Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Post-irradiation examination of commercial tantalum alloys following neutron irradiation

Post irradiation examination of two commercial tantalum alloys (based on Ta-8 %W) revealed significant irradiation hardening following neutron irradiation in the High Flux Isotope Reactor at Oak Ridge National Laboratory. Tensile samples of commercial Ta alloys T-111 and ASTAR-811C were irradiated to a total neutron fluence (E > 0.1 MeV) in the range (2–4)x10 21 n/cm 2 (0.39–0.75 dpa) at an irradiation temperature near 900 °C. Tensile testing conducted at room temperature and at 800 °C revealed significant irradiation hardening under all test conditions. Samples that were tensile tested at room temperature exhibited brittle failure, whereas ductility was maintained for elevated temperature testing. The irradiation hardening and embrittlement noted for both alloys was attributed to irradiation-induced dislocation loop formation as confirmed through scanning transmission electron microscopy analysis. Corresponding energy dispersive x-ray spectroscopy revealed radiation-induced segregation of Hf in these loop populations. This Hf enrichment is shown to result in eventual co-precipitation of elongated (Hf,O)-rich precipitates along the dislocation loops. Further, these results show that irradiation hardening is enhanced via irradiation-enhanced precipitation at elevated irradiation temperatures. Consequently, the minimum recommended operating temperature window for Ta alloys should be increased to account for observed hardening/embrittlement at irradiation temperatures as high as 900 °C (1,173 K).

36 MATERIALS SCIENCE↗

Acceleration of Semiempirical QM/MM Methods through Message Passage Interface (MPI), Hybrid MPI/Open Multiprocessing, and Self-Consistent Field Accelerator Implementations

The strategy and implementation of scalable and efficient semiempirical (SE) QM/MM methods in CHARMM are described. The serial version of the code was first profiled to identify routines that required parallelization. Afterward, the code was parallelized and accelerated with three approaches. The first approach was the parallelization of the entire QM/MM routines, including the Fock matrix diagonalization routines, using the CHARMM message passage interface (MPI) machinery. In the second approach, two different self-consistent field (SCF) energy convergence accelerators were implemented using density and Fock matrices as targets for their extrapolations in the SCF procedure. In the third approach, the entire QM/MM and MM energy routines were accelerated by implementing the hybrid MPI/open multiprocessing (OpenMP) model in which both the task- and loop-level parallelization strategies were adopted to balance loads between different OpenMP threads. The present implementation was tested on two solvated enzyme systems (including <100 QM atoms) and an S N 2 symmetric reaction in water. The MPI version exceeded existing SE QM methods in CHARMM, which include the SCC-DFTB and SQUANTUM methods, by at least 4-fold. The use of SCF convergence accelerators further accelerated the code by ~12–35% depending on the size of the QM region and the number of CPU cores used. Although the MPI version displayed good scalability, the performance was diminished for large numbers of MPI processes due to the overhead associated with MPI communications between nodes. This issue was partially overcome by the hybrid MPI/OpenMP approach which displayed a better scalability for a larger number of CPU cores (up to 64 CPUs in the tested systems).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strategy for stabilization of the antiferroelectric phase (Pbma) over the metastable ferroelectric phase (P2{sub 1}ma) to establish double loop hysteresis in lead-free (1−x)NaNbO{sub 3}-xSrZrO{sub 3} solid solution

A new lead-free antiferroelectric solid solution system, (1−x)NaNbO{sub 3}-xSrZrO{sub 3}, was rationalized through noting the crystal chemistry trend, of decreasing the tolerance factor and an increase in the average electronegativity of the system. The SrZrO{sub 3} doping was found to effectively stabilize the antiferroelectric (P) phase in NaNbO{sub 3} without changing its crystal symmetry. Preliminary electron diffraction and polarization measurements were presented which verified the enhanced antiferroelectricity. In view of our recent report of another lead-free antiferroelectric system (1−x)NaNbO{sub 3}-xCaZrO{sub 3} [H. Shimizu et al. “Lead-free antiferroelectric: xCaZrO{sub 3} - (1−x)NaNbO{sub 3} system (0 ≤ x ≤ 0.10),” Dalton Trans. (published online)], the present results point to a general strategy of utilizing tolerance factor to develop a broad family of new lead-free antiferroelectrics with double polarization hysteresis loops. We also speculate on a broad family of possible solid solutions that could be identified and tested for this important type of dielectric.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anomalies, unparticles, and Seiberg duality

