Search NASA⌕ Search

SEARCH · Search NASA

Results for “nondestructive testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scanning Ultrasonic Spectroscopy System Developed for the Inspection of Composite Flywheels

Composite flywheels are being considered as replacements for chemical batteries aboard the International Space Station. A flywheel stores energy in a spinning mass that can turn a generator to meet power demands. Because of the high rotational speeds of the spinning mass, extensive testing of the flywheel system must be performed prior to flight certification. With this goal in mind, a new scanning system has been developed at the NASA Glenn Research Center for the nondestructive inspection of composite flywheels and flywheel subcomponents. The system uses ultrasonic waves to excite a material and examines the response to detect and locate flaws and material variations. The ultrasonic spectroscopy system uses a transducer to send swept-frequency ultrasonic waves into a test material and then receives the returning signal with a second transducer. The received signal is then analyzed in the frequency domain using a fast Fourier transform. A second fast Fourier transform is performed to examine the spacing of the peaks in the frequency domain. The spacing of the peaks is related to the standing wave resonances that are present in the material because of the constructive and destructive interferences of the waves in the full material thickness as well as in individual layers within the material. Material variations and flaws are then identified by changes in the amplitudes and positions of the peaks in both the frequency and resonance spacing domains. This work, conducted under a grant through the Cleveland State University, extends the capabilities of an existing point-by-point ultrasonic spectroscopy system, thus allowing full-field automated inspection. Results of an ultrasonic spectroscopy scan of a plastic cylinder with intentionally seeded flaws. The result of an ultrasonic spectroscopy scan of a plastic cylinder used as a proof-of-concept specimen is shown. The cylinder contains a number of flat bottomed holes of various sizes and shapes. The scanning system was able to successfully detect all the defects in the material. Ultrasonic spectroscopy results for a second specimen are shown along with a conventional ultrasonic C-scan. The second specimen is a section of a flywheel subcomponent that has a series of drilled holes and notches. This specimen is employed as a defect detection standard to evaluate the various nondestructive evaluation methods under consideration. Scanning results demonstrate the ability of the system to detect flaws on the order of 10 mils in the radial direction and 5 mils in the circumferential direction. Work conducted to date has shown that scanning ultrasonic spectroscopy is a viable tool for the inspection of composite flywheel systems. Ongoing development work is focused on refining the system and scanning parameters for improved resolution and defect detection.

Martin, Richard E.↗

Durability Characterization of Advanced Polymeric Composites at Cryogenic Temperatures

The next generation of reusable launch vehicles will require technology development in several key areas. Of these key areas, the development of polymeric composite cryogenic fuel tanks promises to present one of the most difficult technical challenges. It is envisioned that a polymer matrix composite (PMC) tank would be a large shell structure capable of containing cryogenic fuels and carrying a range of structural loads. The criteria that will be imposed on such a design include reduced weight, conformal geometry, and impermeability. It is this last criterion, impermeability, that will provide the focus of this paper. The essence of the impermeability criterion is that the tank remains leak free throughout its design lifetime. To address this criterion, one of the first steps is to conduct a complete durability assessment of the PMC materials. At Langley Research Center, a durability assessment of promising new polyimide-based PMCs is underway. This durability program has focused on designing a set of critical laboratory experiments that will determine fundamental material properties under combined thermal-mechanical loading at cryogenic temperatures. The test program provides measurements of lamina and laminate properties, including strength, stiffness, and fracture toughness. The performance of the PMC materials is monitored as a function of exposure conditions and aging time. Residual properties after exposure are measured at cryogenic temperatures and provide quantitative values of residual strength and stiffness. Primary degradation mechanisms and the associated damage modes are measured with both destructive and nondestructive techniques. In addition to mechanical properties, a range of physical properties, such as weight, glass transition, and crack density, are measured and correlated with the test conditions. This paper will report on the progress of this research program and present critical results and illustrative examples of current findings.

