Search NASA⌕ Search

SEARCH · Search NASA

Results for “level set method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Leading Edge Erosion Classification System

The leading edge erosion of wind turbine blades is a common issue that can have a range of implications for the operation and maintenance of the turbine. A variety of methods have attempted to determine the severity of erosion damage, applied in different academic, testing and in-situ settings. This paper describes the current state of the art in categorization, and the individual drivers in assessment. From this foundation, the IEA Wind Task 46 WP3 group collated key considerations from the process of categorizing erosion damage and a proposed erosion classification system was put forward. Trial assessments were performed using the initial system, which led to adjustments to the original proposition. The refined system defines discrete severity levels that concern the wind turbine blade: (1) Visual Condition (concerning blades with/without leading edge protection); (2) Mass Loss; (3) Aerodynamic Performance; and (4) Structural Integrity. The classification system presented is not intended to be a fixed entity. The Task 46 group has already identified specific challenges and opportunities that are applicable to individual use and the overall wind energy industry. The intention is for the system to evolve as improvements are identified, technology improves, and work progresses through other Task 46 activities. Several considerations and recommendations are discussed that could be applicable for future implementation of the system.

17 WIND ENERGY↗

SIMULATED HUMAN ERROR PROBABILITY AND ITS APPLICATION TO DYNAMIC HUMAN FAILURE EVENTS

Abstract Objectives: Human reliability analysis (HRA) methods typically analyze human failure events (HFEs) at the overall task level. For dynamic HRA, it is important to model human activities at the subtask level. There exists a disconnect between dynamic subtask level and static task level that presents issues when modeling dynamic scenarios. For example, the SPAR-H method is typically used to calculate the human error probability (HEP) at the task level. As demonstrated in this paper, quantification in SPAR-H does not translate to the subtask level. Methods: Two different discrete distributions were generated for each SPAR-H Performance Shaping Factor (PSF) to define the frequency of PSF levels. The first distribution was a uniform, or uninformed distribution that assumed the frequency of each PSF level was equally likely. The second non-continuous distribution took the frequency of PSF level as identified from an assessment of the HERA database. These two different approaches were created to identify the resulting distribution of the HEP. The resulting HEP that appears closer to the known distribution, a log-normal centered on 1E-3, is the more desirable. Each approach then has median, average and maximum HFE calculations applied. To calculate these three values, three events, A, B and C are generated from the PSF level frequencies comprised of subtasks. The median HFE selects the median PSF level from each PSF and calculates HEP. The average HFE takes the mean PSF level, and the maximum takes the maximum PSF level. The same data set of subtask HEPs yields starkly different HEPs when aggregated to the HFE level in SPAR-H. Results: Assuming that each PSF level in each HFE is equally likely creates an unrealistic distribution of the HEP that is centered at 1. Next the observed frequency of PSF levels was applied with the resulting HEP behaving log-normally with a majority of the values under 2.5% HEP. The median, average and maximum HFE calculations did yield different answers for the HFE. The HFE maximum grossly over estimates the HFE, while the HFE distribution occurs less than HFE median, and greater than HFE average. Conclusions: Dynamic task modeling can be perused through the framework of SPAR-H. Identification of distributions associated with each PSF needs to be defined, and may change depending upon the scenario. However it is very unlikely that each PSF level is equally likely as the resulting HEP distribution is strongly centered at 100%, which is unrealistic. Other distributions may need to be identified for PSFs, to facilitate the transition to dynamic task modeling. Additionally discrete distributions need to be exchanged for continuous so that simulations for the HFE can further advance. This paper provides a method to explore dynamic subtask to task translation and provides examples of the process using the SPAR-H method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building-Level Comparison of Microsoft and Google Open Building Footprints Datasets

Large-scale datasets of building footprints are a crucial source of information for a variety of efforts. In 2023, the general public benefits from open access to multiple sources of building footprints at the country scale or larger, such as those produced by Microsoft and Google. However, none of the available datasets have attained complete global coverage, and researchers and analysts may need to combine multiple sources to assemble a complete set of building footprints for their area of interest or choose between overlapping sources, requiring an understanding of the differences between different building sources. This paper presents a method to closely examine the quality of different building footprint sources by matching corresponding buildings across datasets, using building footprints in Ethiopia published by Microsoft and Google as an example set.

