-ray beam diagnostic system, and original experimental techniques that have already allowed us to precisely set a bendable KB mirror to achieve a focused spot size of 150 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DC-Link Capacitor Design for a Neutral-Point-Less Three-Level Dual-Phase Inverter for Traction Application

Conventional multilevel inverters, such as neutral￾point-clamped and T-type inverters, have gained popularity in electric vehicle applications due to their advantages, including high voltage range, high power capability, low switching losses, low total harmonic distortion, and low electromagnetic interference. However, these traditional multilevel inverters require a neutral point connection to generate a zero-voltage vector. The neutral point current oscillates at three times the fundamental frequency, leading to voltage imbalance and overvoltage stress on the power modules. Additionally, the use of two stacked DC-link capacitors increases the volume required for the same overall capacitance and complicates packaging due to ripple current and heat dissipation from separate components. This is a significant concern for traction drive units, where space is limited. In this paper, a neutral-point-less multilevel dual three￾phase inverter topology is investigated for traction inverter applications. Simulation results demonstrate that the proposed topology effectively retains the benefits of multilevel operation while utilizing a single DC-link capacitor. The inverter model was simulated in conjunction with an industry-standard battery model to evaluate the potential for capacitor size reduction compared to a conventional three-level inverter.

33 ADVANCED PROPULSION SYSTEMS↗

Deep-learning-based canopy height model generation from sub-meter resolution panchromatic satellite imagery

Canopy height models (CHMs) with sufficient resolution to distinguish individual trees are useful for a variety of applications. However, standard techniques to acquire such data, such as airborne lidar surveying, are often prohibitively expensive. Deep learning techniques for generating CHMs from high-resolution imagery are an attractive option to reduce costs. To date, success with these methods has been demonstrated using multichannel aerial photography and specialized satellite data products derived from multiple sensors, neither of which is commonly available at temporal resolutions finer than one year. Here we demonstrate a method to generate sub-meter resolution CHMs in three forests in California using a more abundant data source: sub-meter resolution, panchromatic satellite imagery from a single sensor. We show that phenology and species composition play important roles in model transferability; when trained using imagery from a single conifer forest in autumn, the model performs well on autumn imagery from a second conifer forest several hundred kilometers distant with no re-training. With modest additions to the training dataset, the same model generates minimally biased estimates of canopy height in both conifer and deciduous forests during multiple seasons. Because the model operates on satellite data with global coverage and a relatively short return interval, we propose its suitability to extrapolate tree-level canopy height data to remote regions and conduct high-temporal resolution monitoring of forest structure. We furthermore demonstrate the workflow’s applicability to fire modeling by conducting simulations in forests populated by trees measured using both this approach and airborne lidar surveying. We find minimal differences in fire behavior relative to a baseline case in which only statistical distributions of tree height and crown area are known. This result underscores the value of forest structural information derived from our workflow for improving the fidelity of wildland fire simulations, among other ecological applications.

54 ENVIRONMENTAL SCIENCES↗

Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum

Purpose: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. Methods: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. Results: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. Conclusions: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SiC and GaN Devices With Cryogenic Cooling

This article presents the cryogenically cooled application for wide bandgap (WBG) semiconductor devices. Characteristics of silicon carbide (SiC) and gallium nitride (GaN) at cryogenic temperatures are illustrated. SiC MOSFETs exhibit increased on-state resistance and slower switching speed at cryogenic temperatures. However, cryogenic cooling provides low ambient temperature environment and thus enables the SiC converter to operate at lower junction temperature to achieve higher efficiency compared to room temperature cooling. A cryogenically cooled MW-level SiC inverter prototype is developed and demonstrated the feasibility of operating high-power SiC converter with cryogenic cooling. GaN HEMTs exhibit more than five times on-state resistance reduction and faster switching speed at cryogenic temperatures which makes GaN HEMTs an excellent candidate for cryogenic power electronics applications. The significantly reduced on-state resistance of GaN devices provides the possibility to operate them at a current level much higher than rated current at cryogenic temperatures. A GaN double pulse test (DPT) circuit is constructed and demonstrated that GaN HEMTs can operate at nearly four times of rated current at cryogenic temperatures. Challenges of utilizing WBG device with cryogenic cooling are discussed and summarized.

