Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Uranium-Loaded Water Treatment Resins: 'Equivalent Feed' at NRC and Agreement State-Licensed Uranium Recovery Facilities - 12094

Community Water Systems (CWSs) are required to remove uranium from drinking water to meet EPA standards. Similarly, mining operations are required to remove uranium from their dewatering discharges to meet permitted surface water discharge limits. Ion exchange (IX) is the primary treatment strategy used by these operations, which loads uranium onto resin beads. Presently, uranium-loaded resin from CWSs and mining operations can be disposed as a waste product or processed by NRC- or Agreement State-licensed uranium recovery facilities if that licensed facility has applied for and received permission to process 'alternate feed'. The disposal of uranium-loaded resin is costly and the cost to amend a uranium recovery license to accept alternate feed can be a strong disincentive to commercial uranium recovery facilities. In response to this issue, the NRC issued a Regulatory Issue Summary (RIS) to clarify the agency's policy that uranium-loaded resin from CWSs and mining operations can be processed by NRC- or Agreement State-licensed uranium recovery facilities without the need for an alternate feed license amendment when these resins are essentially the same, chemically and physically, to resins that licensed uranium recovery facilities currently use (i.e., equivalent feed). NRC staff is clarifying its current alternate feed policy to declare IX resins as equivalent feed. This clarification is necessary to alleviate a regulatory and financial burden on facilities that filter uranium using IX resin, such as CWSs and mine dewatering operations. Disposing of those resins in a licensed facility could be 40 to 50 percent of the total operations and maintenance (O and M) cost for a CWS. Allowing uranium recovery facilities to treat these resins without requiring a license amendment lowers O and M costs and captures a valuable natural resource. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Evaluation of Loading DOE Standard Canisters in the INL CPP-603 Irradiated Fuel Storage Facility - 20543

This paper looks at the equipment and operations necessary to load United States Department of Energy (DOE)-owned Spent Nuclear Fuel (SNF) into DOE Standard Canisters in the CPP-603 Irradiated Fuel Storage Facility (IFSF) in the Idaho Nuclear Technology and Engineering Center (INTEC) area at Idaho National Laboratory (INL). Two types of fuels are looked at in this evaluation: Advanced Test Reactor (ATR) fuel (uranium-aluminide fuel with aluminum cladding) and Peach Bottom fuel (thorium-uranium carbide fuel in a graphite matrix). The fuel ready for loading would come from fuel storage canisters in the CPP-603 facility. The paper describes the facility, the fuel types, the DOE Standard Canisters, and existing equipment; lists the needed loading operations; reviews facility features and equipment to perform the operations; and then lists the decisions, analyses, designs, demonstrations, and modifications that will be needed to perform the loading of DOE-owned SNF into DOE Standard Canisters in the CPP-603 IFSF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Base-load high-temperature reactors with variable electricity to the grid using Brayton cycles to match low-carbon electricity markets - 18622

The electricity markets are changing because of (1) the transition to a low-carbon electricity grid and (2) addition of solar and wind. The large-scale addition of wind or solar results in low-electricity prices at times of high wind or solar output. It also results in higher electricity prices at times of low wind and solar input. This changing market in the United States favors natural gas plants with low capital costs and high operating costs where it is economic to shut down the gas turbine at times of low electricity prices. Such markets are less favorable to base-load nuclear plants. The change in the markets requires rethinking high-temperature reactor (HTR) power systems to enable base-load reactor operations with variable electricity to the grid. Base-load reactor operation is required to minimize costs but electricity output to the grid must be maximized at times of high prices to maximize total revenue. This can be accomplished by HTR open or closed Brayton power cycles coupled to high-temperature heat storage systems such as Firebrick Resistance-Heated Energy Storage (FIRES) or using auxiliary natural gas if coupled to an open Brayton power cycle. The temperature limits of HTRs are far below gas turbine temperature limits. This characteristic allows the power cycle to operate at base-load on nuclear heat with the option of added peak power by increasing compressed gas temperatures after nuclear heating but before the power turbine with other heat sources (natural gas, FIRES). For the case we have studied, the incremental heat to electricity efficiency is above 66%. The high efficiency is because it is a thermodynamic topping cycle. Because incremental heat-to-electricity efficiency is greater than a stand-alone natural gas plant (60%), such plants can directly compete against natural gas. At times of low electricity prices, electricity from the HTR and purchased from the grid is used to charge FIRES that can provide high-temperature heat as a substitute for natural gas for peak electricity production. Such nuclear Brayton cycles can replace fossil fuels in providing variable electricity on demand to the grid. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles

This paper provides new regression models for demand reduction of Demand Response programs for the purpose of ex ante evaluation of the programs and screening for recruiting customer enrollment into the programs. The proposed regression models employ load sensitivity to outside air temperature and representative load pattern derived from cluster analysis of customer baseline load as explanatory variables. The proposed models examined their performances from the viewpoint of validity of explanatory variables and fitness of regressions, using actual load profile data of Pacific Gas and Electric Company's commercial and industrial customers who participated in the 2008 Critical Peak Pricing program including Manual and Automated Demand Response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Increasing runoff and sediment load from the Greenland ice sheet at kangerlussuaq (Sonder Stromfjord) in a 30-year perspective, 1979-2008