Gates, T. S.↗

Sustainability of gamma-ray isotopics evaluation codes

In November 2005, the international workshop 'Gamma Evaluation Codes for Plutonium and Uranium Isotope Abundance Measurements by High-Resolution Gamma Spectrometry: Current Status and Future Challenges' was held in Karlsruhe, Germany. Some of the main issues discussed during the November 2005 meeting were related to concerns voiced by international inspectorate authorities such as the International Atomic Energy Agency (IAEA), the European Atomic Energy Community (EURATOM), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) about the standardization and sustainability of gamma-ray isotopic analysis codes that are commonly used during safeguards inspections. A follow-up international workshop was conducted in Oak Ridge, TN in 2008. This workshop was in response to needs expressed by the international safeguards community during the Karlsruhe meeting and recommendations made under Action Sheet 14; a cooperative effort between the U. S. Department of Energy and ABACC. The purpose of the Oak Ridge workshop was to bring code developers and end users together to better understand the capabilities and limitations of the codes; to discuss mechanisms to ensure these codes are sustained and quality tested; and to ensure updates or revisions are performed in a controlled manner. During an Action Sheet 14 meeting held in Rio de Janeiro, Brazil in which the IAEA and EURATOM participated as observers, and in subsequent meetings of the European Safeguards Research and Development Association (ESARDA), all parties agreed that the regional working group initially established under the DOE/ABACC cooperation should be expanded to an international working group. The purpose of the international working group is to provide a forum to exchange information, discuss technical developments, and validate and test the various codes. However, progress to formally establish the working has been slowed by a lack of dedicated funding and competing priorities within the various international organizations. Recently, the ESARDA Nondestructive Assay Working Group established a dedicated website for the International Working Group on Gamma Spectrometry Techniques (1 WG-GST). In this paper, we will explore specific steps that should be taken to strengthen this working group's ability to affect development of a common testing platform and address concerns regarding applicability, sustainability and version control for these important codes.

99 GENERAL AND MISCELLANEOUS↗

Quantitative nondestructive evaluation of materials and structures

An experimental investigation was undertaken to quantify damage tolerance and resistance in composite materials impacted using the drop-weight method. Tests were conducted on laminates of several different carbon-fiber composite systems, such as epoxies, modified epoxies, and amorphous and semicrystalline thermoplastics. Impacted composite specimens were examined using destructive and non-destructive techniques to establish the characteristic damage states. Specifically, optical microscopy, ultrasonic, and scanning electron microscopy techniques were used to identify impact induced damage mechanisms. Damage propagation during post impact compression was also studied.

Smith, Barry T.↗

The influence of lay-up and thickness on composite impact damage and compression strength

The effects of composite stacking sequence, thickness, and percentage of zero-degree plies on the size, shape, and distribution of delamination through the laminate thickness and on residual compression strength following impact were studied. Graphite/epoxy laminates were impacted with an 0.5 inch diameter aluminum sphere at a specific low or high velocity. Impact damage was measured nondestructively by ultrasonic C-scans and X-radiography and destructively by the deply technique, and compression strength tests were performed. It was found that differences in compression failure strain due to stacking sequence were small, while laminates with very low percentages of zero-degree plies had similar failure loads but higher failure strains than laminates with higher percentages of zero-degree plies. Failure strain did not correlate with planar impact damage area, and delaminations in impact regions were associated with matrix cracking.

Guynn, E. G.↗

Fracture mechanics research at NASA related to the aging commercial transport fleet

NASA is conducting the Airframe Structural Integrity Program in support of the aging commercial transport fleet. This interdisciplinary program is being worked in cooperation with the U.S. airframe manufacturers, airline operators, and the FAA. Advanced analysis methods are under development and an extensive testing program is underway to study fatigue crack growth and fracture in complex built-up shell structures. Innovative nondestructive examination technologies are also being developed to provide large area inspection capability to detect corrosion, disbonds, and cracks. This paper reviews recent fracture mechanics results applicable to predicting the growth of cracks under monotonic and cyclic loading at rivets in fuselage lap-splice joints.

Aging Aircraft↗

Space Shuttle Program (SSP) Orbiter Main Propulsion System (MPS) Gaseous Hydrogen (GH2) Flow Control Valve (FCV) Poppet Eddy Current (EC) Inspection Probability of Detection (POD) Study

The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the findings and recommendations from the NESC assessment.

Piascik, Robert S.↗

Space Shuttle Program (SSP) Orbiter Main Propulsion System (MPS) Gaseous Hydrogen (GH2) Flow Control Valve (FCV) Poppet Eddy Current (EC) Inspection Probability of Detection (POD) Study: Appendices - Volume 2

The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the Appendices to the main report.

Piascik, Robert S.↗

Liquid Penetrant Testing at Goddard Space Flight Center

An overview of liquid penetrant testing at Goddard Space Flight Center and an introduction of the author to the NASA Engineering and Safety Center Nondestructive Evaluation Technical Discipline Team is provided, including author biography, an overview of NASA spaceflight customers and their applications, a high-level description of research and development initiatives, two case-studies of flight project applications, and an introduction to the rest of the Goddard Space Flight Center Nondestructive Evaluation team and their respective roles in the organization.

