Search NASA⌕ Search

SEARCH · Search NASA

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

HDO INFRARED DETECTION SENSITIVITY AND D/H ISOTOPIC EXCHANGE IN AMORPHOUS AND CRYSTALLINE ICE

The sensitivity of the OD stretching band as a probe to detect HDO in astrophysical ice is discussed based on IR laboratory spectra of HDO molecules embedded in H{sub 2}O ice. This band is extremely broad and tends to disappear into the absorption continuum of H{sub 2}O for low-temperature amorphous samples. Detectable HDO/H{sub 2}O ratios with this technique may range from a few percent for amorphous samples to a few per thousand in crystalline ice. These relatively high upper limits and the appreciable dependence of the band shape on temperature, which would complicate the interpretation of data from many lines of sight, decisively limit the usefulness of the technique for HDO detection in astronomical observations. The process of isotopic H/D exchange in mixed ice of H{sub 2}O/D{sub 2}O is also studied through the evolution of the OD band in IR spectra. Isotopic exchange starts at {approx}120 K and is greatly accelerated at 150 K, as crystallization proceeds in the ice. Annealed amorphous samples prove to be more favorable for isotope exchange than samples directly formed in crystalline phase. The annealing process seems to favor a polycrystalline ice morphology with a higher defect activity. These morphology differences can be of relevance for deuterium fractionation in astronomical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spectral reflectance estimation technique using multispectral data from the Viking lander camera

A technique is formulated for constructing spectral reflectance curve estimates from multispectral data obtained with the Viking lander camera. The multispectral data are limited to six spectral channels in the wavelength range from 0.4 to 1.1 micrometers and most of these channels exhibit appreciable out-of-band response. The output of each channel is expressed as a linear (integral) function of the (known) solar irradiance, atmospheric transmittance, and camera spectral responsivity and the (unknown) spectral responsivity and the (unknown) spectral reflectance. This produces six equations which are used to determine the coefficients in a representation of the spectral reflectance as a linear combination of known basis functions. Natural cubic spline reflectance estimates are produced for a variety of materials that can be reasonably expected to occur on Mars. In each case the dominant reflectance features are accurately reproduced, but small period features are lost due to the limited number of channels. This technique may be a valuable aid in selecting the number of spectral channels and their responsivity shapes when designing a multispectral imaging system.

Park, S. K.↗

Image restoration and superresolution as probes of small scale far-IR structure in star forming regions

Far-infrared continuum studies from the Kuiper Airborne Observatory are described that are designed to fully exploit the small-scale spatial information that this facility can provide. This work gives the clearest picture to data on the structure of galactic and extragalactic star forming regions in the far infrared. Work is presently being done with slit scans taken simultaneously at 50 and 100 microns, yielding one-dimensional data. Scans of sources in different directions have been used to get certain information on two dimensional structure. Planned work with linear arrays will allow us to generalize our techniques to two dimensional image restoration. For faint sources, spatial information at the diffraction limit of the telescope is obtained, while for brighter sources, nonlinear deconvolution techniques have allowed us to improve over the diffraction limit by as much as a factor of four. Information on the details of the color temperature distribution is derived as well. This is made possible by the accuracy with which the instrumental point-source profile (PSP) is determined at both wavelengths. While these two PSPs are different, data at different wavelengths can be compared by proper spatial filtering. Considerable effort has been devoted to implementing deconvolution algorithms. Nonlinear deconvolution methods offer the potential of superresolution -- that is, inference of power at spatial frequencies that exceed D lambda. This potential is made possible by the implicit assumption by the algorithm of positivity of the deconvolved data, a universally justifiable constraint for photon processes. We have tested two nonlinear deconvolution algorithms on our data; the Richardson-Lucy (R-L) method and the Maximum Entropy Method (MEM). The limits of image deconvolution techniques for achieving spatial resolution are addressed.