This observation and modeling study provides insights into runoff and sediment load exiting the Watson River drainage basin, Kangerlussuaq, West Greenland during a 30 year period (1978/79-2007/08) when the climate experienced increasing temperatures and precipitation. The 30-year simulations quantify the terrestrial freshwater and sediment output from part of the Greenland Ice Sheet (GrIS) and the land between the GrIS and the ocean, in the context of global warming and increasing GrIS surface melt. We used a snow-evolution modeling system (SnowModel) to simulate the winter accumulation and summer ablation processes, including runoff and surface mass balance (SMB), of the Greenland ice sheet. Observed sediment concentrations were related to observed runoff, producing a sediment-load time series. To a large extent, the SMB fluctuations could be explained by changes in net precipitation (precipitation minus evaporation and sublimation), with 8 out of 30 years having negative SMB, mainly because of relatively low annual net precipitation. The overall trend in net precipitation and runoff increased significantly, while 5MB increased insignificantly throughout the simulation period, leading to enhanced precipitation of 0.59 km{sup 3} w.eq. (or 60%), runoff of 0.43 km{sup 3} w.eq (or 54%), and SMB of 0.16 km3 w.eq. (or 86%). Runoff rose on average from 0.80 km{sup 3} w.eq. in 1978/79 to 1.23 km{sup 3} w.eq. in 2007/08. The percentage of catchment oudet runoff explained by runoff from the GrIS decreased on average {approx} 10%, indicating that catchment runoff throughout the simulation period was influenced more by precipitation and snowmelt events, and less by runoff from the GrIS. Average variations in the increasing Kangerlussuaq runoff from 1978/79 through 2007/08 seem to follow the overall variations in satellite-derived GrIS surface melt, where 64% of the variations in simulated runoff were explained by regional melt conditions on the GrIS. Throughout the simulation period, the sediment load varied from a minimum of 0.96 x 10{sup 6} t y{sup -1} in 1991/92 to a maximum of 3.52 x 10{sup 6} t y{sup -1} in 2006/07, showing an average increase of sediment load of 9.42 x 10{sup 5} t (or 72%) throughout the period.

58 GEOSCIENCES↗

Acoustic emission analysis of cyclically loaded superelastic shape memory alloy fiber reinforced mortar beams

Superelastic shape memory alloys (SMAs) are metallic alloys that can recover their nonlinear deformations upon unloading. The use of SMAs in cementitious composites as fibers can enable crack recovery and re-centering capabilities. In this study, the crack recovery characteristics of SMA fiber reinforced mortar specimens subjected to flexural cyclic loading are studied through acoustic emission analysis. SMA fiber reinforced mortar specimens with fiber volume ratios of 0.3%, 0.5% and 1.0% are tested under cyclic flexural loads. Acoustic emissions (AE) signals are captured and analyzed to characterize the crack formation and crack width development at each cycle of loading. In addition, the crack width propagation of the specimens is monitored by Digital Image Correlation measurement system and is used as a basis in AE analyses. Results show that the SMA fiber reinforced mortars exhibit considerable re-centering and crack recovery characteristics at large deformation amplitudes.

36 MATERIALS SCIENCE↗

Properly Evaluating load-following products

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Accurate Heating and Cooling Load Calculations

This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risksincurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

1.5 MW RF Load for ITER

Calabazas Creek Research, Inc. developed a 1.5 MW RF load for the ITER fusion research facility currently under construction in France. This program leveraged technology developed in two previous SBIR programs that successfully developed high power RF loads for fusion research applications. This program specifically focused on modifications required by revised technical performance, materials, and assembly specification for ITER. This program implemented an innovative approach to actively distribute the RF power inside the load to avoid excessive heating or arcing associated with constructive interference. The new design implemented materials and assembly changes required to meet specifications. Critical components were built and successfully tested during the program.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Policy and Cost Allocation Considerations for Large Electric Load Interconnections: Emerging Policy Trends in Rate Structures, Interconnection, and Cost Impacts on Other System Users

Load growth in the United States is rapidly increasing: load from data centers alone has tripled over the past decade, and this growth is forecasted to continue accelerating. These and other large electric loads (LELs) promise economic benefits at the state and local level, but their deployment has also led to increasing concerns about grid impacts and potential cost shifts onto other ratepayers. Legislators, regulators, and other stakeholders are increasingly proposing and enacting policies in effort to balance these and other considerations. This white paper reviews state-level legislation, selected utility rate cases, and relevant federal orders in an effort to describe and categorize relevant trends in policies related to LEL cost allocation, interconnection, and deployment. Policy categories identified through this review include tax incentives, rate actions, and requirements related to interconnection, permitting, and reporting. By offering a taxonomy of policies, this white paper aims to offer a resource to policymakers and other stakeholders navigating this transformative moment for the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive stratified importance sampling: hybridization of extrapolation and importance sampling Monte Carlo methods for estimation of wind turbine extreme loads

Wind turbine extreme load estimation is especially difficult because turbulent inflow drives nonlinear turbine physics and control strategies; thus there can be huge differences in turbine response to essentially equivalent environmental conditions. The two main current approaches, extrapolation and Monte Carlo sampling, are both unsatisfying: extrapolation-based methods are dangerous because by definition they make predictions outside the range of available data, but Monte Carlo methods converge too slowly to routinely reach the desired 50-year return period estimates. Thus a search for a better method is warranted. We introduce an adaptive stratified importance sampling approach that allows for treating the choice of environmental conditions at which to run simulations as a stochastic optimization problem that minimizes the variance of unbiased estimates of extreme loads. Furthermore, the framework, built on the traditional bin-based approach used in extrapolation methods, provides a close connection between sampling and extrapolation, and thus allows the solution of the stochastic optimization (i.e., the optimal distribution of simulations in different wind speed bins) to guide and recalibrate the extrapolation. Results show that indeed this is a promising approach, as the variance of both the Monte Carlo and extrapolation estimates are reduced quickly by the adaptive procedure. We conclude, however, that due to the extreme response variability in turbine loads to the same environmental conditions, our method and any similar method quickly reaches its fundamental limits, and that therefore our efforts going forward are best spent elucidating the underlying causes of the response variability.

17 WIND ENERGY↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