42 ENGINEERING↗

AutonomieAI: An efficient and deployable vehicle energy consumption estimation toolkit

Here, this paper presents AutonomieAI, a novel toolkit designed for efficient energy estimation of vehicles across diverse trip scenarios, routes, and drive cycles, applicable to a broad range of vehicle powertrain technologies. It leverages state-of-the-art Machine Learning techniques to deliver real-time energy prediction of vehicles, enabling co-simulation with transportation level system tools and opening doors for large-scale optimization at city, network or national level. Benchmark results show that AutonomieAI achieves high accuracy, with an average percentage error below 2% for most powertrain types, and computational efficiency capable of processing over 10,000 trips per second. Applications of AutonomieAI have potential to offer the flexibility to assist in solving eco-routing problems, optimize for vehicle and powertrain selection, study charging decision behavior, and optimize for charging station placement. AutonomieAI is the result of large neural network based model architectures, trained on very large and unique high fidelity vehicle simulation data. It is lightweight, deployable, efficient and has accuracy comparable to specialized and complex physics based simulation softwares.

Autonomie↗

ICAROUS: Integrated Configurable Architecture for Unmanned Systems

NASA's Unmanned Aerial System (UAS) Traffic Management (UTM) project aims at enabling near-term, safe operations of small UAS vehicles in uncontrolled airspace, i.e., Class G airspace. A far-term goal of UTM research and development is to accommodate the expected rise in small UAS traffic density throughout the National Airspace System (NAS) at low altitudes for beyond visual line-of-sight operations. This video describes a new capability referred to as ICAROUS (Integrated Configurable Algorithms for Reliable Operations of Unmanned Systems), which is being developed under the auspices of the UTM project. ICAROUS is a software architecture comprised of highly assured algorithms for building safety-centric, autonomous, unmanned aircraft applications. Central to the development of the ICAROUS algorithms is the use of well-established formal methods to guarantee higher levels of safety assurance by monitoring and bounding the behavior of autonomous systems. The core autonomy-enabling capabilities in ICAROUS include constraint conformance monitoring and autonomous detect and avoid functions. ICAROUS also provides a highly configurable user interface that enables the modular integration of mission-specific software components.

Consiglio, Maria C.↗

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Maximizing the Proppant Carrying and Viscoelastic Properties of the Bakken Hypersaline-Produced Water with High-Viscosity Friction Reducers for Sustainable Applications

Summary The development and production of unconventional reservoirs, such as the Bakken Formation, have become a resolved mystery for operators in North America since the arrival and advancement of horizontal drilling and hydraulic fracturing technologies. As a result, unconventional reservoir assets became the central focus of the oil and gas industry at the state, national, and global levels. The produced water from these activities in the Bakken Formation have high salt contents (110,000–350,000 ppm) total dissolve solids (TDS) and can pose significant challenges to the environment if not treated. Deep injection into disposal wells is the routine method used to get rid of the Bakken produced water. However, there have been some concerns that unrestrained injections, in addition to polluting the groundwater, could potentially lead to seismic activities either at the time of injection or in the near future. To diminish the environmental impacts that may be associated with induced seismicity, including the reduction of the costs of water acquisition, the produced water can be treated and reused in the hydraulic fracturing processes. Also, the treated water could be used for irrigation purposes, for power generation, and coal mining operations. The issues of waste water and residual oil high in TDS are challenges yet to be effectively addressed despite preceding research and studies on advancing produced water technologies. The goal of this study is to explore all applicable ways by which the produced water from the Bakken Formation can serve as a replacement base fluid for use with polymers like the high-viscosity friction reducers (HVFRs) to create hydraulic fracturing fluids that can be stable with reservoir conditions and also be able to minimize environmental impacts and cost of operations. Experimental investigations using the high-salinity produced water from the Bakken Formation with HVFRs were carried out. The studies included a base case that served as a bench mark for comparing the effectiveness of the other scenarios. The results indicate that the Bakken hyper-saline produced water can withstand effect of heavy metals, salinity, hardness and remain stable through different shear rates (66–330 s−1) when treated with higher dosages [4–8 gal/1,000 gal (gpt)] of HVFRs. Filtration and dilution were the only methods used on the Bakken Formation produced wate for this research

Engineering↗

Enabling Scientific Applications with Performance-Portability and High-Productivity for Multi-GPU Programming with JACC.Multi

This work bridges the gap between multi-GPU computing and high-productivity, performance-portable programming solutions. Our goal is to enhance scientific applications with a productive and portable solution—program once, deploy everywhere—for multi-GPU programming with no cost to programmability. To accomplish this, we implemented JACC.Multi, which is part of the Julia for ACCelerators (JACC) performance-portable framework. JACC. Multi is the only high-level, portable metaprogramming solution that targets multi-GPU environments and is integrated in a readily accessible programming language (e.g., Julia language). With transparent GPU-to-GPU communication, JACC. Multi is optimized for scientific application workloads and is portable for NVIDIA and AMD accelerators. For the evaluation, we use two modern multi-GPU systems: Hudson, which features two NVIDIA H100 Hopper GPUs per node, and Frontier, which features four AMD MI250X GPUs per node, each with two Graphics Compute Dies (GCDs) for a total of eight GCDs per node. Additionally, as part of the evaluation, we use JACC (one GPU), MPI+JACC, and JACC. Multi codes that implement well-known and widely used scientific algorithms/kernels such as the conjugate gradient algorithm and an explicit forward Euler solver that requires GPU-to-GPU communication. Overall, JACC. Multi codes achieve better performance than MPI+JACC codes and significant speedups over JACC (one GPU), with up to 1.9× on Hudson and 6× on Frontier.