Lester, D. F.↗

Stability Of Nanoclusters In 14YWT Oxide Dispersion Strengthened Steel Under Heavy Ion-irradiation By Atom Probe Tomography

14YWT oxide dispersion strengthened (ODS) ferritic steel was irradiated with of 5 MeV Ni2+ ions, at 300 °C, 450 °C, and 600 °C to a damage level of 100 dpa. The stability of Ti–Y–O nanoclusters was investigated by applying atom probe tomography (APT) in voltage mode, of the samples before and after irradiations. The average size and number density of the nanoclusters was determined using the maximum separation method. These techniques allowed for the imaging of nanoclusters to sizes well below the resolution limit of conventional transmission electron microscopy techniques. The most significant changes were observed for samples irradiated at 300 °C where the size (average Guinier radius) and number density of nanoclusters were observed to decrease from 1.1 nm to 0.8 nm and 12 × 1023 to 3.6 × 1023, respectively. In this study, the nanoclusters are more stable at higher temperature.

Environmental Molecular Sciences Laboratory↗

Mitigating Transition in the Fermilab Booster Using a Triple Phase Jump

The PIP-II project will significantly enhance neutrino production for DUNE, Fermilab’s flagship long-baseline neutrino oscillation experiment, by doubling the beam power delivered by the accelerator complex. To achieve this, the total charge injected from the new PIP-II linac into the Booster rapid cycling synchrotron (RCS) will increase from $4.5\times 10^{12}$ to $6.5\times 10^{12}$ protons per pulse. Simultaneously, the Booster’s ramp rate will rise from 15 to 20 Hz, while the injection energy will go from 400 MeV to 800 MeV. The Booster accelerates the beam to 8 GeV and crosses transition at $\gamma_t=5.45$. In current operations, no dedicated $\gamma_t$ jump system is employed; instead, longitudinal emittance growth is controlled via an active quadrupole-mode feedback system. Downstream, the Recycler Ring uses slip-stacking to accumulate beam and increase bunch intensity. However, this process imposes a constraint on the longitudinal emittance at Booster extraction, limiting it to 0.1 eV-s (95\%) to avoid excessive particle loss. Because collective effects scale with intensity, additional measures to mitigate transition crossing may be required to stay below this limit. One potential approach is the so-called triple phase-jump technique. While the method has known limitations, it offers some advantages: it can be implemented using the existing digital low-level RF (LLRF) system, requires no additional magnets or pulsed power supplies, and remains compatible with quadrupole-mode feedback.

Ostiguy, J.-F. [Fermilab] (ORCID:0000000290883681)↗

Mitigating Transition in the Fermilab Booster Using a Triple Phase Jump

The PIP-II project will significantly enhance neutrino production for DUNE, Fermilab s flagship long-baseline neutrino oscillation experiment, by doubling the beam power delivered by the accelerator complex. To achieve this, the total charge injected from the new PIP-II linac into the Booster rapid cycling synchrotron (RCS) will increase from $4.5\times 10^{12}$ to $6.5\times 10^{12}$ protons per pulse. Simultaneously, the Booster s ramp rate will rise from 15 to 20 Hz, while the injection energy will go from 400 MeV to 800 MeV. The Booster accelerates the beam to 8 GeV and crosses transition at $\gamma_t=5.45$. In current operations, no dedicated $\gamma_t$ jump system is employed; instead, longitudinal emittance growth is controlled via an active quadrupole-mode feedback system. Downstream, the Recycler Ring uses slip-stacking to accumulate beam and increase bunch intensity. However, this process imposes a constraint on the longitudinal emittance at Booster extraction, limiting it to 0.1 eV-s (95\%) to avoid excessive particle loss. Because collective effects scale with intensity, additional measures to mitigate transition crossing may be required to stay below this limit. One potential approach is the so-called triple phase-jump technique. While the method has known limitations, it offers some advantages: it can be implemented using the existing digital low-level RF (LLRF) system, requires no additional magnets or pulsed power supplies, and remains compatible with quadrupole-mode feedback.

