Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Error analysis of DIAL measurements of ozone by a Shuttle excimer lidar

Attention is given to an error analysis of DIAL measurements of stratospheric ozone from the Space Shuttle. It is shown that a transmitter system consisting of a KrF excimer laser pumping gas cells of H2 or D2 producing output wavelengths in the near UV is useful for the measurement of ozone in a 15-50-km altitude range. It is noted that for increased levels of stratospheric aerosols experienced after violent volcanic eruptions, the relative uncertainties of ozone densities will be large in the region below about 24 km.

Uchino, Osamu↗

Uncertainty quantification for radiation measurements: Bottom-up error variance estimation using calibration information

One example of top-down uncertainty quantification (UQ) involves comparing two or more measurements on each of multiple items. One example of bottom-up UQ expresses a measurement result as a function of one or more input variables that have associated errors, such as a measured count rate, which individually (or collectively) can be evaluated for impact on the uncertainty in the resulting measured value. In practice, it is often found that top-down UQ exhibits larger error variances than bottom-up UQ because some error sources are present in the fielded assay methods used in top-down UQ that are not present (or not recognized) in the assay studies used in bottom-up UQ One would like better consistency between the two approaches in order to claim understanding of the measurement process. The purpose of this paper is to refine bottom-up uncertainty estimation by using calibration information so that if there are no unknown error sources, the refined bottom-up uncertainty estimate will agree with the top-down uncertainty estimate to within a specified tolerance. Then, in practice, if the top-down uncertainty estimate is larger than the refined bottom-up uncertainty estimate by more than the specified tolerance, there must be omitted sources of error beyond those predicted from calibration uncertainty. The paper develops a refined bottom-up uncertainty approach for four cases of simple linear calibration: (1) inverse regression with negligible error in predictors, (2) inverse regression with non negligible error in predictors, (3) classical regression followed by inversion with negligible error in predictors, and (4) classical regression followed by inversion with non-negligible errors in predictors. Our illustrations are of general interest, but are drawn from our experience with nuclear material assay by non-destructive assay. The main example we use is gamma spectroscopy that applies the enrichment meter principle. Previous papers that ignore error in predictors have shown a tendency for inverse regression to have lower error variance than classical regression followed by inversion. Our paper supports that tendency both with and without error in predictors. Furthermore, the paper shows that calibration parameter estimates using error in predictor methods perform worse than without using error in predictor methods in the case of inverse regression, but perform better than without using error in predictor methods in the case of classical regression followed by inversion. Both inverse and classical regression involve the ratio of dependent random variables; therefore, the assumed error distribution(s) will matter in parameter estimation and in uncertainty calculations. Mainly for that reason, calibration using a single predictor is distinct from simple regression, and it has not been thoroughly treated in the literature, nor in the ISO Guide to the Expression of Uncertainty in Measurements (GUM). This refined approach is based on simulation, because we illustrate that analytical approximations are not adequate when there are, for example, 10 or fewer calibration measurements, which is common in calibration applications, each consisting of measured responses from known quantities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing NWP Model Errors Using Doppler-Lidar Measurements of Recurrent Regional Diurnal Flows: Marine-Air Intrusions into the Columbia-River Basin

Ground-based Doppler-lidar instrumentation provides atmospheric wind data at dramatically improved accuracies and spatial/temporal resolutions. These capabilities have provided new insights into atmospheric flow phenomena, but they also should have a strong role in NWP model improvement. Insight into the nature of model errors can be gained by studying recurrent atmospheric flows, here a regional summertime diurnal sea breeze and subsequent marine-air intrusion into the arid interior of Oregon-Washington, where these winds are an important windenergy resource. These marine intrusions were sampled by three scanning Doppler lidars in the Columbia-River Basin as part of the Second Wind Forecast Improvement Project (WFIP2), using data from summer 2016. Lidar time-height cross sections of wind speed identified eight days when the diurnal-flow cycle, (peak wind speeds at midnight, afternoon minima) was obvious and strong. Eight-day composite time-height cross sections of lidar wind speeds are used to validate those generated by the operational NCEP-HRRR model. HRRR simulated the diurnal wind cycle, but produced errors in the timing of onset and significant errors due to a premature nighttime demise of the intrusion flow, producing low-bias errors of 6 m s-1 . Day-to-day and in the composite, whenever a marine intrusion occurred, HRRR made these same errors. The errors occurred under a range of gradient wind conditions indicating that they resulted from the misrepresentation of physical processes within a limited region around the measurement locations. Because of their generation within a limited geographical area, field-measurement programs can be designed to find and address the sources of these NWP errors.