Gonzales, Jack↗

A Regularized Variance-Reduced Modified Extragradient Method for Stochastic Hierarchical Games

We consider an N -player hierarchical game in which the i th player’s objective comprises of an expectation-valued term, parametrized by rival decisions, and a hierarchical term. Such a framework allows for capturing a broad range of stochastic hierarchical optimization problems, Stackelberg equilibrium problems, and leader-follower games. We develop an iteratively regularized and smoothed variance-reduced modified extragradient framework for iteratively approaching hierarchical equilibria in a stochastic setting. We equip our analysis with rate statements, complexity guarantees, and almost-sure convergence results. We then extend these statements to settings where the lower-level problem is solved inexactly and provide the corresponding rate and complexity statements. Our model framework encompasses many game theoretic equilibrium problems studied in the context of power markets. We present a realistic application to the study of virtual power plants, emphasizing the role of hierarchical decision making and regularization. Preliminary numerics suggest that empirical behavior compares well with theoretical guarantees.

Tikhonov regularization↗

A large-scale analysis of bioinformatics code on GitHub

In recent years, the explosion of genomic data and bioinformatic tools has been accompanied by a growing conversation around reproducibility of results and usability of software. However, the actual state of the body of bioinformatics software remains largely unknown. Here, the purpose of this paper is to investigate the state of source code in the bioinformatics community, specifically looking at relationships between code properties, development activity, developer communities, and software impact. To investigate these issues, we curated a list of 1,720 bioinformatics repositories on GitHub through their mention in peer-reviewed bioinformatics articles. Additionally, we included 23 high-profile repositories identified by their popularity in an online bioinformatics forum. We analyzed repository metadata, source code, development activity, and team dynamics using data made available publicly through the GitHub API, as well as article metadata. We found key relationships within our dataset, including: certain scientific topics are associated with more active code development and higher community interest in the repository; most of the code in the main dataset is written in dynamically typed languages, while most of the code in the high-profile set is statically typed; developer team size is associated with community engagement and high-profile repositories have larger teams; the proportion of female contributors decreases for high-profile repositories and with seniority level in author lists; and, multiple measures of project impact are associated with the simple variable of whether the code was modified at all after paper publication. In addition to providing the first large-scale analysis of bioinformatics code to our knowledge, our work will enable future analysis through publicly available data, code, and methods.

97 MATHEMATICS AND COMPUTING↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

Radar Derived Rainfall and Rain Gauge Measurements at SRS

Over the years rainfall data for the Savannah River Site has been obtained from ground level measurements made by rain gauges. These instruments have inherent errors or biases that can impact the measured rainfall totals but are assumed as ground truth for most climatological and weather applications. With the development of weather radar technologies, various methods to derive rainfall totals from radar reflectivity values have been developed and have continued to improve. The Z-R relationship, which uses an exponential relationship to estimate rainfall rate based on radar reflectivity values, provides estimates of rainfall amounts (Z-R Level III) for locations within the radar’s detection range. The recently developed Multi-Radar Multi-Sensor (MRMS) dataset combines reflectivity-based estimates using the Z-R relationship with a network of gauges and other rainfall estimates to produce a refined set of precipitation estimates for each grid point within its domain. Comparisons were done between gauge observations and radar estimates for various SRS locations to assess whether radar derived estimates are representative of rainfall measurements at the site. Results obtained show good agreement between radar derived amounts and ground measurements, with MRMS showing stronger correlations and lower spread than Z-R Level III estimates. Outliers and errors observed appear to be related to hydrometeor classification schemes. In general, MRMS proved to provide sufficiently representative estimates of daily rainfall amounts to replace existing SRS rain gauge measurements.

54 ENVIRONMENTAL SCIENCES↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

Robust Network Interdiction Considering Multiple Defense Resources

We extend the network interdiction problem in order to consider multiple options for defending arcs in a network. We apply our model to select an optimal set of countermeasures for nuclear material smuggling. In order account for the joint impact of multiple countermeasures, we consider multiple components of defense: situational awareness, detection, and interdiction. We develop a bi-level programming model, where the adversary's goal is to maximize damage to the system while the defender seeks to minimize damage by selecting countermeasure options under a restricted bud- get. Furthermore, since effectiveness of countermeasures is often difficult to assess with high accuracy, we use robust optimization to allow for parametric uncertainty. We test our method on a synthetic example of the U.S. supply chain network that includes rail, air, and maritime transportation between both domestic and international locations. For this test example, we find that increasing the budget for countermeasures has the greatest impact within the first 1-2% of the cost to implement all countermeasures and that the uncertainty tolerance has a greater impact on expected damage than the countermeasure budget does. Thus, when strategically selecting countermeasures it is important to precisely understand the effectiveness of each option and the adversary's probability of subverting them.