Ostiguy, Jean-Francois [Fermilab] (ORCID:000000029↗

Quantitative Image Analysis Techniques with High-Speed Schlieren Photography

Optical flow visualization techniques such as schlieren and shadowgraph photography are essential to understanding fluid flow when interpreting acquired wind tunnel test data. Output of the standard implementations of these visualization techniques in test facilities are often limited only to qualitative interpretation of the resulting images. Although various quantitative optical techniques have been developed, these techniques often require special equipment or are focused on obtaining very precise and accurate data about the visualized flow. These systems are not practical in small, production wind tunnel test facilities. However, high-speed photography capability has become a common upgrade to many test facilities in order to better capture images of unsteady flow phenomena such as oscillating shocks and flow separation. This paper describes novel techniques utilized by the authors to analyze captured high-speed schlieren and shadowgraph imagery from wind tunnel testing for quantification of observed unsteady flow frequency content. Such techniques have applications in parametric geometry studies and in small facilities where more specialized equipment may not be available.

Pollard, Victoria J.↗

Stability of nanoclusters in 14YWT oxide dispersion strengthened steel under heavy ion-irradiation by atom probe tomography

14YWT oxide dispersion strengthened (ODS) ferritic steel was irradiated with of 5 MeV Ni2+ ions, at 300 C, 450 C, and 600 C to a damage level of 100 dpa. The stability of Ti–Y–O nanoclusters was investigated by applying atom probe tomography (APT) in voltage mode, of the samples before and after irradiations. The average size and number density of the nanoclusters was determined using the maximum separation method. These techniques allowed for the imaging of nanoclusters to sizes well below the resolution limit of conventional transmission electron microscopy techniques. The most significant changes were observed for samples irradiated at 300 C where the size (average Guinier radius) and number density of nanoclusters were observed to decrease from 1.1 nm to 0.8 nm and 12 1023 to 3.6 1023, respectively. In this study, the nanoclusters are more stable at higher temperature.

99 GENERAL AND MISCELLANEOUS↗

Radiographic detectability limits for seeded voids in sintered silicon carbide and silicon nitride

Conventional and microfocus X-radiographic techniques were compared to determine relative detectability limits for voids in green and sintered SiC and Si3N4. The relative sensitivity of the techniques was evaluated by comparing their ability to detect voids that were artificially introduced by a seeding process. For projection microfocus radiography the sensitivity of void detection at a 90/95 probability of detection/confidence level is 1.5% of specimen thickness in sintered SiC and Si3N4. For conventional contact radiography the sensitivity is 2.5% of specimen thickness. It appears that microfocus projection radiography is preferable to conventional contact radiography in cases where increased sensitivity is required and where the additional complexity of the technique can be tolerated.

Baaklini, G. Y.↗

Radiographic detectability limits for seeded voids in sintered silicon carbide and silicon nitride

Conventional and microfocus X-radiographic techniques were compared to determine relative detectability limits for voids in green and sintered SiC and Si3N4. The relative sensitivity of the techniques was evaluated by comparing their ability to detect voids that were artificially introduced by a seeding process. For projection microfocus radiography the sensitivity of void detection at a 90/95 probability of detection/confidence level is 1.5 percent of specimen thickness in sintered SiC and Si3N4. For conventional contact radiography the sensitivity is 2.5 percent of specimen thickness. It appears that microfocus projection radiography is preferable to conventional contact radiography in cases where increased sensitivity is required and where the additional complexity of the technique can be tolerated.