Valero Lara, Pedro [ORNL] (ORCID:0000000214794310)↗

Contextually aware roadside radiation measurement testbed

Here we demonstrate a contextually aware multimodal roadside radiation measurement detection testbed for traffic monitoring applications in nuclear nonproliferation. Many variables in traffic such as vehicle or cargo size, mass, speed, shape, and distance of closest approach can have significant impacts on the radiation measured from a vehicle-transported radiation source. These factors can lead to uncertainties in the analysis of the radiation source, especially for lower-strength radiation sources of interest. Our testbed, known as the Multimodal Measurement System (MMS) uses non-radiation sensors including magnetometers, geophones, radiofrequency receivers, cameras, and LiDAR to extract contextual information about vehicles passing by the system. These contextual data can then be fused with data from radiation measurements to increase the system’s sensitivity and accuracy in nuclear threat detection applications. This work describes the instrumentation of the MMS and its data acquisition pipeline. Furthermore, we describe the pre-analysis performed on the raw multimodal data streams for data fusion, and the high-level machine learning analyses for detection and characterization. The variety of sensors within the MMS provides a valuable testbed that can be used to identify the combinations of contextual sensors that provide the greatest improvements to radiation source detection and characterization within the restrictions for various proliferation detection applications. The MMS is also modular so that additional combinations of sensors can be explored in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low vibration high numerical aperture automated variable temperature Raman microscope

Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarization rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2 Se 3 and V 2 O 3 , which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ConnectX-2 InfiniBand Management Queues: First Investigation of the New Support for Network Offloaded Collective Operations

This paper introduces the newly developed Infini-Band (IB) Management Queue capability, used by the Host Channel Adapter (HCA) to manage network task data flow dependancies, and progress the communications associated with such flows. These tasks include sends, receives, and the newly supported wait task, and are scheduled by the HCA based on a data dependency description provided by the user. This functionality is supported by the ConnectX-2 HCA, and provides the means for delegating collective communication management and progress to the HCA, also known as collective communication offload. This provides a means for overlapping collective communications managed by the HCA and computation on the Central Processing Unit (CPU), thus making it possible to reduce the impact of system noise on parallel applications using collective operations. This paper further describes how this new capability can be used to implement scalable Message Passing Interface (MPI) collective operations, describing the high level details of how this new capability is used to implement the MPI Barrier collective operation, focusing on the latency sensitive performance aspects of this new capability. This paper concludes with small scale benchmark experiments comparing implementations of the barrier collective operation, using the new network offload capabilities, with established point-to-point based implementations of these same algorithms, which manage the data flow using the central processing unit. These early results demonstrate the promise this new capability provides to improve the scalability of high performance applications using collective communications. The latency of the HCA based implementation of the barrier is similar to that of the best performing point-to-point based implementation managed by the central processing unit, starting to outperform these as the number of processes involved in the collective operation increases.

Graham, Richard L↗

Optimization of the computational efficiency of a 3D, collapsed cone dose calculation algorithm for brachytherapy

Brachytherapy dose calculations based on point kernel superposition using the collapsed cone method have been shown to accurately model the influence from finite dimensions of the patient and effects from heterogeneities including those of high atomic numbers. The collapsed cone method is for brachytherapy applications most effectively implemented through a successive-scattering approach, in which the dose from once and higher order of scattered photons is calculated separately and in successive scatter order. The calculation speed achievable is directly proportional to the number of directions used for point kernel discretization and to the number of voxels in the volume. In this work we investigate how to best divide the total number of directions between the two steps of successive-scattering dose calculations. Results show that the largest fraction of the total number of directions should be utilized in calculating the first-scatter dose. Also shown is how the number of directions required for keeping discretization artifacts at acceptably low levels decreases significantly in multiple-source configurations, as a result of the dose gradients being less steep than those around single sources. Investigating the number of kernel directions required to keep artifacts low enough within the high dose region of an implant (i.e., for dose levels above approximately 5%-10% of the mean central target dose) reveals similar figures for brachytherapy as for external beam applications, where collapsed cone superposition is clinically used. Also shown is that approximating point kernels with their isotropic average leads to small dose differences at low and intermediate energies, implying that the collapsed cone calculations can be done in a single operation common to all sources of the implant at these energies. The current findings show that collapsed cone calculations can be achieved for brachytherapy with the same efficiency as for external beams. This, combined with recent results on gains in efficiency through implementing the algorithm on graphical card parallel hardware indicates that dose can be calculated with account for heterogeneities and finite dimensions within a few seconds for large voxel arrays and is therefore of interest for practical application to treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the high-resolution grazing-emission x-ray fluorescence method for impurities control in semiconductor nanotechnology

