Search NASA⌕ Search

SEARCH · Search NASA

Results for “kernel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Nakajima-Zwanzig versus time-convolutionless master equation for the non-Markovian dynamics of a two-level system

We consider the exact reduced dynamics of a two-level system coupled to a bosonic reservoir, further obtaining the exact time-convolutionless and Nakajima-Zwanzig non-Markovian equations of motion. The system considered includes the damped and undamped Jaynes-Cummings model. The result is obtained by exploiting an expression of quantum maps in terms of matrices and a simple relation between the time evolution map and the time-convolutionless generator as well as the Nakajima-Zwanzig memory kernel. This nonperturbative treatment shows that each operator contribution in Lindblad form appearing in the exact time-convolutionless master equation is multiplied by a different time-dependent function. Similarly, in the Nakajima-Zwanzig master equation each such contribution is convoluted with a different memory kernel. It appears that, depending on the state of the environment, the operator structures of the two sets of equations of motion can exhibit important differences.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chiral susceptibility and the scalar Ward identity

The chiral susceptibility is given by the scalar vacuum polarization at zero total momentum. This follows directly from the expression for the vacuum quark condensate so long as a nonperturbative symmetry preserving truncation scheme is employed. For QCD in-vacuum the susceptibility can rigorously be defined via a Pauli-Villars regularization procedure. Owing to the scalar Ward identity, irrespective of the form or Ansatz for the kernel of the gap equation, the consistent scalar vertex at zero total momentum can automatically be obtained and hence the consistent susceptibility. This enables calculation of the chiral susceptibility for markedly different vertex Ansaetze. For the two cases considered, the results were consistent and the minor quantitative differences easily understood. The susceptibility can be used to demarcate the domain of coupling strength within a theory upon which chiral symmetry is dynamically broken. Degenerate massless scalar and pseudoscalar bound-states appear at the critical coupling for dynamical chiral symmetry breaking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integral equation for gauge invariant quark two-point Green's function in QCD

Gauge invariant quark two-point Green's functions defined with path-ordered gluon field phase factors along skew-polygonal lines joining the quark to the antiquark are considered. Functional relations between Green's functions with different numbers of path segments are established. An integral equation is obtained for the Green's function defined with a phase factor along a single straight line. The equation implicates an infinite series of two-point Green's functions, having an increasing number of path segments; the related kernels involve Wilson loops with contours corresponding to the skew-polygonal lines of the accompanying Green's function and with functional derivatives along the sides of the contours. The series can be viewed as an expansion in terms of the global number of the functional derivatives of the Wilson loops. The lowest-order kernel, which involves a Wilson loop with two functional derivatives, provides the framework for an approximate resolution of the equation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamical generation of pseudoscalar resonances

We study the interactions between the f{sub 0}(980) and a{sub 0}(980) scalar resonances and the lightest pseudoscalar mesons. We first obtain the elementary interaction amplitudes, or interacting kernels, without including any ad hoc free parameter. This is achieved by using previous results on the nature of the lightest scalar resonances as dynamically generated from the rescattering of S-wave two-meson pairs. Afterwards, the interaction kernels are unitarized and the final S-wave amplitudes result. We find that these interactions are very rich and generate a large amount of pseudoscalar resonances that could be associated with the K(1460), {pi}(1300), {pi}(1800), {eta}(1475), and X(1835). We also consider the exotic channels with isospin 3/2 and 1, the latter having positive G-parity. The former could also be resonant in agreement with a previous prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