We calculate triangle anomalies for fermions with noncanonical scaling dimensions. The most well-known example of such fermions (aka unfermions) occurs in Seiberg duality where the matching of anomalies (including mesinos with scaling dimensions between 3/2 and 5/2) is a crucial test of duality. By weakly gauging the nonlocal action for an unfermion, we calculate the one-loop three-current amplitude. Despite the fact that there are more graphs with more complicated propagators and vertices, we find that the calculation can be completed in a way that nearly parallels the usual case. We show that the anomaly factor for fermionic unparticles is independent of the scaling dimension and identical to that for ordinary fermions. This can be viewed as a confirmation that unparticle actions correctly capture the physics of conformal fixed point theories like Banks-Zaks or supersymmetric QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adler Function, Bjorken Sum Rule, and the Crewther Relation to Order {alpha}{sub s}{sup 4} in a General Gauge Theory

We compute, for the first time, the order {alpha}{sub s}{sup 4} contributions to the Bjorken sum rule for polarized electron-nucleon scattering and to the (nonsinglet) Adler function for the case of a generic color gauge group. We confirm at the same order a (generalized) Crewther relation which provides a strong test of the correctness of our previously obtained results: the QCD Adler function and the five-loop {beta} function in quenched QED. In particular, the appearance of an irrational contribution proportional to {zeta}{sub 3} in the latter quantity is confirmed. We obtain the commensurate scale equation relating the effective strong coupling constants as inferred from the Bjorken sum rule and from the Adler function at order {alpha}{sub s}{sup 4}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Medium Voltage Three-Stage Power Converter Topology for Distribution Grid Scale Energy Storage Systems

This work proposes a three-stage converter topology with a medium frequency isolation transformer for direct integration of energy storage systems into medium voltage distribution grids. The distributed architecture of the topology, using standard AC/DC converters, has been developed with the aim of plug-and-play capability and voltage and power scalability. The medium frequency transformer facilitates improved power density, while its 20:1 voltage translation capability enables the use of limited voltage level (500 Vdc) of the commercially available batteries. This paper presents the topology structure and details how it can be scaled to reach the full range of the distribution grid voltages and the required power levels. A transformer design for 500 Hz rated frequency is discussed. The control scheme of the converter equipped with voltage support, frequency support, and black start capabilities is also presented. Control hardware-in-the-loop results using OPAL-RT, with converter switching models connected to a weak IEEE-4 node test feeder modified for the aforementioned grid services, are provided to show the topology feasibility.

Chinthavali, Madhu Sudhan↗

Cost-Effective Three-Phase Current Amplifier Interface for Real-time Simulator with Relays in-the-Loop

This paper presents a prototype of a simple and cost-effective design using a high-power monolithic power amplifier that allows the relay in-the-loop connectivity for protection and control applications using a real-time simulator. This low-cost amplifier interface increases the number of protective relays in-the-loop connected with the real-time simulator, expanding the scalability of protection devices that could be tested. The amplifier control design was developed in abc coordinates and utilizes integral and proportional-resonant controllers to provide a good tracking of both the fundamental component as the dc component that might be present during fault conditions. To validate the prototype, the current signals and tripping time of a relay interfaced with the current amplifier were compared against a reference relay connected to the low-voltage interface. Both protective relays were set with a U3 Very Inverse time overcurrent curve. The experimental results exhibited similar behaviors for the breaker currents, validating the amplifier interface prototype.