Baaklini, G. Y.↗

New approaches for metabolomics by mass spectrometry

Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray ionization (LAESI), for metabolite profiling of functioning cells and tissues. The technique was based on microscopic sampling of biological specimens by mid-infrared laser ablation followed by electrospray ionization of the plume and MS analysis. The two main shortcomings of this technique had been limited specificity due to the lack of a separation step, and limited molecular coverage, especially for nonpolar chemical species. To improve specificity and the coverage of the metabolome, we implemented the LAESI ion source on a mass spectrometer with ion mobility separation (IMS). In this system, the gas phase ions produced by the LAESI source were first sorted according to their collisional cross sections in a mobility cell. These separated ion packets were then subjected to MS analysis. By combining the atmospheric pressure ionization with IMS, we improved the metabolite coverage. Further enhancement of the non-polar metabolite coverage resulted from the combination of laser ablation with vacuum UV irradiation of the ablation plume. Our results indicated that this new ionization modality provided improved detection for neutral and non-polar compounds. Based on rapid progress in photonics, we had introduced another novel ion source that utilized the interaction of a laser pulse with silicon nanopost arrays (NAPA). In these nanophotonic ion sources, the structural features were commensurate with the wavelength of the laser light. The enhanced interaction resulted in high ion yields. This ultrasensitive analytical platform enabled the MS analysis of single yeast cells. We extended these NAPA studies from yeast to other microorganisms, including green algae (Chlamydomonas reinhardtii) that captured energy from sunlight on a massive scale. Combining cellular perturbations, e.g., through environmental changes, with the newly developed single cell analysis methods enabled us to follow dynamic changes induced in the cells. In effect, we were able to use individual cells as a “laboratory,” and approached the long-standing goal of establishing a “lab-in-a-cell.” Model systems for these studies included cells of cyanobacteria (Anabaena), yeast (Saccharomyces cerevisiae), green algae (C. reinhardtii) and Arabidopsis thaliana.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Searching for Dark Matter with Superconducting Qubits

Dark matter is an enduring mystery in our quest to understand the fundamental constituents of our universe. Low mass bosons, such the axion or hidden photon, are compelling dark matter candidates. We leverage their potential interactions with electromagnetic fields, whereby the dark matter (of unknown mass) on rare occasion converts into a single photon, to devise a method of detecting these candidates. Current dark matter searches operating at microwave frequencies use a resonant cavity to coherently accumulate the field sourced by the dark matter and a near standard quantum limited (SQL) linear amplifier to read out the cavity signal. To further increase sensitivity to the dark matter signal and enable future searches, sub-SQL detection techniques are required.In this thesis, I report the development of a novel microwave photon counting technique and a new exclusion limit on hidden photon dark matter. We operate a superconducting qubit to make repeated quantum non-demolition measurements of cavity photons and apply a hidden Markov model analysis to reduce the noise to 15.7 dB below the quantum limit, with overall detector performance limited by a residual background of real photons. With the present device, we perform a hidden photon search and constrain the kinetic mixing angle to less than 1.68 x 10-15 in a band around 6.011 GHz (24.86 micro-eV) with an integration time of 8.33 s. This demonstrated noise reduction technique enables future dark matter searches to be sped up by a factor of 1300. By coupling a qubit to an arbitrary quantum sensor, more general sub-SQL metrology is possible with the techniques presented in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electro-analytical method for the quantities evaluation of the silicon solar cell by DC and AC characterization technique

Highlights: • Exact electro-analytical method for evaluation of silicon solar cells. • DC and AC characterization technique to determine the performance limiting parameters of solar cells. • EIS is used to get an insight into the solar cells and parameter optimization. - Abstract: Mono and Poly- crystalline silicon (Si) based solar cell has proven to be the most efficient and matured technology till date. The present work reports an exact electro-analytical method for the evaluation of different performance parameters in the current voltage response of the Si solar cell by DC and AC characterization technique. The extracted solar cell parameters from DC and AC techniques were compared with each other under the proper limiting conditions of low and high forward bias. The DC and AC characterization are used to determine the bias dependence of ideality factor and series resistance, respectively. The current-voltage (J-V) characteristics is combined with the impedance spectroscopy (IS) measurements to reveal the various interfacial, resistive and recombination analysis of the silicon solar cell. Herein the experimentally obtained J-V characteristics under the illumination condition have been reconstructed by individually extracted parameters from DC and AC measurements. Moreover, the present mechanistic provides a simple tool for analysing the commercial Si solar cell with a wide applicability for other solar cells.