A performance model for GPUs with caches

To exploit the abundant computational power of the world's fastest supercomputers, an even workload distribution to the typically heterogeneous compute devices is necessary. While relatively accurate performance models exist for conventional CPUs, accurate performance estimation models for modern GPUs do not exist. This paper presents two accurate models for modern GPUs: a sampling-based linear model, and a model based on machine-learning (ML) techniques which improves the accuracy of the linear model and is applicable to modern GPUs with and without caches. We first construct the sampling-based linear model to predict the runtime of an arbitrary OpenCL kernel. Based on an analysis of NVIDIA GPUs' scheduling policies we determine the earliest sampling points that allow an accurate estimation. The linear model cannot capture well the significant effects that memory coalescing or caching as implemented in modern GPUs have on performance. We therefore propose a model based on ML techniques that takes several compiler-generated statistics about the kernel as well as the GPU's hardware performance counters as additional inputs to obtain a more accurate runtime performance estimation for modern GPUs. We demonstrate the effectiveness and broad applicability of the model by applying it to three different NVIDIA GPU architectures and one AMD GPU architecture. On an extensive set of OpenCL benchmarks, on average, the proposed model estimates the runtime performance with less than 7 percent error for a second-generation GTX 280 with no on-chip caches and less than 5 percent for the Fermi-based GTX 580 with hardware caches. On the Kepler-based GTX 680, the linear model has an error of less than 10 percent. On an AMD GPU architecture, Radeon HD 6970, the model estimates with 8 percent of error rates. As a result, the proposed technique outperforms existing models by a factor of 5 to 6 in terms of accuracy.

97 MATHEMATICS AND COMPUTING↗

IRIS: A Performance-Portable Framework for Cross-Platform Heterogeneous Computing

From edge to exascale, computer architectures are becoming more heterogeneous and complex. The systems typically have fat nodes, with multicore CPUs and multiple hardware accelerators such as GPUs, FPGAs, and DSPs. This complexity is causing a crisis in programming systems and performance portability. Several programming systems are working to address these challenges, but the increasing architectural diversity is forcing software stacks and applications to be specialized for each architecture. As we show, all of these approaches critically depend on their software framework for discovery, execution, scheduling, and data orchestration. To address this challenge, we believe that a more agile and proactive software framework is essential to increase performance portability and improve user productivity. To this end, we have designed and implemented IRIS: a performance-portable framework for cross-platform heterogeneous computing. IRIS can discover available resources, manage multiple diverse programming platforms (e.g., CUDA, Hexagon, HIP, Level Zero, OpenCL, OpenMP) simultaneously in the same execution, respect data dependencies, orchestrate data movement proactively, and provide for user-configurable scheduling. To simplify data movement, IRIS introduces a shared virtual device memory with relaxed consistency among different heterogeneous devices. IRIS also adds an automatic kernel workload partitioning technique using the polyhedral model so that it can resize kernels for a wide range of devices. Our evaluation on three architectures, ranging from Qualcomm Snapdragon to a Summit supercomputer node, shows that IRIS improves portability across a wide range of diverse heterogeneous architectures with negligible overhead.

97 MATHEMATICS AND COMPUTING↗

Distributed Data-Driven Optimization for Voltage Regulation in Distribution Systems

Here, this paper proposes a distributed data-driven optimization framework for voltage regulation in distribution systems. The recursive kernel regression and alternating direction method of multipliers (ADMM) are selected to cover the system learning and distributed optimization tasks. The proposed distributed data-driven framework is capable of having a rapid response to system or load changes while considering the operation optimality. Besides, the distributed algorithm parallels the computation tasks and reduces the computational expense of a single agent. To validate the performance of the proposed method, a hypothetical 7-Bus system and the IEEE 123-Bus system are selected to show the effectiveness of the proposed data-driven framework. According to the numerical study results, the proposed method offers great flexibility for selecting customized kernel models for different regions and can effectively improve the system voltage profile in a distributed manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantification of arterial plaque and lumen density with MDCT

Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-{mu}{sup *}d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c{sup *}exp(-a{sup *}d{sup b}) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density {rho} (g/cm{sup 3}). This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A general framework and review of scatter correction methods in cone beam CT. Part 2: Scatter estimation approaches