Ferrari Maglia, Max↗

Measurement of the forming limit stress curve using a multi-axial tube expansion test with a digital image correlation system

A servo-controlled tension-internal pressure testing machine with an optical 3D deformation analysis system (ARAMIS) was used to measure the multi-axial plastic deformation behavior of a high-strength steel sheet for a range of strain from initial yield to fracture. The testing machine is capable of applying arbitrary principal stress or strain paths to a tubular specimen using an electrical, closed-loop servo-control system for axial force and internal pressure. Tubular specimens with an inner diameter of 44.6 mm were fabricated from a high-strength steel sheet with a tensile strength of 590 MPa and a thickness of 1.2 mm by roller bending and laser welding. Several linear and non-linear stress paths in the first quadrant of the stress space were applied to the tubular specimens in order to measure the forming limit curve (FLC) and forming limit stress curve (FLSC) of the as-received test material, in addition to the contours of plastic work and the directions of plastic strain rates. The contours of plastic work and the directions of plastic strain rates measured for the linear stress path experiments were compared with those calculated using selected yield functions in order to identify the most appropriate yield function for the test material. Moreover, a Marciniak-Kuczyński type (M-K) forming limit analysis was performed using the most appropriate yield function. The calculated and measured FLC and FLSC were compared in order to validate the M-K approach. The path-dependence of the FLC and FLSC was also investigated.

97 MATHEMATICS AND COMPUTING↗

Initial performance of the magnet system in the splitter/combiner section of the Cornell-Brookhaven Energy-Recovery Linac Test Accelerator

The Cornell-Brookhaven Energy-recovery Linac Test Ac- celerator is a four-pass, 150-MeV electron accelerator with a six-cell 1.3 GHz superconducting-RF linear accelerator and a fixed-field alternating-gradient (FFAG) return loop made up of Halbach-style quadrupole magnets. The optics matching between the linear accelerator and the return loop is achieved with a conventional magnet system comprised of 50 dipole magnets and 64 quadrupole magnets in four beamlines at each end of the linac. The 42-, 78-, 114- and 150-MeV electron beams are separated into independent vacuum chambers in order to allow for the path-length ad- justment required by energy recovery. We report on the first beam tests of the initial installation of the splitter/combiner section at the exit of the linac. The vacuum system of the 42-MeV S1 line was installed during the first week of April. Nine dipole and four quadrupole magnets were installed and surveyed into position the following week, and the water cooling system was commissioned. A 6-MeV beam passed through the line on April 11 with no need for adjusting pre-set magnet excitation currents. One week later, time- of-flight measurements were used to calibrate and phase the individual superconducting RF cavities. The S1 magnet settings were then scaled up to achieve 5-cavity, 42-MeV operation through the first nine FFAG permanent-magnet quadrupoles. This initial Fractional Arc Test will conclude on May 18, when the installation of the remaining seven split- ter/combiner lines and the return loop will begin. CBETA operations are scheduled to begin in early 2019.

43 PARTICLE ACCELERATORS↗

An Innovative Hybrid Loop-Pool Design for Sodium Cooled Fast Reactor

The existing sodium cooled fast reactors (SFR) have two types of designs – loop type and pool type. In the loop type design, such as JOYO (Japan) [1] and MONJU (Japan), the primary coolant is circulated through intermediate heat exchangers (IHX) external to the reactor tank. The major advantages of loop design include compactness and easy maintenance. The disadvantage is higher possibility of sodium leakage. In the pool type design such as EBR-II (USA), BN-600M(Russia), Superphénix (France) and European Fast Reactor [2], the reactor core, primary pumps, IHXs and direct reactor auxiliary cooling system (DRACS) heat exchangers (DHX) all are immersed in a pool of sodium coolant within the reactor vessel, making a loss of primary coolant extremely unlikely. However, the pool type design makes primary system large. In the latest ANL’s Advanced Burner Test Reactor (ABTR) design [3], the primary system is configured in a pool-type arrangement. The hot sodium at core outlet temperature in hot pool is separated from the cold sodium at core inlet temperature in cold pool by a single integrated structure called Redan. Redan provides the exchange of the hot sodium from hot pool to cold pool through IHXs. The IHXs were chosen as the traditional tube-shell design. This type of IHXs is large in size and hence large reactor vessel is needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CBR antimicrobials inhibit RNA polymerase via at least two bridge-helix cap-mediated effects on nucleotide addition