Banta, Robert M.↗

QM02 Strength Measurement

In late April, Paul Emma reported that his orbit fitting program could find a reasonably good fit only if the strength of QM02 was changed from design value of -5.83 kG to -6.25 kG - a strength change of 7.3%. In late May, we made a focal length measurement of QM02 by turning off all focusing optics between YC07 and BPMS1 (in the spectrometer line) except for QM02 and adjusted the strength of QM02 so that vertical kicks by YC07 did not produce any displacements at BPMS1 (see Figure 1). The result was quoted in the LCLS elog was that QM02 appeared to 6% too weak, and approximately agreed with Paul's observation. The analysis used for the entry in the log book was based on the thin lens approximation and used the following numbers: Distance YC07 to QM02 - 5.128 m; Distance QM02 to BPMS1 - 1.778 m; and Energy - 135 MeV. These distances were computed from the X,Z coordinates given the on the large plot of the Injector on the wall of the control room. On review of the MAD output file coordinates, it seems that the distance used for QM02 to BPMS1 is not 1.778 m. The correct value is Distance, center of QM02 to BPMS1 - 1.845 m. There may be a typo on the wall chart values for the coordinates of BPMS1, or perhaps there was a misinterpretation of edge versus center of QM02. In any case, the effect of this change is that the thin lens estimate changes from 6% too weak to 9% too weak. At John Galayda's suggestion, we looked into the thin lens versus thick lens approximation. A Mathematica program was written to solve for the K value of the QM02, in the thick lens approximation, that provides point to point focusing from YC07 to BPMS1, and to compare this number with the value obtained using the thin lens approximation. The length of QM02 used in the thick lens calculation is the effective length determined by magnetic measurements of 0.108 m. The result of the Mathematica calculation is that the thin lens approximation predicts less magnet strength is required to produce the same focusing by about 1.3%. When both the distance correction and the thick lens approximation are taken into account, the result is: K{sub thick} - K{sub mm}/K{sub thick} = -7.6% where K{sub mm} is the value obtained from magnetic measurements and K{sub thick} is the value of K obtained from the focal length measurement in the thick lens approximation. That is, QM02 acts weaker than it was measured by magnetic measurements by 7.6%. This is remarkably close to Paul's original estimate. The unexpected weakness could in principle be due to several things: shorted turns, a current calibration error, magnetic measurement error; it could even be due to the presence of an gradient from QM01, which is of opposite sign and right next to QM02, despite it being set to zero current (although it was not DAC-zeroed). Plans have been implemented to remove and replace QM02 at the earliest ROD.

43 PARTICLE ACCELERATORS↗

Iterative Stress Reconstruction Algorithm to Estimate Three-Dimensional Residual Stress Fields in Manufactured Components

Residual stress (RS) significantly impacts the mechanical performance of components. Measurement of RS often provides incomplete data in terms of components of stress and spatial density. Employing such fields in finite element simulations results in significant modification of the field to achieve equilibrium and compatibility among strains. To overcome this, an iterative stress reconstruction algorithm (ISRA) is developed to estimate 3D RS fields that satisfy equilibrium, are stress component-wise complete, and represent the characterized data sampled. An Al 7075-T651 plate and an additively manufactured (AM) A36 steel wall are considered for RS reconstruction using measurement data from the literature. A maximum variation of ~2.5 MPa in the Al plate, and ~10 MPa in the steel wall are observed between the reconstructed and measured stresses. Furthermore, unknown stress components emerge and reach significant magnitudes (upto ~2.3 MPa in the Al plate and ~45 MPa in the AM wall) during ISRA. Indeed, it is found that minor errors in measurement or data processing are eliminated through the physical requirements during ISRA. Employing a reconstructed RS field is hence not just more accurate given its compatibility, but it additionally corrects for minor errors in measurement. Furthermore, it is found that spatially dense measurement data result in convergence with fewer iterations. Finally, although ISRA yields a nonunique solution dependent on boundary conditions, measurement errors, fitting errors, and mesh density, it accommodates for uncertainties and inaccuracies in measurement, as opposed to failing to reach a physically realistic converged solution.

42 ENGINEERING↗

Assessment of relative error sources in IR DIAL measurement accuracy

An assessment is made of the role the various error sources play in limiting the accuracy of infrared differential absorption lidar measurements used for the remote sensing of atmospheric species. An overview is presented of the relative contribution of each error source including the inadequate knowledge of the absorption coefficient, differential spectral reflectance, and background interference as well as measurement errors arising from signal fluctuations.