We report on the application of synchrotron radiation based high-resolution grazing-emission x-ray fluorescence (GEXRF) method to measure low-level impurities on silicon wafers. The presented high-resolution GEXRF technique leads to direct detection limits of about 10{sup 12} atoms/cm{sup 2}. The latter can be presumably further improved down to 10{sup 7} atoms/cm{sup 2} by combining the synchrotron radiation-based GEXRF method with the vapor phase decomposition preconcentration technique. The capability of the high-resolution GEXRF method to perform surface-sensitive elemental mappings with a lateral resolution of several tens of micrometers was probed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Engineering current density over 5 kA mm -2 at 4.2 K, 14 T in thick film REBCO tapes

We report on remarkably high in-field performance at 4.2 K achieved in >4 $μ$m thick rare earth barium copper oxide (REBCO) samples with Zr addition. Two different samples have been measured independently at Lawrence Berkeley National Laboratory and the National High Magnetic Field Laboratory, achieving critical current densities ( J c ) of 12.21 MA cm -2 and 12.32 MA cm -2 at 4.2 K, 14 T ($\small{B}$|| c ), respectively, which corresponds to equivalent critical current ( I c ) values of 2247 and 2119 A/4 mm. These I c values are about two times higher than the best reported performance of REBCO tapes to date and more than five times higher than the commercial HTS tapes reported in a recent study. The measured J c values, with a pinning force of ~1.7 T N m -3 are almost identical to the highest value reported for thin (~1 $μ$m thick) REBCO at the field and temperature, but extended to very thick (>4 μm) films. This results in an engineering current density ( J e ) above 5 kA mm -2 at 4.2 K, 14 T, which is more than five times higher than Nb 3 Sn and nearly four times higher than the highest reported value of all superconductors other than REBCO at this field and temperature. The reported results have been achieved by utilizing an advanced metal organic chemical vapor deposition system. This study demonstrates the remarkable level of in-field performance achievable with REBCO conductors at 4.2 K and strong potential for high-field magnet applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In pursuit of an accurate spatial and temporal model of biomolecules at the atomistic level: a perspective on computer simulation

The current computational techniques available for biomolecular simulation are described, and the successes and limitations of each with reference to the experimental biophysical methods that they complement are presented. Despite huge advances in the computational techniques available for simulating biomolecules at the quantum-mechanical, atomistic and coarse-grained levels, there is still a widespread perception amongst the experimental community that these calculations are highly specialist and are not generally applicable by researchers outside the theoretical community. In this article, the successes and limitations of biomolecular simulation and the further developments that are likely in the near future are discussed. A brief overview is also provided of the experimental biophysical methods that are commonly used to probe biomolecular structure and dynamics, and the accuracy of the information that can be obtained from each is compared with that from modelling. It is concluded that progress towards an accurate spatial and temporal model of biomacromolecules requires a combination of all of these biophysical techniques, both experimental and computational.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Monitoring of Temperature Rises of Energized Transformer Cores With Distributed Optical Fiber Sensors

Real-time temperature mapping that solves local overheating problems is important for obtaining an optimized thermal design for high-efficiency power transformers. Internal temperature monitoring of operating power transformers can also be leveraged for asset monitoring applications targeting at fault detection enabling condition-based maintenance. Transformers present a variety of challenging sensing environments such as high levels of electromagnetic interference and limited space for conventional sensors to operate. Immersion of power transformers in insulation oils for thermal management during operation and the presence of relatively large and time-varying electrical and occasional magnetic fields make sensing technologies requiring electrical wires or active power at sensing locations highly undesirable. In this work, we investigate thermal response of a standard telecom fiber instrumented on compact transformer cores by using an optical frequency-domain reflectometry scheme. As a result, correlation between conventional temperature sensing methods and fiber-optic sensing results as well as tradeoffs between spatial resolution and temperature measurement accuracy is discussed and spatially resolved real-time monitoring of temperatures in energized transformers is experimentally demonstrated.

24 POWER TRANSMISSION AND DISTRIBUTION↗