The main components of scatter correction procedures are scatter estimation and a scatter compensation algorithm. This paper completes a previous paper where a general framework for scatter compensation was presented under the prerequisite that a scatter estimation method is already available. In the current paper, the authors give a systematic review of the variety of scatter estimation approaches. Scatter estimation methods are based on measurements, mathematical-physical models, or combinations of both. For completeness they present an overview of measurement-based methods, but the main topic is the theoretically more demanding models, as analytical, Monte-Carlo, and hybrid models. Further classifications are 3D image-based and 2D projection-based approaches. The authors present a system-theoretic framework, which allows to proceed top-down from a general 3D formulation, by successive approximations, to efficient 2D approaches. A widely useful method is the beam-scatter-kernel superposition approach. Together with the review of standard methods, the authors discuss their limitations and how to take into account the issues of object dependency, spatial variance, deformation of scatter kernels, external and internal absorbers. Open questions for further investigations are indicated. Finally, the authors refer on some special issues and applications, such as bow-tie filter, offset detector, truncated data, and dual-source CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-439: An Improved Formula of Scatter-To-Primary Ratio for Photon Dose Calculation

Purpose: Scatter-to-primary ratio (SPR) is an important dosimetric quantity that describes the contribution from the scatter photons in an external photon beam. The purpose of this study is to develop an improved analytical formula to describe SPR as a function of circular field size (r) and depth (d) using Monte Carlo (MC) simulation. Methods: MC simulation was performed for Mohan photon spectra (Co-60, 4, 6, 10, 15, 23 MV) using EGSNRC code. Point-spread scatter dose kernels in water are generated. The scatter-to-primary ratio (SPR) is also calculated using MC simulation as a function of field size for circular field size with radius r and depth d. The doses from forward scatter and backscatter photons are calculated using a convolution of the point-spread scatter dose kernel and by accounting for scatter photons contributing to dose before (z' d) reaching the depth of interest, d, where z' is the location of scatter photons, respectively. The depth dependence of the ratio of the forward scatter and backscatter doses is determined as a function of depth and field size. Results: We are able to improve the existing 3-parameter (a, w, d0) empirical formula for SPR by introducing depth dependence for one of the parameter d0, which becomes 0 for deeper depths. The depth dependence of d0 can be directly calculated as a ratio of backscatter-to-forward scatter doses for otherwise the same field and depth. With the improved empirical formula, we can fit SPR for all megavoltage photon beams to within 2%. Existing 3-parameter formula cannot fit SPR data for Co-60 to better than 3.1%. Conclusion: An improved empirical formula is developed to fit SPR for all megavoltage photon energies to within 2%.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-06: Inverse Planning of Gamma Knife Radiosurgery Using Natural Physical Models

Purpose: Treatment-planning systems rely on computer intensive optimization algorithms in order to provide radiation dose localization. We are investigating a new optimization paradigm based on natural physical modeling and simulations, which tend to evolve in time and find the minimum energy state. In our research, we aim to match physical models with radiation therapy inverse planning problems, where the minimum energy state coincides with the optimal solution. As a prototype study, we have modeled the inverse planning of Gamma Knife radiosurgery using the dynamic interactions between charged particles and demonstrate the potential of the paradigm. Methods: For inverse planning of Gamma Knife radiosurgery: (1) positive charges are uniformly placed on the surface of tumors and critical structures. (2) The Gamma Knife dose kernels of 4mm, 8mm and 16mm radii are modeled as geometric objects with variable charges. (3) The number of shots per each kernel radii is obtained by solving a constrained integer-linear problem. (4) The shots are placed into the tumor volume and move under electrostatic forces. The simulation is performed until internal forces are zero or maximum iterations are reached. (5) Finally, non-negative least squares (NNLS) is used to calculate the beam-on times for each shot. Results: A 3D C-shaped tumor surrounding a spherical critical structure was used for testing the new optimization paradigm. These tests showed that charges spread out evenly covering the tumor while keeping distance from the critical structure, resulting in a high quality plan. Conclusion: We have developed a new paradigm for dose optimization based on the simulation of physical models. As prototype studies, we applied electrostatic models to Gamma Knife radiosurgery and demonstrated the potential of the new paradigm. Further research and fine-tuning of the model are underway. NSF CBET-0853157.