Menyuk, N.↗

Error Analysis of Wind Measurements for the University of Illinois Sodium Doppler Temperature System

Four-frequency lidar measurements of temperature and wind velocity require accurate frequency tuning to an absolute reference and long term frequency stability. We quantify frequency tuning errors for the Illinois sodium system, to measure absolute frequencies and a reference interferometer to measure relative frequencies. To determine laser tuning errors, we monitor the vapor cell and interferometer during lidar data acquisition and analyze the two signals for variations as functions of time. Both sodium cell and interferometer are the same as those used to frequency tune the laser. By quantifying the frequency variations of the laser during data acquisition, an error analysis of temperature and wind measurements can be calculated. These error bounds determine the confidence in the calculated temperatures and wind velocities.

Pfenninger, W. Matthew↗

Dose Error Correction Using Simulation Extrapolation for Community Noise Dose-Response Modeling

The objective of this work is to provide a framework to account and correct for dose error in dose-response modeling due to measurement uncertainty. Error in noise measurements, especially in the case of limited monitoring locations in a community, can lead to an attenuation or misestimation of parameters in dose-response models. This error can result in overpredicted annoyance at lower doses and underpredicted annoyance at higher doses. Simulated data in the present work are based on previous NASA community studies and incorporate a notional design for future studies with the X-59 aircraft. Several populations of different annoyance response sensitivities are included. Simulation extrapolation (SIMEX, Cook and Stefanski 1994) is used to correct for the dose error in a simple, fully pooled logistic regression. Results indicate the negative impact of attenuation is greatly diminished for all amounts of dose error considered, regardless of a population’s annoyance sensitivity. Therefore, SIMEX can help produce a more accurate dose-response relationship.

SIMEX↗

Error margin for antenna gain measurements

The specification of measured antenna gain is incomplete without knowing the error of the measurement. Also, unless gain is measured many times for a single antenna or over many identical antennas, the uncertainty or error in a single measurement is only an estimate. In this paper, we will examine in detail a typical error budget for common antenna gain measurements. We will also compute the gain uncertainty for a specific UHF horn test that was recently performed on the Jet Propulsion Laboratory (JPL) antenna range. The paper concludes with comments on these results and how they compare with the 'unofficial' JPL range standard of +/- ?.

error antennas gain↗

Spectral characteristics of time-dependent orbit errors in altimeter height measurements

A mean reference surface and time-dependent orbit errors are estimated simultaneously for each exact-repeat ground track from the first two years of Geosat sea level estimates based on the Goddard Earth model (GEM)-T2 orbits. Motivated by orbit theory and empirical analysis of Geosat data, the time-dependent orbit errors are modeled as 1 cycle per revolution (cpr) sinusoids with slowly varying amplitude and phase. The method recovers the known 'bow tie effect' introduced by the existence of force model errors within the precision orbit determination (POD) procedure used to generate the GEM-T2 orbits. The bow tie pattern of 1-cpr orbit errors is characterized by small amplitudes near the middle and larger amplitudes (up to 160 cm in the 2 yr of data considered here) near the ends of each 5- to 6-day orbit arc over which the POD force model is integrated. A detailed examination of these bow tie patterns reveals the existence of daily modulations of the amplitudes of the 1-cpr sinusoid orbit errors with typical and maximum peak-to-peak ranges of about 14 cm and 30 cm, respectively. The method also identifies a daily variation in the mean orbit error with typical and maximum peak-to-peak ranges of about 6 and 30 cm, respectively, that is unrelated to the predominant 1-cpr orbit error. Application of the simultaneous solution method to the much less accurate Geosat height estimates based on the Naval Astronautics Group orbits concludes that the accuracy of POD is not important for collinear altimetric studies of time-dependent mesoscale variability (wavelengths shorter than 1000 km), as long as the time-dependent orbit errors are dominated by 1-cpr variability and a long-arc (several orbital periods) orbit error estimation scheme such as that presented here is used.

Chelton, Dudley B.↗

CME Velocity and Acceleration Error Estimates Using the Bootstrap Method

The bootstrap method is used to determine errors of basic attributes of coronal mass ejections (CMEs) visually identified in images obtained by the Solar and Heliospheric Observatory (SOHO) mission's Large Angle and Spectrometric Coronagraph (LASCO) instruments. The basic parameters of CMEs are stored, among others, in a database known as the SOHO/LASCO CME catalog and are widely employed for many research studies. The basic attributes of CMEs (e.g. velocity and acceleration) are obtained from manually generated height-time plots. The subjective nature of manual measurements introduces random errors that are difficult to quantify. In many studies the impact of such measurement errors is overlooked. In this study we present a new possibility to estimate measurements errors in the basic attributes of CMEs. This approach is a computer-intensive method because it requires repeating the original data analysis procedure several times using replicate datasets. This is also commonly called the bootstrap method in the literature. We show that the bootstrap approach can be used to estimate the errors of the basic attributes of CMEs having moderately large numbers of height-time measurements. The velocity errors are in the vast majority small and depend mostly on the number of height-time points measured for a particular event. In the case of acceleration, the errors are significant, and for more than half of all CMEs, they are larger than the acceleration itself.