Smith, Nathan A.↗

Model Assisted Probability of Detection for NASA Space Missions

Model assisted probability of detection (MAPOD) uses data from simulations to improve a traditional probability of detection (POD) study. This could include extending the parameter space to reduce uncertainty or substituting experimental data with simulated data to reduce the time and cost of a POD study. In the past MAPOD was difficult due to limited computational resources, but recent innovations in simulation tools and high-performance computing have made this type of high-degree-of-freedom modeling possible, and complex structures have made it necessary. This presentation will summarize the work done by the computational nondestructive evaluation (CNDE) specialists within the Nondestructive Evaluation Sciences branch at NASA Langley Research Center (LaRC) to complete a MAPOD study for phased array ultrasound testing (PAUT) of a friction stir welding (FSW) method to be used on Space Launch System (SLS) structures. The three critical needs for a MAPOD study are a validated and verified model of the inspection technique for the structure being inspected, some experimental POD data, and an uncertainty model for both the model and the experimental data. PAUT was simulated using Extende CIVA’s UT module. The model was validated using laboratory inspection data from NASA Marshall Space Flight Center (MSFC) for a Hit/Miss POD for FSW in 2219-T87 aluminum panels representative of those used in the SLS. This model was then used to simulate flaw sizes that were originally omitted from the original POD study. The results of this new MAPOD study will be presented along with a discussion of the methods and processes used to analyze the original data, selected simulation parameters, and development of the uncertainty model used for the statistical analysis. The goal of this effort is not just to improve the POD study but to demonstrate the value of MAPOD and provide a roadmap for application of MAPOD on future projects.

Elizabeth Gregory↗

Model Assisted Probability of Detection for NASA Space Missions

Model assisted probability of detection (MAPOD) uses data from simulations to improve a traditional probability of detection (POD) study. This could include extending the parameter space to reduce uncertainty or substituting experimental data with simulated data to reduce the time and cost of a POD study. In the past MAPOD was difficult due to limited computational resources, but recent innovations in simulation tools and high-performance computing have made this type of high-degree-of-freedom modelling possible, and complex structures have made it necessary. This presentation will summarize the work done by the computational nondestructive evaluation (CNDE) group at NASA Langley Research Center (LaRC) to complete a MAPOD study for phased array ultrasound testing (PAUT) of a friction stir welding (FSW) method to be used on Space Launch System (SLS) structures. The three critical needs for a MAPOD study are a validated and verified model of the inspection technique for the structure being inspected, some experimental POD data, and an uncertainty model for both the model and the experimental data. PAUT was simulated using Extende CIVA’s UT module. The model was validated using laboratory inspection data from NASA Marshall Space Flight Center (MSFC) for a Hit/Miss POD for FSW in 2219-T87 aluminum panels representative of those used in the SLS. This model was then used to simulate flaw sizes that were originally omitted from the original POD study. The results of this new MAPOD study will be presented along with a discussion of the methods and processes used to analyze the original data, selected simulation parameters, and development of the uncertainty model used for the statistical analysis. The goal of this effort is not just to improve the POD study but to demonstrate the value of MAPOD and provide a roadmap for application of MAPOD on future projects.

Elizabeth Gregory↗

Certifying Acoustic Emission for the Crack Inspection of Integrated Pressure Components

To address the limitations of other nondestructive evaluation (NDE) methods on integrated components due to access constraints, a novel Acoustic Emission (AE) pressure vessel health test was developed in accordance with ASME BPVC.V Article 12. This test was then validated using notched Ti-6Al-4V panels taken to a stress level equivalent to 1.1 times the Maximum Allowable Working Pressure (MAWP) of a flight pressure vessel. The assessment involved utilizing JSC small sample Probability of Detection (POD) calculations, which represents the initial step towards obtaining flight certification for an NDE technique. A robust filtering technique that specifically identifies crack growth was formulated with the assistance of industry partners. This detection method exhibited superior detection ability compared to other NDE methods or microscopy. Within industry, the presence of a group of triangulated energetic crack-like indications typically leads to supplemental inspection or the failure of a tank. The experimental results confirm that this approach, commonly applied to more robust tanks, can be viably extended to integrated aerospace pressure components in scenarios where components can be subjected to pressures up to 1.1 times the MAWP. The testing process encountered delays due to sensor delivery and panel fabrication. Thus far, samples with crack initiators have shown energy levels 10 times higher than blunted controls. This suggests a trend where high individual and total cluster energy could be employed as acceptance criteria. Moreover, the cumulative energy of clusters might serve as a foundation for estimating crack sizes; however, this aspect requires further assessment and localized supplemental inspections are preferred.