60 APPLIED LIFE SCIENCES↗

SU-E-T-265: Development of Dose-To-Water Conversion Models for Pre-Treatment Verification with the New AS1200 Imager

Purpose: To develop and evaluate models for dose verification of flattened (FF) and flattening filter free (FFF) beams for the new Varian aS1200 backscatter-shielded electronic portal imaging device (EPID). Methods: The model converts EPID images to incident energy fluence using deconvolution of EPID scatter kernels and fluence to dose in water using convolution with dose-to-water kernels. Model parameters were optimized using non-transmission EPID images of varying jaw defined field sizes for energies of 6 and 10 MV FF and FFF beams. Energy fluence was obtained from the Acuros planning system and reference dose profiles and output factors were measured at depths of 5, 10, 15 and 20 cm in a water phantom. Images for 34 IMRT fields acquired at 6 and 10 MV FF energy were converted to dose at 10 cm depth in water and compared to treatment planning system dose plane calculations using gamma criteria. Results: Gamma evaluations for the IMRT fields had mean (1 standard deviation) pass rates of 99.4% (0.8%) and mean gamma scores of 0.32 (0.06) with 2%, 2 mm criteria and 10% of maximum dose threshold. Conclusion: The developed model has been shown to be highly accurate for pre-treatment verification with the new aS1200 imager which does not display support-arm backscatter artefact and has improved dosimetric properties. Further investigation of FFF modes is in progress. The model is currently being evaluated at sites for potential clinical release.

60 APPLIED LIFE SCIENCES↗

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-10: Effect of CT Reconstruction Filter On Measured Hounsfield Values in Lung Nodules

Purpose: Measured Hounsfield numbers in CT are used by radiologists to determine the presence of calcium or fat in lung nodules, either of which suggests a benign diagnosis. However, substantial variations in Hounsfield number may arise due to the use of different reconstruction parameters such as the filter/kernel, leading to measurement inaccuracies. This quality improvement project was developed to demonstrate measurement pitfalls and to identify acceptable conditions for incorporating Hounsfield values as a factor in lung nodule diagnosis. Methods: 12 mm-diameter spheres of polyurethane and urethane foam were placed into an anthropomorphic chest phantom, and 10 mm-diameter tubes with varying iodine concentrations were placed into a 16 cm PMMA cylindrical phantom. Additionally, 11 mm-diameter PMMA and HDPE spheres were placed in a 10 cm PMMA cylindrical phantom. Phantoms were scanned at 120 kVp using a Siemens Biograph mCT and on a Philips iCT and reconstructed using various reconstruction filters. Results: For the Siemens system, both sharp kernels and smooth kernels altered the Hounsfield numbers. Hounsfield numbers varied within a range of 8.9 HU for urethane foam and varied within 58.7 HU for polyurethane. The iodine measurements varied up to 37.9 HU for the lowest concentration. For the Philips system, Hounsfield numbers were relatively consistent but were higher for the “Detail” and “Lung Enhanced” filters, varying by 36.9 HU for PMMA and 15.9 HU for HDPE. Conclusion: Reconstruction filters can change the measured Hounsfield numbers of nodular objects, especially with detail-enhancing (sharpening) filters commonly used in lung imaging. Measured values should only be used for diagnostic decision support with filters that have demonstrated accuracy and consistency. While filter accuracy statements are available from manufacturers, radiologists are likely not aware of the extent of potential variations that can occur in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Small-x evolution in the next-to-leading order

After a brief introduction to Deep Inelastic Scattering in the Bjorken limit and in the Regge Limit we discuss the operator product expansion in terms of non local string operator and in terms of Wilson lines. We will show how the high-energy behavior of amplitudes in gauge theories can be reformulated in terms of the evolution of Wilson-line operators. In the leading order this evolution is governed by the non-linear Balitsky-Kovchegov (BK) equation. In order to see if this equation is relevant for existing or future deep inelastic scattering (DIS) accelerators (like Electron Ion Collider (EIC) or Large Hadron electron Collider (LHeC)) one needs to know the next-to-leading order (NLO) corrections. In addition, the NLO corrections define the scale of the running-coupling constant in the BK equation and therefore determine the magnitude of the leading-order cross sections. In Quantum Chromodynamics (QCD), the next-to-leading order BK equation has both conformal and non-conformal parts. The NLO kernel for the composite operators resolves in a sum of the conformal part and the running-coupling part. The QCD and kernel of the BK equation is presented.

43 PARTICLE ACCELERATORS↗