Michalek, Grzegorz↗

Intercomparison of scanner and nonscanner measurements for the Earth Radiation Budget Experiment

The Earth Radiation Budget Experiment nonscanner measurements are simulated with the scanner measurements. The error in simulating a single measurement is 1 percent for longwave and 3 percent for shortwave. Errors in simulating the average daily measurements are half these amounts. Four months of Earth Radiation Budget Satellite measurements were analyzed. The results show that changing sun geometry affects the accuracy of the nonscanner measurements. The medium field show that changing sun geometry affects the accuracy of the nonscanner measurements. The medium field of view (MFOV) total channel and scanner agree to within 2 percent on average. The wide field of view (WFOV) total channel and scanner agree to within 1 percent. For the shortwave channels, the agreement with the scanner is 2 percent for the MFOV and 2.5 percent for the WFOV.

Green, Richard N.↗

Dynamic response tests of inertial and optical wind-tunnel model attitude measurement devices

Results are presented for an experimental study of the response of inertial and optical wind-tunnel model attitude measurement systems in a wind-off simulated dynamic environment. This study is part of an ongoing activity at the NASA Langley Research Center to develop high accuracy, advanced model attitude measurement systems that can be used in a dynamic wind-tunnel environment. This activity was prompted by the inertial model attitude sensor response observed during high levels of model vibration which results in a model attitude measurement bias error. Significant bias errors in model attitude measurement were found for the measurement using the inertial device during wind-off dynamic testing of a model system. The amount of bias present during wind-tunnel tests will depend on the amplitudes of the model dynamic response and the modal characteristics of the model system. Correction models are presented that predict the vibration-induced bias errors to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment. The optical system results were uncorrupted by model vibration in the laboratory setup.

Buehrle, R. D.↗

Measurements of Aperture Averaging on Bit-Error-Rate

We report on measurements made at the Shuttle Landing Facility (SLF) runway at Kennedy Space Center of receiver aperture averaging effects on a propagating optical Gaussian beam wave over a propagation path of 1,000 in. A commercially available instrument with both transmit and receive apertures was used to transmit a modulated laser beam operating at 1550 nm through a transmit aperture of 2.54 cm. An identical model of the same instrument was used as a receiver with a single aperture that was varied in size up to 20 cm to measure the effect of receiver aperture averaging on Bit Error Rate. Simultaneous measurements were also made with a scintillometer instrument and local weather station instruments to characterize atmospheric conditions along the propagation path during the experiments.

Bastin, Gary L.↗

Application of the Global Positioning System to crustal deformation measurement. II - The influence of errors in orbit determination networks

The errors introduced into GPS measurements of a geodetic network by means of adopting different sets of stations in central and southern California as fixed points (termed fiducial stations) were investigated. Solutions for a crustal deformation network spanning distances up to 350 km were computed with a variety of fiducial networks, using fiducial coordinates determined from VLBI. Results showed that three receivers collocated with VLBI sites provide a stable reference system at a few millimeter level in the horizontal components and at 10 mm in the vertical components, indicating that local survey errors between VLBI and GPS markers at fiducial sites do not severely affect the estimates of interstation vectors.

Larson, Kristine M.↗

3ω techniques for measurement of volumetric heat capacity and anisotropic thermal conductivity of a solution processable, hybrid organic/inorganic film, Te-PEDOT:PSS

We report that measuring the thermal properties of anisotropic films of hybrid materials poses a challenge to existing metrology techniques. We have developed a new approach for measuring the volumetric heat capacity and anisotropic thermal conductivity of these systems using the 3ω method. While there exist many avenues for measuring the thermal properties of thin films, most carry with them difficult requirements such as smooth surfaces or advanced lithography. Here, we present measurements of a film's in-plane and cross-plane conductance and its volumetric heat capacity using relatively simple sample configurations, each requiring a single heater. For the measurement of volumetric heat capacity, we present a new model fitting method, relying on a standard film-on-substrate configuration. For the measurement of in-plane thermal conductance by 3ω, we have developed the use of an embedded micro-wire heater in suspended drop cast films, allowing for a 12 μm wide heater without the need for advanced lithography. We also expose the surprisingly significant effect of thermal radiation in the suspended film measurement and its associated error. Our measurements reveal a large anisotropy in the thermal conductivity of our test material, Te-PEDOT:PSS, of k in-plane / k cross-plane = 19, consistent with the nanoscale morphology of the material.

36 MATERIALS SCIENCE↗