certifying↗

Analysis of Legacy {sup 85}Kr Waste Form Samples - 16319

In the late 1970's, the Idaho Chemical Processing Plant conducted an R and D program on krypton encapsulation. Legacy samples composed of {sup 85}Kr incorporated in solid zeolite 5A material, and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing, have been preserved. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. After receipt and repackaging, the samples were examined by x-ray imaging and x-ray tomography. Two of the capsules appear to contain an amorphous mass within the capsules. An image of one capsule clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. An image of another capsule shows similar bead-like material within the intact capsule. One of the capsules was previously opened. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of this capsule. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the initial nondestructive assay (NDA) and the fact that there are two obviously breached samples, a plan was developed for exploratory tests that would be conducted with the breached specimens before opening the three intact capsules. Preparations are being made to determine the fraction of krypton/xenon remaining in the waste form matrix and the amount of rubidium remaining in the waste form matrix. The inner surface of the breached capsules will be examined for corrosion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of NDE for Key Indicators of Aging Cables in Nuclear Power Plants – Interim Status

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and industry (represented by the Electric Power Research Institute), an assessment of cable NDE methods was commissioned. Technologies include both bulk electrical measurements (Tan d, time domain reflectometry, frequency domain reflectometry (FDR), partial discharge, and other techniques) and local insulation measurement (indenter, dynamic mechanical analysis interdigital capacitance, infrared spectral measurement, etc.). This aging cable NDE program update reviews the full range of techniques but focuses on the most interesting test approaches that have a chance to be deployed in-situ, particularly including Tan d, FDR, and ultrasound methods that have been reviewed most completely in this progress period.

cable aging inspection↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal cycling testing to failure of a ceramic column grid array package for space applications

Ceramic column grid array (CCGA) packages have been used increasingly in logic and microprocessor functions, telecommunications, flight avionics boards, payload electronics boards, engineering navigational and science cameras, electronic assemblies, and other applications, because of their inherent advantages such as high electrical interconnect density, very good thermal and electrical performance, and compatibility with standard surface-mount technology (SMT) packaging assembly processes. Because these advanced electronic packages tend to have less solder-joint strain-relief than do leaded flat-pack electronic packages, the reliability of CCGA packages in challenging thermal environments is a very important consideration for their short- and long-term use in JPL-NASA space missions. In this study, we assembled daisy chains of polyimide printed wiring boards from CCGA-interconnect packages, inspected the boards nondestructively, and then subjected them to thermal cycling to assess their reliability in thermal environments from +125°C to -40°C±25°C. The test hardware consists of a CCGA 1752 package (CN version). The package was divided into four daisy-chained sections that were electrically monitored for their continuity during thermal cycling. The CCGA 1752 package is roughly 45 mm × 45 mm with a 42-mm × 42-mm array of 80%/20% Pb/Sn columns on a 1.00-mm pitch. The resistance of the daisy-chained CCGA interconnects was continuously monitored during thermal cycling in a gaseous nitrogen environment. Electrical continuity resistance measurements as a function of thermal cycling are reported here; tests to date have shown significant change to an open circuit in daisy-chain resistance as a function of thermal cycling. The change in interconnect resistance becomes increasingly noticeable with increasing number of thermal cycles. This paper describes the experimental thermal-cycling test results of CCGA 1752 package reliability testing under an extremely wide temperature range. The first failure was observed at 1479th thermal cycle. We report the thermal-cycle reliability test data for ~2500 thermal cycles.

Ramesham, Rajeshuni↗

Capability Demonstrations for Penetrant Nondestructive Evaluation (NDE) of Metallic Tanks and Composite Overwrapped Pressure Vessel (COPV) Liners

As the desired crack detection size is decreased and approaches the physical limitations of liquid penetrant inspection techniques, the approach of performing a probability of detection (POD) validation test at a single aspect ratio, and then extending the results to other aspect ratios based on equivalent area predictions may not be valid. POD testing for penetrant inspection of metallic pressure vessels and COPV liners should be performed at the bounds of the required range of crack aspect ratios.

Metallic Tanks↗