14 SOLAR ENERGY↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoscale Chemical Imaging of Zeolites Using Atom Probe Tomography

Understanding structure–composition–property relationships in zeolite-based materials is critical to engineering improved solid catalysts. However, this can be difficult to realize as even single zeolite crystals can exhibit heterogeneities spanning several orders of magnitude, with consequences for, for example, reactivity, diffusion as well as stability. Great progress has been made in characterizing these porous solids using tomographic techniques, though each method has an ultimate spatial resolution limitation. Atom probe tomography (APT) is the only technique so far capable of producing 3D compositional reconstructions with sub-nanometer-scale resolution, and has only recently been applied to zeolite-based catalysts. Herein, we discuss the use of APT to study zeolites, including the critical aspects of sample preparation, data collection, assignment of mass spectral peaks including the predominant CO peak, the limitations of spatial resolution for the recovery of crystallographic information, and proper data analysis. All sections are illustrated with examples from recent literature, as well as previously unpublished data and analyses to demonstrate practical strategies to overcome potential pitfalls in applying APT to zeolites, thereby highlighting new insights gained from the APT method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of the Dielectric Properties of Thin High-Explosive Samples Using a Parallel Plate Test Fixture

This report presents results of a study of the dielectric properties of several high explosive materials, including Composition B, C-4, Detasheet, Semtex 1A, Semtex 1H, and Semtex 10. The capacitance and dispersion of samples up to ten mm thick were measured at 24 and 65°C using a parallel plate test fixture. In this configuration, capacitance is proportional to the real component of the complex dielectric constant (or permittivity) of the material, while the dispersion is equal to the imaginary component of the dielectric constant divided by the real component. Measurements were performed at two temperatures to determine whether these dielectric properties might be used to monitor moderate temperature changes within these materials using an external fringing field capacitor. It was found that the real dielectric constant of the high explosives generally changed by only about 1% on heating from 24 to 65°C, and that the externally measured capacitance is therefore not a reliable parameter for monitoring temperature changes in these explosives. Temperature- based changes in the dispersion were often 20% or greater, and for several materials (e.g., Composition B, Detasheet) the temperature and dispersion showed good correlation as the temperature of the explosive was cycled up and down. It is thus possible that for some high explosives the externally measured dispersion is a useful parameter for monitoring temperature changes. However, other factors may limit the usefulness of this technique, including the need to have the plates of a fringing field capacitor in direct contact with the high explosive to obtain measurements, and the limited penetration depth of the fringing field into the explosive material.

36 MATERIALS SCIENCE↗

Preliminary Design of Low-Thrust Interplanetary Missions

For interplanetary missions, highly efficient electric propulsion systems can be used to increase the mass delivered to the destination and/or reduce the trip time over typical chemical propulsion systems. This technology is being demonstrated on the Deep Space 1 mission - part of NASA's New Millennium Program validating technologies which can lower the cost and risk and enhance the performance of future missions. With the successful demonstration on Deep Space 1, future missions can consider electric propulsion as a viable propulsion option. Electric propulsion systems, while highly efficient, produce only a small amount of thrust. As a result, the engines operate during a significant fraction of the trajectory. This characteristic makes it much more difficult to find optimal trajectories. The methods for optimizing low-thrust trajectories are typically categorized as either indirect, or direct. Indirect methods are based on calculus of variations, resulting in a two-point boundary value problem that is solved by satisfying terminal constraints and targeting conditions. These methods are subject to extreme sensitivity to the initial guess of the variables - some of which are not physically intuitive. Adding a gravity assist to the trajectory compounds the sensitivity. Direct methods parameterize the problem and use nonlinear programming techniques to optimize an objective function by adjusting a set of variables. A variety of methods of this type have been examined with varying results. These methods are subject to the limitations of the nonlinear programming techniques. In this paper we present a direct method intended to be used primarily for preliminary design of low-thrust interplanetary trajectories, including those with multiple gravity assists. Preliminary design implies a willingness to accept limited accuracy to achieve an efficient algorithm that executes quickly.

Sims, Jon A.↗