97 MATHEMATICS AND COMPUTING↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, SeyedMohammad↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, Seyed Mohammad↗

LDRD Report : Analysis of Defect Clustering in Semiconductors using Kinetic Monte Carlo Methods

The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. Neutron irradiation can instigate the formation of quasi-stable defect structures, thereby introducing new energy levels into the bandgap that alter carrier lifetimes and give rise to such phenomena as gain degradation in bipolar junction transistors. Typically, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. A kinetic Monte Carlo (KMC) code has been developed to model both thermal and carrier injection annealing of initial defect structures in semiconductor materials. Following the development of a set of verification tests, the code is employed to investigate annealing in electron-irradiated, p-type silicon as well as the recovery of base current in silicon transistors bombarded with neutrons at the Los Alamos LANSCE "Blue Room" facility. The results reveal that KMC calculations agree well with experiment once adjustments are made to significant defect parameters within the appropriate uncertainty bounds.

36 MATERIALS SCIENCE↗

A framework for quantifying the impact of occupant behavior on energy savings of energy conservation measures

To improve energy efficiency—during new buildings design or during a building retrofit—evaluating the energy savings potential of energy conservation measures (ECMs) is a critical task. In building retrofits, occupant behavior significantly impacts building energy use and is a leading factor in uncertainty when determining the effectiveness of retrofit ECMs. Current simulation-based assessment methods simplify the representation of occupant behavior by using a standard or representative set of static and homogeneous assumptions ignoring the dynamics, stochastics, and diversity of occupant's energy-related behavior in buildings. The simplification contributes to significant gaps between the simulated and measured actual energy performance of buildings. This paper presents a framework for quantifying the impact of occupant behaviors on ECM energy savings using building performance simulation. During the first step of the study, three occupant behavior styles (austerity, normal, and wasteful) were defined to represent different levels of energy consciousness of occupants regarding their interactions with building energy systems (HVAC, windows, lights and plug-in equipment). Next, a simulation workflow was introduced to determine a range of the ECM energy savings. Then, guidance was provided to interpret the range of ECM savings to support ECM decision making. Finally, a pilot study was performed in a real building to demonstrate the application of the framework. Simulation results show that the impact of occupant behaviors on ECM savings vary with the type of ECM. Occupant behavior minimally affects energy savings for ECMs that are technology-driven (the relative savings differ by less than 2%) and have little interaction with the occupants; for ECMs with strong occupant interaction, such as the use of zonal control variable refrigerant flow system and natural ventilation, energy savings are significantly affected by occupant behavior (the relative savings differ by up to 20%). Finally, the study framework provides a novel, holistic approach to assessing the uncertainty of ECM energy savings related to occupant behavior, enabling stakeholders to understand and assess the risk of adopting energy efficiency technologies for new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Association of short-term exposure to ground-level ozone and respiratory outpatient clinic visits in a rural location – Sublette County, Wyoming, 2008–2011