RNA polymerase inhibitors like the CBR class that target the enzyme’s complex catalytic center are attractive leads for new antimicrobials. The catalysis by RNA polymerase involves multiple rearrangements of bridge helix, trigger loop, and active-center side chains that isomerize the triphosphate of bound NTP and two Mg 2+ ions from a preinsertion state to a reactive configuration. CBR inhibitors target a crevice between the N-terminal portion of the bridge helix and a surrounding cap region within which the bridge helix is thought to rearrange during the nucleotide addition cycle. Here, we report crystal structures of CBR inhibitor/Escherichia coli RNA polymerase complexes as well as biochemical tests that establish two distinct effects of the inhibitors on the RNA polymerase catalytic site. One effect involves inhibition of trigger-loop folding via the F loop in the cap, which affects both nucleotide addition and hydrolysis of 3'-terminal dinucleotides in certain backtracked complexes. The second effect is trigger-loop independent, affects only nucleotide addition and pyrophosphorolysis, and may involve inhibition of bridge-helix movements that facilitate reactive triphosphate alignment.

59 BASIC BIOLOGICAL SCIENCES↗

Comprehensive tracking study for the H-dipoles and common magnets in the splitter sections of the Cornell/Brookhaven Energy-Recovery-Linac Test Accelerator

The Cornell-Brookhaven Energy-Recovery-Linac Test Accelerator will have two splitter sections responsible for and guiding beams of 42, 78, 114, and 150 MeV energies between the Fixed-Field Alternating Gradient return loop and the Main Linac Cryomodule [6], correcting optics, and providing path length adjustments. Modeling of all 36 H-dipole magnets under contract with Elytt Energy has been completed. Four common dipoles, two of which are needed for next year’s Fractional Arc Test, will be added to the order with Elytt. The design of these magnets is underway. This report describes the findings of the tracking studies of the 36 H-dipoles and gives the status of the common dipoles.

43 PARTICLE ACCELERATORS↗

Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

More supersymmetric Wilson loops

We present a large new family of Wilson loop operators in N=4 supersymmetric Yang-Mills theory. For an arbitrary curve on the three dimensional sphere one can add certain scalar couplings to the Wilson loop so it preserves at least two supercharges. Some previously known loops, notably the 1/2 BPS circle, belong to this class, but we point out many more special cases which were not known before and could provide further tests of the AdS/CFT correspondence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Closing the Loop Between In Situ Stress Complexity and EGS Fracture Complexity (Quarterly Research Performance Progress Report: Q3Y3)

As part of Task 1, we have started by testing our modeling capabilities by reproducing isothermal DFIT simulations presented in the literature. To start, we have been working towards adjusting numerical parameters to reproduce DFIT tests with different fracture geometries. Then, we have focused modeling the DFIT conducted at well 58-32 (cycle 4 in zone 2). Specifically, we have carefully analyzed the influence of the aperture-contact stress relationship and investigated how two different laws affect model results. We have also introduced thermal effects in the model and rerun the simulations to estimate the effect of cooling on the DFIT response. Due to the small amount of fluid injected during a DFIT, thermal effects seem to be moderate.

15 GEOTHERMAL ENERGY↗

High-energy synchrotron study of in-pile-irradiated U–Mo fuels

Here synchrotron scattering analysis results on U–7wt.%Mo fuel specimens irradiated in the Advanced Test Reactor to three burnup levels (3.0, 5.2, and 6.3 × 1021 fission/cm3) are reported. Mature fission gas bubble superlattice was observed to form at intermediate burnup. The superlattice constant was determined to be 11.7 and 12.0 nm by wide-angle and small-angle scattering respectively. Grain sub-division takes place throughout the irradiation and causes the collapse of the superlattice at high burnup. The bubble superlattice expands the U–Mo lattice and acts as strong sink for radiation-induced defects. The evolution of dislocation loops was, therefore, suppressed until the bubble superlattice collapsed.

metallic nuclear fuel↗