Objective: Short-term exposure to ground-level ozone has been linked to adverse respiratory and other health effects; previous studies typically have focused on summer ground-level ozone in urban areas. During 2008–2011, Sublette County, Wyoming (population: ~10,000 persons), experienced periods of elevated ground-level ozone concentrations during the winter. This study sought to evaluate the association of daily ground-level ozone concentrations and health clinic visits for respiratory disease in this rural county. Methods: Clinic visits for respiratory disease were ascertained from electronic billing records of the two clinics in Sublette County for January 1, 2008–December 31, 2011. A time-stratified case-crossover design, adjusted for temperature and humidity, was used to investigate associations between ground-level ozone concentrations measured at one station and clinic visits for a respiratory health concern by using an unconstrained distributed lag of 0–3 days and single-day lags of 0 day, 1 day, 2 days, and 3 days. Results: The data set included 12,742 case-days and 43,285 selected control-days. The mean ground-level ozone observed was 47±8 ppb. The unconstrained distributed lag of 0–3 days was consistent with a null association (adjusted odds ratio [aOR]: 1.001; 95% confidence interval [CI]: 0.990–1.012); results for lags 0, 2, and 3 days were consistent with the null. However, the results for lag 1 were indicative of a positive association; for every 10-ppb increase in the 8-h maximum average ground-level ozone, a 3.0% increase in respiratory clinic visits the following day was observed (aOR: 1.031; 95% CI: 0.994–1.069). Season modified the adverse respiratory effects: ground-level ozone was significantly associated with respiratory clinic visits during the winter months. The patterns of results from all sensitivity analyzes were consistent with the a priori model. Conclusions: The results demonstrate an association of increasing ground-level ozone with an increase in clinic visits for adverse respiratory-related effects in the following day (lag day 1) in Sublette County; the magnitude was strongest during the winter months; this association during the winter months in a rural location warrants further investigation. - Highlights: • We assessed elevated ground-level ozone in frontier Sublette County, Wyoming. • Ground-level ozone concentrations were moderately to highly correlated between stations. • Adverse respiratory-related clinic visits occurred year round at lag 1. • Strongest association of clinic visits was in the coldest months at lag 1.

54 ENVIRONMENTAL SCIENCES↗

Deep levels generated by thermal oxidation in p-type 4H-SiC

Thermal oxidation is an effective method to reduce deep levels, especially the Z{sub 1/2}-center (E{sub C}-0.67 eV), which strongly suppresses carrier lifetimes in n-type 4H-SiC epilayers. The oxidation, however, simultaneously generates other deep levels, HK0 (E{sub V}+0.79 eV) and HK2 (E{sub V}+0.98 eV) centers, within the lower half of the bandgap of SiC, where the HK0 center is a dominant deep level with a concentration of about 1 Multiplication-Sign 10{sup 13} cm{sup -3} after oxidation. By comparing deep levels observed in three sets of p-type 4H-SiC: oxidized, electron-irradiated, and C{sup +}- or Si{sup +}-implanted samples, we find that the HK0 and HK2 centers are complexes including carbon interstitials such as the di-carbon interstitial or di-carbon antisite. Other defects observed in p-type 4H-SiC after electron irradiation or after C{sup +}/Si{sup +} implantation are also studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-18C-04: A Combination of Monoenergetic Reconstruction and Stoichiometric Calibration for Tissue Characterization Using Dual Energy Computed Tomography

Purpose: Dual energy computed tomography (DECT) pre-reconstruction methods require the prior knowledge of the X-ray source spectrum to allow extracting physical parameters needed for radiation therapy dose calculation, such as electron density (ED) and the effective atomic number (EAN). While DECT stoichiometric calibration may provide reliable performance for typical radiation therapy clinical conditions, it is yet to be adapted to prereconstruction methods. The presence of noise and inaccurate spectrum description may lead to systematic errors and artifacts which compromise the accuracy of treatment planning. Methods: A new technique is investigated which consists in applying a DECT stoichiometric calibration method to a set of monoenergetic images obtained with a DECT prereconstruction method. To evaluate the performance of this extended method, a simulation environment is developed to generate DECT scans under well controlled conditions, to reconstruct monoenergetic images of a tissue-equivalent phantom from transformed sinograms and to extract ED and EAN maps using a DECT formalism. Result: Under simulated clinical conditions, the accuracy in determining ED with the extended method versus a pre-reconstruction method alone is shown to be better than 0.35% versus 0.5%, respectively. In the presence of a realistic noise level, EAN determination presents a relative mean error that drops from 2.5% to 0.5% once the calibration is applied. Considering a spectrum alteration by a 1 mm Cu layer, EAN errors are up to 30% for the pre-reconstruction method alone versus less than 3% for the extended method. Conclusion: This study shows that combining pre-reconstruction DECT methods with a stoichiometric calibration considerably improves the accuracy and reliability of tissue characterization for radiation therapy in a clinical context. The presented method could potentially be adapted as gold standard for dose calculation methods based on DECT.

07 ISOTOPE AND RADIATION SOURCES↗